Analysenwaage AS 110.R2 PLUS

Radwag Elektronische Waagen
Selected language Deutsch

Analysenwaage AS 110.R2 PLUS

Produktcode: WL-104-0175
Modell ändern (9)
done
Max: 110gd: 0,1mg

 ø100mm
expand_more
Max: 60 / 220gd: 0,01 / 0,1mg

 ø90 Gitterwaagschale + ø85 (optional)mm
Max: 62gd: 0,01mg

 ø90 Gitterwaagschale + ø85 (optional)mm
Max: 82 / 220gd: 0,01 / 0,1mg

 ø90 Gitterwaagschale + ø85 (optional)mm
Max: 120gd: 0,01mg

 ø90 Gitterwaagschale + ø85 (optional)mm
Max: 160gd: 0,1mg

 ø100mm
Max: 220gd: 0,1mg

 ø100mm
Max: 310gd: 0,1mg

 ø100mm
Max: 520gd: 0,1mg

 ø100mm
Wägebereich [Max]: 110 g
Ziffernschritt [d]: 0,1 mg

close
Modell ändern:
Analysenwaage AS 60/220.R2 PLUS
Analysenwaage AS 62.R2 PLUS
Analysenwaage AS 82/220.R2 PLUS
Analysenwaage AS 110.R2 PLUS
Analysenwaage AS 120.R2 PLUS
Analysenwaage AS 160.R2 PLUS
Analysenwaage AS 220.R2 PLUS
Analysenwaage AS 310.R2 PLUS
Analysenwaage AS 520.R2 PLUS
zum Vergleich Erweiterte Suche
Beschreibung

Analysenwaage AS 110.R2 PLUS

 
Die Waage der Serie AS R2 PLUS ist eine Standard-Analysenwaage der Linie SYNERGY LAB. Die AS R2 PLUS zeichnet sich durch eine Reihe von modernen Konstruktions- und Systemlösungen aus, die Zuverlässigkeit, Präzision und Messgenauigkeit garantieren und die tägliche Arbeit erleichtern.

 

Ergonomisches mechanisches Design

Die neueste Analysenwaage AS R2 PLUS verfügt über eine geräumige Wägekammer, und die Schiebetüren ermöglichen einen einfachen Zugang zur Waagschale. Der neue Aluminiumsockel ist ein Garant für die Stabilität des Wägesystems.

Das Dual-CLICK-System ermöglicht eine werkzeuglose Montage und Demontage der Wägekammer, und ein spezielles Design der Führungen für die Scheiben (ohne Ränder) erleichtert die Reinigung des Geräts.

Innovative Konstruktionslösungen erhöhen die Haltbarkeit und Zuverlässigkeit der Waage im Langzeitbetrieb.
 
 

Nivelliersystem

Die AS R2 PLUS-Waagen sind standardmäßig mit einer Nivelliervorrichtung an der Vorderseite der Wägekammer ausgestattet, die die Niveauregulierung erleichtert. Die Nivellierung wird durch die reduzierte Anzahl der einstellbaren Auflagepunkte (2 Punkte) vereinfacht und erleichtert.


 
 

Intuitive Bedienung

Die Waagen sind mit einem LCD-Display ausgestattet, das eine klare Darstellung des Wägeergebnisses gewährleistet. Der direkte Zugriff auf Funktionen und Datenbanken ist über die folgenden Tasten möglich:
  • Datenbank – direkter Zugriff auf die Datenbanken
  • Funktion – direkter Zugriff auf die Grundfunktionen
  • F1-F4 – programmierbare Funktionstasten und Menünavigationstasten.
AS R2 PLUS-Analysenwaagen signalisieren über Piktogramme den Arbeitsmodus, den Computeranschluss, den Batteriestatus, sowie die Wäge- und Servicefunktionen. Die Anzahl der angezeigten Wägeeinheiten ist ebenfalls erweitert. Eine eigene Statusleiste ermöglicht die Anzeige zusätzlicher Meldungen, z.B. Produktname oder den Tarawert. Die Echtzeit-Massemessung wird über ein Balkendiagramm dargestellt.

Interne Justierung
Ein modernisiertes internes Justiersystem garantiert genaue Anzeigen, auch unter extrem ungünstigen Bedingungen.


 
 
 
 


Schutz der Daten
Der Zugriff auf wertvolle Informationen ist nach der Protokollierung möglich. Der Administrator kann die Konfiguration des Datenzugriffs jedes Nutzers verwalten.
 

 


ALIBI-Speicher
Die Datensicherheit wird durch den in die AS R2 PLUS-Waagen integrierten ALIBI-Speicher gewährleistet, der die Aufzeichnung von bis zu 100 000 Wägungen ermöglicht. Der ALIBI-Speicher garantiert die Kontinuität der Datenerfassung über einen langen Zeitraum hinweg.
 
 

Datenbanken

Das Informationssystem basiert auf 5 Datenbanken, was es mehreren Benutzern ermöglicht, mit mehreren Produktdatenbanken zu arbeiten. Die gespeicherten Wägeergebnisse können einer weiteren Analyse unterzogen werden.
Die Daten werden in 5 Datenbanken registriert:
  • Betreiber (bis zu 10 Benutzer),
  • Produkte (bis zu 1000 Produkte),
  • Wägungen (bis zu 5000 Wägungen),
  • Taras (bis zu 100 Taras),
  • ALIBI-Speicher (bis zu 100 000 Wägungen).
 

Kommunikationsschnittstellen

Die Funktionalität der AS R2 PLUS-Waagen kann mit den folgenden Kommunikationsschnittstellen erweitert werden: USB-A, USB-B, RS 232, Ethernet, Wi-Fi® (Option).
 
 
Zusatzoption:
Unterflurwägung
Waagen, die nach dem 15.02.2023 gekauft wurden, ermöglichen Unterflurwägung zu einem beliebigen Zeitpunkt nach dem Kauf des Geräts. Alles, was Sie tun müssen, ist, einen speziellen Haken zu erwerben.
 
 
Edelstahl in RADWAG-Produkten
Erfahren Sie mehr über die Verwendung und Pflege von Edelstahlprodukten:
Rostfreier Stahl in RADWAG-Produkten. Standard- und Spezialanwendungen

Wi-Fi® ist eine eingetragene Marke der Wi-Fi Alliance®.
Technische Daten
Wägebereich [Max]

110

 g

Min. Belastung

10

 mg

Ziffernschritt [d]

0,1

 mg

Eichwert [e]

1

 mg

Tarierbereich

-110

 g

Standard Wiederholbarkeit [5% Max]

0,06

 mg

Standard Wiederholbarkeit [Max]

0,08

 mg

Min. Einwaage (USP)

120

 mg

Min. Einwaage (U=1%, k=2)

12

 mg

Garantierte Wiederholbarkeit [5%]

0,09

 mg

Garantierte Wiederholbarkeit [Max]

0,1

 mg

Linearität

±0,2

 mg

Stabilisierungszeit

2

 s

Justierung

intern (automatisch)

 

OIML-Klasse

I

 

Nivelliersystem

manuell

 

Display

LCD (hinterleuchtet)

 

Türen der Wägekammer

manuell

 

Lieferumfang

Waage, Waagschale, Waagschalenabdeckung, Zentrierring, Bodenabdeckung, Netzteil.

 

Waagschale

ø100

 mm

Verpackungsgröße

490×400×520

 mm

Nettogewicht

7,3

 kg

Bruttogewicht

9

 kg

Schutzart

IP 43

 

Schnittstellen

2×RS232¹, 2×USB-A (Zugangsport vorne und hinten), USB-B, Wi-Fi® (optional)

 

Stromversorgung

Adapter: 100 – 240V AC 50/60Hz 0,6A; 12V DC 1,2A
Waage: 12 – 15V DC 0,4A max

 

Maximaler Leistungsaufnahme

3 W

 

Umgebungstemperatur

+10 – +40

 °C

Relative Luftfeuchtigkeit

40% – 80%

 

CE
 Eichung Extra payment
for verification

Wiederholbarkeit wird als Standardabweichung von 10 Wägezyklen ausgedrückt.
Die Stabilisierungszeit ist abhängig von den Umgebungsbedingungen und der Geschwindigkeit bei Auflegen der Last auf der Waagschale; für FAST-Profil definiert.
1 Die als Zubehör erhältlichen Barcode-Scanner arbeiten mit der Waage nur über die RS232-Schnittstelle.

Videos
Einfaches Drucken mit Thermo-Belegdrucker mit Wi-Fi®®
Connecting RADWAG RTP-UEW80 Printer via Wi-Fi® (Tutorial)
AS X2 PLUS Analytical Balance Unpacking and Installation (Tutorial)
RTP - The First Receipt Printer of RADWAG Production!
Complete Solutions for Mass Measurement in Pharma Industry
Laborwaagen der R-Serie
Funktionen
Autotest

Autotest

Diagnostic function aiming at metrological parameters determination (repeatability), the parameters are determined for the actual conditions of use. When speaking of repeatability it may be also used for weighing time optimization. Autotest is operated in an automatic mode thus operator’s time is saved.
Dosing

Dosing

Weighing process for which reference mass has been determined together with tolerance for its determination. Dosing tolerance is given in [%] and it is calculated in relation to the reference value thus being a permissible deviation of this process. This solution is used for weighing powders, liquids and loose materials. Dosing function performance is often supported with bargraph - load indicator. For industrial scales it is possible to use a control systems of dosing process.
Percent Weighing

Percent Weighing

Percent Weighing function is used for comparision of measured products with mass standard. Mass of a mass standard may be a numeric value taken from a database or it may be determined through a measurement process. Each measured product is compared to mass standard, mass of which is presumed as a model 100% ideal mass. For products weighing less than the mass standard, obtained results are lower than 100%, for products weighing more, the obtained results are greatly  exceeded.
Totalizing

Totalizing

Function adding new mass value to already obtained one. This allows to determine mass content of the mixture, being a composition of number of different consistence components. Totalizing is limited by maximum capacity parameter.
Parts counting

Parts counting

Function using mass measurement for determination of  measured items quantity. Mass of a single item is required for this process. It may be either estimated through weighment or taken from a database. For items counting the following algorithm is used: all items mass / single item mass = quantity. Function operation is supperted by a mechanism of Automatic Correction of Accuracy. This allows to update single item mass in course of the process. To a certain extend Automatic Correction of Accuracy eliminates error which may be a result of different mass values of seemingly alike single elements. For industry solutions items counting may be simultaneously carried out with checkweighing and dosing thus industry solutions feature audio signalling base informing that specified number of items has been weighed. It is possible to apply weighing systems using few platfroms of different MAX capacities and different accuracies.
Peak hold

Peak hold

Function registering the greatest temporary indication occurring in course of the weighing process. It is most often used in medical scales in order to hold the measurement indication.
Statistics

Statistics

Statistiscs function registers and analyses performed measurements. This supplies the user withthe following information: Max and Min standard deviation, average value, variance, range et.
Checkweighing

Checkweighing

Checkweighing function is used for checking whether the measured sample mass is within the predefined threshold values, Low [LO] and Hgh [HI]. The thresholds are given in [g] and [kg] units. Current state of a sample being measured is signalled by means of pictorgams located on a display for laboratory balances, for industrial scales Stackligt System is used. This visual +/- inspection is in operation during segregation, control or packing process of products for which mass has bees determined with a specifaied tolerance, eg. 12860 g 961
Under-pan weighing

Under-pan weighing

The solution enables weighing with use of a stand, which is advisable for loads of non-standard shapes and dimensions and those that generate magnetic field.
GLP Procedures

GLP Procedures

Diagnostic function allowing to objectively document performed measurements. GLP procedures may be either presented in a short report form or extended one.
Animal weighing

Animal weighing

Process of mass determination for a product which may unwillingly reposition within the weighing pan. Mass determination in such cases requires much longer period of time when compared to typical weighing process. It is the user who defines period of time needed for control of measured product mass. The user can thus optimize the function depending on the measured product characteristics.
Density determination

Density determination

Liquid or solid body density function uses the Archimedes principle and it requires a special kit to be applied. The kit when used, replaces a weighing pan. For solids mass of the sample must be determined first in the air, next in the liquid of specified density. For liquids the so called sinker, density of which has been determined, must be measured first in the air, next in the tested liquid. The density determination process is disturbed by air bubbles which may stick either to the measured sample or the sinker. In case of laboratory equipment very light solids may be measured. For industry, solid bodies density may be determined by means of  under-pan weighing. Tested load of significant size may be measured this way.
Dokumentation
Datenblatt
Data Sheet Data Sheet
Data Sheet

Details anzeigen
Details anzeigen
Download
Download

Choose more product:
Details anzeigen Details anzeigen DownloadDownload
Bedienungsanleitungen
Bedienungsanleitungen - Waagenserie R
Bedienungsanleitungen - Waagenserie R
Details anzeigen
Details anzeigen
Download
Download
(2.53 MB)
Start up Guide
Start up Guide
Details anzeigen
Details anzeigen
Download
Download
(11.76 MB)
Konformitätserklärungen
Conformity Declaration
Conformity Declaration
Details anzeigen
Details anzeigen
Download
Download
(0.04 MB)
Publikationen und Broschüren
Principles of Metrology
Principles of Metrology
Details anzeigen
Details anzeigen
Download
Download
(0.10 MB)
Laboratory balance cleaning
Laboratory balance cleaning
Details anzeigen
Details anzeigen
Download
Download
(2.52 MB)
RTP Thermal Receipt Printer
RTP Thermal Receipt Printer
Details anzeigen
Details anzeigen
Download
Download
(1.64 MB)
Direkte Kommunikation Waage-PC
Direkte Kommunikation Waage-PC
Details anzeigen
Details anzeigen
Download
Download
(0.32 MB)
AS R2 PLUS Analysenwaage
AS R2 PLUS Analysenwaage
Details anzeigen
Details anzeigen
Download
Download
(4.18 MB)
Lexikon der Grundlegenden Metrologischen Begriffe
Lexikon der Grundlegenden Metrologischen Begriffe
Details anzeigen
Details anzeigen
Download
Download
(7.88 MB)
Alibi Reader - tutorial
Alibi Reader - tutorial
Details anzeigen
Details anzeigen
Download
Download
(1.47 MB)
Laboratory Balances
Laboratory Balances
Details anzeigen
Details anzeigen
Download
Download
(1.68 MB)
Stainless Steel in RADWAG products. Standard and special applications
Stainless Steel in RADWAG products. Standard and special applications
Details anzeigen
Details anzeigen
Download
Download
(2.23 MB)
Metrology in the laboratory 2024
Metrology in the laboratory 2024
Details anzeigen
Details anzeigen
Download
Download
(5.65 MB)
Defined Weighing Profiles
Defined Weighing Profiles
Details anzeigen
Details anzeigen
Download
Download
(1.38 MB)
R Series balances
R Series balances
Details anzeigen
Details anzeigen
Download
Download
(4.98 MB)
Software
Drivers

RADWAG USB DRIVER 1.6.2 (1.25 MB)

Zubehör
Zusätzliche Module

RES Radwag Kommunikationsprotokoll3
Modul der Konformität mit 21 CFR Teil 113

Newsletter

If you wish to receive the latest news about RADWAG products and services, sign up for the newsletter.

More
RADWAG Elektronische Waagen
Torunska 5
26-600 Radom
Polen
Tel.: +48 48 386 60 00
E-mail: export@radwag.com
VAT Nr.: 796-000-03-27
Vimeo Radwag YouTube Radwag Facebook Radwag LinkedIn Radwag
© 2024 RADWAG Elektronische Waagen. Alle Rechte vorbehalten.

×
Change language AlbanianAlbanian
Change language DanishDanish
Change language NederlandseNederlandse
Change language EstonianEstonian
Change language FinnishFinnish
Change language HungarianHungarian
Change language IcelandicIcelandic
Change language KazakhKazakh
Change language LatvianLatvian
Change language LithuanianLithuanian
Change language MacedonianMacedonian
Change language NorwegianNorwegian
Change language PortuguesePortuguese
Change language RomanianRomanian
Change language RussianRussian
Change language SlovakSlovak
Change language SlovenianSlovenian
Change language SwedishSwedish
Change language UkrainianUkrainian
Change language SerbianSerbian
Change language MontenegrinMontenegrin
Change language page on English English
Change language page on Español Español
Change language page on Français Français
Change language page on Italiano Italiano
Change language page on Polski Polski
Change language page on Türkiye Türkiye
Česky
Português (Brasil)
Change website to USA USA
Change language page on 中文 中文
Presentations Presentations Presentations
Subscribe Subscribe Subscribe
Radwag in Facebook Radwag in Facebook Facebook
Radwag in YouTube Radwag in YouTube Youtube
Radwag in Vimeo Radwag in Vimeo Vimeo
Radwag in LinkedIn Radwag in LinkedIn LinkedIn
Webinars Radwag Webinars Radwag Webinars
close
E-Mail
Firma:
Vorname:
I consent to the processing of my personal data for marketing purposes by Radwag Wagi Elektroniczne Witold Lewandowski.
I consent to receive marketing and product-related messages by electronic means from Radwag Wagi Elektroniczne Witold Lewandowski.
I have read the Privacy Policy of RADWAG Wagi Elektroniczne Witold Lewandowski.
lock_openI want to access the files
close
Slide to go back ↩