Präzisionswaage PS 360.R2

Radwag Elektronische Waagen
Selected language Deutsch
Obraz
Übersichtsbild

Präzisionswaage PS 360.R2

Produktcode: WL-212-0019
Modell ändern (13)
done
Max: 360gd: 1mg

 128×128mm
expand_more
Max: 200 / 2000gd: 1 / 10mg

 128×128mm
Max: 210gd: 1mg

 128×128mm
Max: 600gd: 1mg

 128×128mm
Max: 600gd: 10mg

 195×195mm
Max: 750gd: 1mg

 128×128mm
Max: 1000gd: 1mg

 128×128mm
Max: 2100gd: 10mg

 195×195mm
Max: 3500gd: 10mg

 195×195mm
Max: 4500gd: 10mg

 195×195mm
Max: 6100gd: 10mg

 195×195mm
Max: 8100gd: 10mg

 195×195mm
Max: 10100gd: 10mg

 195×195mm
Wägebereich [Max]: 360 g
Ziffernschritt [d]: 1 mg

close
Modell ändern:
Präzisionswaage PS 200/2000.R2
Präzisionswaage PS 210.R2
Präzisionswaage PS 360.R2
Präzisionswaage PS 600.R2
Präzisionswaage PS 600.R2.1
Präzisionswaage PS 750.R2
Präzisionswaage PS 1000.R2
Präzisionswaage PS 2100.R2.M
Präzisionswaage PS 3500.R2.M
Präzisionswaage PS 4500.R2.M
Präzisionswaage PS 6100.R2.M
Präzisionswaage PS 8100.R2.M
Präzisionswaage PS 10100.R2.M
zum Vergleich Erweiterte Suche
Beschreibung
 

Präzisionswaage PS 360.R2

 
Waagen der Serie PS R2 setzten neue Maßstäbe bei Standardpräzisionswaagen. Die Waagen sind mit einem neuen, übersichtlichen LCD-Display ausgestattet, der eine noch bessere Präsentation der Wägeergebnisse ermöglicht. Auf dem Display wurde eine Informationszeile hinzugefügt, auf der zusätzliche Meldungen und Informationen z.B. Warenbezeichnungen oder Tarawerte eingeblendet werden.
 
 
 
 

Die PS R2 Waagen

Die Präzision und Zuverlässigkeit der Messungen sichert die automatische, interne Justierung, bei der die Temperaturschwankungen und der Zeitverlauf berücksichtigt werden.
 
Die PS R2 Waagen sind mit mehreren Schnittstellen zur Kommunikation ausgestattet: 2 x RS-232, USB-A, USB-B und optional Wireless-Module.
 
Das Gehäuse besteht aus Kunststoff und die Waagschale aus Edelstahl.
 
Es besteht die Möglichkeit das Wägegut außerhalb der Wägebrücke zu wägen (sog. Unterflurwägung) - das Wägegut wird unter der Waage gewogen.
 
 
 
 

Datenbanken


In neuen Waagen der Serie R basiert das Informationssystem auf
5 Datenbanken, die mehreren Benutzern Zugriff auf die Warendatenbank ermöglicht, alle gespeicherten Daten können ausgewertet werden.

Abspeichern der Daten in 5 Datenbanken:
  • Benutzer (bis zu 10 Einträge),
  • Waren (bis zu 1.000 Einträge),
  • Wägungen (bis zu 5.000 Einträge),
  • Tara (bis zu 100 Einträge),
  • ALIBI-Speicher (bis zu 100.000 Einträge).
 
.
 
 
 
 

USB-Schnittstelle

Die Waage, angeschlossen über die USB-Schnittstelle kann mit einem Rechner zusammenarbeiten, für diese Betriebsart ist jedoch zusätzliche Software (Treiber) erforderlich, die auf der Webseite unter "Software" oder "SUPPORT" zur Verfügung steht.

Der Datenaustausch im Rahmen des Systems verläuft in zwei Richtungen mit Hilfe einer schnellen USB-Schnittstelle. Die neuen Waagen unterstützen den Import und Export von Datenbanken auf USB-Speichermedien.
Der direkte Zugriff zu Funktionen und Datenbanken ist von der Ebene der Tastatur möglich:
  • Database - direkter Zugriff auf die Datenbanken,
  • Function - direkter Zugriff auf Grundfunktionen,
  • F1 bis F4 - programmierbare Funktionstasten und Menü-Navigationstasten.
 
 
 
 

Alibi-Speicher

Der verwendete ALIBI-Speicher ist ein Bereich der Datensicherheit und erlaubt das Abspeichern von bis zu 100.000 Wägesätzen. Dies garantiert die Sicherheit der Datenerfassung über einen langen Zeitraum.
 
 
Unterschalenwägung
Waagen, die nach dem 15.02.2023 gekauft wurden, ermöglichen Unterflurwägung zu einem beliebigen Zeitpunkt nach dem Kauf des Geräts. Alles, was Sie tun müssen, ist, einen speziellen Haken zu erwerben.
 
 
Edelstahl in RADWAG-Produkten
Erfahren Sie mehr über die Verwendung und Pflege von Edelstahlprodukten:
Rostfreier Stahl in RADWAG-Produkten. Standard- und Spezialanwendungen
Technische Daten
Wägebereich [Max]

360

 g

Min. Belastung

20

 mg

Ziffernschritt [d]

1

 mg

Eichwert [e]

10

 mg

Tarierbereich

-360

 g

Standard Wiederholbarkeit [5% Max]

0,5

 mg

Standard Wiederholbarkeit [Max]

1

 mg

Min. Einwaage (USP)

1

 g

Min. Einwaage (U=1%, k=2)

0,1

 g

Linearität

±2

 mg

Stabilisierungszeit

2

 s

Justierung

intern (automatisch)

 

OIML-Klasse

II

 

Nivelliersystem

manuell

 

Display

LCD (hinterleuchtet)

 

Lieferumfang

Waage, Waagschale, Waagschalenabdeckung, Erdungsfuß ×1, Fußzeile ×3, Netzteil.

 

Waagschale

128×128

 mm

Verpackungsgröße

475×380×345

 mm

Nettogewicht

3,7

 kg

Bruttogewicht

5

 kg

Schutzart

IP 43

 

Schnittstellen

2×RS232¹, USB-A, USB-B, Wi-Fi® (optional)

 

Stromversorgung

Adapter: 100 – 240V AC 50/60Hz 0,6A; 12V DC 1,2A
Waage: 12 – 15V DC 0,4A max

 

Leistungsaufnahme des Geräts

4 W

 

Umgebungstemperatur

+10 – +40

 °C

Relative Luftfeuchtigkeit

40% – 80%

 

CE
 Eichung Extra payment
for verification
Wiederholbarkeit wird als Standardabweichung von 10 Wägezyklen ausgedrückt.
Die Stabilisierungszeit ist abhängig von den Umgebungsbedingungen und der Geschwindigkeit bei Auflegen der Last auf der Waagschale; für FAST-Profil definiert.
1 Die als Zubehör erhältlichen Barcode-Scanner arbeiten mit der Waage nur über die RS232-Schnittstelle.
360°
Videos
Einfaches Drucken mit Thermo-Belegdrucker mit Wi-Fi®®
Connecting RADWAG RTP-UEW80 Printer via Wi-Fi® (Tutorial)
PS R2 Precision Balance Unpacking and Installation (Tutorial)
RTP - The First Receipt Printer of RADWAG Production!
Complete Solutions for Mass Measurement in Pharma Industry
Laborwaagen der R-Serie
Funktionen
Autotest

Autotest

Diagnostic function aiming at metrological parameters determination (repeatability), the parameters are determined for the actual conditions of use. When speaking of repeatability it may be also used for weighing time optimization. Autotest is operated in an automatic mode thus operator’s time is saved.
Dosing

Dosing

Weighing process for which reference mass has been determined together with tolerance for its determination. Dosing tolerance is given in [%] and it is calculated in relation to the reference value thus being a permissible deviation of this process. This solution is used for weighing powders, liquids and loose materials. Dosing function performance is often supported with bargraph - load indicator. For industrial scales it is possible to use a control systems of dosing process.
Percent Weighing

Percent Weighing

Percent Weighing function is used for comparision of measured products with mass standard. Mass of a mass standard may be a numeric value taken from a database or it may be determined through a measurement process. Each measured product is compared to mass standard, mass of which is presumed as a model 100% ideal mass. For products weighing less than the mass standard, obtained results are lower than 100%, for products weighing more, the obtained results are greatly  exceeded.
Totalizing

Totalizing

Function adding new mass value to already obtained one. This allows to determine mass content of the mixture, being a composition of number of different consistence components. Totalizing is limited by maximum capacity parameter.
Parts counting

Parts counting

Function using mass measurement for determination of  measured items quantity. Mass of a single item is required for this process. It may be either estimated through weighment or taken from a database. For items counting the following algorithm is used: all items mass / single item mass = quantity. Function operation is supperted by a mechanism of Automatic Correction of Accuracy. This allows to update single item mass in course of the process. To a certain extend Automatic Correction of Accuracy eliminates error which may be a result of different mass values of seemingly alike single elements. For industry solutions items counting may be simultaneously carried out with checkweighing and dosing thus industry solutions feature audio signalling base informing that specified number of items has been weighed. It is possible to apply weighing systems using few platfroms of different MAX capacities and different accuracies.
Peak hold

Peak hold

Function registering the greatest temporary indication occurring in course of the weighing process. It is most often used in medical scales in order to hold the measurement indication.
Statistics

Statistics

Statistiscs function registers and analyses performed measurements. This supplies the user withthe following information: Max and Min standard deviation, average value, variance, range et.
Checkweighing

Checkweighing

Checkweighing function is used for checking whether the measured sample mass is within the predefined threshold values, Low [LO] and Hgh [HI]. The thresholds are given in [g] and [kg] units. Current state of a sample being measured is signalled by means of pictorgams located on a display for laboratory balances, for industrial scales Stackligt System is used. This visual +/- inspection is in operation during segregation, control or packing process of products for which mass has bees determined with a specifaied tolerance, eg. 12860 g 961
Under-pan weighing

Under-pan weighing

The solution enables weighing with use of a stand, which is advisable for loads of non-standard shapes and dimensions and those that generate magnetic field.
GLP Procedures

GLP Procedures

Diagnostic function allowing to objectively document performed measurements. GLP procedures may be either presented in a short report form or extended one.
Animal weighing

Animal weighing

Process of mass determination for a product which may unwillingly reposition within the weighing pan. Mass determination in such cases requires much longer period of time when compared to typical weighing process. It is the user who defines period of time needed for control of measured product mass. The user can thus optimize the function depending on the measured product characteristics.
Density determination

Density determination

Liquid or solid body density function uses the Archimedes principle and it requires a special kit to be applied. The kit when used, replaces a weighing pan. For solids mass of the sample must be determined first in the air, next in the liquid of specified density. For liquids the so called sinker, density of which has been determined, must be measured first in the air, next in the tested liquid. The density determination process is disturbed by air bubbles which may stick either to the measured sample or the sinker. In case of laboratory equipment very light solids may be measured. For industry, solid bodies density may be determined by means of  under-pan weighing. Tested load of significant size may be measured this way.
Dokumentation
Datenblatt
Data Sheet Data Sheet
Data Sheet

Details anzeigen
Details anzeigen
Download
Download

Choose more product:
Details anzeigen Details anzeigen DownloadDownload
Bedienungsanleitungen
Bedienungsanleitungen - Waagenserie R
Bedienungsanleitungen - Waagenserie R
Details anzeigen
Details anzeigen
Download
Download
(2.53 MB)
Instalation manual
Instalation manual
Details anzeigen
Details anzeigen
Download
Download
(0.49 MB)
Start up Guide
Start up Guide
Details anzeigen
Details anzeigen
Download
Download
(11.76 MB)
Konformitätserklärungen
Conformity Declaration
Conformity Declaration
Details anzeigen
Details anzeigen
Download
Download
(0.04 MB)
Publikationen und Broschüren
Laboratory balance cleaning
Laboratory balance cleaning
Details anzeigen
Details anzeigen
Download
Download
(2.52 MB)
RTP Thermal Receipt Printer
RTP Thermal Receipt Printer
Details anzeigen
Details anzeigen
Download
Download
(1.64 MB)
Direkte Kommunikation Waage-PC
Direkte Kommunikation Waage-PC
Details anzeigen
Details anzeigen
Download
Download
(0.32 MB)
Alibi Reader - tutorial
Alibi Reader - tutorial
Details anzeigen
Details anzeigen
Download
Download
(1.47 MB)
Laboratory Balances
Laboratory Balances
Details anzeigen
Details anzeigen
Download
Download
(1.68 MB)
Stainless Steel in RADWAG products. Standard and special applications
Stainless Steel in RADWAG products. Standard and special applications
Details anzeigen
Details anzeigen
Download
Download
(2.23 MB)
Defined Weighing Profiles
Defined Weighing Profiles
Details anzeigen
Details anzeigen
Download
Download
(1.38 MB)
R Series balances
R Series balances
Details anzeigen
Details anzeigen
Download
Download
(4.98 MB)
Software
Drivers

RADWAG USB DRIVER 1.6.2 (1.25 MB)

Zubehör
RADWAG Elektronische Waagen
Torunska 5
26-600 Radom
Polen
Tel.: +48 48 386 60 00
E-mail: export@radwag.com
VAT Nr.: 796-000-03-27
Vimeo Radwag YouTube Radwag Facebook Radwag LinkedIn Radwag
© 2024 RADWAG Elektronische Waagen. Alle Rechte vorbehalten.

×
Change language AlbanianAlbanian
Change language DanishDanish
Change language NederlandseNederlandse
Change language EstonianEstonian
Change language FinnishFinnish
Change language HungarianHungarian
Change language IcelandicIcelandic
Change language KazakhKazakh
Change language LatvianLatvian
Change language LithuanianLithuanian
Change language MacedonianMacedonian
Change language NorwegianNorwegian
Change language PortuguesePortuguese
Change language RomanianRomanian
Change language RussianRussian
Change language SlovakSlovak
Change language SlovenianSlovenian
Change language SwedishSwedish
Change language UkrainianUkrainian
Change language SerbianSerbian
Change language MontenegrinMontenegrin
Change language page on English English
Change language page on Español Español
Change language page on Français Français
Change language page on Italiano Italiano
Change language page on Polski Polski
Change language page on Türkiye Türkiye
Česky
Português (Brasil)
Change website to USA USA
Change language page on 中文 中文
Presentations Presentations Presentations
Subscribe Subscribe Subscribe
Radwag in Facebook Radwag in Facebook Facebook
Radwag in YouTube Radwag in YouTube Youtube
Radwag in Vimeo Radwag in Vimeo Vimeo
Radwag in LinkedIn Radwag in LinkedIn LinkedIn
Webinars Radwag Webinars Radwag Webinars
close
E-Mail
Firma:
Vorname:
I consent to the processing of my personal data for marketing purposes by Radwag Wagi Elektroniczne Witold Lewandowski.
I consent to receive marketing and product-related messages by electronic means from Radwag Wagi Elektroniczne Witold Lewandowski.
I have read the Privacy Policy of RADWAG Wagi Elektroniczne Witold Lewandowski.
lock_openI want to access the files
close
Slide to go back ↩