Termobilancia MA 50.X2.A

Radwag Balances and Scales - Advanced Weighing Technologies
Selected language Italiano
Termobilancia MA 50.X2.A › Pharma and Biotech Solutions
This image is for reference only.

Termobilancia MA 50.X2.A

Codice prodotto: WL-306-0021
Change the model (15)
done
Max: 50gd: 1mg

 ø90, h= 8mm
expand_more
Max: 50gd: 0,1mg

 ø90, h= 8mm
Max: 50gd: 1mg

 ø90, h= 8mm
Max: 50gd: 0,1mg

 ø90, h= 8mm
Max: 50gd: 0,1mg

 ø90, h= 8mm
Max: 50gd: 1mg

 ø90, h= 8mm
Max: 110gd: 1mg

 ø90, h= 8mm
Max: 110gd: 1mg

 ø90, h= 8mm
Max: 110gd: 1mg

 ø90, h= 8mm
Max: 200gd: 0,1mg

 ø90, h= 8mm
Max: 200gd: 0,1mg

 ø90, h= 8mm
Max: 200gd: 0,1mg

 ø90, h= 8mm
Max: 210gd: 1mg

 ø90, h= 8mm
Max: 210gd: 1mg

 ø90, h= 8mm
Max: 210gd: 1mg

 ø90, h= 8mm
Capacita massima  [Max]: 50 g
Divisione: 1 mg

close
Change the model:
Termobilancia MA 50/1.X2.A.NS
Termobilancia MA 50.X2.A.NS
Termobilancia MA 50/1.X2.A
Termobilancia MA 50.X2.A
Termobilancia MA 50/1.X2.A.WH
Termobilancia MA 50.X2.A.WH
Termobilancia MA 110.X2.A.WH
Termobilancia MA 110.X2.A.NS
Termobilancia MA 110.X2.A
Termobilancia MA 200/1.X2.A
Termobilancia MA 200/1.X2.A.WH
Termobilancia MA 200/1.X2.A.NS
Termobilancia MA 210.X2.A.WH
Termobilancia MA 210.X2.A.NS
Termobilancia MA 210.X2.A
Select all
Vista
Salva
aggiungere a confrontare
caratteristiche generali
Le termobilance serie MA X2.A sono strumenti di misura ad alta tecnologia realizzate per eseguire velocemente la determinazione del contenuto di umidita realtiva, la percentuale di secco, ed altri parametri in campioni di svariate matrici.

Le termobilance della serie MA.X2.A sono equipaggiate con un sistema innovativo che permette di aprire e chiudere la camera di essiccazione utilizzando un comando o un sensore di prossimita. Questa soluzione permette:
Mantenere la termobilancia pulita – l’operatore non deve piu interagire direttamente con lo strumento.
 
Evitare colpi dovuti ad una chiusura o aprtura della camera troppo violente – la camera si chiude automaticamente e l’apertura e controllata.
 
Acquisire una elevata ripetitivita nel nell’apertura/chiusura della camera.
 
Elevare l’automazione del processo di pesata.
 
Aumentare la sicurezza eliminando il contatto con parti a temperatura elevata della camera.
 
Migliorare l’ergonomia.
Le termobilance della serie MA X2.A sono equipaggiate con un display a colori touch screen di facile utilizzo. E’ possibile personalizzare liberamente il pannello di controllo per mezzo di comandi diretti, campi di informazione personalizzati, e etichette programmabili. Il processo di essiccazione puo essere eseguito a qualsiasi temperatura e – grazie al suo database – processi di essiccazione dedicati possono essere automaticamente assegnati a determinati prodotti.

Le termobilance serie MA.X2.A sono disponibili dal 01.01.2017!


Termobilance serie MA X2 in breve:
Apertura e chiusura automatica della camera di essiccazione
Touch screen capacitivo da 5”
interfaccia moderna
Operativita semplice ed intuitiva
Display programmabile
Profili di essicazione (standard, dolce, a passi, veloce)
Opzione di autospegnimento (automatica, a tempi definiti, manuale)
Stampa rapporti GLP/GMP
Applicazioni personalizzabili e ripetibili
Ottimizzazione dell’analisi grazie all’uso della lampada alogena.
Pesate campione utilizzabili con le termobilance serie MA X2.A: da portata 50g con divisione 0.1mg a portata 210g con divisione 1mg. Il contenuto di umidita viene analizzato con una accuratezza dello 0.01% (0.001 % per campioni di pesata superiore a 1.5g). La temperatura massima impostabile e di 160°C (opzionale fino a 250°C).
per analizzare la permeabilita al vapore acque dedicato all’industria conciaria per verificare le proprieta igieniche delle pelli.

DATABASE:

Il sistema informativo delle termobilance serie X2 e basato su 6 databases che permettono a operatori diversi di utilizzare database prodotti contenenti moltissimi campioni. I dati rilevati possono essere di utilizzati per successive analisi degli stessi.

I dati sono contenuti in 6 distinti database:
Utilizzatori (fino a 100 utilizzatori)
Prodotti (fino a 5000 prodotti)
Clienti (fino a 100 clienti)
Imballi (fino a 100 imballi)
Programmi di essiccazione (fino a 200 programmi di essiccazione)
Rapporti dei programmi di essiccazione (fino a 5000 rapporti)
L’interfaccia USB assicura un trasferimento o copia dei risultati del lavoro degli operatori molto veloce (analisi, rapporti, database) ad un PC o ad un altroa termobilancia. L’accesso remoto a queesti strumenti permette una gestione dei dati direttamente in linea. L’utilizzo in collaborazine con un sistema E2R permette la gestione esterna dei dati che implica una maggiore efficianza nel lavoro e risultati al massimo livello
Stainless Steel in RADWAG products
Learn about the use and maintenance of stainless steel products:
Stainless Steel in RADWAG products. Standard and special applications
foglio di calcolo
Capacita massima  [Max]

50

 g

Divisione

1

 mg

intervallo di tara

-50

 g

Calibrazione

external

 

Pesata massima

50

 g

Modulo riscaldante

IR emitter

 

Ripetibilita del contenuto di umidita

+/-0,05% (sample ~ 2g), +/-0,01% (sample ~ 10g)

 

Moisture content readability

0,001%

 

Intervallo di temperature di essiccazione

max 160

 °C

Leveling system

manual

 

display

5” graphic color touchscreen

 

punteggio IP

IP 43

 

Dimensioni del piatto di pesata

ø90, h= 8

 mm

Packaging dimensions

470×380×336

 mm

Peso netto

5,2

 kg

Peso lordo

6,7

 kg

interfaccia

RS232¹, USB-A, USB-B, Ethernet, Wi-Fi®

 

Alimentatore

100V – 120V AC 50/60Hz or 200V-240V AC 50/60Hz

 

Alimentazione

6 W

 

Heating module power

450 W

 

temperatura di lavoro

+10 — +40

 °C

Modo di essiccazione

4 drying profiles (standard, fast, step, mild)

 

Opzione di auto spegnimento

4 modes (automatic, manual, time-defined, user-defined)

 

Funzioni addizionali

sample traceability

 

Altezza massima campione

20

 mm

CE
Video
Measurement of Samples of High Moisture Content
funzioni
Autotest

Autotest

Diagnostic function aiming at metrological parameters determination (repeatability), the parameters are determined for the actual conditions of use. When speaking of repeatability it may be also used for weighing time optimization. Autotest is operated in an automatic mode thus operator’s time is saved.
Dosing

Dosing

Weighing process for which reference mass has been determined together with tolerance for its determination. Dosing tolerance is given in [%] and it is calculated in relation to the reference value thus being a permissible deviation of this process. This solution is used for weighing powders, liquids and loose materials. Dosing function performance is often supported with bargraph - load indicator. For industrial scales it is possible to use a control systems of dosing process.
Percent Weighing

Percent Weighing

Percent Weighing function is used for comparision of measured products with mass standard. Mass of a mass standard may be a numeric value taken from a database or it may be determined through a measurement process. Each measured product is compared to mass standard, mass of which is presumed as a model 100% ideal mass. For products weighing less than the mass standard, obtained results are lower than 100%, for products weighing more, the obtained results are greatly  exceeded.
Parts counting

Parts counting

Function using mass measurement for determination of  measured items quantity. Mass of a single item is required for this process. It may be either estimated through weighment or taken from a database. For items counting the following algorithm is used: all items mass / single item mass = quantity. Function operation is supperted by a mechanism of Automatic Correction of Accuracy. This allows to update single item mass in course of the process. To a certain extend Automatic Correction of Accuracy eliminates error which may be a result of different mass values of seemingly alike single elements. For industry solutions items counting may be simultaneously carried out with checkweighing and dosing thus industry solutions feature audio signalling base informing that specified number of items has been weighed. It is possible to apply weighing systems using few platfroms of different MAX capacities and different accuracies.
Peak hold

Peak hold

Function registering the greatest temporary indication occurring in course of the weighing process. It is most often used in medical scales in order to hold the measurement indication.
Formulation

Formulation

Function supporting the mixture making process, wherein the mixture contains various components. Formulation function usually uses the balance/scale database of components. Formulation serves for monitored checkweighing of every single component with a given tolerance. It is enriched with a set of individual settings.
Statistics

Statistics

Statistiscs function registers and analyses performed measurements. This supplies the user withthe following information: Max and Min standard deviation, average value, variance, range et.
Checkweighing

Checkweighing

Checkweighing function is used for checking whether the measured sample mass is within the predefined threshold values, Low [LO] and Hgh [HI]. The thresholds are given in [g] and [kg] units. Current state of a sample being measured is signalled by means of pictorgams located on a display for laboratory balances, for industrial scales Stackligt System is used. This visual +/- inspection is in operation during segregation, control or packing process of products for which mass has bees determined with a specifaied tolerance, eg. 12860 g 961
IR sensors

IR sensors

Programmable function supporting the weighing process through control of the following options: sliding weighing chamber doors, printout, zeroing, tarring etc. Especially appreciated wherever preventing the balance from soiling is important.
Under-pan weighing

Under-pan weighing

The solution enables weighing with use of a stand, which is advisable for loads of non-standard shapes and dimensions and those that generate magnetic field.
GLP Procedures

GLP Procedures

Diagnostic function allowing to objectively document performed measurements. GLP procedures may be either presented in a short report form or extended one.
Animal weighing

Animal weighing

Process of mass determination for a product which may unwillingly reposition within the weighing pan. Mass determination in such cases requires much longer period of time when compared to typical weighing process. It is the user who defines period of time needed for control of measured product mass. The user can thus optimize the function depending on the measured product characteristics.
Density determination

Density determination

Liquid or solid body density function uses the Archimedes principle and it requires a special kit to be applied. The kit when used, replaces a weighing pan. For solids mass of the sample must be determined first in the air, next in the liquid of specified density. For liquids the so called sinker, density of which has been determined, must be measured first in the air, next in the tested liquid. The density determination process is disturbed by air bubbles which may stick either to the measured sample or the sinker. In case of laboratory equipment very light solids may be measured. For industry, solid bodies density may be determined by means of  under-pan weighing. Tested load of significant size may be measured this way.
Ambient conditions monitoring

Ambient conditions monitoring

The possibility of cooperation with the THBR 2.0 system
Replaceable unit

Replaceable unit

Replaceable units.
Statistical Quality Control

Statistical Quality Control

Statistical control for determination of basic statistical criteria: maximum, minimum, standard deviation, mean values for each batch, etc.
ALIBI Memory

ALIBI Memory

"ALIBI" memory enables saving and storing up to 100000 measurements.  Measurements are saved automatically upon each pressing of the key. There is no need for any additional operations or changing settings.
The following data related with the measurements is saved: measurement date; measurement time; result (mass); tare value; operator carrying out the measurement (logged in); product name.
The software saves the measurement in a so called loop, i.e. when the measurement no. 100001 is saved, the measurement 1 gets automatically deleted from the memory.
Measurements saved to balance memory cannot be deleted.
You can preview and print out the data saved to the ALIBI database.
Drying modes

Drying modes

Method for obtaining maximum drying temperature. There are 4 drying profiles: standard, mild, step, fast. The profiles differ by which ensure various dynamics of temperature increase.
Samples drying

Samples drying

Drying process enables to determine moisture content of a given sample by evaporating its free water and other components. The sample's moisture content [%M] is determined by means of precise weighing carried out before and during the drying process. 
 
Moisture content analysis

Moisture content analysis

Determination of sample's moisture content.
Dry mass determination

Dry mass determination

Determination of product mass after completed technological, physical and chemical processes enforcing product moisture evaporation. RADWAG moisture analyzers are designed to test the moisture content by heating of the samples, which is done using an IR emitter, a halogen or a metal heater.
Mass for titrator

Mass for titrator

'Mass value for a titrator' working mode enables establishing connection between the weighing device and a titrator. The titrator receives information about the quantity of dispensed mass, and the weighing instrument receives a signal to start subsequent weighing.
Wi-Fi®

Wi-Fi®

Wi-Fi® offers possibility to send data from balance to a mobile iOS or Android device, via special data management apps. Wireless communication between the indicator and the weighing instrument enables operating the balance that is placed inside a laminar flow hood or a fume cupboard.
documentazione
Data Sheet Data Sheet
Data Sheet

Vista
Vista
Salva
Salva

Choose more product:
Vista Vista SalvaSalva
Start up Guide
Start up Guide
Vista
Vista
Salva
Salva
(1.29 MB)
21 CFR Part 11 Compliance Module
21 CFR Part 11 Compliance Module
Vista
Vista
Salva
Salva
(1.75 MB)
User Manual - MA.X2 moisture analyzers
User Manual - MA.X2 moisture analyzers
Vista
Vista
Salva
Salva
(3.05 MB)
Conformity Declaration
Conformity Declaration
Vista
Vista
Salva
Salva
(0.04 MB)
Practical aspects of moisture analysis
Practical aspects of moisture analysis
Vista
Vista
Salva
Salva
(0.54 MB)
Water vapour permeability though
Water vapour permeability though
Vista
Vista
Salva
Salva
(0.20 MB)
Determination of food products’ water content performed using MA.X2 and PMV moisture analyzers
Determination of food products’ water content performed using MA.X2 and PMV moisture analyzers
Vista
Vista
Salva
Salva
(1.54 MB)
Moisture Analyzers MA X2.A
Moisture Analyzers MA X2.A
Vista
Vista
Salva
Salva
(1.45 MB)
USB Free Link - Direct Balance-PC Communication
USB Free Link - Direct Balance-PC Communication
Vista
Vista
Salva
Salva
(2.07 MB)
Thermogravimetric Testing of the Water Content in Plastic Granules
Thermogravimetric Testing of the Water Content in Plastic Granules
Vista
Vista
Salva
Salva
(2.27 MB)
Determination of dry mass of wastewater sludge
Determination of dry mass of wastewater sludge
Vista
Vista
Salva
Salva
(20.70 MB)
Stainless Steel in RADWAG products. Standard and special applications
Stainless Steel in RADWAG products. Standard and special applications
Vista
Vista
Salva
Salva
(2.44 MB)
X2 Series Balances
X2 Series Balances
Vista
Vista
Salva
Salva
(4.89 MB)
Defined Weighing Profiles
Defined Weighing Profiles
Vista
Vista
Salva
Salva
(1.36 MB)
Accuracy and Precision of Water Content Determination
Accuracy and Precision of Water Content Determination
Vista
Vista
Salva
Salva
(0.82 MB)
Moisture Analyzers
Moisture Analyzers
Vista
Vista
Salva
Salva
(8.28 MB)
Moisture analysres and moisture content measurement
Moisture analysres and moisture content measurement
Vista
Vista
Salva
Salva
(4.46 MB)
White papers
Artificial fertilizers
Artificial fertilizers
Vista
Vista
Salva
Salva
(0.34 MB)
Avocado
Avocado
Vista
Vista
Salva
Salva
(0.36 MB)
Bath gel, shower gel
Bath gel, shower gel
Vista
Vista
Salva
Salva
(0.34 MB)
Black olive
Black olive
Vista
Vista
Salva
Salva
(0.33 MB)
Black pepper
Black pepper
Vista
Vista
Salva
Salva
(0.34 MB)
Bran
Bran
Vista
Vista
Salva
Salva
(0.34 MB)
Butter
Butter
Vista
Vista
Salva
Salva
(0.34 MB)
Calcium silicate
Calcium silicate
Vista
Vista
Salva
Salva
(0.34 MB)
Candied cherries
Candied cherries
Vista
Vista
Salva
Salva
(0.33 MB)
Candle wicks
Candle wicks
Vista
Vista
Salva
Salva
(0.34 MB)
Caseinate
Caseinate
Vista
Vista
Salva
Salva
(0.34 MB)
Cheese spread
Cheese spread
Vista
Vista
Salva
Salva
(0.33 MB)
Cheesy spinach sauce
Cheesy spinach sauce
Vista
Vista
Salva
Salva
(0.33 MB)
Chocolate
Chocolate
Vista
Vista
Salva
Salva
(0.34 MB)
Cocoa
Cocoa
Vista
Vista
Salva
Salva
(0.34 MB)
Coffee
Coffee
Vista
Vista
Salva
Salva
(0.34 MB)
Cranberry
Cranberry
Vista
Vista
Salva
Salva
(0.33 MB)
Crisps
Crisps
Vista
Vista
Salva
Salva
(0.33 MB)
Dog food
Dog food
Vista
Vista
Salva
Salva
(0.39 MB)
Dried carrot
Dried carrot
Vista
Vista
Salva
Salva
(0.33 MB)
Dried potato
Dried potato
Vista
Vista
Salva
Salva
(0.33 MB)
Expanded wafers
Expanded wafers
Vista
Vista
Salva
Salva
(0.34 MB)
Fish food
Fish food
Vista
Vista
Salva
Salva
(0.38 MB)
Flour
Flour
Vista
Vista
Salva
Salva
(0.33 MB)
Forcemeat stuffing
Forcemeat stuffing
Vista
Vista
Salva
Salva
(0.34 MB)
Freeze dried fruits
Freeze dried fruits
Vista
Vista
Salva
Salva
(0.35 MB)
Freeze dried fruits
Freeze dried fruits
Vista
Vista
Salva
Salva
(0.35 MB)
Fried cheese
Fried cheese
Vista
Vista
Salva
Salva
(0.34 MB)
Garlic sauce
Garlic sauce
Vista
Vista
Salva
Salva
(0.33 MB)
Grains barley
Grains barley
Vista
Vista
Salva
Salva
(0.37 MB)
Grains horse bean
Grains horse bean
Vista
Vista
Salva
Salva
(0.36 MB)
Grains maize
Grains maize
Vista
Vista
Salva
Salva
(0.36 MB)
Ketchup
Ketchup
Vista
Vista
Salva
Salva
(0.33 MB)
Lactose
Lactose
Vista
Vista
Salva
Salva
(0.33 MB)
Mayonnaise
Mayonnaise
Vista
Vista
Salva
Salva
(0.33 MB)
Millet groats
Millet groats
Vista
Vista
Salva
Salva
(0.33 MB)
Nuts and almonds
Nuts and almonds
Vista
Vista
Salva
Salva
(0.34 MB)
Paper
Paper
Vista
Vista
Salva
Salva
(0.34 MB)
Pita
Pita
Vista
Vista
Salva
Salva
(0.33 MB)
Plastic granules
Plastic granules
Vista
Vista
Salva
Salva
(0.36 MB)
Plasticizers for concrete
Plasticizers for concrete
Vista
Vista
Salva
Salva
(0.34 MB)
Potato and corn pellete
Potato and corn pellete
Vista
Vista
Salva
Salva
(0.33 MB)
Potato starch
Potato starch
Vista
Vista
Salva
Salva
(0.33 MB)
Powder paint
Powder paint
Vista
Vista
Salva
Salva
(0.35 MB)
Raisins
Raisins
Vista
Vista
Salva
Salva
(0.33 MB)
Salted smoked freeze dried cheese
Salted smoked freeze dried cheese
Vista
Vista
Salva
Salva
(0.34 MB)
Sludge
Sludge
Vista
Vista
Salva
Salva
(0.34 MB)
Unwoven fabric
Unwoven fabric
Vista
Vista
Salva
Salva
(0.34 MB)
Wc gel, washing gel, liquid soap
Wc gel, washing gel, liquid soap
Vista
Vista
Salva
Salva
(0.34 MB)
White rice
White rice
Vista
Vista
Salva
Salva
(0.33 MB)
software
Drivers

RADWAG USB DRIVER 1.6.2 (1.25 MB)

Radwag bilance e sistemi di pesatura
Torunska 5
26-600 Radom
Poland
tel.: +48 48 386 60 00
e-mail: export@radwag.com
TIN: PL7960000327
Vimeo Radwag YouTube Radwag Facebook Radwag LinkedIn Radwag
© 2023 Radwag bilance e sistemi di pesatura. Diritti riservati

selezionare

×
Change language AlbanianAlbanian
Change language DanishDanish
Change language NederlandseNederlandse
Change language EstonianEstonian
Change language FinnishFinnish
Change language HungarianHungarian
Change language IcelandicIcelandic
Change language KazakhKazakh
Change language LatvianLatvian
Change language LithuanianLithuanian
Change language MacedonianMacedonian
Change language NorwegianNorwegian
Change language PortuguesePortuguese
Change language RomanianRomanian
Change language RussianRussian
Change language SlovakSlovak
Change language SlovenianSlovenian
Change language SwedishSwedish
Change language UkrainianUkrainian
Change language SerbianSerbian
Change language MontenegrinMontenegrin
Change language page on Deutsch Deutsch
Change language page on English English
Change language page on Español Español
Change language page on Français Français
Change language page on Polski Polski
Change language page on Türkiye Türkiye
Česky
Change website to USA USA
Change language page on 中文 中文
SubscribeSubscribe
Radwag in FacebookFacebook
Radwag in YouTubeRadwag in YouTubeYoutube
Radwag in VimeoVimeo
Radwag in LinkedInLinkedIn
Webinars RadwagWebinars
close
E-mail
nome azienda:
Nome:
I consent to the processing of my personal data for marketing purposes by Radwag Wagi Elektroniczne Witold Lewandowski.
I consent to receive marketing and product-related messages by electronic means from Radwag Wagi Elektroniczne Witold Lewandowski.
I have read the Privacy Policy of RADWAG Wagi Elektroniczne Witold Lewandowski.
lock_openI want to access the files
close
Slide to go back ↩