Selected language English English
Change language
Change language page on Deutsch DeutschChange language page on Español EspañolChange language page on Français FrançaisChange language page on Italiano ItalianoChange language page on Polski PolskiChange language page on Türkiye Türkiye ČeskyChange website to USA USAChange language page on 中文 中文

WLC 6/F1/R Precision Balance

WLC 6/F1/R Precision Balance
This image is for reference only.

Product code: WL-206-0074
Request for quotation

Overview

Maximum capacity [Max]: 6kg
Readability [d]: 0.1g

Precision

balances

enable fast and accurate determination of

mass

in laboratory and industry. The devices are equipped with RS232 connector and an internal battery which allows their operation in places where there is no access to the mains (230V). The

balance

features a stainless steel

weighing

pan, and a backlit LCD guaranteeing clear

weighing

result presentation. Optionally, they can be equipped with additional RS232 connector.

WLC series

balance

is available in dual range (non-verified) version on surcharge.
 

Functions

Plus/Minus Control

Plus/Minus Control

Control of sample's mass carried out with reference to specified MIN and MAX thresholds. The weight is considered to be correct if it is comprised within threshold values. A graphic visualisation of weighing result is displayed in a form of a bar graph.
Percent Weighing

Percent Weighing

Percent Weighing function is used for comparision of measured products with mass standard. Mass of a mass standard may be a numeric value taken from a database or it may be determined through a measurement process. Each measured product is compared to mass standard, mass of which is presumed as a model 100% ideal mass. For products weighing less than the mass standard, obtained results are lower than 100%, for products weighing more, the obtained results are greatly  exceeded.
Totalizing

Totalizing

Function adding new mass value to already obtained one. This allows to determine mass content of the mixture, being a composition of number of different consistence components. Totalizing is limited by maximum capacity parameter.
Parts counting

Parts counting

Function using mass measurement for determination of  measured items quantity. Mass of a single item is required for this process. It may be either estimated through weighment or taken from a database. For items counting the following algorithm is used: all items mass / single item mass = quantity. Function operation is supperted by a mechanism of Automatic Correction of Accuracy. This allows to update single item mass in course of the process. To a certain extend Automatic Correction of Accuracy eliminates error which may be a result of different mass values of seemingly alike single elements. For industry solutions items counting may be simultaneously carried out with checkweighing and dosing thus industry solutions feature audio signalling base informing that specified number of items has been weighed. It is possible to apply weighing systems using few platfroms of different MAX capacities and different accuracies.
Internal battery

Internal battery

Internal and rechargeable battery of SLA 6 V type (sealed lead acid) enables device operation without connecting the device to the mains (9h operation). The weighing instrument controls battery status and displays a respective pictogram on the screen.
Peak hold

Peak hold

Function registering the greatest temporary indication occurring in course of the weighing process. It is most often used in medical scales in order to hold the measurement indication.
Newton unit measurement

Newton unit measurement

Function allowing to perform the measurement in Newton unit, it may be used for processes aiming to determine force resulting in the sample damage.

Datasheet

Maximum capacity [Max]

6

 kg

Readability [d]

0.1

 g

Tare range

-6

 kg

Repeatability

0.1

 g

Linearity

±0.2

 g

Stabilization time

3

 s

Display

LCD (backlit)

 

Protection class

IP 43

 

Communication interface

RS232

 

Power supply

100 ÷ 240 V AC 50 / 60 Hz and battery

 

Operation time on batteries

10 h (average time)

 

Operating temperature

+15 ÷ +30

 °C

Atmospheric humidity

10% ÷ 85% RH no condensation

 

Weighing pan dimensions

300×300

 mm

Packaging dimensions

570×390×170

 mm

Net weight

5.2

 kg

Gross weight

6

 kg

Documentation

Technical specification
Publications and teaching materials

User Manual
(0.91 MB)

Save
See the publication

Data Sheet
(0.93 MB)

Save
See the publication

Conformity Declaration
(0.04 MB)

Save
See the publication

Accessories

Granite Antivibration tables
R-LAB
RAD-KEY
LabVIEW Driver
Receipt printer
RS 232 cables (scale - EPSON printer)
RS 232, RS 485 cables
Cigarette lighter receptacle power supply cables
RS232 1345 Converter
RS232 1339 Converter
Power loop output
Displays

Radwag Balances and Scales

Torunska 5
26-600 Radom
Poland
tel.: +48 48 386 63 03
e-mail: export@radwag.com
TIN: PL7960000327
Vimeo Radwag YouTube Radwag Facebook Radwag
© 2019 RADWAG Balances and Scales. All rights reserved.

See our movies
RADWAG

Radwag WEBINARS