Bilancia analitica XA 210.5Y.A

Radwag Bilance e sistemi di pesatura
Selected language Italiano
Obraz
This image is for reference only.

Bilancia analitica XA 210.5Y.A

Codice prodotto: WL-110-0003
Modifica del modello (11)
done
Max: 210gd: 0,01mg

 ø90 open-work pan + ø85 (option)mm
expand_more
Max: 41 / 120gd: 0,002 / 0,005mg

 ø64mm
Max: 52gd: 0,01mg

 ø90 open-work pan + ø85 (option)mm
Max: 82 / 220gd: 0,01 / 0,1mg

 ø90 open-work pan + ø85 (option)mm
Max: 110gd: 0,01mg

 ø90 open-work pan + ø85 (option)mm
Max: 120 / 250gd: 0,01 / 0,1mg

 ø90 open-work pan + ø85 (option)mm
Max: 121 / 220gd: 0,005 / 0,01mg

 ø78mm
Max: 220gd: 0,1mg

 ø100mm
Max: 310gd: 0,1mg

 ø100mm
Max: 320gd: 0,05mg

 ø90 open-work pan + ø85 (option)mm
Max: 520gd: 0,1mg

 ø100mm
Portata massima [Max]: 210 g
Divisione [d]: 0,01 mg

close
Modifica del modello:
Bilancia analitica XA 41/120.5Y.A
Bilancia analitica XA 52.5Y.A
Bilancia analitica XA 82/220.5Y.A
Bilancia analitica XA 110.5Y.A
Bilancia analitica XA 120/250.5Y.A
Bilancia analitica XA 121/220.5Y.A
Bilancia analitica XA 210.5Y.A
Bilancia analitica XA 220.5Y.A
Bilancia analitica XA 310.5Y.A
Bilancia analitica XA 320.5Y.A
Bilancia analitica XA 520.5Y.A
Select all
Vista
Salva
Aggiungere a confrontare
Caratteristiche generali

Bilancia analitica XA 210.5Y.A

 
Avete bisogno di una bilancia che non solo determini il peso con una precisione impressionante, ma che esegua anche una verifica digitale, risponda ai vostri comandi vocali e vi invii messaggi luminosi?
 
In tal caso, scoprite le funzionalità della serie di bilance ELLIPSIS:
 
 
 

Le bilance analitiche XA 5Y.A

sono strumenti di laboratorio avanzati che combinano la tecnologia moderna con una precisione di misura senza pari. Dotate di un innovativo sistema di misurazione, offrono un ampio intervallo di pesata e un'elevata precisione, che le rendono ideali per i laboratori analitici, farmaceutici e chimici.
 
 
 

Digital Weighing Auditor

garantisce che la bilancia sia pronta all'uso. Consente di compensare lo spostamento d'aria in tempo reale. Inoltre, vi informerà quando è necessario revisionare la bilancia o verificare periodicamente l'accuratezza e la sensibilità della bilancia.
 
 
 
 
 

Display da 10

Uno schermo più grande (10'') significa più informazioni in un unico posto. Sul nuovo terminale ELLIPSIS potrete vedere fino a 3 schermate, widget, grafici, stati, note e una comoda cronologia delle misure.
 
 
 

Verifica dell'utente senza compromessi

Per la prima volta in assoluto, la bilancia verifica l'utente utilizzando una password, una scheda RFID, un lettore di impronte digitali, un meccanismo di riconoscimento facciale o una qualsiasi combinazione di questi elementi.
 
 
 

Ambient Light – un modo innovativo per la bilancia di comunicare con l'utente

Il colore della retroilluminazione indica lo stato, i risultati del processo, le procedure o gli avvisi.
 
 
 
 

Hotspot

Utilizzate la bilancia su qualsiasi dispositivo ad essa collegato. Può trattarsi di smartphone, tablet o computer.
 
 
 

RFID

ELLIPSIS funziona con tag RFID*, che possono essere utilizzati per etichettare le merci o gli ingredienti delle ricette nel database. Inoltre, possono essere utilizzati per l'identificazione degli utenti.
 
 
 

Live Note – annota le tue scoperte

Per la prima volta, potrete aggiungere una nota vocale a una serie di misurazioni o a un rapporto di procedura. Se si preferisce scrivere, ELLIPSIS consente di aggiungere una nota di testo.
 
 
 

Handy Library

Qui è possibile visualizzare una serie di misurazioni recenti o un report pronto per la firma digitale, in conformità con la normativa 21 CFR Parte 11.
 
 
 

Widget

Pronti a visualizzare ciò che vi serve di più al momento.
 
 
 

Livellamento automatico del sistema ReflexLEVEL

Invece di livellare la bilancia manualmente, livellatela automaticamente. Il sistema ReflexLEVEL fa risparmiare tempo, garantisce il perfetto posizionamento del sistema di misura e offre la massima precisione di misurazione.
 
 
 

Smart Min Weight

La bilancia visualizza se il valore del peso che si desidera pesare è inferiore o superiore alla soglia di peso minimo.
 
 
 

Antistatico nella camera di pesata

Avete un campione che potrebbe essere caricato elettrostaticamente? 
Lo ionizzatore antistatico integrato neutralizza la carica elettrostatica del campione durante qualsiasi procedura di pesata. È integrato nello strumento, eliminando la necessità di apparecchiature aggiuntive e semplificando la gestione dell'antistatico in un unico luogo.
 
Come migliorerete l'accuratezza del risultato della pesata?  La garanzia è data dallo speciale rivestimento antistatico del vetro, che compensa le cariche elettrostatiche presenti sul campione e sugli accessori di laboratorio, eliminando così gli errori di misura. La minore deposizione di polvere e sporcizia può prolungare la durata dei componenti ottici ed elettronici in prossimità delle lastre di vetro.
 
 
 

21 CFR Parte 11

Lavorate nell'industria farmaceutica? Avete bisogno di una firma digitale?
 
Offriamo una bilancia da laboratorio che, come dispositivo indipendente, soddisfa i requisiti della norma 21 CFR Parte 11/ EU GMP Annex 11.
 
– Sicurezza totale dei dati
– Firma elettronica
 Convalide
 Registrazioni elettroniche
 Tracce di controllo
 
 
 

Modbus TCP/IP

è uno dei protocolli di comunicazione più diffusi nell'automazione industriale. La sua implementazione nelle bilance 5YCY10 rende i dispositivi di questa serie di facile utilizzo per gli integratori di automazione. 
 
In un sistema Modbus, la bilancia è uno slave ed esegue i compiti definiti dal master, che di solito è un PLC. Il protocollo Modbus TCP/IP delle bilance 5Y e C10 consente, tra l'altro, di realizzare le funzioni di lettura del peso, azzeramento e tara, nonché di impostare la tara e le soglie MIN e MAX.


 
 
 
 

Regolazione a due punti

La regolazione, che avviene su due punti di misura anziché su uno, aumenta la precisione di misurazione sull'intero intervallo di pesatura. Cosa significa questo per voi? Misurazione più accurata.
 
 
* RFID ISO/IEC 14443 tipo A, 13,56 MHz
 
 
 
Specifiche
Portata massima [Max]

210

 g

Portata minima [Min]

1

 mg

Divisione [d]

0,01

 mg

Intervallo di verifica della bilancia [e]

1

 mg

Campo di tara

-210

 g

Ripetibilità standard [5% Max]

0,005

 mg

Ripetibilità standard [Max]

0,025

 mg

Peso standard minimo (USP)

10

 mg

Peso standard minimo (U = 1%, k = 2)

1

 mg

Ripetibilità consentita [5% massimo]

0,012

 mg

Ripetibilità consentita [Max]

0,035

 mg

Linearità

±0,1

 mg

Carico decentrato

0,1

 mg

Sensibilita stabilita

1×10⁻⁶/Year×Rt

 

Tempo di stabilizzazione

4

 s

Calibrazione

internal (automatic)

 

Classe OIML

I

 

Sistema di livellamento

automatic – Reflex Level System

 

Display

10″ graphic colour touchscreen

 

Camera di pesatura

automatic

 

Porta della camera di pesatura

automatic

 

Componenti del kit

Analytical Balance, weighing pan, weighing pan shield, centring ring, brush, fabric dust cover, power supply.

 

Dimensioni della camera di pesata

200×170×220

 mm

Dimensione piatto

ø90 open-work pan + ø85 (option)

 mm

Dimensioni del pacco

750×492×595

 mm

Peso netto

14,7

 kg

Peso lordo

20

 kg

Punteggio IP

IP 43

 

Interfaccia

2×USB-A, USB-C, HDMI, Ethernet, Wi-Fi®, Hotspot

 

Alimentatore

Adapter: 100 – 240V AC 50/60Hz 1A; 15V DC 2,4A
Balance: 12 – 15V DC 1,6A max*

 

Ambiente di lavoro

+10 – +40

 °C

Velocita di variazione della temperatura

±0,3 °C / 1 h (±1 °C / 8 h)

 

Umidità relativa

20% – 80%

 

Velocita di variazione della umidità relativa

±1% / h (±4% / 8 h)

 

CE
Verifica Extra payment
for verification
Garanzia 5 anni
La ripetibilità è espressa come deviazione standard di 10 posizionamenti dello standard di massa.
Il tempo di stabilizzazione dipende dalle condizioni esterne e dalla dinamica di posizionamento del carico sul piatto; specificato per il profilo FAST. 
* L'alimentazione può essere collegata alla presa sul retro dell'alloggiamento della bilancia o al terminale.
360°
Video
Precision and Working Comfort – Operating RADWAG Balances in Every Glove!
5Y Functions: Animal Weighing
5Y Functions: Statistics
5Y Functions: DWA®
5Y Balance and Barcode Scanner – Easy Connection
New Menu Language in 5Y Series Balances: Japanese
5Y Functions: Checkweighing
5Y Functions: Dosing
5Y Functions: Formulations
Percentage deviations
5Y Functions: Weighing
5Y Functions: Parts counting
5Y Functions: Proximity Sensors – Touch-Free Control (Tutorial)
5Y Functions: GLP Procedures – Objective Documentation of Measurements (Tutorial)
Weighing Printout Design in Analytical and Precision Balances (Tutorial)
Stampa facile con l’RTP-UEW80 con Wi-Fi®®
ELLIPSIS – New Balance by RADWAG
ELLIPSIS – Cutting Edge, Innovative, New
Talk to it. Voice Commands in New ELLIPSIS Balance by RADWAG
310 ELLIPSIS – Scan or Tap to Log In
Remote VPN Support on ELLIPSIS Balances
ELLIPSIS – Unlimited Connections
Connecting RADWAG RTP-UEW80 Printer via Wi-Fi® (Tutorial)
XA 5Y.M Unpacking and Installation (Tutorial)
RTP - The First Receipt Printer of RADWAG Production!
Complete Solutions for Mass Measurement in Pharma Industry
New AS and PS 5Y Balances – Autotest (Tutorial)
Funzioni
Autotest

Autotest

Diagnostic function aiming at metrological parameters determination (repeatability), the parameters are determined for the actual conditions of use. When speaking of repeatability it may be also used for weighing time optimization. Autotest is operated in an automatic mode thus operator’s time is saved.
Dosing

Dosing

Weighing process for which reference mass has been determined together with tolerance for its determination. Dosing tolerance is given in [%] and it is calculated in relation to the reference value thus being a permissible deviation of this process. This solution is used for weighing powders, liquids and loose materials. Dosing function performance is often supported with bargraph - load indicator. For industrial scales it is possible to use a control systems of dosing process.
Percent Weighing

Percent Weighing

Percent Weighing function is used for comparision of measured products with mass standard. Mass of a mass standard may be a numeric value taken from a database or it may be determined through a measurement process. Each measured product is compared to mass standard, mass of which is presumed as a model 100% ideal mass. For products weighing less than the mass standard, obtained results are lower than 100%, for products weighing more, the obtained results are greatly  exceeded.
Parts counting

Parts counting

Function using mass measurement for determination of  measured items quantity. Mass of a single item is required for this process. It may be either estimated through weighment or taken from a database. For items counting the following algorithm is used: all items mass / single item mass = quantity. Function operation is supperted by a mechanism of Automatic Correction of Accuracy. This allows to update single item mass in course of the process. To a certain extend Automatic Correction of Accuracy eliminates error which may be a result of different mass values of seemingly alike single elements. For industry solutions items counting may be simultaneously carried out with checkweighing and dosing thus industry solutions feature audio signalling base informing that specified number of items has been weighed. It is possible to apply weighing systems using few platfroms of different MAX capacities and different accuracies.
Peak hold

Peak hold

Function registering the greatest temporary indication occurring in course of the weighing process. It is most often used in medical scales in order to hold the measurement indication.
Formulation

Formulation

Function supporting the mixture making process, wherein the mixture contains various components. Formulation function usually uses the balance/scale database of components. Formulation serves for monitored checkweighing of every single component with a given tolerance. It is enriched with a set of individual settings.
Statistics

Statistics

Statistiscs function registers and analyses performed measurements. This supplies the user withthe following information: Max and Min standard deviation, average value, variance, range et.
Checkweighing

Checkweighing

Checkweighing function is used for checking whether the measured sample mass is within the predefined threshold values, Low [LO] and Hgh [HI]. The thresholds are given in [g] and [kg] units. Current state of a sample being measured is signalled by means of pictorgams located on a display for laboratory balances, for industrial scales Stackligt System is used. This visual +/- inspection is in operation during segregation, control or packing process of products for which mass has bees determined with a specifaied tolerance, eg. 12860 g 961
IR sensors

IR sensors

Programmable function supporting the weighing process through control of the following options: sliding weighing chamber doors, printout, zeroing, tarring etc. Especially appreciated wherever preventing the balance from soiling is important.
Under-pan weighing

Under-pan weighing

The solution enables weighing with use of a stand, which is advisable for loads of non-standard shapes and dimensions and those that generate magnetic field.
GLP Procedures

GLP Procedures

Diagnostic function allowing to objectively document performed measurements. GLP procedures may be either presented in a short report form or extended one.
Animal weighing

Animal weighing

Process of mass determination for a product which may unwillingly reposition within the weighing pan. Mass determination in such cases requires much longer period of time when compared to typical weighing process. It is the user who defines period of time needed for control of measured product mass. The user can thus optimize the function depending on the measured product characteristics.
Pipettes Calibration

Pipettes Calibration

Function verifying correctness of piston pipettes functioning, the verification is performed via gravimetric measurement of the excreted liquid. Pipettes calibration may be either a stand-alone module or it may be operated
Air density correction

Air density correction

Function performing correction of mass measurement indication, wherein the air density is taken into account. It is used in balances with reading unit < 0,01 mg.
Automatic sliding door

Automatic sliding door

Automatic side panes opened via touch-free IR sensors.
Density determination

Density determination

Liquid or solid body density function uses the Archimedes principle and it requires a special kit to be applied. The kit when used, replaces a weighing pan. For solids mass of the sample must be determined first in the air, next in the liquid of specified density. For liquids the so called sinker, density of which has been determined, must be measured first in the air, next in the tested liquid. The density determination process is disturbed by air bubbles which may stick either to the measured sample or the sinker. In case of laboratory equipment very light solids may be measured. For industry, solid bodies density may be determined by means of  under-pan weighing. Tested load of significant size may be measured this way.
Differential weighing

Differential weighing

Differential weighing informs about mass variation a particular sample, wherein the said variation is a result of manufacturing processes.

Differential weighing is often applied in product control process, for which reference product parameters have been specified in order to be used as a source of comparison for the whole series.
Insuchcasestandard deviation is the information which tells about quality and completeness of a final product. For systems based on a feed-back technique such information may be used by control units.
Ambient conditions monitoring

Ambient conditions monitoring

The possibility of cooperation with the THBR 2.0 system
Statistical Quality Control

Statistical Quality Control

Statistical control for determination of basic statistical criteria: maximum, minimum, standard deviation, mean values for each batch, etc.
Packaged Goods Control

Packaged Goods Control

Pre-packaged Goods Control mode enables to collect weighings from RADWAG-designed weighing instruments, carry out control and generate PGC reports. Different types of weighing instruments can be combined into a network. The control can be started on a balance or via computer software. It is automatically finished after a respective quantity of packages is verified.
Collected data allows you to assess quality of produced pre-packaged goods and their conformity with:
- internal quality control system;
- 'Pre-Packaged Goods' regulation of 7th May 2009 (Journal of Laws No 91, item 740), on the requirements concerning quantity inspection of pre-packaged goods control, which inspection is to be carried out by means of random selection of the measurements results and sending those results to pre-packaged goods control procedure.
ALIBI Memory

ALIBI Memory

"ALIBI" memory enables saving and storing up to 100000 measurements.  Measurements are saved automatically upon each pressing of the key. There is no need for any additional operations or changing settings.
The following data related with the measurements is saved: measurement date; measurement time; result (mass); tare value; operator carrying out the measurement (logged in); product name.
The software saves the measurement in a so called loop, i.e. when the measurement no. 100001 is saved, the measurement 1 gets automatically deleted from the memory.
Measurements saved to balance memory cannot be deleted.
You can preview and print out the data saved to the ALIBI database.
Wi-Fi®

Wi-Fi®

Thanks to wireless communication between the computer and a balance, it is possible to use a balance inside a laminar flow hood and a fume cupboard.

Documentazione
Data Sheet Data Sheet
Data Sheet

Vista
Vista
Salva
Salva

Choose more product:
Vista Vista SalvaSalva
User Manual
User Manual
Vista
Vista
Salva
Salva
(2.36 MB)
User Manual
User Manual
Vista
Vista
Salva
Salva
(1.24 MB)
Software Manual
Software Manual
Vista
Vista
Salva
Salva
(1.23 MB)
User Manual
User Manual
Vista
Vista
Salva
Salva
(13.23 MB)
Start up Guide
Start up Guide
Vista
Vista
Salva
Salva
(4.76 MB)
Software Manual
Software Manual
Vista
Vista
Salva
Salva
(0.95 MB)
Conformity Declarations
Conformity Declarations
Vista
Vista
Salva
Salva
(0.04 MB)
Laboratory balance cleaning
Laboratory balance cleaning
Vista
Vista
Salva
Salva
(2.52 MB)
RTP Thermal Receipt Printer
RTP Thermal Receipt Printer
Vista
Vista
Salva
Salva
(1.64 MB)
Lexicon of Basic Metrological Terms
Lexicon of Basic Metrological Terms
Vista
Vista
Salva
Salva
(6.31 MB)
RFID
RFID
Vista
Vista
Salva
Salva
(0.68 MB)
Hybrid Protective Glass
Hybrid Protective Glass
Vista
Vista
Salva
Salva
(1.86 MB)
Laboratory Balances
Laboratory Balances
Vista
Vista
Salva
Salva
(1.68 MB)
Metrology in the laboratory 2024
Metrology in the laboratory 2024
Vista
Vista
Salva
Salva
(5.65 MB)
ELLIPSIS 5Y Laboratory Balances
ELLIPSIS 5Y Laboratory Balances
Vista
Vista
Salva
Salva
(33.90 MB)
Accessori
Tag RFID

Accessori

Newsletter

Subscribe to the newsletter if you would like to receive RADWAG news.

View more
Radwag bilance e sistemi di pesatura
Torunska 5
26-600 Radom
Poland
tel.: +48 48 386 60 00
e-mail: export@radwag.com
TIN: PL7960000327
Vimeo Radwag YouTube Radwag Facebook Radwag LinkedIn Radwag
© 2024 Radwag bilance e sistemi di pesatura. Diritti riservati

selezionare

×
Change language AlbanianAlbanian
Change language DanishDanish
Change language NederlandseNederlandse
Change language EstonianEstonian
Change language FinnishFinnish
Change language HungarianHungarian
Change language IcelandicIcelandic
Change language KazakhKazakh
Change language LatvianLatvian
Change language LithuanianLithuanian
Change language MacedonianMacedonian
Change language NorwegianNorwegian
Change language PortuguesePortuguese
Change language RomanianRomanian
Change language RussianRussian
Change language SlovakSlovak
Change language SlovenianSlovenian
Change language SwedishSwedish
Change language UkrainianUkrainian
Change language SerbianSerbian
Change language MontenegrinMontenegrin
Change language page on Deutsch Deutsch
Change language page on English English
Change language page on Español Español
Change language page on Français Français
Change language page on Polski Polski
Change language page on Türkiye Türkiye
Česky
Português (Brasil)
Change website to USA USA
Change language page on 中文 中文
Presentations Presentations Presentations
Subscribe Subscribe Subscribe
Radwag in Facebook Radwag in Facebook Facebook
Radwag in YouTube Radwag in YouTube Youtube
Radwag in Vimeo Radwag in Vimeo Vimeo
Radwag in LinkedIn Radwag in LinkedIn LinkedIn
Webinars Radwag Webinars Radwag Webinars
close
E-mail
nome azienda:
Nome:
I consent to the processing of my personal data for marketing purposes by Radwag Wagi Elektroniczne Witold Lewandowski.
I consent to receive marketing and product-related messages by electronic means from Radwag Wagi Elektroniczne Witold Lewandowski.
I have read the Privacy Policy of RADWAG Wagi Elektroniczne Witold Lewandowski.
lock_openI want to access the files
close
Slide to go back ↩