Balance de précision PS 4500.X2.M.CPP

Radwag Les Balances Electroniques
Selected language Français
Balance de précision PS 4500.X2.M.CPP
This image is for reference only.

Balance de précision PS 4500.X2.M.CPP

Code produit: WK-306-0007
Change the model (5)
done
Max: 4500gd: 0,1g

 195×195mm
expand_more
Max: 750gd: 0,01g

 128×128mm
Max: 2100gd: 0,1g

 195×195mm
Max: 6100gd: 0,1g

 195×195mm
Max: 8100gd: 0,1g

 195×195mm
Capacité maximale [Max]: 4500 g
Précision de lecture: 0,1 g

close
Change the model:
Balance de précision PS 750.X2.CPP
Balance de précision PS 2100.X2.M.CPP
Balance de précision PS 4500.X2.M.CPP
Balance de précision PS 6100.X2.M.CPP
Balance de précision PS 8100.X2.M.CPP
Select all
Voir
Download
Pour Comparer Recherche avancée
Description
 

Balance de précision pour contrôle statistique

 
Cette balance est destinée au contrôle métrologique des péemballés donc elle doit être homologuée en Métrologie Légale.
Par conséquent, nous vous recommandons de choisir les balances avec une homologation respective.
 
 
La série des balances de précision avancées à hautes capacités est basée sur la technologie

MONO

BLOCK
. La construction innovante des balances PS X2.M se caractérise par la nouvelle façon à un point de fixation du plateau, ce qui garantit la très bonne géométrie de la balance et minimise l’erreur de l’excentricité. La construction à labyrinthe donne la haute résistance aux contaminations.

L’utilisation de la technologie

MONO

BLOCK
permet le pesage des charges avec la précision d=0,01g avec la capacité même jusqu’à 10 kg. La base rigide assure la stabilité du système de pesage et la résistance élevée aux impacts. Le système d’ajustage interne garantit la précision et la haute répétabilité des mesures. Le levier de la masse du poids interne rend possible l’ajustage dans toute l’étendue de mesure.
 

Les caractéristiques principales de la série PS X2.M :
  • la précision au niveau d=0,01g avec la capacité jusqu’à 10 kg
  • la haute résistance aux facteurs externes
  • la garantie de la stabilité et de la répétabilité dans le temps
  • l’application de la technologie

    MONO

    BLOCK
  • l’ajustage interne dans toute l’étendue de mesure
  • les bases de données étendues et la mémoire ALIBI
  • l’afficheur 5” tactile, en couleurs et ergonomique
  • la possibilité du service sans contact
 

Bases de données
L’appareil rend possible l’enregistrement des données concernant les pesages qui ont été réalisés sous forme des rapports et des diagrammes avancés.
Le système des informations est basé sur 7 bases de données:
  • Utilisateurs (jusqu’à 100 utilisateurs),
  • Produits (jusqu’à 5 000 produits),
  • Pesages (jusqu’à 50 000 pesages),
  • Emballages (jusqu’à 100 emballages),
  • Recettes (jusqu’à 100 recettes),
  • Clients (jusqu’à 1000 clients), 
Il est également possible de réaliser les rapports de recettes (jusqu’à 500 rapports).
 

La mémoire ALIBI offre la garantie de la sécurité et permet l’enregistrement automatique des mesures – jusqu’à 500 000 enregistrements des pesages. ALIBI rend possible l’aperçu, le copiage et l’archivage de données.

 
La communication
La série PS X2.M est équipée des interfaces de communication : 2 × RS 232, USB du type A et B, Ethernet et Wireless Connection. USB rend possible la transmission rapide et le copiage des résultats du travail (les mesures, les rapports, les bases de données) à un ordinateur ou à une autre balance. Il est possible de gérer à distance les données dans la balance.

 
Acier inoxydable in RADWAG products
Learn about the use and maintenance of stainless steel products:
Acier inoxydable dans les balances RADWAG
Paramètres Techniques
Capacité maximale [Max]

4500

 g

Capacité minimale [Min]

5

 g

Précision de lecture

0,1

 g

Échelon de légalisation [e]

0,1

 g

Étendue de tare

-4500

 g

Pesée minimale USP

10

 g

Pesée minimale (U=1%, k=2)

1

 g

Répétabilité (Max)

0,008

 g

Répétabilité (5% Max)

0,005

 g

Linéarité

±0,02

 g

Temps de stabilisation

1,5

 s

Ajustage

interne (automatique)

 

Classe de précision OIML

II

 

Système de nivellement

manuel

 

Afficheur

5” tactile couleur graphique

 

Élément du kit

Balance, plateau, couvercle de plateau, adaptateur secteur

 

Dimension du plateau

195×195

 mm

Dimensions d'appareil

333x206x107

 mm

Dimensions de colis

470×380×336

 mm

Masse nette

4,5

 kg

Masse brute

6,1

 kg

Degré de protection

IP 43

 

Bases de données

7

 

Desservice sans touche

2 senseurs infrarouge

 

Interface de Communication

2×RS232, USB-A, USB-B, Ethernet, Wi-Fi®

 

Alimentation

Adapter: 100 – 240V AC 50/60Hz 0,6A; 12V DC 1,2A
Balance: 12 – 15V DC 0,8A max

 

Prise d'alimentation par l'appareil

4 W

 

Température du travail

+10 – +40

 °C

Température de stockage

-20 – +50

 °C

Humidité relative d'air

40% – 80%

 

CE
Légalisation Extra payment
for verification
Répétabilité exprimée comme un écart standardisé de 10 placements de chargé.
Temps de stabilisation dépend de conditions externes et de la dynamique du placement d’un poids sur le plateau; déterminé pour le profil FAST
Films
Déballage et mise en service des balances série PS X2 et PS R2
Solution complète pour la mesure de la masse en pharma
Fonctions
Autotest

Autotest

Diagnostic function aiming at metrological parameters determination (repeatability), the parameters are determined for the actual conditions of use. When speaking of repeatability it may be also used for weighing time optimization. Autotest is operated in an automatic mode thus operator’s time is saved.
Dosing

Dosing

Weighing process for which reference mass has been determined together with tolerance for its determination. Dosing tolerance is given in [%] and it is calculated in relation to the reference value thus being a permissible deviation of this process. This solution is used for weighing powders, liquids and loose materials. Dosing function performance is often supported with bargraph - load indicator. For industrial scales it is possible to use a control systems of dosing process.
Plus/Minus Control

Plus/Minus Control

Control of sample's mass carried out with reference to specified MIN and MAX thresholds. The weight is considered to be correct if it is comprised within threshold values. A graphic visualisation of weighing result is displayed in a form of a bar graph.
Percent Weighing

Percent Weighing

Percent Weighing function is used for comparision of measured products with mass standard. Mass of a mass standard may be a numeric value taken from a database or it may be determined through a measurement process. Each measured product is compared to mass standard, mass of which is presumed as a model 100% ideal mass. For products weighing less than the mass standard, obtained results are lower than 100%, for products weighing more, the obtained results are greatly  exceeded.
Parts counting

Parts counting

Function using mass measurement for determination of  measured items quantity. Mass of a single item is required for this process. It may be either estimated through weighment or taken from a database. For items counting the following algorithm is used: all items mass / single item mass = quantity. Function operation is supperted by a mechanism of Automatic Correction of Accuracy. This allows to update single item mass in course of the process. To a certain extend Automatic Correction of Accuracy eliminates error which may be a result of different mass values of seemingly alike single elements. For industry solutions items counting may be simultaneously carried out with checkweighing and dosing thus industry solutions feature audio signalling base informing that specified number of items has been weighed. It is possible to apply weighing systems using few platfroms of different MAX capacities and different accuracies.
Peak hold

Peak hold

Function registering the greatest temporary indication occurring in course of the weighing process. It is most often used in medical scales in order to hold the measurement indication.
Formulation

Formulation

Function supporting the mixture making process, wherein the mixture contains various components. Formulation function usually uses the balance/scale database of components. Formulation serves for monitored checkweighing of every single component with a given tolerance. It is enriched with a set of individual settings.
Statistics

Statistics

Statistiscs function registers and analyses performed measurements. This supplies the user withthe following information: Max and Min standard deviation, average value, variance, range et.
Checkweighing

Checkweighing

Checkweighing function is used for checking whether the measured sample mass is within the predefined threshold values, Low [LO] and Hgh [HI]. The thresholds are given in [g] and [kg] units. Current state of a sample being measured is signalled by means of pictorgams located on a display for laboratory balances, for industrial scales Stackligt System is used. This visual +/- inspection is in operation during segregation, control or packing process of products for which mass has bees determined with a specifaied tolerance, eg. 12860 g 961
IR sensors

IR sensors

Programmable function supporting the weighing process through control of the following options: sliding weighing chamber doors, printout, zeroing, tarring etc. Especially appreciated wherever preventing the balance from soiling is important.
GLP Procedures

GLP Procedures

Diagnostic function allowing to objectively document performed measurements. GLP procedures may be either presented in a short report form or extended one.
Animal weighing

Animal weighing

Process of mass determination for a product which may unwillingly reposition within the weighing pan. Mass determination in such cases requires much longer period of time when compared to typical weighing process. It is the user who defines period of time needed for control of measured product mass. The user can thus optimize the function depending on the measured product characteristics.
Density determination

Density determination

Liquid or solid body density function uses the Archimedes principle and it requires a special kit to be applied. The kit when used, replaces a weighing pan. For solids mass of the sample must be determined first in the air, next in the liquid of specified density. For liquids the so called sinker, density of which has been determined, must be measured first in the air, next in the tested liquid. The density determination process is disturbed by air bubbles which may stick either to the measured sample or the sinker. In case of laboratory equipment very light solids may be measured. For industry, solid bodies density may be determined by means of  under-pan weighing. Tested load of significant size may be measured this way.
Ambient conditions monitoring

Ambient conditions monitoring

The possibility of cooperation with the THBR 2.0 system
Replaceable unit

Replaceable unit

Replaceable units.
Statistical Quality Control

Statistical Quality Control

Statistical control for determination of basic statistical criteria: maximum, minimum, standard deviation, mean values for each batch, etc.
Packaged Goods Control

Packaged Goods Control

Pre-packaged Goods Control mode enables to collect weighings from RADWAG-designed weighing instruments, carry out control and generate PGC reports. Different types of weighing instruments can be combined into a network. The control can be started on a balance or via computer software. It is automatically finished after a respective quantity of packages is verified.
Collected data allows you to assess quality of produced pre-packaged goods and their conformity with:
- internal quality control system;
- 'Pre-Packaged Goods' regulation of 7th May 2009 (Journal of Laws No 91, item 740), on the requirements concerning quantity inspection of pre-packaged goods control, which inspection is to be carried out by means of random selection of the measurements results and sending those results to pre-packaged goods control procedure.
ALIBI Memory

ALIBI Memory

"ALIBI" memory enables saving and storing up to 100000 measurements.  Measurements are saved automatically upon each pressing of the key. There is no need for any additional operations or changing settings.
The following data related with the measurements is saved: measurement date; measurement time; result (mass); tare value; operator carrying out the measurement (logged in); product name.
The software saves the measurement in a so called loop, i.e. when the measurement no. 100001 is saved, the measurement 1 gets automatically deleted from the memory.
Measurements saved to balance memory cannot be deleted.
You can preview and print out the data saved to the ALIBI database.
Mass for titrator

Mass for titrator

'Mass value for a titrator' working mode enables establishing connection between the weighing device and a titrator. The titrator receives information about the quantity of dispensed mass, and the weighing instrument receives a signal to start subsequent weighing.

Wi-Fi®

Wi-Fi®

Thanks to wireless communication between the computer and a balance, it is possible to use a balance inside a laminar flow hood and a fume cupboard.

Documentation
Cartes de produits
Data Sheet Data Sheet
Data Sheet

Voir
Voir
Download
Download

Choose more product:
Voir Voir DownloadDownload
Modes d'emploi
User Manual
User Manual
Voir
Voir
Download
Download
(25.49 MB)
21 CFR Part 11 Compliance Module
21 CFR Part 11 Compliance Module
Voir
Voir
Download
Download
(1.75 MB)
Quick start
Quick start
Voir
Voir
Download
Download
(2.47 MB)
Mode d'emploi - Balances de la serie X2
Mode d'emploi - Balances de la serie X2
Voir
Voir
Download
Download
(5.10 MB)
Start up Guide
Start up Guide
Voir
Voir
Download
Download
(1.22 MB)
Déclarations de conformité
Conformity Declaration
Conformity Declaration
Voir
Voir
Download
Download
(0.04 MB)
Publications et brochures
RTP Thermal Receipt Printer
RTP Thermal Receipt Printer
Voir
Voir
Download
Download
(1.64 MB)
Cimmunication Directe Balance Ordinateur Sans Application
Cimmunication Directe Balance Ordinateur Sans Application
Voir
Voir
Download
Download
(0.30 MB)
Acier inoxydable dans les balances RADWAG
Acier inoxydable dans les balances RADWAG
Voir
Voir
Download
Download
(2.27 MB)
Balances de la serie X2
Balances de la serie X2
Voir
Voir
Download
Download
(4.84 MB)
Profils Definis de Pesage
Profils Definis de Pesage
Voir
Voir
Download
Download
(1.63 MB)
Software
Drivers

RADWAG USB DRIVER 1.6.2 (1.25 MB)

Accessoires
R-LAB

Accessoires

Modules additionnels

RES Protocole de communication Radwag3
Module de conformité à 21 CFR partie 113

Radwag Balances Électroniques
Torunska 5
26-600 Radom
Poland
tel.: +48 48 386 60 00
e-mail: export@radwag.com
TIN: PL7960000327
Vimeo Radwag YouTube Radwag Facebook Radwag LinkedIn Radwag
© 2024 RADWAG Balances Électroniques. Tous les droits sont réservés.

Wybierz język

×
Change language AlbanianAlbanian
Change language DanishDanish
Change language NederlandseNederlandse
Change language EstonianEstonian
Change language FinnishFinnish
Change language HungarianHungarian
Change language IcelandicIcelandic
Change language KazakhKazakh
Change language LatvianLatvian
Change language LithuanianLithuanian
Change language MacedonianMacedonian
Change language NorwegianNorwegian
Change language PortuguesePortuguese
Change language RomanianRomanian
Change language RussianRussian
Change language SlovakSlovak
Change language SlovenianSlovenian
Change language SwedishSwedish
Change language UkrainianUkrainian
Change language SerbianSerbian
Change language MontenegrinMontenegrin
Change language page on Deutsch Deutsch
Change language page on English English
Change language page on Español Español
Change language page on Italiano Italiano
Change language page on Polski Polski
Change language page on Türkiye Türkiye
Česky
Português (Brasil)
Change website to USA USA
Change language page on 中文 中文
Presentations Presentations Presentations
Subscribe Subscribe Subscribe
Radwag in Facebook Radwag in Facebook Facebook
Radwag in YouTube Radwag in YouTube Youtube
Radwag in Vimeo Radwag in Vimeo Vimeo
Radwag in LinkedIn Radwag in LinkedIn LinkedIn
Webinars Radwag Webinars Radwag Webinars
close
E-mail:
Nom de l’entreprise :
Prénom:
I consent to the processing of my personal data for marketing purposes by Radwag Wagi Elektroniczne Witold Lewandowski.
I consent to receive marketing and product-related messages by electronic means from Radwag Wagi Elektroniczne Witold Lewandowski.
I have read the Privacy Policy of RADWAG Wagi Elektroniczne Witold Lewandowski.
lock_openI want to access the files
close
Slide to go back ↩