WPT/4 6000 C11 Platform Scale

WPT/4 6000 C11 Platform Scale
This image is for reference only.

Product code: WP-202-0066
Request for quotation

Overview

Maximum capacity [Max]: 6000kg
Readability [d]: 2kg

Measurement with application of 4 load cells is a guarantee of precise

mass

reading, regardless of load positioning on the

weighing

platform. The platform

scales

WPT/4 series is made of mild steel powder coated construction of the

weighing

platform. The platform comprises 4 load cells connected to an

indicator

PUE C/31H series featuring backlit LCD display and 5 function buttons.

The weighing platform and the

indicator

are connected through a long cable enabling hanging the indicator on a wall.
The WPT/4 series is available in pit version for easy placing heavy loads on the weighing platform without application of ramps.

Scales is  available in dual range version on surcharge.
 

Functions

Plus/Minus Control

Plus/Minus Control

Control of sample's mass carried out with reference to specified MIN and MAX thresholds. The weight is considered to be correct if it is comprised within threshold values. A graphic visualisation of weighing result is displayed in a form of a bar graph.
Percent Weighing

Percent Weighing

Percent Weighing function is used for comparision of measured products with mass standard. Mass of a mass standard may be a numeric value taken from a database or it may be determined through a measurement process. Each measured product is compared to mass standard, mass of which is presumed as a model 100% ideal mass. For products weighing less than the mass standard, obtained results are lower than 100%, for products weighing more, the obtained results are greatly  exceeded.
Totalizing

Totalizing

Function adding new mass value to already obtained one. This allows to determine mass content of the mixture, being a composition of number of different consistence components. Totalizing is limited by maximum capacity parameter.
Parts counting

Parts counting

Function using mass measurement for determination of  measured items quantity. Mass of a single item is required for this process. It may be either estimated through weighment or taken from a database. For items counting the following algorithm is used: all items mass / single item mass = quantity. Function operation is supperted by a mechanism of Automatic Correction of Accuracy. This allows to update single item mass in course of the process. To a certain extend Automatic Correction of Accuracy eliminates error which may be a result of different mass values of seemingly alike single elements. For industry solutions items counting may be simultaneously carried out with checkweighing and dosing thus industry solutions feature audio signalling base informing that specified number of items has been weighed. It is possible to apply weighing systems using few platfroms of different MAX capacities and different accuracies.
Internal battery

Internal battery

Internal and rechargeable battery of SLA 6 V type (sealed lead acid) enables device operation without connecting the device to the mains (9h operation). The weighing instrument controls battery status and displays a respective pictogram on the screen.
Peak hold

Peak hold

Function registering the greatest temporary indication occurring in course of the weighing process. It is most often used in medical scales in order to hold the measurement indication.
Animal weighing

Animal weighing

Process of mass determination for a product which may unwillingly reposition within the weighing pan. Mass determination in such cases requires much longer period of time when compared to typical weighing process. It is the user who defines period of time needed for control of measured product mass. The user can thus optimize the function depending on the measured product characteristics.

Datasheet

Maximum capacity [Max]

6000

 kg

Minimum load

40

 kg

Readability [d]

2

 kg

Tare range

-6000

 kg

OIML Class

III

 

Display

LCD (backlit)

 

Protection class

IP 65 construction, IP 68 (1h max)/69 indicator

 

Communication interface

RS232

 

Power supply

100 ÷ 240 V AC 50 / 60 Hz and battery

 

Operation time on batteries

45 h (average time)

 

Operating temperature

-10 ÷ +40

 °C

Atmospheric humidity

10% ÷ 85% RH no condensation

 

Weighing pan dimensions

2000×2000

 mm

Weighing platform height

160 ±10

 mm

Scale mass with indicator

350

 kg

Documentation

Technical specification
Publications and teaching materials

User Manual
(2.00 MB)

Save
See the publication

Data Sheet
(0.85 MB)

Save
See the publication

Conformity Declaration
(0.03 MB)

Save
See the publication

Terminal and Scales Operated in Industry
(4.81 MB)

Save
See the publication

Measuring_instruments_in_industry
(0.05 MB)

Save
See the publication

Pit installation frame
(0.13 MB)

Save
See the publication

Accessories

Scales Editor
R-LAB
RAD-KEY
LabVIEW Driver
Receipt printer
Ramps

Accessories

Product name

Overview

Ramp for WPT/4 C6 1500kg scale

The ramps are used to easily place the trolleys containing loads onto the 4 load cell platform scales. They enable placing the scale into the production line as ...

Ramp for WPT/4 C7 1500kg scale

The ramps are used to easily place the trolleys containing loads onto the 4 load cell platform scales. They enable placing the scale into the production line as ...

Ramp for WPT/4 C8 3000kg scale

The ramps are used to easily place the trolleys containing loads onto the 4 load cell platform scales. They enable placing the scale into the production line as ...

Ramp for WPT/4 C9 1500kg scale

The ramps are used to easily place the trolleys containing loads onto the 4 load cell platform scales. They enable placing the scale into the production line as ...

Ramp for WPT/4 C9 3000kg scale

The ramps are used to easily place the trolleys containing loads onto the 4 load cell platform scales. They enable placing the scale into the production line as ...

Ramp for WPT/4 C9 6000kg scale

The ramps are used to easily place the trolleys containing loads onto the 4 load cell platform scales. They enable placing the scale into the production line as ...

Ramp for WPT/4 C10 3000kg scale

The ramps are used to easily place the trolleys containing loads onto the 4 load cell platform scales. They enable placing the scale into the production line as ...

Ramp for WPT/4 C10 6000kg scale

The ramps are used to easily place the trolleys containing loads onto the 4 load cell platform scales. They enable placing the scale into the production line as ...

Ramp for WPT/4 C11 3000kg scale

The ramps are used to easily place the trolleys containing loads onto the 4 load cell platform scales. They enable placing the scale into the production line as ...

Ramp for WPT/4 C11 6000kg scale

The ramps are used to easily place the trolleys containing loads onto the 4 load cell platform scales. They enable placing the scale into the production line as ...

Cigarette lighter receptacle power supply cables
RS 232 cables (scale - EPSON printer)
RS 232, RS 485 cables
Stands, wall mounting kits and mounting brackets
Power loop output
RS232 1339 Converter
RS232 1345 Converter
Displays

Radwag Balances and Scales

Torunska 5
26-600 Radom
Poland
tel.: +48 48 386 60 00
e-mail: export@radwag.com
TIN: PL7960000327
Vimeo Radwag YouTube Radwag Facebook Radwag
© 2019 RADWAG Balances and Scales. All rights reserved.

See our movies
RADWAG

Radwag WEBINARS