Selected language Français Français
Change language
Change language page on Deutsch DeutschChange language page on English EnglishChange language page on Español EspañolChange language page on Italiano ItalianoChange language page on Polski PolskiChange language page on Türkiye Türkiye ČeskyChange website to USA USAChange language page on 中文 中文

Pèse-Palette inoxydable WPT/4P 600H

Pèse-Palette inoxydable WPT/4P 600H - Radwag Les Balances Electroniques
This image is for reference only.

Code produit: WP-208-0001
Poser des questions sur le produit

Description

Capacité maximale [Max]: 600kg
Précision de lecture: 200g

La pèse-palette  stable, en acier inoxydable, à  4 senseurs est conçue pour le pesage de palettes. On peut placer une charge sur la

balance

à l’aide d’un chariot à fourche ou un pont roulant. La construction est équipée de roues de mouvement et de poignées, cela facilite à un degré considérable un transport au lieu d’utilisation. Le terminal de

balance

PUE C/31 avec un afficheur rétroéclairé LCD installé sur le câble. Le câble est protégé par une conduite électrique. 3 mètres est la longueur d’un câble qui connecte le terminal et la plate-forme.
 
C’est possible de réaliser la balance à bi-échelon pour une charge supplémentaire.

Fonctions

Plus/Minus Control

Plus/Minus Control

Control of sample's mass carried out with reference to specified MIN and MAX thresholds. The weight is considered to be correct if it is comprised within threshold values. A graphic visualisation of weighing result is displayed in a form of a bar graph.
Percent Weighing

Percent Weighing

Percent Weighing function is used for comparision of measured products with mass standard. Mass of a mass standard may be a numeric value taken from a database or it may be determined through a measurement process. Each measured product is compared to mass standard, mass of which is presumed as a model 100% ideal mass. For products weighing less than the mass standard, obtained results are lower than 100%, for products weighing more, the obtained results are greatly  exceeded.
Totalizing

Totalizing

Function adding new mass value to already obtained one. This allows to determine mass content of the mixture, being a composition of number of different consistence components. Totalizing is limited by maximum capacity parameter.
Parts counting

Parts counting

Function using mass measurement for determination of  measured items quantity. Mass of a single item is required for this process. It may be either estimated through weighment or taken from a database. For items counting the following algorithm is used: all items mass / single item mass = quantity. Function operation is supperted by a mechanism of Automatic Correction of Accuracy. This allows to update single item mass in course of the process. To a certain extend Automatic Correction of Accuracy eliminates error which may be a result of different mass values of seemingly alike single elements. For industry solutions items counting may be simultaneously carried out with checkweighing and dosing thus industry solutions feature audio signalling base informing that specified number of items has been weighed. It is possible to apply weighing systems using few platfroms of different MAX capacities and different accuracies.
Internal battery

Internal battery

Internal and rechargeable battery of SLA 6 V type (sealed lead acid) enables device operation without connecting the device to the mains (9h operation). The weighing instrument controls battery status and displays a respective pictogram on the screen.
Peak hold

Peak hold

Function registering the greatest temporary indication occurring in course of the weighing process. It is most often used in medical scales in order to hold the measurement indication.
Animal weighing

Animal weighing

Process of mass determination for a product which may unwillingly reposition within the weighing pan. Mass determination in such cases requires much longer period of time when compared to typical weighing process. It is the user who defines period of time needed for control of measured product mass. The user can thus optimize the function depending on the measured product characteristics.

Paramètres Techniques

Capacité maximale [Max]

600

 kg

Capacité minimale [Min]

4

 kg

Précision de lecture

200

 g

Étendue de tare

-600

 kg

Afficheur

LCD (rétro-éclairé)

 

Degré de protection

IP 68 construction, IP 68 (1h max)/69 terminal

 

Communication interface

RS232

 

Alimentation

100 ÷ 240 V AC 50 / 60 Hz + accumulateur

 

Temps de travail avec l'alimentation d'accumulateur

45 heures (temps moyen)

 

Température du travail

-10 ÷ +40

 °C

Humidité relative d'air

10% ÷ 85% RH sans condensation

 

Dimension du plateau

860×1200

 mm

Dimensions d'appareil

1330×860×80

 mm

Masse de balance avec le terminal

46

 kg

Documentation

Mode d'emploi
(2.95 MB)

Save
See the publication

Data Sheet
(0.71 MB) EN

Save
See the publication

Conformity Declaration
(0.03 MB) EN

Save
See the publication

Terminaux de Pesage et Balances Industrielles
(5.14 MB)

Save
See the publication

Measuring_instruments_in_industry
(0.05 MB) EN

Save
See the publication

Accessoires

Éditeur de Balances
R-LAB
RAD KEY
Pilote LabVIEW
Imprimante de tickets de caisse
Câbles d'alimentation de cigare-allume
Sorties de boucle de courant AP2-3
Câbles RS 232, RS 485
Câbles RS 232 (balance – imprimante EPSON)
Supports, Statifs, bras-supports
Afficheurs
Convertisseur RS232 – Ethernet

Radwag Balances Électroniques

Torunska 5
26-600 Radom
Poland
tel.: +48 48 386 60 00
e-mail: export@radwag.com
TIN: PL7960000327
Vimeo Radwag YouTube Radwag Facebook Radwag
© 2019 RADWAG Balances Électroniques. Tous les droits sont réservés.

See our movies
RADWAG

Radwag WEBINARS