Max: 150kgd: 50g

 800×800mm
Max: 150kgd: 50g

 1000×1000mm
Max: 300kgd: 100g

 800×800mm
Max: 300kgd: 100g

 1000×1000mm
Max: 300kgd: 100g

 1200×1200mm
Max: 600kgd: 200g

 1000×1000mm
Max: 600kgd: 200g

 1200×1200mm
Max: 600kgd: 200g

 800×800mm
Max: 600kgd: 200g

 1200×1500mm
Max: 1500kgd: 500g

 1200×1500mm
Max: 1500kgd: 500g

 800×800mm
Max: 1500kgd: 500g

 1200×1200mm
Max: 1500kgd: 500g

 1000×1000mm
Max: 1500kgd: 500g

 1500×1500mm
Max: 3000kgd: 1kg

 1500×1500mm
Max: 3000kgd: 1kg

 1200×1200mm
Max: 3000kgd: 1kg

 1500×2000mm
Max: 3000kgd: 1kg

 2000×2000mm
Max: 3000kgd: 1kg

 1200×1500mm
Max: 6000kgd: 2kg

 1500×2000mm
Max: 6000kgd: 2kg

 1500×1500mm
Max: 6000kgd: 2kg

 2000×2000mm
Description
La balance HX7.4 C est composée de l’indicateur PUE HX7 en acier inoxydable AISI 304 et d’une plate-forme à 4 capteurs en acier... więcej ››
Capacité maximale [Max]: 600kg
Précision de lecture: 200g

close
Select model:
Balance multifonctionnelle à plates-forme HX7.4.150.C6
Balance multifonctionnelle à plates-forme HX7.4.150.C7
Balance multifonctionnelle à plates-forme HX7.4.300.C6
Balance multifonctionnelle à plates-forme HX7.4.300.C7
Balance multifonctionnelle à plates-forme HX7.4.300.C8
Balance multifonctionnelle à plates-forme HX7.4.600.C7
Balance multifonctionnelle à plates-forme HX7.4.600.C9
Balance multifonctionnelle à plates-forme HX7.4.600.C8
Balance multifonctionnelle à plates-forme HX7.4.600.C6
Balance multifonctionnelle à plates-forme HX7.4.600.C8/9
Balance multifonctionnelle à plates-forme HX7.4.1500.C8/9
Balance multifonctionnelle à plates-forme HX7.4.1500.C6
Balance multifonctionnelle à plates-forme HX7.4.1500.C8
Balance multifonctionnelle à plates-forme HX7.4.1500.C7
Balance multifonctionnelle à plates-forme HX7.4.1500.C9
Balance multifonctionnelle à plates-forme HX7.4.3000.C9
Balance multifonctionnelle à plates-forme HX7.4.3000.C8
Balance multifonctionnelle à plates-forme HX7.4.3000.C10
Balance multifonctionnelle à plates-forme HX7.4.3000.C11
Balance multifonctionnelle à plates-forme HX7.4.3000.C8/9
Balance multifonctionnelle à plates-forme HX7.4.6000.C10
Balance multifonctionnelle à plates-forme HX7.4.6000.C9
Balance multifonctionnelle à plates-forme HX7.4.6000.C11
Select all
Voir
Download
Demandez un devis
Description
La balance HX7.4 C est composée de l’indicateur PUE HX7 en acier inoxydable AISI 304 et d’une plate-forme à 4 capteurs en acier pulvérisé.

L’indicateur est équipé d’un afficheur graphique, en couleurs. La nouveauté – le bargraphe à 9 champs LEDs qui s’allument en rouge et en vert. Le bargraphe présente la masse actuelle nette de la charge par rapport à la capacité de la balance ou aux seuils déterminés min. et max. La partie arrière du boîtier contient les connexions hermétiques des interfaces de communication RS232, RS485, USB, Ethernet, Entrées/Sorties digitales et une sortie analogique. Ils permettent le fonctionnement de la balance avec plusieurs appareils externes, par exemple : scanneurs de code à barres, imprimantes, afficheurs de masse externes, boutons de commande, colonnes de son et de lumière, autres dispositifs de contrôle et de signalisation, ainsi que systèmes de contrôle et de pilotage automatiques et systèmes informatiques supérieurs. La poignée permet le placement de l’indicateur sur toute surface horizontale plane et son visage au mur avec la possibilité du réglage de l’angle d’inclinaison.

Le logiciel de la balance permet d'effectuer les processus de pesage, de comptage de pièces, de dosage, d'étiquetage, de formulation et de contrôle des écarts. Dans les indicateurs, le système d’information est basé sur les bases de données : utilisateurs, produits, pesages, emballages, recettes, clients et mémoire Alibi. Alibi garantit la sécurité des données collectées.
Validation comme option supplémentaire
Stainless Steel in RADWAG products
Learn about the use and maintenance of stainless steel products:
Acier inoxydable dans les balances RADWAG
Paramètres Techniques
Capacité maximale [Max]

600

 kg

Capacité minimale [Min]

4

 kg

Précision de lecture

200

 g

Étendue de tare

-600

 kg

Échelon de légalisation [e]

200

 g

Précison de lecture maximale pour les balances non vérifiées

50

 g

Classe de précision OIML

III

 

Afficheur

7” graphique couleurs

 

Dimension du plateau

1500×1500

 mm

Dimensions de colis

1600×1600×500

 mm

Masse nette

164,7

 kg

Masse brute

204,3

 kg

Degré de protection

IP 65 construction, IP 66/68 terminal

 

Terminal

PUE HX7

 

Nombre de touches

22

 

Interface USB

1× standard, 1× en option

 

Interface ETHERNET

1× standard

 

Interface EtherNet/IP

1 × en option (RJ45)

 

Interface Profinet

1 × en option (RJ45)

 

Interface RS232

1× standard, 1× en option

 

RS485

1× en option

 

Interface IN/OUT

4 IN 4 OUT standard, 12 IN 12 OUT en option

 

Module Modbus RTU

1× standard

 

Module de sorties analogiques (option)

4-20mA, 0-10V

 

Alimentation

100 — 240 V AC 50/60 Hz

 

Prise de courant maximale

25 W

 

Alimentation optionnelle

12-24V DC

 

Température du travail

-10 — +40

 °C

Température de stockage

-10 — +50

 °C

Humidité relative d'air

10% — 80% RH sans condensation

 

Clavier

de membrane

 

Construction

acier pulvériséeacier St3S

 

Nombre maximal de plate-formes desservies

2

 

Fonctions
Dosing

Dosing

Weighing process for which reference mass has been determined together with tolerance for its determination. Dosing tolerance is given in [%] and it is calculated in relation to the reference value thus being a permissible deviation of this process. This solution is used for weighing powders, liquids and loose materials. Dosing function performance is often supported with bargraph - load indicator. For industrial scales it is possible to use a control systems of dosing process.
Percent Weighing

Percent Weighing

Percent Weighing function is used for comparision of measured products with mass standard. Mass of a mass standard may be a numeric value taken from a database or it may be determined through a measurement process. Each measured product is compared to mass standard, mass of which is presumed as a model 100% ideal mass. For products weighing less than the mass standard, obtained results are lower than 100%, for products weighing more, the obtained results are greatly  exceeded.
Parts counting

Parts counting

Function using mass measurement for determination of  measured items quantity. Mass of a single item is required for this process. It may be either estimated through weighment or taken from a database. For items counting the following algorithm is used: all items mass / single item mass = quantity. Function operation is supperted by a mechanism of Automatic Correction of Accuracy. This allows to update single item mass in course of the process. To a certain extend Automatic Correction of Accuracy eliminates error which may be a result of different mass values of seemingly alike single elements. For industry solutions items counting may be simultaneously carried out with checkweighing and dosing thus industry solutions feature audio signalling base informing that specified number of items has been weighed. It is possible to apply weighing systems using few platfroms of different MAX capacities and different accuracies.
Formulation

Formulation

Function supporting the mixture making process, wherein the mixture contains various components. Formulation function usually uses the balance/scale database of components. Formulation serves for monitored checkweighing of every single component with a given tolerance. It is enriched with a set of individual settings.
Replaceable unit

Replaceable unit

Replaceable units.
ALIBI Memory

ALIBI Memory

"ALIBI" memory enables saving and storing up to 100000 measurements.  Measurements are saved automatically upon each pressing of the key. There is no need for any additional operations or changing settings.
The following data related with the measurements is saved: measurement date; measurement time; result (mass); tare value; operator carrying out the measurement (logged in); product name.
The software saves the measurement in a so called loop, i.e. when the measurement no. 100001 is saved, the measurement 1 gets automatically deleted from the memory.
Measurements saved to balance memory cannot be deleted.
You can preview and print out the data saved to the ALIBI database.
Documentation
Cartes de produits
Data Sheet


Voir

Download

Choose more product:
Voir Download
Modes d'emploi
Mode d'emploi - CBCP 02

Voir

Download
(0.25 MB)
User Manual - HX7

Voir

Download
(2.11 MB)
Start up Guide

Voir

Download
(1.81 MB)
Mode d'emploi

Voir

Download
(1.79 MB)
Software Manual - Appendices 02

Voir

Download
(0.74 MB)
Software Manual - EtherNet/IP communication protocol PUE HX7

Voir

Download
(2.02 MB)
Software Manual - PROFIBUS communication protocol PUE HX7

Voir

Download
(1.22 MB)
Software Manual - PUE HX7

Voir

Download
(3.00 MB)
Software Manual - MODBUS RTU communication protocol of PUE HX7

Voir

Download
(0.88 MB)
Quick start

Voir

Download
(2.47 MB)
Déclarations de conformité
Conformity Declaration

Voir

Download
(0.04 MB)
Publications et brochures
Terminal PUE HX7

Voir

Download
(1.95 MB)
Acier inoxydable dans les balances RADWAG

Voir

Download
(2.46 MB)
Terminaux et Plates-Formes

Voir

Download
(3.71 MB)
HX7 Multifinctional Industrial Scales

Voir

Download
(14.08 MB)
Software
Drivers

LabVIEW (3.05 MB)

GSD Profibus (5 KB)

EDS EtherNetIP (1.931 KB)

Accessoires
Rampes
Alibi Reader

Accessoires

E2R System

Accessoires

Éditeur D’étiquettes R02
R.Barcode

Accessoires

R-LAB

Accessoires

RAD KEY

Accessoires

RADWAG Connect

Accessoires

RADWAG Studio du Développement
Pilote LabVIEW
Imprimantes d étiquettes
Convertisseur RS 232 – USB
Câbles RS 232 (balance – imprimante ZEBRA)

Accessoires

Adapteur USB

Accessoires

Câbles RS 232 (balance – imprimante EPSON)

Accessoires

Câbles RS 232, RS 485
Câble USB (balance – imprimante)
Câbles d'Entrées/ de Sorties

Accessoires

Lecteurs de code-barres
Radwag Balances Électroniques
Torunska 5
26-600 Radom
Poland
tel.: +48 48 386 60 00
e-mail: export@radwag.com
TIN: PL7960000327
Vimeo Radwag YouTube Radwag Facebook Radwag LinkedIn Radwag
© 2022 RADWAG Balances Électroniques. Tous les droits sont réservés.

Wybierz język

×
Change language AlbanianAlbanian
Change language DanishDanish
Change language NederlandseNederlandse
Change language EstonianEstonian
Change language FinnishFinnish
Change language HungarianHungarian
Change language IcelandicIcelandic
Change language KazakhKazakh
Change language LatvianLatvian
Change language LithuanianLithuanian
Change language MacedonianMacedonian
Change language NorwegianNorwegian
Change language PortuguesePortuguese
Change language RomanianRomanian
Change language RussianRussian
Change language SlovakSlovak
Change language SlovenianSlovenian
Change language SwedishSwedish
Change language UkrainianUkrainian
Change language SerbianSerbian
Change language MontenegrinMontenegrin
Change language page on Deutsch Deutsch
Change language page on English English
Change language page on Español Español
Change language page on Italiano Italiano
Change language page on Polski Polski
Change language page on Türkiye Türkiye
Česky
Change website to USA USA
Change language page on 中文 中文
Subscribe
Facebook
Youtube
Vimeo
LinkedIn
Webinars
close
close
Voulez-vous nous demander quelque chose?
Appelez-nous: +48 48 386 60 00
Nous répondrons à toutes vos questions.