Balance de précision 5Y.120.PM

Radwag Les Balances Electroniques
Selected language Français
Obraz
This image is for reference only.

Balance de précision 5Y.120.PM

Code produit: WL-224-0009
Change the model (8)
done
Max: 120kgd: 0,2g

 400×500mm
expand_more
Max: 10kgd: 0,01g

 200×185mm
Max: 15kgd: 0,01g

 200×185mm
Max: 20kgd: 0,01g

 200×185mm
Max: 25kgd: 0,1g

 350×260mm
Max: 35kgd: 0,1g

 350×260mm
Max: 50kgd: 0,1g

 350×260mm
Max: 60kgd: 0,1g

 400×500mm
Capacité maximale [Max]: 120 kg
Précision de lecture: 0,2 g

close
Change the model:
Balance de précision 5Y.10.PM
Balance de précision 5Y.15.PM
Balance de précision 5Y.20.PM
Balance de précision 5Y.25.PM
Balance de précision 5Y.35.PM
Balance de précision 5Y.50.PM
Balance de précision 5Y.60.PM
Balance de précision 5Y.120.PM
Select all
Voir
Download
Pour Comparer Recherche avancée
Description
 

Balances RADWAG PM

 
Précision de laboratoire dans des conditions industrielles.
 
 

Technologie améliorée

  • Possibilité de peser des charges jusqu’à 120 kg sur un grand plateau avec une grande précision et une bonne répétabilité
  • erreur d’excentricité minimale dans toute la gamme,
  • mesure rapide et stable (réalisable en 1 seconde),
  • stabilité des paramètres dans le temps et dans le transport,
  • dimensions du plateau de pesée ajustées à la précision de la balance
sont les caractéristiques des balances RADWAG PM. Tout cela est le résultat de l’application d’un système de mesure innovant basé sur la technologie améliorée 

MONO

BLOCK®
 
Le changement de la structure monobloc a permis de travailler avec une précision de 0,01 g avec une capacité de charge de 20 kg et 0,2 g avec une capacité de charge de 120 kg, une répétabilité à partir de 0,01 g et une résistance aux changements de conditions environnementales.
 
 
 

Les balances PM comprennent également :

 
  • construction solide basée sur un monobloc plus grand et plus haut,
  • système intégré de protection contre les surcharges à 4 points,
  • étalonnage interne,
  • écran tactile 10 pouces,
  • mise en service facile, utilisation intuitive et ergonomie de travail,
  • la conformité au 21 CFR Part 11,
  • audit numérique de pesée DWA (Digital Weighing Auditor),
 

  • méthode de vérification de l’utilisateur en plusieurs étapes,
  • Alertes lumineuses d’ambiance Ambient Light,
  • Hotspot,
  • RFID*,
  • Texte Live Note et notes vocales,
  • commandes vocales données aux balances,
  • historique de référence des mesures dans la Handy Library,
  • widgets,
  • degré de protection IP 54.
 
 
 

Le Modbus TCP/IP

est un de protocoles plus populaires dans le domaine des systèmes de communication industrielle automatisée. Incorporé aux balances 5Y et CY10, en raison de sa capacité à mettre en réseau divers dispositifs, le protocole facilite le travail à des intégrateurs.
 
Le protocole Modbus échange des informations en utilisant un mécanisme de requête-réponse entre un automate programmable industriel API (PLC) qui est un maître et la balances qui est un esclave. Dans les balances 5Y et C10, le protocole Modbus TCP/IP permet, entre autres, les fonctions de lecture de masse, zérotage et tarage de la balance, ainsi que de configuration de la tare et des seuils MIN et MAX.

 
 
 
 

21 CFR Part 11

Vous travaillez dans l’industrie pharmaceutique ? Avez-vous besoin d’une signature numérique ?
 
Nous proposons une balance de laboratoire qui, en tant que dispositif autonome, répond aux exigences de 21 CFR Partie 11/ EU BPL Annex 11.
 
- Sécurité totale des données
- Signatures électroniques
- Validations
- Dossiers électroniques
- Pistes d’audit
 
 

Application

Les balances PM garantissent non seulement une lecture précise et une mesure rapide, mais sont également universelles et peuvent donc être utilisées dans de nombreux secteurs industriels.
 
Le dosage, la formulation et le comptage de pièces ne sont que quelques-unes des applications possibles de ces dispositifs polyvalents.
 
Les balances PM trouveront des destinataires partout où des disositifs de pesage avec une grande précision et une grande capacité de charge sont nécessaires.
* RFID ISO/IEC 14443 Type A, 13,56 MHz
 
 
 
Paramètres Techniques
Capacité maximale [Max]

120

 kg

Capacité minimale [Min]

-

 

Précision de lecture

0,2

 g

Échelon de légalisation [e]

-

 

Étendue de tare

-120

 kg

Pesée minimale USP

164

 g

Pesée minimale (U=1%, k=2)

16,4

 g

Répétabilité (Max)

0,2

 g

Répétabilité (5% Max)

0,082

 g

Linéarité

±0,6

 g

Temps de stabilisation

1

 s

Ajustage

interne (automatique)

 

Classe de précision OIML

-

 

Système de nivellement

semi-automatique – LevelSENSING

 

Afficheur

10″ graphique couleurs écran tactile

 

Dimension du plateau

400×500

 mm

Dimensions de colis

710×610×240

 mm

Masse nette

22

 kg

Masse brute

24,5

 kg

Degré de protection

IP 43

 

Interface de Communication

2×USB-A, USB-C, HDMI, Ethernet, Wi-Fi®, Hotspot

 

Alimentation

Adapter: 100 – 240V AC 50/60Hz 1A; 15V DC 2,4A
Balance: 12 – 15V DC 1,6A max; 10–19W*

 

Température du travail

+10 – +40

 °C

CE

Répétabilité exprimée comme un écart standardisé de 10 placements de chargé.
Temps de stabilisation dépend de conditions externes et de la dynamique du placement d’un poids sur le plateau; déterminé pour le profil FAST.
*La consommation électrique dépend de la configuration du terminal ainsi que du nombre et du type de périphériques connectés.

360°
Films
5Y Functions: Animal Weighing
5Y Functions: Statistics
5Y Functions: DWA®
5Y Balance and Barcode Scanner – Easy Connection
5Y Functions: Checkweighing
5Y Functions: Dosing
5Y Functions: Formulations
Percentage deviations
5Y Functions: Weighing
5Y Functions: Parts counting
5Y Functions: Proximity Sensors – Touch-Free Control (Tutorial)
5Y Functions: GLP Procedures – Objective Documentation of Measurements (Tutorial)
Weighing Printout Design in Analytical and Precision Balances (Tutorial)
Impression facile avec Wi-Fi® Thermal Receipt Printer – imprimante de reçus thermique de Radwag
ELLIPSIS – une nouvelle balance de RADWAG
ELLIPSIS – Innovation technologique
Dis-le! Commandes vocales dans la nouvelle balance ELLIPSIS de RADWAG
ELLIPSIS – Scannez ou passez la carte devant le lecteur
Connexion VPN à la balance ELLIPSIS
ELLIPSIS – Connexions illimitées
Connexion de la balance série 5Y a l’imprimante RTP-UEW80 via Wi-Fi®®
Balances PM 5Y – précision de laboratoire dans des conditions industrielles
NOUVEAUTE : Première imprimante de reçus de production RADWAG!
Solution complète pour la mesure de la masse en pharma
New AS and PS 5Y Balances – Autotest (Tutorial)
Fonctions
Autotest

Autotest

Diagnostic function aiming at metrological parameters determination (repeatability), the parameters are determined for the actual conditions of use. When speaking of repeatability it may be also used for weighing time optimization. Autotest is operated in an automatic mode thus operator’s time is saved.
Dosing

Dosing

Weighing process for which reference mass has been determined together with tolerance for its determination. Dosing tolerance is given in [%] and it is calculated in relation to the reference value thus being a permissible deviation of this process. This solution is used for weighing powders, liquids and loose materials. Dosing function performance is often supported with bargraph - load indicator. For industrial scales it is possible to use a control systems of dosing process.
Percent Weighing

Percent Weighing

Percent Weighing function is used for comparision of measured products with mass standard. Mass of a mass standard may be a numeric value taken from a database or it may be determined through a measurement process. Each measured product is compared to mass standard, mass of which is presumed as a model 100% ideal mass. For products weighing less than the mass standard, obtained results are lower than 100%, for products weighing more, the obtained results are greatly  exceeded.
Parts counting

Parts counting

Function using mass measurement for determination of  measured items quantity. Mass of a single item is required for this process. It may be either estimated through weighment or taken from a database. For items counting the following algorithm is used: all items mass / single item mass = quantity. Function operation is supperted by a mechanism of Automatic Correction of Accuracy. This allows to update single item mass in course of the process. To a certain extend Automatic Correction of Accuracy eliminates error which may be a result of different mass values of seemingly alike single elements. For industry solutions items counting may be simultaneously carried out with checkweighing and dosing thus industry solutions feature audio signalling base informing that specified number of items has been weighed. It is possible to apply weighing systems using few platfroms of different MAX capacities and different accuracies.
Peak hold

Peak hold

Function registering the greatest temporary indication occurring in course of the weighing process. It is most often used in medical scales in order to hold the measurement indication.
Formulation

Formulation

Function supporting the mixture making process, wherein the mixture contains various components. Formulation function usually uses the balance/scale database of components. Formulation serves for monitored checkweighing of every single component with a given tolerance. It is enriched with a set of individual settings.
Statistics

Statistics

Statistiscs function registers and analyses performed measurements. This supplies the user withthe following information: Max and Min standard deviation, average value, variance, range et.
Checkweighing

Checkweighing

Checkweighing function is used for checking whether the measured sample mass is within the predefined threshold values, Low [LO] and Hgh [HI]. The thresholds are given in [g] and [kg] units. Current state of a sample being measured is signalled by means of pictorgams located on a display for laboratory balances, for industrial scales Stackligt System is used. This visual +/- inspection is in operation during segregation, control or packing process of products for which mass has bees determined with a specifaied tolerance, eg. 12860 g 961
IR sensors

IR sensors

Programmable function supporting the weighing process through control of the following options: sliding weighing chamber doors, printout, zeroing, tarring etc. Especially appreciated wherever preventing the balance from soiling is important.
GLP Procedures

GLP Procedures

Diagnostic function allowing to objectively document performed measurements. GLP procedures may be either presented in a short report form or extended one.
Animal weighing

Animal weighing

Process of mass determination for a product which may unwillingly reposition within the weighing pan. Mass determination in such cases requires much longer period of time when compared to typical weighing process. It is the user who defines period of time needed for control of measured product mass. The user can thus optimize the function depending on the measured product characteristics.
Pipettes Calibration

Pipettes Calibration

Function verifying correctness of piston pipettes functioning, the verification is performed via gravimetric measurement of the excreted liquid. Pipettes calibration may be either a stand-alone module or it may be operated
Air density correction

Air density correction

Function performing correction of mass measurement indication, wherein the air density is taken into account. It is used in balances with reading unit < 0,01 mg.
Density determination

Density determination

Liquid or solid body density function uses the Archimedes principle and it requires a special kit to be applied. The kit when used, replaces a weighing pan. For solids mass of the sample must be determined first in the air, next in the liquid of specified density. For liquids the so called sinker, density of which has been determined, must be measured first in the air, next in the tested liquid. The density determination process is disturbed by air bubbles which may stick either to the measured sample or the sinker. In case of laboratory equipment very light solids may be measured. For industry, solid bodies density may be determined by means of  under-pan weighing. Tested load of significant size may be measured this way.
Differential weighing

Differential weighing

Differential weighing informs about mass variation a particular sample, wherein the said variation is a result of manufacturing processes.

Differential weighing is often applied in product control process, for which reference product parameters have been specified in order to be used as a source of comparison for the whole series.
Insuchcasestandard deviation is the information which tells about quality and completeness of a final product. For systems based on a feed-back technique such information may be used by control units.
Ambient conditions monitoring

Ambient conditions monitoring

The possibility of cooperation with the THBR 2.0 system
Statistical Quality Control

Statistical Quality Control

Statistical control for determination of basic statistical criteria: maximum, minimum, standard deviation, mean values for each batch, etc.
Packaged Goods Control

Packaged Goods Control

Pre-packaged Goods Control mode enables to collect weighings from RADWAG-designed weighing instruments, carry out control and generate PGC reports. Different types of weighing instruments can be combined into a network. The control can be started on a balance or via computer software. It is automatically finished after a respective quantity of packages is verified.
Collected data allows you to assess quality of produced pre-packaged goods and their conformity with:
- internal quality control system;
- 'Pre-Packaged Goods' regulation of 7th May 2009 (Journal of Laws No 91, item 740), on the requirements concerning quantity inspection of pre-packaged goods control, which inspection is to be carried out by means of random selection of the measurements results and sending those results to pre-packaged goods control procedure.
ALIBI Memory

ALIBI Memory

"ALIBI" memory enables saving and storing up to 100000 measurements.  Measurements are saved automatically upon each pressing of the key. There is no need for any additional operations or changing settings.
The following data related with the measurements is saved: measurement date; measurement time; result (mass); tare value; operator carrying out the measurement (logged in); product name.
The software saves the measurement in a so called loop, i.e. when the measurement no. 100001 is saved, the measurement 1 gets automatically deleted from the memory.
Measurements saved to balance memory cannot be deleted.
You can preview and print out the data saved to the ALIBI database.
Wi-Fi®

Wi-Fi®

Thanks to wireless communication between the computer and a balance, it is possible to use a balance inside a laminar flow hood and a fume cupboard.

Documentation
Cartes de produits
Data Sheet Data Sheet
Data Sheet

Voir
Voir
Download
Download

Choose more product:
Voir Voir DownloadDownload
Modes d'emploi
User Manual
User Manual
Voir
Voir
Download
Download
(2.36 MB)
User Manual
User Manual
Voir
Voir
Download
Download
(1.24 MB)
Software Manual
Software Manual
Voir
Voir
Download
Download
(1.23 MB)
User Manual
User Manual
Voir
Voir
Download
Download
(13.23 MB)
Software Manual
Software Manual
Voir
Voir
Download
Download
(0.95 MB)
Start Up Guide
Start Up Guide
Voir
Voir
Download
Download
(5.55 MB)
Déclarations de conformité
Conformity Declaration
Conformity Declaration
Voir
Voir
Download
Download
(0.04 MB)
Publications et brochures
Laboratory balance cleaning
Laboratory balance cleaning
Voir
Voir
Download
Download
(2.52 MB)
RTP Thermal Receipt Printer
RTP Thermal Receipt Printer
Voir
Voir
Download
Download
(1.64 MB)
PM Precision Balances
PM Precision Balances
Voir
Voir
Download
Download
(5.47 MB)
RFID
RFID
Voir
Voir
Download
Download
(0.68 MB)
Hybrid Protective Glass
Hybrid Protective Glass
Voir
Voir
Download
Download
(1.86 MB)
Micro Scale Measurement
Micro Scale Measurement
Voir
Voir
Download
Download
(2.74 MB)
Laboratory Balances
Laboratory Balances
Voir
Voir
Download
Download
(1.68 MB)
Metrology in the laboratory 2024
Metrology in the laboratory 2024
Voir
Voir
Download
Download
(5.65 MB)
ELLIPSIS Balances de laboratoire série 5Y
ELLIPSIS Balances de laboratoire série 5Y
Voir
Voir
Download
Download
(29.83 MB)
Accessoires
Modules additionnels

RES Protocole de communication Radwag3
Module de conformité à 21 CFR partie 113

Newsletter

Inscrivez-vous à la Newsletter de RADWAG pour tout savoir sur nos nouveautés.

Voir plus
Radwag Balances Électroniques
Torunska 5
26-600 Radom
Poland
tel.: +48 48 386 60 00
e-mail: export@radwag.com
TIN: PL7960000327
Vimeo Radwag YouTube Radwag Facebook Radwag LinkedIn Radwag
© 2024 RADWAG Balances Électroniques. Tous les droits sont réservés.

Wybierz język

×
Change language AlbanianAlbanian
Change language DanishDanish
Change language NederlandseNederlandse
Change language EstonianEstonian
Change language FinnishFinnish
Change language HungarianHungarian
Change language IcelandicIcelandic
Change language KazakhKazakh
Change language LatvianLatvian
Change language LithuanianLithuanian
Change language MacedonianMacedonian
Change language NorwegianNorwegian
Change language PortuguesePortuguese
Change language RomanianRomanian
Change language RussianRussian
Change language SlovakSlovak
Change language SlovenianSlovenian
Change language SwedishSwedish
Change language UkrainianUkrainian
Change language SerbianSerbian
Change language MontenegrinMontenegrin
Change language page on Deutsch Deutsch
Change language page on English English
Change language page on Español Español
Change language page on Italiano Italiano
Change language page on Polski Polski
Change language page on Türkiye Türkiye
Česky
Português (Brasil)
Change website to USA USA
Change language page on 中文 中文
Presentations Presentations Presentations
Subscribe Subscribe Subscribe
Radwag in Facebook Radwag in Facebook Facebook
Radwag in YouTube Radwag in YouTube Youtube
Radwag in Vimeo Radwag in Vimeo Vimeo
Radwag in LinkedIn Radwag in LinkedIn LinkedIn
Webinars Radwag Webinars Radwag Webinars
close
E-mail:
Nom de l’entreprise :
Prénom:
I consent to the processing of my personal data for marketing purposes by Radwag Wagi Elektroniczne Witold Lewandowski.
I consent to receive marketing and product-related messages by electronic means from Radwag Wagi Elektroniczne Witold Lewandowski.
I have read the Privacy Policy of RADWAG Wagi Elektroniczne Witold Lewandowski.
lock_openI want to access the files
close
Slide to go back ↩