Add to compare : C315.4.300.C6 Platform Scale

Selected language English English
Change language
Change language page on Deutsch DeutschChange language page on Español EspañolChange language page on Français FrançaisChange language page on Italiano ItalianoChange language page on Polski PolskiChange language page on Türkiye Türkiye ČeskyChange website to USA USAChange language page on 中文 中文

C315.4.300.C6 Platform Scale

C315.4.300.C6 Platform Scale - 4 series is made of mild steel powder coated construction of the weighing platform. The platform comprises 4 load cells connected to an indicator PUE C315 series featuring backlit LCD display and 5 function buttons
This image is for reference only.

Product code: WP-230-0002
Request for quotation

Overview

Maximum capacity [Max]: 300kg
Readability [d]: 0.1kg

Measurement with application of 4 load cells is a guarantee of precise

mass

reading, regardless of load positioning on the

weighing

platform. The platform

scales

C315.4 series is made of mild steel powder coated construction of the

weighing

platform. The platform comprises 4 load cells connected to an

indicator

PUE C315 series featuring backlit LCD display and 5 function buttons.

The weighing platform and the

indicator

are connected through a long cable enabling hanging the indicator on a wall.
The C315.4 series is available in pit version for easy placing heavy loads on the weighing platform without application of ramps.

Scales is  available in dual range version on surcharge.
 

Functions

Plus/Minus Control

Plus/Minus Control

Control of sample's mass carried out with reference to specified MIN and MAX thresholds. The weight is considered to be correct if it is comprised within threshold values. A graphic visualisation of weighing result is displayed in a form of a bar graph.
Percent Weighing

Percent Weighing

Percent Weighing function is used for comparision of measured products with mass standard. Mass of a mass standard may be a numeric value taken from a database or it may be determined through a measurement process. Each measured product is compared to mass standard, mass of which is presumed as a model 100% ideal mass. For products weighing less than the mass standard, obtained results are lower than 100%, for products weighing more, the obtained results are greatly  exceeded.
Totalizing

Totalizing

Function adding new mass value to already obtained one. This allows to determine mass content of the mixture, being a composition of number of different consistence components. Totalizing is limited by maximum capacity parameter.
Parts counting

Parts counting

Function using mass measurement for determination of  measured items quantity. Mass of a single item is required for this process. It may be either estimated through weighment or taken from a database. For items counting the following algorithm is used: all items mass / single item mass = quantity. Function operation is supperted by a mechanism of Automatic Correction of Accuracy. This allows to update single item mass in course of the process. To a certain extend Automatic Correction of Accuracy eliminates error which may be a result of different mass values of seemingly alike single elements. For industry solutions items counting may be simultaneously carried out with checkweighing and dosing thus industry solutions feature audio signalling base informing that specified number of items has been weighed. It is possible to apply weighing systems using few platfroms of different MAX capacities and different accuracies.
Internal battery

Internal battery

Internal and rechargeable battery of SLA 6 V type (sealed lead acid) enables device operation without connecting the device to the mains (9h operation). The weighing instrument controls battery status and displays a respective pictogram on the screen.
Peak hold

Peak hold

Function registering the greatest temporary indication occurring in course of the weighing process. It is most often used in medical scales in order to hold the measurement indication.
GLP Procedures

GLP Procedures

Diagnostic function allowing to objectively document performed measurements. GLP procedures may be either presented in a short report form or extended one.
Animal weighing

Animal weighing

Process of mass determination for a product which may unwillingly reposition within the weighing pan. Mass determination in such cases requires much longer period of time when compared to typical weighing process. It is the user who defines period of time needed for control of measured product mass. The user can thus optimize the function depending on the measured product characteristics.
ALIBI Memory

ALIBI Memory

"ALIBI" memory enables saving and storing up to 100000 measurements.  Measurements are saved automatically upon each pressing of the key. There is no need for any additional operations or changing settings.
The following data related with the measurements is saved: measurement date; measurement time; result (mass); tare value; operator carrying out the measurement (logged in); product name.
The software saves the measurement in a so called loop, i.e. when the measurement no. 100001 is saved, the measurement 1 gets automatically deleted from the memory.
Measurements saved to balance memory cannot be deleted.
You can preview and print out the data saved to the ALIBI database.

Datasheet

Maximum capacity [Max]

300

 kg

Minimum load

2

 kg

Readability [d]

0.1

 kg

Tare range

-300

 kg

OIML Class

III

 

Display

LCD (backlit)

 

Protection class

IP 65 construction, IP 43 indicator

 

RS232 Interface

1× standard, 1× option

 

Wi-Fi® Interface

1× standard

 

Power supply

100 ÷ 240 V AC 50 / 60 Hz and battery

 

Operation time on batteries

max 8h

 

Operating temperature

-10 ÷ +40

 °C

Relative humidity

10% ÷ 85% RH no condensation

 

Weighing pan dimensions

800×800

 mm

Weighing platform height

116 ±6

 mm

Scale mass with indicator

55

 kg

Documentation

Technical specification
Publications and teaching materials
User Manual
(0.98 MB)
Save See the publication
Manuals
(0.30 MB)
Save See the publication
Data Sheet
(1.08 MB)
Save See the publication
Conformity Declaration
(0.04 MB)
Save See the publication
C315 Platform Scales
(2.13 MB)
Save See the publication
Measuring_instruments_in_industry
(0.05 MB)
Save See the publication
Pit installation frame
(0.13 MB)
Save See the publication

Accessories

Scales Editor 2.0
RW Tool
R-LAB
RAD-KEY
LabVIEW Driver
Receipt printer
Ramps

Accessories

Product name

Overview

Ramp for WPT/4 C6 1500kg scale

The ramps are used to easily place the trolleys containing loads onto the 4 load cell platform scales. They enable placing the scale into the production line as ...

Ramp for WPT/4 C7 1500kg scale

The ramps are used to easily place the trolleys containing loads onto the 4 load cell platform scales. They enable placing the scale into the production line as ...

Ramp for WPT/4 C8 3000kg scale

The ramps are used to easily place the trolleys containing loads onto the 4 load cell platform scales. They enable placing the scale into the production line as ...

Ramp for WPT/4 C9 1500kg scale

The ramps are used to easily place the trolleys containing loads onto the 4 load cell platform scales. They enable placing the scale into the production line as ...

Ramp for WPT/4 C9 3000kg scale

The ramps are used to easily place the trolleys containing loads onto the 4 load cell platform scales. They enable placing the scale into the production line as ...

Ramp for WPT/4 C9 6000kg scale

The ramps are used to easily place the trolleys containing loads onto the 4 load cell platform scales. They enable placing the scale into the production line as ...

Ramp for WPT/4 C10 3000kg scale

The ramps are used to easily place the trolleys containing loads onto the 4 load cell platform scales. They enable placing the scale into the production line as ...

Ramp for WPT/4 C10 6000kg scale

The ramps are used to easily place the trolleys containing loads onto the 4 load cell platform scales. They enable placing the scale into the production line as ...

Ramp for WPT/4 C11 3000kg scale

The ramps are used to easily place the trolleys containing loads onto the 4 load cell platform scales. They enable placing the scale into the production line as ...

Ramp for WPT/4 C11 6000kg scale

The ramps are used to easily place the trolleys containing loads onto the 4 load cell platform scales. They enable placing the scale into the production line as ...

Cigarette lighter receptacle power supply cables
RS 232 cables (scale - EPSON printer)
RS 232, RS 485 cables
Stands, wall mounting kits and mounting brackets
Power loop output
RS232 1339 Converter
RS232 1345 Converter
Displays

Radwag Balances and Scales

Torunska 5
26-600 Radom
Poland
tel.: +48 48 386 60 00
e-mail: export@radwag.com
TIN: PL7960000327
Vimeo Radwag YouTube Radwag Facebook Radwag
© 2019 RADWAG Balances and Scales. All rights reserved.

Watch more
RADWAG videos

movie
Radwag WEBINARS