Microbalance XA 53.5Y.M.A.P

Radwag Les Balances Electroniques
Selected language Français
Microbalance XA 53.5Y.M.A.P
This image is for reference only.

Microbalance XA 53.5Y.M.A.P

Code produit: WL-112-0003
Change the model (5)
done
Max: 53gd: 1µg

 ø26mm
expand_more
Max: 6 / 21gd: 1 / 2µg

 ø26mm
Max: 21gd: 1µg

 ø26mm
Max: 21 / 52gd: 1 / 5µg

 ø26mm
Max: 52gd: 5µg

 ø26mm
Capacité maximale [Max]: 53 g
Précision de lecture: 1 µg

close
Change the model:
Microbalance XA 6/21.5Y.M.A.P
Microbalance XA 21.5Y.M.A.P
Microbalance XA 21/52.5Y.M.A.P
Microbalance XA 52.5Y.M.A.P
Microbalance XA 53.5Y.M.A.P
Select all
Voir
Download
Pour Comparer Recherche avancée
Description

Microbalance XA 53.5Y.M.A.P
pour l’étalonnage des pipettes

 
Les microbalances XA 5Y.M.A.P sont utilisées pour étalonner des pipettes monocanal d’une capacité de 0,5 µl. L’étalonnage des pipettes consiste à vérifier si la pipette prélève autant qu’elle le devrait et donc si le résultat de la mesure se situe dans l’erreur tolérée. La microbalance XA 5Y.M.A.P est le même modèle que la microbalance XA 5Y.M.A., elle est juste dotée des accesoires qui servent à l’étalonnage et notamment : adaptateur automatique pour étalonnage, verrerie et piège anti-évaportation (touts les éléments ont été stipulés ci-dessous sur la fiche technique).
 
 
 

Ionisation antistatique complète

Les microbalances XA 5Y.M.A.P disposent d’un ioniseur antistatique intégré et d’une chambre de pesée à ouverture automatique. L’ioniseur antistatique neutralise les charges électrostatiques de l’échantillon lors de chaque procédure de pesée, c’est-à-dire à chaque ouverture de la chambre. Celle dernière est contrôlée par des gestes, c’est-à-dire sans contact.
 
 
 
 
 
Avez-vous besoin d’une balance qui non seulement détermine la masse avec une précision impressionnante, mais effectue également des audits numériques, répond à vos commandes vocales et vous envoie des messages légers ?
 
 
Si oui, découvrez les fonctionnalités des balances de la série ELLIPSIS :
 
 

Digital Weighing Auditor

s’assure que votre balance est prête à fonctionner. Il permettra une compensation en temps réel de la flottabilité de l’air. De plus, il informera de la nécessité d’effectuer un examen du solde ou un audit périodique de l’exactitude et de la sensibilité du solde.
 
 
 

Écran 10 pouces

L’écran plus grand – 10’’ – signifie plus d’informations en un seul endroit. Sur le nouveau terminal ELLIPSIS, vous pouvez même voir 3 écransdes widgetsdes graphiquesdes statutsdes notes et un historique de mesure pratique.
 
 
 

Ambient Light – un moyen de communication innovant entre la balance et l’utilisateur

La couleur de surbrillance vous informe sur l’état, les résultats du processus, les procédures ou les alertes.
 
 
 
 

Une façon sans compromis de vérifier l’utilisateur

Pour la première fois dans l’histoire, la balance vérifiera l’utilisateur à l’aide d’un mot de passed’une carte RFIDd’un lecteur d’empreintes digitalesd’un moteur de reconnaissance faciale ou de toute combinaison de ceux-ci.
 
 
 

Hotspot

Utilisez la balance sur n’importe quel dispositif connecté. Il peut s’agir d’un smartphone, d’une tablette ou d’un ordinateur.
 
 
 

Live Note – notez vos conclusions

C’est la première fois que vous ajoutez un mémo vocal à une série de mesures ou à un rapport de procédure. Si vous préférez l’écrire, ELLIPSIS vous permettra d’ajouter une note textuelle.
 
 
 

RFID

ELLIPSIS fonctionne avec des étiquettes RFID* qui peuvent être utilisées pour marquer vos produits ou ingrédients de recette dans la base de données. De plus, elles peuvent être utilisées pour identifier l’utilisateur.
 
 
 

Handy Library

C’est là que vous verrez une série de mesures récentes ou un rapport prêt pour la signature numérique conformément à 21 CFR Part 11.
 
 
 

Widget

Préparé pour afficher ce dont vous avez le plus besoin en ce moment.
 
 
 

Smart Min Weight

La balance affiche des informations indiquant si la valeur de masse que vous souhaitez peser est inférieure ou supérieure au seuil de pesée minimum.
 
 
 

Mise à niveau automatique de la balance ReflexLEVEL System

Au lieu de niveler manuellement la balance, nivelez-la automatiquement.
Le système ReflexLEVEL vous fait gagner du temps et vous offre une précision maximale dans les mesures.
 
 
 

21 CFR Partie 11

Vous travaillez dans l’industrie pharmaceutique ? Avez-vous besoin d’une signature numérique ?

Nous proposons une balance de laboratoire qui, en tant que dispositif autonome, répond aux exigences de 21 CFR Partie 11/ EU BPL Annex 11.
 
 Sécurité totale des données
 Signatures électroniques
 Validations
 Dossiers électroniques
 Pistes d’audit 
 
 
 

Le Modbus TCP/IP

est un de protocoles plus populaires dans le domaine des systèmes de communication industrielle automatisée. Incorporé aux balances 5Y et CY10, en raison de sa capacité à mettre en réseau divers dispositifs, le protocole facilite le travail à des intégrateurs.
 
Le protocole Modbus échange des informations en utilisant un mécanisme de requête-réponse entre un automate programmable industriel API (PLC) qui est un maître et la balances qui est un esclave. Dans les balances 5Y et C10, le protocole Modbus TCP/IP permet, entre autres, les fonctions de lecture de masse, zérotage et tarage de la balance, ainsi que de configuration de la tare et des seuils MIN et MAX.
 
 
 

Réglage en deux points

Le réglage, qui s’effectue en deux points de mesure au lieu d’un, augmente la précision de la mesure sur toute la plage de pesée. Qu’est-ce que cela signifie pour vous? Mesure plus précise.
 
 
* RFID ISO/IEC 14443 Type A, 13,56 MHz
 
 
Paramètres Techniques
Capacité maximale [Max]

53

 g

Capacité minimale [Min]

0,1

 mg

Précision de lecture

1

 µg

Échelon de légalisation [e]

1

 mg

Étendue de tare

-53

 g

Répétabilité standard [5% Max]

1,5

 µg

Répétabilité standard [Max]

6

 µg

Poids minimal d’echantillon standard (USP)

3

 mg

Poids minimal d’echantillon standard (U=1%, k=2)

0,3

 mg

Répétabilité admissible [5% Max]

2,4

 µg

Répétabilité admissible [Max]

8

 µg

Linéarité

±20

 µg

Non-centricité

20

 µg

Stabilité de sensibilité

1×10⁻⁶/année×Rt

 

Temps de stabilisation

~ 3,5

 s

Ajustage

interne (automatique)

 

Classe de précision OIML

I

 

Système de nivellement

automatique – Reflex Level System

 

Afficheur

10″ graphique couleurs écran tactile

 

Porte de la cage de pesée

automatiques

 

Élément du kit

Microbalance, plateau, couvercle de plateau, adaptateur secteur, adaptateur automatique pour le calibrage des pipettes: (base, bague inférieure, récipient en verre, adaptateur automatique pour le calibrage des pipettes, rideau de vapeur, plateau, couvercle en verre, couvercle à fermeture mécanique, vis de fixation), pinceau, housse.

 

Dimensions de la chambre de pesée

199×170×217

 mm

Capacité

11 ml

 

Dimension du plateau

ø26

 mm

Dimensions de colis

750×492×595

 mm

Masse nette

14,5

 kg

Masse brute

18,9

 kg

Degré de protection

IP 43

 

Interface de Communication

2×USB-A, USB-C, HDMI, Ethernet, Wi-Fi®, Hotspot

 

Alimentation

Adapter: 100 – 240V AC 50/60Hz 1A; 15V DC 2,4A
Balance: 12 – 15V DC 1,4A max*

 

Température du travail

+10 – +40

 °C

Vitesse de changements de température de travail

±0,3 °C / 1 h (±1 °C / 8 h)

 

Humidité relative d'air

40% – 80%

 

Vitesse de changements d'humidité relative d'air

±1% / h (±4% / 8 h)

 

CE
Légalisation Extra payment
for verification
5 ans de garantie
Répétabilité exprimée comme un écart standardisé de 10 placements de chargé.
Temps de stabilisation dépend de conditions externes et de la dynamique du placement d’un poids sur le plateau; déterminé pour le profil FAST.
* L'alimentation électrique peut être connectée à la prise à l'arrière du boîtier de la balance ou au terminal.
360°

Films
5Y Functions: DWA®
5Y Balance and Barcode Scanner – Easy Connection
New Menu Language in 5Y Series Balances: Japanese
5Y Functions: Checkweighing
5Y Functions: Dosing
5Y Functions: Formulations
Percentage deviations
5Y Functions: Weighing
5Y Functions: Parts counting
5Y Functions: Proximity Sensors – Touch-Free Control (Tutorial)
5Y Functions: GLP Procedures – Objective Documentation of Measurements (Tutorial)
Weighing Printout Design in Analytical and Precision Balances (Tutorial)
Impression facile avec Wi-Fi® Thermal Receipt Printer – imprimante de reçus thermique de Radwag
ELLIPSIS – une nouvelle balance de RADWAG
ELLIPSIS – Innovation technologique
Dis-le! Commandes vocales dans la nouvelle balance ELLIPSIS de RADWAG
ELLIPSIS – Scannez ou passez la carte devant le lecteur
Connexion VPN à la balance ELLIPSIS
ELLIPSIS – Connexions illimitées
Connexion de la balance série 5Y a l’imprimante RTP-UEW80 via Wi-Fi®®
Microbalance XA 5Y – Déballage et mise en service (Tutoriel)
NOUVEAUTE : Première imprimante de reçus de production RADWAG!
Solution complète pour la mesure de la masse en pharma
New AS and PS 5Y Balances – Autotest (Tutorial)
Fonctions
Autotest

Autotest

Diagnostic function aiming at metrological parameters determination (repeatability), the parameters are determined for the actual conditions of use. When speaking of repeatability it may be also used for weighing time optimization. Autotest is operated in an automatic mode thus operator’s time is saved.
Percent Weighing

Percent Weighing

Percent Weighing function is used for comparision of measured products with mass standard. Mass of a mass standard may be a numeric value taken from a database or it may be determined through a measurement process. Each measured product is compared to mass standard, mass of which is presumed as a model 100% ideal mass. For products weighing less than the mass standard, obtained results are lower than 100%, for products weighing more, the obtained results are greatly  exceeded.
Peak hold

Peak hold

Function registering the greatest temporary indication occurring in course of the weighing process. It is most often used in medical scales in order to hold the measurement indication.
Statistics

Statistics

Statistiscs function registers and analyses performed measurements. This supplies the user withthe following information: Max and Min standard deviation, average value, variance, range et.
IR sensors

IR sensors

Programmable function supporting the weighing process through control of the following options: sliding weighing chamber doors, printout, zeroing, tarring etc. Especially appreciated wherever preventing the balance from soiling is important.
GLP Procedures

GLP Procedures

Diagnostic function allowing to objectively document performed measurements. GLP procedures may be either presented in a short report form or extended one.
Pipettes Calibration

Pipettes Calibration

Function verifying correctness of piston pipettes functioning, the verification is performed via gravimetric measurement of the excreted liquid. Pipettes calibration may be either a stand-alone module or it may be operated
Air density correction

Air density correction

Function performing correction of mass measurement indication, wherein the air density is taken into account. It is used in balances with reading unit < 0,01 mg.
Automatic sliding door

Automatic sliding door

Automatic side panes opened via touch-free IR sensors.
Moveable range

Moveable range

Dual range analytical balances can be equipped with much more precise measuring range but only in very limited part of max capacity and only from zero load. A new technology introduced by RADWAG allows for moving this limited range till max capacity of the balance is reached. Such solution has been named as: Moveable range.
Differential weighing

Differential weighing

Differential weighing informs about mass variation a particular sample, wherein the said variation is a result of manufacturing processes.

Differential weighing is often applied in product control process, for which reference product parameters have been specified in order to be used as a source of comparison for the whole series.
Insuchcasestandard deviation is the information which tells about quality and completeness of a final product. For systems based on a feed-back technique such information may be used by control units.
Ambient conditions monitoring

Ambient conditions monitoring

The possibility of cooperation with the THBR 2.0 system
Replaceable unit

Replaceable unit

Replaceable units.
Statistical Quality Control

Statistical Quality Control

Statistical control for determination of basic statistical criteria: maximum, minimum, standard deviation, mean values for each batch, etc.
ALIBI Memory

ALIBI Memory

"ALIBI" memory enables saving and storing up to 100000 measurements.  Measurements are saved automatically upon each pressing of the key. There is no need for any additional operations or changing settings.
The following data related with the measurements is saved: measurement date; measurement time; result (mass); tare value; operator carrying out the measurement (logged in); product name.
The software saves the measurement in a so called loop, i.e. when the measurement no. 100001 is saved, the measurement 1 gets automatically deleted from the memory.
Measurements saved to balance memory cannot be deleted.
You can preview and print out the data saved to the ALIBI database.
Wi-Fi®

Wi-Fi®

Thanks to wireless communication between the computer and a balance, it is possible to use a balance inside a laminar flow hood and a fume cupboard.

Documentation
Cartes de produits
Data Sheet Data Sheet
Data Sheet

Voir
Voir
Download
Download

Choose more product:
Voir Voir DownloadDownload
Modes d'emploi
User Manual
User Manual
Voir
Voir
Download
Download
(2.36 MB)
User Manual
User Manual
Voir
Voir
Download
Download
(1.24 MB)
Software Manual
Software Manual
Voir
Voir
Download
Download
(1.23 MB)
User Manual
User Manual
Voir
Voir
Download
Download
(13.23 MB)
Start up Guide
Start up Guide
Voir
Voir
Download
Download
(4.76 MB)
Software Manual
Software Manual
Voir
Voir
Download
Download
(0.95 MB)
Déclarations de conformité
Conformity Declarations
Conformity Declarations
Voir
Voir
Download
Download
(0.04 MB)
Publications et brochures
Laboratory balance cleaning
Laboratory balance cleaning
Voir
Voir
Download
Download
(2.52 MB)
RTP Thermal Receipt Printer
RTP Thermal Receipt Printer
Voir
Voir
Download
Download
(1.64 MB)
Lexique des Termes Élémentaires de Métrologie
Lexique des Termes Élémentaires de Métrologie
Voir
Voir
Download
Download
(17.18 MB)
RFID
RFID
Voir
Voir
Download
Download
(0.68 MB)
Hybrid Protective Glass
Hybrid Protective Glass
Voir
Voir
Download
Download
(1.86 MB)
Micro Scale Measurement
Micro Scale Measurement
Voir
Voir
Download
Download
(2.74 MB)
Laboratory Balances
Laboratory Balances
Voir
Voir
Download
Download
(1.68 MB)
Metrology in the laboratory 2024
Metrology in the laboratory 2024
Voir
Voir
Download
Download
(5.65 MB)
Weighing systems for calibration  and verification of piston pipettes
Weighing systems for calibration and verification of piston pipettes
Voir
Voir
Download
Download
(5.27 MB)
ELLIPSIS Balances de laboratoire série 5Y
ELLIPSIS Balances de laboratoire série 5Y
Voir
Voir
Download
Download
(29.83 MB)
Accessoires
R-LAB

Accessoires

Modules additionnels

RES Protocole de communication Radwag3
Module de conformité à 21 CFR partie 113

Radwag Balances Électroniques
Torunska 5
26-600 Radom
Poland
tel.: +48 48 386 60 00
e-mail: export@radwag.com
TIN: PL7960000327
Vimeo Radwag YouTube Radwag Facebook Radwag LinkedIn Radwag
© 2024 RADWAG Balances Électroniques. Tous les droits sont réservés.

Wybierz język

×
Change language AlbanianAlbanian
Change language DanishDanish
Change language NederlandseNederlandse
Change language EstonianEstonian
Change language FinnishFinnish
Change language HungarianHungarian
Change language IcelandicIcelandic
Change language KazakhKazakh
Change language LatvianLatvian
Change language LithuanianLithuanian
Change language MacedonianMacedonian
Change language NorwegianNorwegian
Change language PortuguesePortuguese
Change language RomanianRomanian
Change language RussianRussian
Change language SlovakSlovak
Change language SlovenianSlovenian
Change language SwedishSwedish
Change language UkrainianUkrainian
Change language SerbianSerbian
Change language MontenegrinMontenegrin
Change language page on Deutsch Deutsch
Change language page on English English
Change language page on Español Español
Change language page on Italiano Italiano
Change language page on Polski Polski
Change language page on Türkiye Türkiye
Česky
Português (Brasil)
Change website to USA USA
Change language page on 中文 中文
Presentations Presentations Presentations
Subscribe Subscribe Subscribe
Radwag in Facebook Radwag in Facebook Facebook
Radwag in YouTube Radwag in YouTube Youtube
Radwag in Vimeo Radwag in Vimeo Vimeo
Radwag in LinkedIn Radwag in LinkedIn LinkedIn
Webinars Radwag Webinars Radwag Webinars
close
E-mail:
Nom de l’entreprise :
Prénom:
I consent to the processing of my personal data for marketing purposes by Radwag Wagi Elektroniczne Witold Lewandowski.
I consent to receive marketing and product-related messages by electronic means from Radwag Wagi Elektroniczne Witold Lewandowski.
I have read the Privacy Policy of RADWAG Wagi Elektroniczne Witold Lewandowski.
lock_openI want to access the files
close
Slide to go back ↩