XA 53.5Y.M.A.P Microbalance

Selected language
Obraz
This image is for reference only.

XA 53.5Y.M.A.P Microbalance

Product code: WL-112-0003
Change the model (5)
done
Max: 53gd: 1µg

 ø26mm
expand_more
Max: 6 / 21gd: 1 / 2µg

 ø26mm
Max: 21gd: 1µg

 ø26mm
Max: 21 / 52gd: 1 / 5µg

 ø26mm
Max: 52gd: 5µg

 ø26mm
Maximum capacity [Max]: 53 g
Readability [d]: 1 µg

close
Change the model:
XA 6/21.5Y.M.A.P Microbalance
XA 21.5Y.M.A.P Microbalance
XA 21/52.5Y.M.A.P Microbalance
XA 52.5Y.M.A.P Microbalance
XA 53.5Y.M.A.P Microbalance
Select all
View
Download
Add to compare Advanced Search
Overview

 

Datasheet
Maximum capacity [Max]

53

 g

Minimum load

0,1

 mg

Readability [d]

1

 µg

Verification unit [e]

1

 mg

Tare range

-53

 g

Standard repeatability [5% Max]

1,5

 µg

Standard repeatability [Max]

6

 µg

Standard minimum weight (USP)

3

 mg

Standard minimum weight (U=1%, k=2)

0,3

 mg

Permissible repeatability [5% Max]

2,4

 µg

Permissible repeatability [Max]

8

 µg

Linearity

±20

 µg

Eccentric load deviation

20

 µg

Sensitivity time drift

1×10⁻⁶/Year×Rt

 

Stabilization time

~ 3,5

 s

Adjustment

internal (automatic)

 

OIML Class

I

 

Leveling system

automatic – Reflex Level System

 

Display

10″ graphic colour touchscreen

 

Weighing chamber doors

automatic

 

Delivery components

Microbalance, weighing pan, weighing pan shield, power supply, automatic pipette calibration adapter: (base, bottom ring, glass vessel, pipette calibration adapter, evaporation ring, weighing pan, glass lid, mechanical closing cover, protecting screw), brush, fabric dust cover.

 

Weighing chamber dimensions

199×170×217

 mm

Capacity

11 ml

 

Weighing pan dimensions

ø26

 mm

Packaging dimensions

750×492×595

 mm

Net weight

14,5

 kg

Gross weight

18,9

 kg

Protection class

IP 43

 

Communication interface

2×USB-A, USB-C, HDMI, Ethernet, Wi-Fi®, Hotspot

 

Power supply

Adapter: 100 – 240V AC 50/60Hz 1A; 15V DC 2,4A
Balance: 12 – 15V DC 1,4A max*

 

Operating temperature

+10 – +40

 °C

Operating temperature change rate

±0,3 °C / 1 h (±1 °C / 8 h)

 

Relative humidity

40% – 80%

 

Relative humidity change rate

±1% / h (±4% / 8 h)

 

CE
Verification Additional fee
for verification
5 years warranty
Repeatability is expressed as a standard deviation from 10 cycles of mass standard weighing.
Stabilization time dependson the ambient conditions and the dynamics of weighing pan loading; specified for FAST profile.
* The power supply can be connected to the socket on the back of the balance housing or to the terminal.
360°
Videos
Precision and Working Comfort – Operating RADWAG Balances in Every Glove!
5Y Functions: Animal Weighing
5Y Functions: Statistics
5Y Functions: DWA®
5Y Balance and Barcode Scanner – Easy Connection
New Menu Language in 5Y Series Balances: Japanese
5Y Functions: Checkweighing
5Y Functions: Dosing
5Y Functions: Formulations
Percentage deviations
5Y Functions: Weighing
5Y Functions: Parts counting
5Y Functions: Proximity Sensors – Touch-Free Control (Tutorial)
5Y Functions: GLP Procedures – Objective Documentation of Measurements (Tutorial)
Weighing Printout Design in Analytical and Precision Balances (Tutorial)
Easy Printing with Wi-Fi® Thermal Receipt Printer by RADWAG.
ELLIPSIS – New Balance by RADWAG
ELLIPSIS – Cutting Edge, Innovative, New
Talk to it. Voice Commands in New ELLIPSIS Balance by RADWAG
310 ELLIPSIS – Scan or Tap to Log In
Remote VPN Support on ELLIPSIS Balances
ELLIPSIS – Unlimited Connections
Connecting RADWAG RTP-UEW80 Printer via Wi-Fi® (Tutorial)
XA 5Y.M Unpacking and Installation (Tutorial)
RTP - The First Receipt Printer of RADWAG Production!
Complete Solutions for Mass Measurement in Pharma Industry
New AS and PS 5Y Balances – Autotest (Tutorial)
Functions
Autotest

Autotest

Diagnostic function aiming at metrological parameters determination (repeatability), the parameters are determined for the actual conditions of use. When speaking of repeatability it may be also used for weighing time optimization. Autotest is operated in an automatic mode thus operator’s time is saved.
Percent Weighing

Percent Weighing

Percent Weighing function is used for comparision of measured products with mass standard. Mass of a mass standard may be a numeric value taken from a database or it may be determined through a measurement process. Each measured product is compared to mass standard, mass of which is presumed as a model 100% ideal mass. For products weighing less than the mass standard, obtained results are lower than 100%, for products weighing more, the obtained results are greatly  exceeded.
Peak hold

Peak hold

Function registering the greatest temporary indication occurring in course of the weighing process. It is most often used in medical scales in order to hold the measurement indication.
Statistics

Statistics

Statistiscs function registers and analyses performed measurements. This supplies the user withthe following information: Max and Min standard deviation, average value, variance, range et.
IR sensors

IR sensors

Programmable function supporting the weighing process through control of the following options: sliding weighing chamber doors, printout, zeroing, tarring etc. Especially appreciated wherever preventing the balance from soiling is important.
GLP Procedures

GLP Procedures

Diagnostic function allowing to objectively document performed measurements. GLP procedures may be either presented in a short report form or extended one.
Pipettes Calibration

Pipettes Calibration

Function verifying correctness of piston pipettes functioning, the verification is performed via gravimetric measurement of the excreted liquid. Pipettes calibration may be either a stand-alone module or it may be operated
Air density correction

Air density correction

Function performing correction of mass measurement indication, wherein the air density is taken into account. It is used in balances with reading unit < 0,01 mg.
Automatic sliding door

Automatic sliding door

Automatic side panes opened via touch-free IR sensors.
Moveable range

Moveable range

Dual range analytical balances can be equipped with much more precise measuring range but only in very limited part of max capacity and only from zero load. A new technology introduced by RADWAG allows for moving this limited range till max capacity of the balance is reached. Such solution has been named as: Moveable range.
Differential weighing

Differential weighing

Differential weighing informs about mass variation a particular sample, wherein the said variation is a result of manufacturing processes.

Differential weighing is often applied in product control process, for which reference product parameters have been specified in order to be used as a source of comparison for the whole series.
Insuchcasestandard deviation is the information which tells about quality and completeness of a final product. For systems based on a feed-back technique such information may be used by control units.
Ambient conditions monitoring

Ambient conditions monitoring

The possibility of cooperation with the THBR 2.0 system
Replaceable unit

Replaceable unit

Replaceable units.
Statistical Quality Control

Statistical Quality Control

Statistical control for determination of basic statistical criteria: maximum, minimum, standard deviation, mean values for each batch, etc.
ALIBI Memory

ALIBI Memory

"ALIBI" memory enables saving and storing up to 100000 measurements.  Measurements are saved automatically upon each pressing of the key. There is no need for any additional operations or changing settings.
The following data related with the measurements is saved: measurement date; measurement time; result (mass); tare value; operator carrying out the measurement (logged in); product name.
The software saves the measurement in a so called loop, i.e. when the measurement no. 100001 is saved, the measurement 1 gets automatically deleted from the memory.
Measurements saved to balance memory cannot be deleted.
You can preview and print out the data saved to the ALIBI database.
Wi-Fi®

Wi-Fi®

Thanks to wireless communication between the computer and a balance, it is possible to use a balance inside a laminar flow hood and a fume cupboard.

Documentation
Data Sheet Data Sheet
Data Sheet

View
View
Download
Download

Choose more product:
View View DownloadDownload
User Manual
User Manual
View
View
Download
Download
(2.36 MB)
User Manual
User Manual
View
View
Download
Download
(1.24 MB)
Software Manual
Software Manual
View
View
Download
Download
(1.23 MB)
User Manual
User Manual
View
View
Download
Download
(13.23 MB)
Start up Guide
Start up Guide
View
View
Download
Download
(4.76 MB)
Software Manual
Software Manual
View
View
Download
Download
(0.95 MB)
Conformity Declarations
Conformity Declarations
View
View
Download
Download
(0.04 MB)
Laboratory balance cleaning
Laboratory balance cleaning
View
View
Download
Download
(2.52 MB)
RTP Thermal Receipt Printer
RTP Thermal Receipt Printer
View
View
Download
Download
(1.64 MB)
Lexicon of Basic Metrological Terms
Lexicon of Basic Metrological Terms
View
View
Download
Download
(6.31 MB)
RFID
RFID
View
View
Download
Download
(0.68 MB)
Hybrid Protective Glass
Hybrid Protective Glass
View
View
Download
Download
(1.86 MB)
Micro Scale Measurement
Micro Scale Measurement
View
View
Download
Download
(2.74 MB)
Laboratory Balances
Laboratory Balances
View
View
Download
Download
(1.68 MB)
Metrology in the laboratory 2024
Metrology in the laboratory 2024
View
View
Download
Download
(5.65 MB)
Weighing systems for calibration  and verification of piston pipettes
Weighing systems for calibration and verification of piston pipettes
View
View
Download
Download
(5.27 MB)
ELLIPSIS 5Y Laboratory Balances
ELLIPSIS 5Y Laboratory Balances
View
View
Download
Download
(33.90 MB)
Accessories
RFID Tags

Accessories

Newsletter

Subscribe to the newsletter if you would like to receive RADWAG news.

View more
Radwag Balances and Scales
Torunska 5
26-600 Radom
Poland
tel.: +48 48 386 60 00
e-mail: export@radwag.com
TIN: PL7960000327
Vimeo Radwag YouTube Radwag Facebook Radwag LinkedIn Radwag
© 2024 RADWAG Balances and Scales. All rights reserved.

Select language

×
Change language AlbanianAlbanian
Change language DanishDanish
Change language NederlandseNederlandse
Change language EstonianEstonian
Change language FinnishFinnish
Change language HungarianHungarian
Change language IcelandicIcelandic
Change language KazakhKazakh
Change language LatvianLatvian
Change language LithuanianLithuanian
Change language MacedonianMacedonian
Change language NorwegianNorwegian
Change language PortuguesePortuguese
Change language RomanianRomanian
Change language RussianRussian
Change language SlovakSlovak
Change language SlovenianSlovenian
Change language SwedishSwedish
Change language UkrainianUkrainian
Change language SerbianSerbian
Change language MontenegrinMontenegrin
Change language page on Deutsch Deutsch
Change language page on English English
Change language page on Español Español
Change language page on Français Français
Change language page on Italiano Italiano
Change language page on Polski Polski
Change language page on Türkiye Türkiye
Česky
Português (Brasil)
Change website to USA USA
Change language page on 中文 中文
Presentations Presentations Presentations
Subscribe Subscribe Subscribe
Radwag in Facebook Radwag in Facebook Facebook
Radwag in YouTube Radwag in YouTube Youtube
Radwag in Vimeo Radwag in Vimeo Vimeo
Radwag in LinkedIn Radwag in LinkedIn LinkedIn
Webinars Radwag Webinars Radwag Webinars
close
E-mail:
Company name:
Name:
I consent to the processing of my personal data for marketing purposes by Radwag Wagi Elektroniczne Witold Lewandowski.
I consent to receive marketing and product-related messages by electronic means from Radwag Wagi Elektroniczne Witold Lewandowski.
I have read the Privacy Policy of RADWAG Wagi Elektroniczne Witold Lewandowski.
lock_openI want to access the files
close
Slide to go back ↩