Waage mit hoher Auflösung HY10.600.HRP.H.M2.1

Radwag Elektronische Waagen
Selected language Deutsch
Waage mit hoher Auflösung HY10.600.HRP.H.M2.1
Übersichtsbild

Waage mit hoher Auflösung HY10.600.HRP.H.M2.1

Produktcode: WP-340-0025
Modell ändern (32)
done
Max: 600kgd: 10g

 1000×800mm
expand_more
Max: 10kgd: 0,02g

 360×280mm
Max: 16kgd: 0,1g

 360×280mm
Max: 16kgd: 0,1g

 360×280mm
Max: 32kgd: 0,1g

 360×280mm
Max: 32kgd: 0,1g

 360×280mm
Max: 62kgd: 1g

 500×400mm
Max: 62kgd: 0,1g

 500×500mm
Max: 62kgd: 2g

 500×400mm
Max: 62kgd: 0,1g

 500×400mm
Max: 120kgd: 0,5g

 500×500mm
Max: 120kgd: 1g

 500×400mm
Max: 120kgd: 5g

 500×400mm
Max: 120kgd: 0,5g

 500×400mm
Max: 150kgd: 1g

 800×600mm
Max: 150kgd: 1g

 500×400mm
Max: 150kgd: 1g

 500×500mm
Max: 150kgd: 1g

 800×600mm
Max: 150kgd: 5g

 800×600mm
Max: 200 / 500 / 1000kgd: 20 / 50 / 100g

 1000×800mm
Max: 300kgd: 1g

 800×600mm
Max: 300kgd: 1g

 800×600mm
Max: 300kgd: 1g

 1000×800mm
Max: 300kgd: 1g

 1000×800mm
Max: 500 / 1000 / 2000kgd: 50 / 100 / 200g

 1250×1000mm
Max: 600kgd: 5g

 1000×800mm
Max: 600kgd: 20g

 1000×800mm
Max: 1100kgd: 10g

 1000×800mm
Max: 1100kgd: 10g

 1000×800mm
Max: 1100kgd: 50g

 1000×800mm
Max: 2000kgd: 10g

 1250×1000mm
Max: 2000kgd: 10g

 1250×1000mm
Wägebereich [Max]: 600 kg
Ziffernschritt [d]: 10 g

close
Modell ändern:
Waage mit hoher Auflösung HY10.10.HRP.H
Waage mit hoher Auflösung HY10.16.HRP.H
Waage mit hoher Auflösung HY10.16.HRP.H.M2.1
Waage mit hoher Auflösung HY10.32.HRP.H.M2.1
Waage mit hoher Auflösung HY10.32.HRP.H
Waage mit hoher Auflösung HY10.62.HRP.H.M2.1
Waage mit hoher Auflösung HY10.62.2.HRP.H
Waage mit hoher Auflösung HY10.62.HRP.H.M2.2
Waage mit hoher Auflösung HY10.62.HRP.H
Waage mit hoher Auflösung HY10.120.2.HRP.H
Waage mit hoher Auflösung HY10.120.HRP.H.M2.1
Waage mit hoher Auflösung HY10.120.HRP.H.M2.2
Waage mit hoher Auflösung HY10.120.HRP.H
Waage mit hoher Auflösung HY10.150.1.HRP.H
Waage mit hoher Auflösung HY10.150.HRP.H
Waage mit hoher Auflösung HY10.150.2.HRP.H
Waage mit hoher Auflösung HY10.150.1.HRP.H.M2.1
Waage mit hoher Auflösung HY10.150.1.HRP.H.M2.2
Waage mit hoher Auflösung HY10.1000.HRP.H.M3
Waage mit hoher Auflösung HY10.300.HRP.H.M2.1
Waage mit hoher Auflösung HY10.300.HRP.H
Waage mit hoher Auflösung HY10.300.1.HRP.H.M2.1
Waage mit hoher Auflösung HY10.300.1.HRP.H
Waage mit hoher Auflösung HY10.2000.HRP.H.M3
Waage mit hoher Auflösung HY10.600.HRP.H.M2.1
Waage mit hoher Auflösung HY10.600.HRP.H
Waage mit hoher Auflösung HY10.600.HRP.H.M2.2
Waage mit hoher Auflösung HY10.1100.HRP.H
Waage mit hoher Auflösung HY10.1100.HRP.H.M2.1
Waage mit hoher Auflösung HY10.1100.HRP.H.M2.2
Waage mit hoher Auflösung HY10.2000.HRP.H
Waage mit hoher Auflösung HY10.2000.HRP.H.M2.1
zum Vergleich Erweiterte Suche
Beschreibung

Maximale Robustheit

 
Die hochauflösenden HRP-Waagen  sind sehr robust. Ihre Plattformen zeichnen sich durch eine hohe Schutzart – IP 67 – aus. Sie verfügen über zusätzliche Dichtungselemente, die sie vor Staub, Schmutz und Feuchtigkeit schützen. Daher können die HRP-Waagen mit einem Hochdruckreiniger gereinigt werden.
 
 
 
 

9 Vorteile, 1 Monoblock

Die Möglichkeit, Lasten von bis zu 150 kg auf einer großen Waagschale mit hoher Genauigkeit und guter Wiederholbarkeit zu wiegen, minimale Exzentrizitätsfehler über den gesamten Bereich, schnelle und stabile Messungen (innerhalb von 1 Sekunde erreichbar), Stabilität der Parameter über die Zeit und nach dem Transport sowie eine Waagschalenabmessung angepasst an die Genauigkeit – all dies ist das Ergebnis des innovativen Messsystems

MONO

BLOCK®
-von RADWAG. Der neue – höhere und größere – 

MONO

BLOCK®
-von RADWAG garantiert die beste Wiederholbarkeit und Betriebsgeschwindigkeit.
 
 
 
 
 

Nicht von anderen wiederholbar

Die automatische Justierung mit einem internen Justiergewicht garantiert nicht nur die beste Arbeitsqualität und Wiederholbarkeit der Ergebnisse, sondern auch Zeitersparnis und Arbeitskomfort.
 
 
 

Für die Pharma-, Chemie-, Lebensmittel- und…

Die HY10.HRP-Waagen eignen sich ideal für industrielle Umgebungen, in denen eine hohe Messgenauigkeit und Wiederholbarkeit erforderlich ist, beispielsweise in der pharmazeutischen, chemischen und Lebensmittelindustrie. Die Waagen HY10.HRP und HX7.HRP, deren Terminals aus Edelstahl gefertigt sind, können sogar in anspruchsvollsten nassen Umgebungen eingesetzt werden.
 
 
 

Zwei Terminals zur Auswahl

Die hochauflösenden HRP-Waagen können mit einem von zwei Industrieterminals betrieben werden: PUE 7.1 und PUE HY10.

Das Terminal PUE 7.1 verfügt über:
  • 5, 7” Resistiv-Farb-Touchscreen,
  • Touch-Tastatur,
  • Gehäuse aus ABS-Kunststoff,
  • Schutzart IP 43,
  • Kommunikationsschnittstellen: 2xRS232, 2xUSB-A, Ethernet, 4 IN/ 4 OUT, Wi-Fi®®,
  • Optionale Zusatzmodule: A/C DP6-Wandler-Zusatzmodul

Das Terminal PUE HY10 verfügt über:
  • 10, 1” Grafik-Farb-Touchscreen,
  • Touch-Tastatur,
  • Gehäuse aus Edelstahl,
  • Schutzart IP 68/69,
  • Kommunikationsschnittstellen: 2xRS232, 2xUSB-A, Ethernet, 4 IN/ 4 OUT,
  • Optionale Zusatzmodule: Wi-Fi®®, RS485, Profibus, Profinet, Analogausgangsmodul, 12 IN/ 12 OUT.
 
 
 

Stahlkraft

Die Verwendung von rostfreiem Stahl für die Konstruktion garantiert eine lange Betriebsdauer der Waage. Sie ist unempfindlich gegenüber Feuchtigkeit und versehentlichem Verschütten. Die Robustheit und Haltbarkeit der HRP-Waagen  konstruktion ermöglichen die Wägung großer Objekte wie Paletten mit Fracht. Die stabile Plattform ist vibrationsbeständig, was bei der Wägung erheblicher Objekte wichtig ist.
 
 
 
 

Benötigen Sie ALIBI?

Hier haben Sie es. Der ALIBI-Speicher ist wie eine Blackbox der Waage. Alle auf dem Gerät durchgeführten Messungen werden darin gespeichert. Der ALIBI-Speicher kann nicht verändert oder gelöscht werden.
 
 
 
 

Nutzen Sie das Potenzial

Barcode-Scanner, Belegdrucker, Etikettendrucker oder zusätzliche Displays – mit der universellen Software kann die HY10-Waage mit all diesen Geräten zusammenarbeiten. Alle Zubehörteile finden Sie in unserem ständigen Angebot. Bei Fragen zur Kompatibilität stehen Ihnen unsere Experten gerne zur Verfügung.
 

Nicht nur Wägung

Aber auch Stückzählung, Kontrollwägung, Prozentwägung Tierwägung Rezepturen, Differenzwägung, Etikettierung, Peak-Hold und Statistik. Vielfältige Betriebsarten der HY10-Waage.
 
 
 
 
 
 
 
Edelstahl in RADWAG-Produkten
Erfahren Sie mehr über die Verwendung und Pflege von Edelstahlprodukten:
Rostfreier Stahl in RADWAG-Produkten. Standard- und Spezialanwendungen

Wi-Fi® ist eine eingetragene Marke der Wi-Fi Alliance®.
Technische Daten
Wägebereich [Max]

600

 kg

Min. Belastung

500

 g

Vorlast

60

 kg

Ziffernschritt [d]

10

 g

Eichwert [e]

100

 g

Tarierbereich

-600

 kg

Wiederholbarkeit

7,5

 g

Linearität

±15

 g

Stabilisierungszeit

3

 s

Justierung

intern (automatisch)

 

OIML-Klasse

II

 

Max. Anzahl der Eichwerte

6000 e

 

Display

10,1″ grafisch farbiger Touchscreen

 

Waagschale

1000×800

 mm

Verpackungsgröße

1000×1200×666

 mm

Nettogewicht

126

 kg

Bruttogewicht

160

 kg

Schutzart

IP 66 / 67 Konstruktion, IP 68 / 69 Messgerät

 

Konstruktion

Edelstahl AISI304

 

Waageschale

Edelstahl AISI304

 

Schnittstellen

2×RS232, 2×USB-A, Ethernet, 4 IN / 4 OUT (Digitalausgang)

 

Optionale Schnittstellen

Modul Wi-Fi® 802.11 b/g/n, Modul Profibus (DP SLAVE), Modul RS485, Modul PROFINET (RJ45), Analogausgangsmodul (4-20mA, 0-20mA, 0-10V) , 12IN / 12OUT (IN – 5-24 VDC, OUT – max 30 VDC, 0,5 ADC)

 

Stromversorgung

100 – 240 V AC 50/60 Hz

 

Umgebungstemperatur

+10 – +40

 °C

Relative Luftfeuchtigkeit

15% – 80%

 

CE
 Eichung Extra payment
for verification
Garantie 2 Jahre
Wiederholbarkeit wird als Standardabweichung von 10 Wägezyklen ausgedrückt.
Relative Luftfeuchtigkeit unter nicht kondensierenden Bedingungen.
Stabilisierungszeit unter optimalen Umgebungsbedingungen.
Videos
High Resolution Scales by RADWAG – Extremely Robust & Impressively Accurate
Complete Solutions for Mass Measurement in Pharma Industry
HY10 Hoch entwickeltes Wägeterminal
RADWAG Remote Desktop
RADWAG Remote Desktop - Windows 10
Funktionen
Dosing

Dosing

Weighing process for which reference mass has been determined together with tolerance for its determination. Dosing tolerance is given in [%] and it is calculated in relation to the reference value thus being a permissible deviation of this process. This solution is used for weighing powders, liquids and loose materials. Dosing function performance is often supported with bargraph - load indicator. For industrial scales it is possible to use a control systems of dosing process.
Labelling

Labelling

Marking products with the right symbols contributes to quick and reliable identification. The balance/scale usually transfers product mass or product quantity to the label printer. The transferred value is printed with the following information: bar code, pictogram, content, address etc. In laboratory the labelling is performed in a semi-automatic mode, for industry in an automatic one (dynamic scales).
Plus/Minus Control

Plus/Minus Control

Control of sample's mass carried out with reference to specified MIN and MAX thresholds. The weight is considered to be correct if it is comprised within threshold values. A graphic visualisation of weighing result is displayed in a form of a bar graph.
Percent Weighing

Percent Weighing

Percent Weighing function is used for comparision of measured products with mass standard. Mass of a mass standard may be a numeric value taken from a database or it may be determined through a measurement process. Each measured product is compared to mass standard, mass of which is presumed as a model 100% ideal mass. For products weighing less than the mass standard, obtained results are lower than 100%, for products weighing more, the obtained results are greatly  exceeded.
Totalizing

Totalizing

Function adding new mass value to already obtained one. This allows to determine mass content of the mixture, being a composition of number of different consistence components. Totalizing is limited by maximum capacity parameter.
Parts counting

Parts counting

Function using mass measurement for determination of  measured items quantity. Mass of a single item is required for this process. It may be either estimated through weighment or taken from a database. For items counting the following algorithm is used: all items mass / single item mass = quantity. Function operation is supperted by a mechanism of Automatic Correction of Accuracy. This allows to update single item mass in course of the process. To a certain extend Automatic Correction of Accuracy eliminates error which may be a result of different mass values of seemingly alike single elements. For industry solutions items counting may be simultaneously carried out with checkweighing and dosing thus industry solutions feature audio signalling base informing that specified number of items has been weighed. It is possible to apply weighing systems using few platfroms of different MAX capacities and different accuracies.
Peak hold

Peak hold

Function registering the greatest temporary indication occurring in course of the weighing process. It is most often used in medical scales in order to hold the measurement indication.
Formulation

Formulation

Function supporting the mixture making process, wherein the mixture contains various components. Formulation function usually uses the balance/scale database of components. Formulation serves for monitored checkweighing of every single component with a given tolerance. It is enriched with a set of individual settings.
Statistics

Statistics

Statistiscs function registers and analyses performed measurements. This supplies the user withthe following information: Max and Min standard deviation, average value, variance, range et.
Checkweighing

Checkweighing

Checkweighing function is used for checking whether the measured sample mass is within the predefined threshold values, Low [LO] and Hgh [HI]. The thresholds are given in [g] and [kg] units. Current state of a sample being measured is signalled by means of pictorgams located on a display for laboratory balances, for industrial scales Stackligt System is used. This visual +/- inspection is in operation during segregation, control or packing process of products for which mass has bees determined with a specifaied tolerance, eg. 12860 g 961
GLP Procedures

GLP Procedures

Diagnostic function allowing to objectively document performed measurements. GLP procedures may be either presented in a short report form or extended one.
Animal weighing

Animal weighing

Process of mass determination for a product which may unwillingly reposition within the weighing pan. Mass determination in such cases requires much longer period of time when compared to typical weighing process. It is the user who defines period of time needed for control of measured product mass. The user can thus optimize the function depending on the measured product characteristics.
Differential weighing

Differential weighing

Differential weighing informs about mass variation a particular sample, wherein the said variation is a result of manufacturing processes.

Differential weighing is often applied in product control process, for which reference product parameters have been specified in order to be used as a source of comparison for the whole series.
Insuchcasestandard deviation is the information which tells about quality and completeness of a final product. For systems based on a feed-back technique such information may be used by control units.
Replaceable unit

Replaceable unit

Replaceable units.
Statistical Quality Control

Statistical Quality Control

Statistical control for determination of basic statistical criteria: maximum, minimum, standard deviation, mean values for each batch, etc.
ALIBI Memory

ALIBI Memory

"ALIBI" memory enables saving and storing up to 100000 measurements.  Measurements are saved automatically upon each pressing of the key. There is no need for any additional operations or changing settings.
The following data related with the measurements is saved: measurement date; measurement time; result (mass); tare value; operator carrying out the measurement (logged in); product name.
The software saves the measurement in a so called loop, i.e. when the measurement no. 100001 is saved, the measurement 1 gets automatically deleted from the memory.
Measurements saved to balance memory cannot be deleted.
You can preview and print out the data saved to the ALIBI database.
Transactions

Transactions

Complex weighing mode for registration of weighings that are part of transactions such as sale, purchase and warehouse transfer. You can create a new transaction using the scale. It is possible to pause the transaction or abort it.  The function supports warehouse management in an enterprise.
Dokumentation
Datenblatt
Data Sheet Data Sheet
Data Sheet

Details anzeigen
Details anzeigen
Download
Download

Choose more product:
Details anzeigen Details anzeigen DownloadDownload
Bedienungsanleitungen
Software Manual - CBCP 03
Software Manual - CBCP 03
Details anzeigen
Details anzeigen
Download
Download
(0.23 MB)
User Manual - PUE HY10
User Manual - PUE HY10
Details anzeigen
Details anzeigen
Download
Download
(2.19 MB)
Start up Guide
Start up Guide
Details anzeigen
Details anzeigen
Download
Download
(1.38 MB)
Bedienungsanleitungen
Bedienungsanleitungen
Details anzeigen
Details anzeigen
Download
Download
(8.90 MB)
 Software Manual - PUE HY10
Software Manual - PUE HY10
Details anzeigen
Details anzeigen
Download
Download
(7.10 MB)
Software Manual - Radwag-Mass -Node-RED
Software Manual - Radwag-Mass -Node-RED
Details anzeigen
Details anzeigen
Download
Download
(0.57 MB)
 Software Manual - PROFIBUS communication protocol of PUE HY10
Software Manual - PROFIBUS communication protocol of PUE HY10
Details anzeigen
Details anzeigen
Download
Download
(0.65 MB)
Software Manual - MODBUS communication protocol of PUE 7.1 / PUE HY10
Software Manual - MODBUS communication protocol of PUE 7.1 / PUE HY10
Details anzeigen
Details anzeigen
Download
Download
(0.82 MB)
Quick start
Quick start
Details anzeigen
Details anzeigen
Download
Download
(2.47 MB)
User Manual - Connecting External Platform
User Manual - Connecting External Platform
Details anzeigen
Details anzeigen
Download
Download
(0.99 MB)
Software Manual - PROFINET communication protocol of HRP platforms
Software Manual - PROFINET communication protocol of HRP platforms
Details anzeigen
Details anzeigen
Download
Download
(2.02 MB)
User Manual - HRP Weighing Platforms
User Manual - HRP Weighing Platforms
Details anzeigen
Details anzeigen
Download
Download
(2.21 MB)
 Software Manual - PROFINET communication protocol of PUE HY10
Software Manual - PROFINET communication protocol of PUE HY10
Details anzeigen
Details anzeigen
Download
Download
(1.82 MB)
Konformitätserklärungen
Conformity Declaration
Conformity Declaration
Details anzeigen
Details anzeigen
Download
Download
(0.04 MB)
Publikationen und Broschüren
RTP Thermal Receipt Printer
RTP Thermal Receipt Printer
Details anzeigen
Details anzeigen
Download
Download
(1.64 MB)
THBR System 2.0
THBR System 2.0
Details anzeigen
Details anzeigen
Download
Download
(5.19 MB)
HRP High Resolution Scales
HRP High Resolution Scales
Details anzeigen
Details anzeigen
Download
Download
(9.41 MB)
Stainless Steel in RADWAG products. Standard and special applications
Stainless Steel in RADWAG products. Standard and special applications
Details anzeigen
Details anzeigen
Download
Download
(2.23 MB)
Wageterminal PUE HY10
Wageterminal PUE HY10
Details anzeigen
Details anzeigen
Download
Download
(0.29 MB)
Zubehör
Zusätzliche Module

Audit Trail3
Workflow-Modul (Funktionalität “Identifikationsprozess”)3
RDA - Datenzugangsmodul (RADWAG Data Access)3
RES Radwag Kommunikationsprotokoll3

RADWAG Elektronische Waagen
Torunska 5
26-600 Radom
Polen
Tel.: +48 48 386 60 00
E-mail: export@radwag.com
VAT Nr.: 796-000-03-27
Vimeo Radwag YouTube Radwag Facebook Radwag LinkedIn Radwag
© 2024 RADWAG Elektronische Waagen. Alle Rechte vorbehalten.

×
Change language AlbanianAlbanian
Change language DanishDanish
Change language NederlandseNederlandse
Change language EstonianEstonian
Change language FinnishFinnish
Change language HungarianHungarian
Change language IcelandicIcelandic
Change language KazakhKazakh
Change language LatvianLatvian
Change language LithuanianLithuanian
Change language MacedonianMacedonian
Change language NorwegianNorwegian
Change language PortuguesePortuguese
Change language RomanianRomanian
Change language RussianRussian
Change language SlovakSlovak
Change language SlovenianSlovenian
Change language SwedishSwedish
Change language UkrainianUkrainian
Change language SerbianSerbian
Change language MontenegrinMontenegrin
Change language page on English English
Change language page on Español Español
Change language page on Français Français
Change language page on Italiano Italiano
Change language page on Polski Polski
Change language page on Türkiye Türkiye
Česky
Português (Brasil)
Change website to USA USA
Change language page on 中文 中文
Presentations Presentations Presentations
Subscribe Subscribe Subscribe
Radwag in Facebook Radwag in Facebook Facebook
Radwag in YouTube Radwag in YouTube Youtube
Radwag in Vimeo Radwag in Vimeo Vimeo
Radwag in LinkedIn Radwag in LinkedIn LinkedIn
Webinars Radwag Webinars Radwag Webinars
close
E-Mail
Firma:
Vorname:
I consent to the processing of my personal data for marketing purposes by Radwag Wagi Elektroniczne Witold Lewandowski.
I consent to receive marketing and product-related messages by electronic means from Radwag Wagi Elektroniczne Witold Lewandowski.
I have read the Privacy Policy of RADWAG Wagi Elektroniczne Witold Lewandowski.
lock_openI want to access the files
close
Slide to go back ↩