Balanza de precisión PS 4500.X2.M

Radwag Balanzas Electrónicas
Selected language Español
Obraz
This image is for reference only.

Balanza de precisión PS 4500.X2.M

Código de producto: WL-218-0103
Change the model (13)
done
Max: 4500gd: 10mg

 195×195mm
expand_more
Max: 200 / 2000gd: 1 / 10mg

 128×128mm
Max: 210gd: 1mg

 128×128mm
Max: 360gd: 1mg

 128×128mm
Max: 600gd: 1mg

 128×128mm
Max: 750gd: 1mg

 128×128mm
Max: 1000gd: 1mg

 128×128mm
Max: 2100gd: 10mg

 195×195mm
Max: 3000gd: 1mg

 128×128mm
Max: 3500gd: 10mg

 195×195mm
Max: 6100gd: 10mg

 195×195mm
Max: 8100gd: 10mg

 195×195mm
Max: 10100gd: 10mg

 195×195mm
Maxima capacidad [Max]: 4500 g
Legibilidad [d]: 10 mg

close
Change the model:
Balanza de precisión PS 200/2000.X2
Balanza de precisión PS 210.X2
Balanza de precisión PS 360.X2
Balanza de precisión PS 600.X2
Balanza de precisión PS 750.X2
Balanza de precisión PS 1000.X2
Balanza de precisión PS 2100.X2.M
Balanza de precisión PS 3000.X2
Balanza de precisión PS 3500.X2.M
Balanza de precisión PS 4500.X2.M
Balanza de precisión PS 6100.X2.M
Balanza de precisión PS 8100.X2.M
Balanza de precisión PS 10100.X2.M
Select all
Ver
Guardar
Para comparar Búsqueda avanzada
Descripción

Balanza de precisión PS 4500.X2.M

 

PS X2.M

Las balanzas profesionales de precisión de gran capacidad PS X2M, se basan en la tecnología de  Radwag

MONO

BLOCK
. Este innovador diseño de las balanzas de la serie PS X2.M se caracteriza por un nuevo método sujeción del platillo en solo un punto, que garantiza muy buena geometría y minimiza el error de excentricidad , mientras que  diseño laberíntico garantiza un alto nivel de resistencia a la contaminación.
 
 
 

MONO

BLOCK

El uso de la tecnología

MONO

BLOCK
permite pesar cargas con una precisión de d = 0.01g con una capacidad de hasta 10 kg. Una base robusta e rígida garantiza la estabilidad del sistema de pesaje y una alta resistencia para los impactos.

El sistema de adjustación interna garantiza la precisión y alta repetibilidad de los resultados de las mediciones. El movimiento del peso interno permite la adjustación interna en todo el rango de medición.
 
 
 

Las principales características de la serie PS X2.M:

  • una precisión de d = 0.01g con una capacidad de pesaje de hasta 10 kg
  • alto nivel de resistencia a los factores externos
  • garantía de estabilidad y repetibilidad
  • aplicación de la tecnología

    MONO

    BLOCK
  • adjustación interna en el todo rango de medición
  • amplias bases de datos  y memoria ALIBI
  • panel táctil en color ergonómico de 5"
  • posibilidad de trabajo sin el contacto (Non-contact Mode)
 
 
 

Bases de datos

Este dispositivo permite el registro de datos de pesadas en forma de informes y tablas. Los datos se pueden recopilar hasta en siete bases de datos:
  • Usuarios (hasta 100 usuarios),
  • Productos (hasta 5,000 productos),
  • Pesaje (hasta 50,000 pesadas),
  • Embalaje (hasta 100 paquetes),
  • Recetas (hasta 100 recetas),
  • Clientes (hasta 1000 clientes),
  • Memoria  ALIBI (hasta 512 000 pesajes).
También es posible crear los informes a partir de las recetas (hasta 500 informes).
 
 
 
 

Memoria ALIBI

La memoria ALIBI garantiza una seguridad y permite un automático registro de mediciones, de hasta 512.000 registros de pesaje.
 
 
 

Comunicación

La serie PS X2.M está equipada con los siguientes interfaces de comunicación: 2 x RS 232, USB tipo A, USB tipo B, EthernetWi-Fi®.

El USB permite una rápida transferencia y la copia de los resultados de trabajo (mediciones, informes, bases de datos) a una computadora u otra balanza. También es posible administrar datos de la balanza de manera remota.
 
 
Stainless Steel in RADWAG products
Learn about the use and maintenance of stainless steel products:
Stainless Steel in RADWAG products. Standard and special applications

Wi-Fi® es una marca registrada de Wi-Fi Alliance®.
Datos tecnicos
Maxima capacidad [Max]

4500

 g

Minima capacidad

500

 mg

Legibilidad [d]

10

 mg

División de legalización [e]

100

 mg

Rango de tara

-4500

 g

Repetibilidad estándar [5% Máx.]

5

 mg

Repetibilidad estándar [Máx.]

8

 mg

Porción mínima estándar (USP)

10

 g

Porción mínima estándar (U = 1%, k = 2)

1

 g

Linealidad

±20

 mg

Tiempo de estabilización

1,5

 s

Calibración

interna (automatica)

 

Clase OIML

II

 

Sistema de nivelación

manual

 

Pantalla

5” pantalla táctil gráfica de color

 

Elementos del set

Balanza, platillo, protección del platillo, adaptador de CA

 

Dimensión de platillo

195×195

 mm

Dimensiones de aparato

333x206x107

 mm

Dimensiones de embalaje

475×380×345

 mm

Masa neta

4,33

 kg

Masa bruta

5,5

 kg

Grado de protección

IP 43

 

Tamaño de base de datos

7

 

Touchless operation

2 sensores infrarrojos

 

Conectividad

2×RS232¹, USB-A, USB-B, Ethernet, Wi-Fi®

 

Alimentacion

Adapter: 100 – 240V AC 50/60Hz 0,6A; 12V DC 1,2A
Balanza: 12 – 15V DC 0,8A max

 

Potencia consumida por el dispositivo

4 W

 

Temperatura de trabajo

+10 – +40

 °C

Indicador de condiciones de ambiente (opcional)

THBR 2.0 System, THBR BOX, THB P, THB W, THB S

 

Temperatura de almacenamiento

-20 – +50

 °C

Humedad relativa de aire

40% – 80%

 

CE
Legalización Extra payment
for verification
La repetibilidad se expresa como una desviación estándar de 10 posiciones de carga.
El tiempo de estabilización depende de las condiciones externas y la dinámica de colocar los pesos en el platillo; especificado para el perfil FAST.
1 Los lectores de códigos de barras disponibles como accesorio cooperan con la balanza utilizando solo la interfaz RS232.
360°
Vídeos
X2 Balances: WEIGHING - Working modes: part 1
Impresión fácil con las impresoras térmicas de recibos Wifi® de RADWAG
Connecting RADWAG RTP-UEW80 Printer via Wi-Fi® (Tutorial)
PS R2 Precision Balance Unpacking and Installation (Tutorial)
Parts Counting function in Radwag weighing instruments
RTP - The First Receipt Printer of RADWAG Production!
Complete Solutions for Mass Measurement in Pharma Industry
X2 Balances: STATISTICS - Working modes: part 8
X2 Balances: LIQUIDS DENSITY - Working modes: part 7
X2 Balances: SOLIDS DENSITY - Working modes: part 6
X2 Balances: PERCENT WEIGHING - Working modes: part 5
X2 Balances: PARTS COUNTING - Working modes: part 4
X2 Balances: CHECKWEIGHING - Working modes: part 3
X2 Balances: DOSING - Working modes: part 2
X2 Synergy Balances: operating modes overview
X2 Synergy Balances
Funciones
Autotest

Autotest

Diagnostic function aiming at metrological parameters determination (repeatability), the parameters are determined for the actual conditions of use. When speaking of repeatability it may be also used for weighing time optimization. Autotest is operated in an automatic mode thus operator’s time is saved.
Dosing

Dosing

Weighing process for which reference mass has been determined together with tolerance for its determination. Dosing tolerance is given in [%] and it is calculated in relation to the reference value thus being a permissible deviation of this process. This solution is used for weighing powders, liquids and loose materials. Dosing function performance is often supported with bargraph - load indicator. For industrial scales it is possible to use a control systems of dosing process.
Plus/Minus Control

Plus/Minus Control

Control of sample's mass carried out with reference to specified MIN and MAX thresholds. The weight is considered to be correct if it is comprised within threshold values. A graphic visualisation of weighing result is displayed in a form of a bar graph.
Percent Weighing

Percent Weighing

Percent Weighing function is used for comparision of measured products with mass standard. Mass of a mass standard may be a numeric value taken from a database or it may be determined through a measurement process. Each measured product is compared to mass standard, mass of which is presumed as a model 100% ideal mass. For products weighing less than the mass standard, obtained results are lower than 100%, for products weighing more, the obtained results are greatly  exceeded.
Parts counting

Parts counting

Function using mass measurement for determination of  measured items quantity. Mass of a single item is required for this process. It may be either estimated through weighment or taken from a database. For items counting the following algorithm is used: all items mass / single item mass = quantity. Function operation is supperted by a mechanism of Automatic Correction of Accuracy. This allows to update single item mass in course of the process. To a certain extend Automatic Correction of Accuracy eliminates error which may be a result of different mass values of seemingly alike single elements. For industry solutions items counting may be simultaneously carried out with checkweighing and dosing thus industry solutions feature audio signalling base informing that specified number of items has been weighed. It is possible to apply weighing systems using few platfroms of different MAX capacities and different accuracies.
Peak hold

Peak hold

Function registering the greatest temporary indication occurring in course of the weighing process. It is most often used in medical scales in order to hold the measurement indication.
Formulation

Formulation

Function supporting the mixture making process, wherein the mixture contains various components. Formulation function usually uses the balance/scale database of components. Formulation serves for monitored checkweighing of every single component with a given tolerance. It is enriched with a set of individual settings.
Statistics

Statistics

Statistiscs function registers and analyses performed measurements. This supplies the user withthe following information: Max and Min standard deviation, average value, variance, range et.
Checkweighing

Checkweighing

Checkweighing function is used for checking whether the measured sample mass is within the predefined threshold values, Low [LO] and Hgh [HI]. The thresholds are given in [g] and [kg] units. Current state of a sample being measured is signalled by means of pictorgams located on a display for laboratory balances, for industrial scales Stackligt System is used. This visual +/- inspection is in operation during segregation, control or packing process of products for which mass has bees determined with a specifaied tolerance, eg. 12860 g 961
IR sensors

IR sensors

Programmable function supporting the weighing process through control of the following options: sliding weighing chamber doors, printout, zeroing, tarring etc. Especially appreciated wherever preventing the balance from soiling is important.
Under-pan weighing

Under-pan weighing

The solution enables weighing with use of a stand, which is advisable for loads of non-standard shapes and dimensions and those that generate magnetic field.
GLP Procedures

GLP Procedures

Diagnostic function allowing to objectively document performed measurements. GLP procedures may be either presented in a short report form or extended one.
Animal weighing

Animal weighing

Process of mass determination for a product which may unwillingly reposition within the weighing pan. Mass determination in such cases requires much longer period of time when compared to typical weighing process. It is the user who defines period of time needed for control of measured product mass. The user can thus optimize the function depending on the measured product characteristics.
Density determination

Density determination

Liquid or solid body density function uses the Archimedes principle and it requires a special kit to be applied. The kit when used, replaces a weighing pan. For solids mass of the sample must be determined first in the air, next in the liquid of specified density. For liquids the so called sinker, density of which has been determined, must be measured first in the air, next in the tested liquid. The density determination process is disturbed by air bubbles which may stick either to the measured sample or the sinker. In case of laboratory equipment very light solids may be measured. For industry, solid bodies density may be determined by means of  under-pan weighing. Tested load of significant size may be measured this way.
Ambient conditions monitoring

Ambient conditions monitoring

The possibility of cooperation with the THBR 2.0 system
Replaceable unit

Replaceable unit

Replaceable units.
Statistical Quality Control

Statistical Quality Control

Statistical control for determination of basic statistical criteria: maximum, minimum, standard deviation, mean values for each batch, etc.
ALIBI Memory

ALIBI Memory

"ALIBI" memory enables saving and storing up to 100000 measurements.  Measurements are saved automatically upon each pressing of the key. There is no need for any additional operations or changing settings.
The following data related with the measurements is saved: measurement date; measurement time; result (mass); tare value; operator carrying out the measurement (logged in); product name.
The software saves the measurement in a so called loop, i.e. when the measurement no. 100001 is saved, the measurement 1 gets automatically deleted from the memory.
Measurements saved to balance memory cannot be deleted.
You can preview and print out the data saved to the ALIBI database.
Mass for titrator

Mass for titrator

'Mass value for a titrator' working mode enables establishing connection between the weighing device and a titrator. The titrator receives information about the quantity of dispensed mass, and the weighing instrument receives a signal to start subsequent weighing.

Wi-Fi®

Wi-Fi®

Thanks to wireless communication between the computer and a balance, it is possible to use a balance inside a laminar flow hood and a fume cupboard.

Documentación
Tarjetas de productos
Data Sheet Data Sheet
Data Sheet

Ver
Ver
Guardar
Guardar

Choose more product:
Ver Ver GuardarGuardar
Manual de usuario
User Manual
User Manual
Ver
Ver
Guardar
Guardar
(25.49 MB)
Módulo de cumplimiento de 21 CFR Parte 11
Módulo de cumplimiento de 21 CFR Parte 11
Ver
Ver
Guardar
Guardar
(1.89 MB)
Manual de instrucciones - Balanzas de la serie X2
Manual de instrucciones - Balanzas de la serie X2
Ver
Ver
Guardar
Guardar
(7.30 MB)
Inicio rápido
Inicio rápido
Ver
Ver
Guardar
Guardar
(1.22 MB)
Declaraciones de conformidad
Conformity Declaration
Conformity Declaration
Ver
Ver
Guardar
Guardar
(0.04 MB)
Publicaciones y folletos
Laboratory balance cleaning
Laboratory balance cleaning
Ver
Ver
Guardar
Guardar
(2.52 MB)
RTP Thermal Receipt Printer
RTP Thermal Receipt Printer
Ver
Ver
Guardar
Guardar
(1.64 MB)
Communicacion Directa Balanza-PC
Communicacion Directa Balanza-PC
Ver
Ver
Guardar
Guardar
(0.32 MB)
Diccionario de Términos Metrológicos Básicos
Diccionario de Términos Metrológicos Básicos
Ver
Ver
Guardar
Guardar
(17.15 MB)
Laboratory Balances
Laboratory Balances
Ver
Ver
Guardar
Guardar
(1.68 MB)
Stainless Steel in RADWAG products. Standard and special applications
Stainless Steel in RADWAG products. Standard and special applications
Ver
Ver
Guardar
Guardar
(2.23 MB)
Balanzas de la Serie X2
Balanzas de la Serie X2
Ver
Ver
Guardar
Guardar
(5.06 MB)
Perfiles Definidos
Perfiles Definidos
Ver
Ver
Guardar
Guardar
(1.65 MB)
Programas
Drivers

RADWAG USB DRIVER 1.6.2 (1.25 MB)

Accesorios
R-LAB

Accesorios

Módulos adicionales

RES Protocolo de comunicación Radwag3
Módulo de cumplimiento con 21 CFR parte 113

Newsletter

If you wish to receive the latest news about RADWAG products and services, sign up for the newsletter.

More
RADWAG Balanzas Electrónicas
Torunska 5
26-600 Radom
Poland
tel.: +48 48 386 60 00
e-mail: export@radwag.com
TIN: PL7960000327
Vimeo Radwag YouTube Radwag Facebook Radwag LinkedIn Radwag
© 2024 RADWAG Balances and Scales. All rights reserved.

Selecionar idioma

×
Change language AlbanianAlbanian
Change language DanishDanish
Change language NederlandseNederlandse
Change language EstonianEstonian
Change language FinnishFinnish
Change language HungarianHungarian
Change language IcelandicIcelandic
Change language KazakhKazakh
Change language LatvianLatvian
Change language LithuanianLithuanian
Change language MacedonianMacedonian
Change language NorwegianNorwegian
Change language PortuguesePortuguese
Change language RomanianRomanian
Change language RussianRussian
Change language SlovakSlovak
Change language SlovenianSlovenian
Change language SwedishSwedish
Change language UkrainianUkrainian
Change language SerbianSerbian
Change language MontenegrinMontenegrin
Change language page on Deutsch Deutsch
Change language page on English English
Change language page on Français Français
Change language page on Italiano Italiano
Change language page on Polski Polski
Change language page on Türkiye Türkiye
Česky
Português (Brasil)
Change website to USA USA
Change language page on 中文 中文
Presentations Presentations Presentations
Subscribe Subscribe Subscribe
Radwag in Facebook Radwag in Facebook Facebook
Radwag in YouTube Radwag in YouTube Youtube
Radwag in Vimeo Radwag in Vimeo Vimeo
Radwag in LinkedIn Radwag in LinkedIn LinkedIn
Webinars Radwag Webinars Radwag Webinars
close
E-mail:
Nombre de empresa
Nombre:
I consent to the processing of my personal data for marketing purposes by Radwag Wagi Elektroniczne Witold Lewandowski.
I consent to receive marketing and product-related messages by electronic means from Radwag Wagi Elektroniczne Witold Lewandowski.
I have read the Privacy Policy of RADWAG Wagi Elektroniczne Witold Lewandowski.
lock_openI want to access the files
close
Slide to go back ↩