WPT 150/H4/K Waterproof Scale With Stainless Steel Load Cell

Product code: WP-105-0024
Information about conformity of a product with European Union regulations that concern the product. Marking the product with CE sign makes the manufacturer responsible for the product to meet requirements of general safety regulations determined by CE marking directives.
CE
CE
Information about conformity of a product with European Union regulations that concern the product. Marking the product with CE sign makes the manufacturer responsible for the product to meet requirements of general safety regulations determined by CE marking directives.
The procedure within the scope of Legal Metrology. It is performed by regional Offices of Measures or authorized entities before the new product is introduced to the market.  The procedure is performed on the basis of tests validating conformity of a product with the directives. For most measuring devices, including balances and scales, this procedure has been replaced with declaration of conformity.
CE
CE
Information about conformity of a product with European Union regulations that concern the product. Marking the product with CE sign makes the manufacturer responsible for the product to meet requirements of general safety regulations determined by CE marking directives.
Verification
Verification
The procedure within the scope of Legal Metrology. It is performed by regional Offices of Measures or authorized entities before the new product is introduced to the market. The procedure is performed on the basis of tests validating conformity of a product with the directives. For most measuring devices, including balances and scales, this procedure has been replaced with declaration of conformity.
CE
CE
Information about conformity of a product with European Union regulations that concern the product. Marking the product with CE sign makes the manufacturer responsible for the product to meet requirements of general safety regulations determined by CE marking directives.
Verification
Verification
The procedure within the scope of Legal Metrology. It is performed by regional Offices of Measures or authorized entities before the new product is introduced to the market. The procedure is performed on the basis of tests validating conformity of a product with the directives. For most measuring devices, including balances and scales, this procedure has been replaced with declaration of conformity.
2 years warranty
2 years warranty
Request for quotation

Overview

Maximum capacity [Max]: 150kg

Readability [d]: 50g


Waterproof platform scales is designed to operate in humid conditions and direct contact with water. 
 
The WPT/H series features LCD display and stainless steel weighing platform. All the elements of scales construction are made of stainless steel OH18N9.

The indicator PUE C/31H series is installed on a pillar. Optionally, the head is installed on a cable for hanging it on a wall.
 
Scales WPT/H series is powered from mains, RS 232 slot comes as standard. On client request, the waterproof platform scales can be manufactured with upgraded antirust coating.

Scales WPT/H series is available in dual range version on surcharge.
 

Functions

Plus/Minus Control

Plus/Minus Control

Control of sample's mass carried out with reference to specified MIN and MAX thresholds. The weight is considered to be correct if it is comprised within threshold values. A graphic visualisation of weighing result is displayed in a form of a bar graph.
Percent Weighing

Percent Weighing

Percent Weighing function is used for comparision of measured products with mass standard. Mass of a mass standard may be a numeric value taken from a database or it may be determined through a measurement process. Each measured product is compared to mass standard, mass of which is presumed as a model 100% ideal mass. For products weighing less than the mass standard, obtained results are lower than 100%, for products weighing more, the obtained results are greatly  exceeded.
Totalizing

Totalizing

Function adding new mass value to already obtained one. This allows to determine mass content of the mixture, being a composition of number of different consistence components. Totalizing is limited by maximum capacity parameter.
Parts counting

Parts counting

Function using mass measurement for determination of  measured items quantity. Mass of a single item is required for this process. It may be either estimated through weighment or taken from a database. For items counting the following algorithm is used: all items mass / single item mass = quantity. Function operation is supperted by a mechanism of Automatic Correction of Accuracy. This allows to update single item mass in course of the process. To a certain extend Automatic Correction of Accuracy eliminates error which may be a result of different mass values of seemingly alike single elements. For industry solutions items counting may be simultaneously carried out with checkweighing and dosing thus industry solutions feature audio signalling base informing that specified number of items has been weighed. It is possible to apply weighing systems using few platfroms of different MAX capacities and different accuracies.
Internal battery

Internal battery

Internal and rechargeable battery of SLA 6 V type (sealed lead acid) enables device operation without connecting the device to the mains (9h operation). The weighing instrument controls battery status and displays a respective pictogram on the screen.
Peak hold

Peak hold

Function registering the greatest temporary indication occurring in course of the weighing process. It is most often used in medical scales in order to hold the measurement indication.
Newton unit measurement

Newton unit measurement

Function allowing to perform the measurement in Newton unit, it may be used for processes aiming to determine force resulting in the sample damage.
Animal weighing

Animal weighing

Process of mass determination for a product which may unwillingly reposition within the weighing pan. Mass determination in such cases requires much longer period of time when compared to typical weighing process. It is the user who defines period of time needed for control of measured product mass. The user can thus optimize the function depending on the measured product characteristics.

Datasheet

Maximum capacity [Max] 150 kg
Readability [d] 50 g
Tare range - 150 kg
Operating temperature -10 ÷ +40 °C
Weighing pan dimensions 500×500 mm
Power supply 100 ÷ 240 V AC 50 ÷ 60 Hz / 12 V DC and battery 
Display LCD (backlit) 
Communication interface RS 232 
Packaging dimensions 840×600×400 mm
Protection class IP 67 construction, IP 68 (1h max)/69 indicator 
Operation time on batteries 45 h (average time) 
Atmospheric humidity 10÷85% RH no condensation 
OIML Class III 
Net weight/gross weight 23,5 / 25,8 kg

Documentation

Technical Documentation

User Manual
(1.89 MB) EN

Save
See the publication

Data Sheet
(0.84 MB) EN

Save
See the publication

Conformity Declaration
(0.04 MB) EN

Save
See the publication

Certificate of Health Quality
(0.43 MB) EN

Save
See the publication

Accessories

Granite Antivibration tables
Roller table
Scales Editor
R-LAB
RAD-KEY
LabVIEW Driver
Receipt printer
AP2-3 Power loop output
RS 232 cables (scale - EPSON printer)
RS 232, RS 485 cables
Cigarette lighter receptacle power supply cables
RS 232 cables (terminal - terminal)
Stands, wall mounting kits and mounting brackets
RS232 1339 Converter
Displays
Radwag Balances and Scales
Torunska 5
26-600 Radom
Poland
tel.: +48 48 386 63 03
e-mail: export@radwag.com
TIN: PL7960000327
Vimeo Radwag YouTube Radwag Facebook Radwag Google Plus Radwag
© 2018 RADWAG Balances and Scales. All rights reserved.

See our movies
RADWAG