Maximum capacity [Max] |
22 g |
Minimum load |
0.1 mg |
Readability [d] |
1 µg |
Verification unit [e] |
1 mg |
Tare range |
-21 g |
Standard minimum weight (USP) |
2.6 mg |
Standard minimum weight (U=1%, k=2) |
0.26 mg |
Repeatability |
0.0007 mg (at 1 g) |
Linearity |
0.0007 mg |
Eccentric load deviation |
15 µg |
Sensitivity time drift |
1×10⁻⁶/Year×Rt |
Stabilization time |
3.5 s |
Adjustment |
internal (automatic) |
OIML Class |
I |
Leveling system |
automatic - Reflex Level System |
Display |
10″ graphic colour touchscreen |
Weighing chamber doors |
automatic |
Delivery components |
Microbalance, weighing pan, weighing pan shield, power supply, automatic pipette calibration adapter: (base, bottom ring, glass vessel, pipette calibration adapter, evaporation ring, weighing pan, glass lid, mechanical closing cover, protecting screw), brush, fabric dust cover. |
Weighing chamber dimensions |
199×170×217 mm |
Capacity |
11 ml |
Weighing pan dimensions |
ø26 mm |
Packaging dimensions |
750×492×595 mm |
Net weight |
14.5 kg |
Gross weight |
18.9 kg |
Protection class |
IP 43 |
Communication interface |
2×USB-A, USB-C, HDMI, Ethernet, Wi-Fi®, Hotspot |
Power supply |
Adapter: 100 – 240V AC 50/60Hz 1A; 15V DC 2.4A Balance: 12 – 15V DC 1.4A max* |
Operating temperature |
+10 — +40 °C |
Operating temperature change rate |
±0.3°C/1h (±1°C/8h) |
Relative humidity |
40% — 80% |
Relative humidity change rate |
±1%/h (±4%/8h) |
Extra payment
for verification
* The power supply can be connected to the socket on the back of the balance housing or to the terminal.
Pipette verification range: 1 – 100 μl
Status indicator Light: Balance will have Light indication for various status of balance like Ok, calibration over due, levelling error and other such warnings.
Display: 10" color touchscreen (glove compatible*)
Temperature Control of Weighing Chamber: Balance weighing cell chamber is equipped with temperature control mechanism to control temperature of weighing cell chamber by removing heat generated by electronics.
User Management: Balance allows to define user and users groups. User Management such as setting password, user rights, user groups rights should be allowed to configure. Balance allows to create more than 50 users with credentials (Password)
Internal Adjustment: Time and Temperature based adjustment with internal weights
Level Adjustment Guide: Balance provides level warning in case of out of level and should not allow user to add result to protocol if balance is not levelled. Graphical level bubble is provided for levelling
Capacity of evaporation tank: 10 ml
Evaporation Trap: Motor Driven removable Evaporation trap
Touchless operation: Light barrier will be provided for touch less operation of evaporation trap door
* Experimentally tested with most common thin rubber gloves used at the laboratories.