Microbilancia XA 6/21.5Y.M.A.P

Radwag Bilance e sistemi di pesatura
Selected language Italiano
Microbilancia XA 6/21.5Y.M.A.P
This image is for reference only.

Microbilancia XA 6/21.5Y.M.A.P

Codice prodotto: WL-112-1000
Modifica del modello (5)
done
Max: 6 / 21gd: 1 / 2µg

 ø26mm
expand_more
Max: 21 / 52gd: 1 / 5µg

 ø26mm
Max: 21gd: 1µg

 ø26mm
Max: 52gd: 5µg

 ø26mm
Max: 53gd: 1µg

 ø26mm
Portata massima [Max]: 6 / 21 g
Divisione [d]: 1 / 2 µg

close
Modifica del modello:
Microbilancia XA 6/21.5Y.M.A.P
Microbilancia XA 21/52.5Y.M.A.P
Microbilancia XA 21.5Y.M.A.P
Microbilancia XA 52.5Y.M.A.P
Microbilancia XA 53.5Y.M.A.P
Select all
Vista
Salva
Aggiungere a confrontare
Caratteristiche generali

Microbilancia XA 6/21.5Y.M.A.P
per la calibrazione delle pipette

 
Le microbilance XA 5Y.M.A.P sono utilizzate per calibrare pipette monocanale da 0,5 µl. La calibrazione delle pipette è un altro modo per verificare che la pipetta prelevi quanto dovrebbe e quindi che il risultato della misura sia entro i limiti dell'errore accettabile. Le microbilance XA 5Y.M.A.P hanno le stesse caratteristiche delle microbilance XA 5Y.M.A, ma essendo progettate per la calibrazione delle pipette, sono dotate di un accessorio automatico per la calibrazione delle pipette, che comprende un adattatore per la calibrazione delle pipette, una cortina di vapore e un recipiente di vetro (abbiamo elencato tutti i componenti dell'accessorio per la calibrazione di seguito, accanto ai dati tecnici).
 
 
 

Camera di pesata completamente antistatica

Le microbilance XA 5Y.M.A.P sono dotate di uno ionizzatore antistatico incorporato e di una camera di pesata ad apertura automatica. Lo ionizzatore antistatico incorporato neutralizza la carica elettrostatica del campione durante ogni procedura di pesata, cioè ad ogni apertura della camera. La camera di pesata ad apertura automatica è controllata da un gesto, cioè senza contatto.
 
 
 
 
 
Avete bisogno di una bilancia che non solo determini il peso con una precisione impressionante, ma che esegua anche una verifica digitale, risponda ai vostri comandi vocali e vi invii messaggi luminosi?
 
In tal caso, scoprite le funzionalità della serie di bilance ELLIPSIS:
 
 

Digital Weighing Auditor

garantisce che la bilancia sia pronta all'uso. Consente di compensare lo spostamento d'aria in tempo reale. Inoltre, vi informerà quando è necessario revisionare la bilancia o verificare periodicamente l'accuratezza e la sensibilità della bilancia.
 
 
 

Display da 10

Uno schermo più grande (10'') significa più informazioni in un unico posto. Sul nuovo terminale ELLIPSIS potrete vedere fino a 3 schermate, widget, grafici, statinote e una comoda cronologia delle misure.
 
 
 

Ambient Light – un modo innovativo per la bilancia di comunicare con l'utente

Il colore della retroilluminazione indica lo stato, i risultati del processo, le procedure o gli avvisi.
 
 
 
 

Verifica dell'utente senza compromessi

Per la prima volta in assoluto, la bilancia verifica l'utente utilizzando una password, una scheda RFID, un lettore di impronte digitali, un meccanismo di riconoscimento facciale o una qualsiasi combinazione di questi elementi.
 
 
 

Hotspot

Utilizzate la bilancia su qualsiasi dispositivo ad essa collegato. Può trattarsi di smartphone, tablet o computer.
 
 
 

Live Note – annota le tue scoperte

Per la prima volta, potrete aggiungere una nota vocale a una serie di misurazioni o a un rapporto di procedura. Se si preferisce scrivere,
ELLIPSIS consente di aggiungere una nota di testo.
 
 
 

RFID

ELLIPSIS funziona con tag RFID*, che possono essere utilizzati per etichettare le merci o gli ingredienti delle ricette nel database. Inoltre, possono essere utilizzati per l'identificazione degli utenti.
 
 
 

Handy Library

Qui è possibile visualizzare una serie di misurazioni recenti o un report pronto per la firma digitale, in conformità con la normativa 21 CFR Parte 11.
 
 
 

Widget

Pronti a visualizzare ciò che vi serve di più al momento.
 
 
 

Smart Min Weight

La bilancia visualizza se il valore del peso che si desidera pesare è inferiore o superiore alla soglia di peso minimo.
 
 
 

Livellamento automatico del sistema ReflexLEVEL

Invece di livellare manualmente la bilancia, livellatela automaticamente. Il sistema ReflexLEVEL consente di risparmiare tempo e di ottenere la massima precisione di misurazione.
 
 
 

21 CFR Parte 11

Lavorate nell'industria farmaceutica? Avete bisogno di una firma digitale?

Offriamo una bilancia da laboratorio che, come dispositivo indipendente, soddisfa i requisiti della norma 21 CFR Parte 11/ EU GMP Annex 11.
 
 Sicurezza totale dei dati
 Firma elettronica
 Convalide
 Registrazioni elettroniche
 Tracce di controllo
 
 
 

Modbus TCP/IP

è uno dei protocolli di comunicazione più diffusi nell'automazione industriale. La sua implementazione nelle bilance 5Y e CY10 rende i dispositivi di questa serie di facile utilizzo per gli integratori di automazione. 
 
In un sistema Modbus, la bilancia è uno slave ed esegue i compiti definiti dal master, che di solito è un PLC. Il protocollo Modbus TCP/IP delle bilance 5Y e C10 consente, tra l'altro, di realizzare le funzioni di lettura del peso, azzeramento e tara, nonché di impostare la tara e le soglie MIN e MAX.

 
 
 
 

Regolazione a due punti

La regolazione, che avviene su due punti di misura anziché su uno, aumenta la precisione di misurazione sull'intero intervallo di pesatura. Cosa significa questo per voi? Misurazione più accurata.
 
 
* RFID ISO/IEC 14443 tipo A, 13,56 MHz
 
 
Specifiche
Portata massima [Max]

6 / 21

 g

Portata minima [Min]

0,1

 mg

Divisione [d]

1 / 2

 µg

Intervallo di verifica della bilancia [e]

1

 mg

Campo di tara

-21

 g

Ripetibilità standard [5% Max]

1,3

 µg

Ripetibilità standard [Max]

3,5

 µg

Peso standard minimo (USP)

2,6

 mg

Peso standard minimo (U = 1%, k = 2)

0,26

 mg

Ripetibilità consentita [5% massimo]

2

 µg

Ripetibilità consentita [Max]

5

 µg

Linearità

±9

 µg

Carico decentrato

15

 µg

Sensibilita stabilita

1×10⁻⁶/Year×Rt

 

Tempo di stabilizzazione

~ 3,5

 s

Calibrazione

internal (automatic)

 

Classe OIML

I

 

Sistema di livellamento

automatic – Reflex Level System

 

Display

10″ graphic colour touchscreen

 

Porta della camera di pesatura

automatic

 

Componenti del kit

Microbalance, weighing pan, weighing pan shield, power supply, automatic pipette calibration adapter: (base, bottom ring, glass vessel, pipette calibration adapter, evaporation ring, weighing pan, glass lid, mechanical closing cover, protecting screw), brush, fabric dust cover.

 

Dimensioni della camera di pesata

199×170×217

 mm

Capacità

11 ml

 

Dimensione piatto

ø26

 mm

Dimensioni del pacco

750×492×595

 mm

Peso netto

14,5

 kg

Peso lordo

18,9

 kg

Punteggio IP

IP 43

 

Interfaccia

2×USB-A, USB-C, HDMI, Ethernet, Wi-Fi®, Hotspot

 

Alimentatore

Adapter: 100 – 240V AC 50/60Hz 1A; 15V DC 2,4A
Balance: 12 – 15V DC 1,4A max*

 

Ambiente di lavoro

+10 – +40

 °C

Velocita di variazione della temperatura

±0,3 °C / 1 h (±1 °C / 8 h)

 

Umidità relativa

40% – 80%

 

Velocita di variazione della umidità relativa

±1% / h (±4% / 8 h)

 

CE
Verifica Extra payment
for verification
Garanzia 5 anni
La ripetibilità è espressa come deviazione standard di 10 posizionamenti dello standard di massa.
Il tempo di stabilizzazione dipende dalle condizioni esterne e dalla dinamica di posizionamento del carico sul piatto; specificato per il profilo FAST. 
* L'alimentazione può essere collegata alla presa sul retro dell'alloggiamento della bilancia o al terminale.
360°

Video
5Y Functions: Animal Weighing
5Y Functions: Statistics
5Y Functions: DWA®
5Y Balance and Barcode Scanner – Easy Connection
New Menu Language in 5Y Series Balances: Japanese
5Y Functions: Checkweighing
5Y Functions: Dosing
5Y Functions: Formulations
Percentage deviations
5Y Functions: Weighing
5Y Functions: Parts counting
5Y Functions: Proximity Sensors – Touch-Free Control (Tutorial)
5Y Functions: GLP Procedures – Objective Documentation of Measurements (Tutorial)
Weighing Printout Design in Analytical and Precision Balances (Tutorial)
Stampa facile con l’RTP-UEW80 con Wi-Fi®®
ELLIPSIS – New Balance by RADWAG
ELLIPSIS – Cutting Edge, Innovative, New
Talk to it. Voice Commands in New ELLIPSIS Balance by RADWAG
310 ELLIPSIS – Scan or Tap to Log In
Remote VPN Support on ELLIPSIS Balances
ELLIPSIS – Unlimited Connections
Connecting RADWAG RTP-UEW80 Printer via Wi-Fi® (Tutorial)
XA 5Y.M Unpacking and Installation (Tutorial)
RTP - The First Receipt Printer of RADWAG Production!
Complete Solutions for Mass Measurement in Pharma Industry
New AS and PS 5Y Balances – Autotest (Tutorial)
Funzioni
Autotest

Autotest

Diagnostic function aiming at metrological parameters determination (repeatability), the parameters are determined for the actual conditions of use. When speaking of repeatability it may be also used for weighing time optimization. Autotest is operated in an automatic mode thus operator’s time is saved.
Percent Weighing

Percent Weighing

Percent Weighing function is used for comparision of measured products with mass standard. Mass of a mass standard may be a numeric value taken from a database or it may be determined through a measurement process. Each measured product is compared to mass standard, mass of which is presumed as a model 100% ideal mass. For products weighing less than the mass standard, obtained results are lower than 100%, for products weighing more, the obtained results are greatly  exceeded.
Peak hold

Peak hold

Function registering the greatest temporary indication occurring in course of the weighing process. It is most often used in medical scales in order to hold the measurement indication.
Statistics

Statistics

Statistiscs function registers and analyses performed measurements. This supplies the user withthe following information: Max and Min standard deviation, average value, variance, range et.
IR sensors

IR sensors

Programmable function supporting the weighing process through control of the following options: sliding weighing chamber doors, printout, zeroing, tarring etc. Especially appreciated wherever preventing the balance from soiling is important.
GLP Procedures

GLP Procedures

Diagnostic function allowing to objectively document performed measurements. GLP procedures may be either presented in a short report form or extended one.
Pipettes Calibration

Pipettes Calibration

Function verifying correctness of piston pipettes functioning, the verification is performed via gravimetric measurement of the excreted liquid. Pipettes calibration may be either a stand-alone module or it may be operated
Air density correction

Air density correction

Function performing correction of mass measurement indication, wherein the air density is taken into account. It is used in balances with reading unit < 0,01 mg.
Automatic sliding door

Automatic sliding door

Automatic side panes opened via touch-free IR sensors.
Moveable range

Moveable range

Dual range analytical balances can be equipped with much more precise measuring range but only in very limited part of max capacity and only from zero load. A new technology introduced by RADWAG allows for moving this limited range till max capacity of the balance is reached. Such solution has been named as: Moveable range.
Differential weighing

Differential weighing

Differential weighing informs about mass variation a particular sample, wherein the said variation is a result of manufacturing processes.

Differential weighing is often applied in product control process, for which reference product parameters have been specified in order to be used as a source of comparison for the whole series.
Insuchcasestandard deviation is the information which tells about quality and completeness of a final product. For systems based on a feed-back technique such information may be used by control units.
Ambient conditions monitoring

Ambient conditions monitoring

The possibility of cooperation with the THBR 2.0 system
Replaceable unit

Replaceable unit

Replaceable units.
Statistical Quality Control

Statistical Quality Control

Statistical control for determination of basic statistical criteria: maximum, minimum, standard deviation, mean values for each batch, etc.
ALIBI Memory

ALIBI Memory

"ALIBI" memory enables saving and storing up to 100000 measurements.  Measurements are saved automatically upon each pressing of the key. There is no need for any additional operations or changing settings.
The following data related with the measurements is saved: measurement date; measurement time; result (mass); tare value; operator carrying out the measurement (logged in); product name.
The software saves the measurement in a so called loop, i.e. when the measurement no. 100001 is saved, the measurement 1 gets automatically deleted from the memory.
Measurements saved to balance memory cannot be deleted.
You can preview and print out the data saved to the ALIBI database.
Wi-Fi®

Wi-Fi®

Thanks to wireless communication between the computer and a balance, it is possible to use a balance inside a laminar flow hood and a fume cupboard.

Documentazione
Data Sheet Data Sheet
Data Sheet

Vista
Vista
Salva
Salva

Choose more product:
Vista Vista SalvaSalva
User Manual
User Manual
Vista
Vista
Salva
Salva
(2.36 MB)
User Manual
User Manual
Vista
Vista
Salva
Salva
(1.24 MB)
Software Manual
Software Manual
Vista
Vista
Salva
Salva
(1.23 MB)
User Manual
User Manual
Vista
Vista
Salva
Salva
(13.23 MB)
Start up Guide
Start up Guide
Vista
Vista
Salva
Salva
(4.76 MB)
Software Manual
Software Manual
Vista
Vista
Salva
Salva
(0.95 MB)
Conformity Declarations
Conformity Declarations
Vista
Vista
Salva
Salva
(0.04 MB)
Laboratory balance cleaning
Laboratory balance cleaning
Vista
Vista
Salva
Salva
(2.52 MB)
RTP Thermal Receipt Printer
RTP Thermal Receipt Printer
Vista
Vista
Salva
Salva
(1.64 MB)
Lexicon of Basic Metrological Terms
Lexicon of Basic Metrological Terms
Vista
Vista
Salva
Salva
(6.31 MB)
RFID
RFID
Vista
Vista
Salva
Salva
(0.68 MB)
Hybrid Protective Glass
Hybrid Protective Glass
Vista
Vista
Salva
Salva
(1.86 MB)
Micro Scale Measurement
Micro Scale Measurement
Vista
Vista
Salva
Salva
(2.74 MB)
Laboratory Balances
Laboratory Balances
Vista
Vista
Salva
Salva
(1.68 MB)
Metrology in the laboratory 2024
Metrology in the laboratory 2024
Vista
Vista
Salva
Salva
(5.65 MB)
Checking and calibrating fixed volume and adjustable volume piston pipettes using a gravimetric method
Checking and calibrating fixed volume and adjustable volume piston pipettes using a gravimetric method
Vista
Vista
Salva
Salva
(5.49 MB)
Weighing systems for calibration  and verification of piston pipettes
Weighing systems for calibration and verification of piston pipettes
Vista
Vista
Salva
Salva
(5.27 MB)
ELLIPSIS 5Y Laboratory Balances
ELLIPSIS 5Y Laboratory Balances
Vista
Vista
Salva
Salva
(33.90 MB)
Accessori
Tag RFID

Accessori

Radwag bilance e sistemi di pesatura
Torunska 5
26-600 Radom
Poland
tel.: +48 48 386 60 00
e-mail: export@radwag.com
TIN: PL7960000327
Vimeo Radwag YouTube Radwag Facebook Radwag LinkedIn Radwag
© 2024 Radwag bilance e sistemi di pesatura. Diritti riservati

selezionare

×
Change language AlbanianAlbanian
Change language DanishDanish
Change language NederlandseNederlandse
Change language EstonianEstonian
Change language FinnishFinnish
Change language HungarianHungarian
Change language IcelandicIcelandic
Change language KazakhKazakh
Change language LatvianLatvian
Change language LithuanianLithuanian
Change language MacedonianMacedonian
Change language NorwegianNorwegian
Change language PortuguesePortuguese
Change language RomanianRomanian
Change language RussianRussian
Change language SlovakSlovak
Change language SlovenianSlovenian
Change language SwedishSwedish
Change language UkrainianUkrainian
Change language SerbianSerbian
Change language MontenegrinMontenegrin
Change language page on Deutsch Deutsch
Change language page on English English
Change language page on Español Español
Change language page on Français Français
Change language page on Polski Polski
Change language page on Türkiye Türkiye
Česky
Português (Brasil)
Change website to USA USA
Change language page on 中文 中文
Presentations Presentations Presentations
Subscribe Subscribe Subscribe
Radwag in Facebook Radwag in Facebook Facebook
Radwag in YouTube Radwag in YouTube Youtube
Radwag in Vimeo Radwag in Vimeo Vimeo
Radwag in LinkedIn Radwag in LinkedIn LinkedIn
Webinars Radwag Webinars Radwag Webinars
close
E-mail
nome azienda:
Nome:
I consent to the processing of my personal data for marketing purposes by Radwag Wagi Elektroniczne Witold Lewandowski.
I consent to receive marketing and product-related messages by electronic means from Radwag Wagi Elektroniczne Witold Lewandowski.
I have read the Privacy Policy of RADWAG Wagi Elektroniczne Witold Lewandowski.
lock_openI want to access the files
close
Slide to go back ↩