Terminale di pesata PUE HX5.EX-1

Radwag Bilance e sistemi di pesatura
Selected language Italiano
Obraz
This image is for reference only.

Terminale di pesata PUE HX5.EX-1

Codice prodotto: WX-008-0145
close
Modifica del modello:
Terminale di pesata PUE HX5.EX-2
Terminale di pesata PUE HX5.EX-3
Terminale di pesata PUE HX5.EX-4
Terminale di pesata PUE HX5.EX-1
Select all
Vista
Salva
Caratteristiche generali
PUE HX5.EX terminal is a constructional component of industrial multifunctional load cell scales. It is the most modern RADWAG solution to be used in areas endangered with explosive atmosphere. The HX5.EX is compliant with ATEX directive regulations. The terminal is intended for operation in environment filled with explosive gases and dust, and can be placed in zones: 1/21 and 2/22.
Standard version of the terminal is equipped with 2 serial intrinsically safe RS232 communication interfaces, and with one intrinsically safe RS485 interface. They facilitate communication with equipment predetermined for use in hazardous areas. Possibility to add digital inputs/outputs expands the range of instruments compatible with the terminal by robotic elements compliant with ATEX directive. For more demanding customers, RADWAG has developed IM01.EX module, installed in the safe area, which extends the available connector range by Ethernet, USB, 4-20mA/0-10V analog outputs, Profibus DP and additional digital inputs/outputs. This enables communication between the terminal and external devices such as barcode scanners, printers, external displays, control buttons, light signalling towers, other controlling/signalling devices, systems for automatic process control and superior IT systems.

Models 
There are 4 different models:
  • PUE HX5.EX-1: 2 × RS232, RS485 - standard design,
  • PUE HX5.EX-2: standard design + 4IN/4OUT,
  • PUE HX5.EX-3: standard design + 4IN,
  • PUE HX5.EX-4: standard design + 4OUT.
Mechanical Design
The housing, made of AISI 304 stainless steel, ensures high ingress protection, IP66 / IP68 (up to 1.5 m immersion). The terminal features 5" colour LCD, covered with polycarbonate protecting it against shocks, and a membrane keypad. Ease of operation, clear menu and intuitive information arrangement on the display guarantee comfort of operation. Hermetic intrinsically safe interface connectors are located on the back side of the housing. Stable bracket enables mounting the terminal either on a flat horizontal surface or on the wall. The device tilt can be easily adjusted.

Power Supply
The PUE HX5.EX terminal can be connected to the mains only with a certified intrinsically safe power supply, manufactured by RADWAG:
  • PM01.EX-1 power supply intended for operation in hazardous area:
    • zone 1 and 2 where there is a risk of explosion due to mixture of air with vapour, mist or gas, classified as explosion group IIC, IIB and IIA and as temperature class T1, T2, T3, T4.
    • zone 21 and 22 where there is a risk of explosion due to mixture of air with dust, flammable fibres and volatile fuels, classified as explosion group IIIC, IIIB and IIIA.
  • PM01.EX-2 power supply intended for operation in safe area, equipped with intrinsically safe circuits which may be placed in:
    • zone 1 and 2 where there is a risk of explosion due to mixture of air with vapour, mist or gas, classified as explosion group IIC, IIB and IIA and as temperature class T1, T2, T3, T4.
    • zone 21 and 22 where there is a risk of explosion due to mixture of air with dust, flammable fibres and volatile fuels, classified as explosion group IIIC, IIIB and IIIA.
IM01.EX Communication Module
The terminal’s interface range can be expanded using IM01.EX communication module, connected to the terminal via an intrinsically safe RS485 interface, placed outside the hazardous area.
Models:
  • IM01.EX-1  Standard: 2x RS232, USB,4 I/4 O, Ethernet
  • IM01.EX-2  analog output 4-20mA/0-10V
  • IM01.EX-3  12 I/12 O, digital
  • IM01.EX-4  Profibus DP
  • IM01.EX-5  PROFINET
  • IM01.EX-6  CANopen (available soon)
  • IM01.EX-7  DeviceNet (available soon)
  • IM01.EX-8  RS485
  • IM01.EX: ETHERNET IP (available soon)
Multifunctional Software
Terminal software facilitates processes such as weighing, parts counting, dosing, and percent weighing. Terminal’s information system is based on databases (users, products, weighings, packaging, formulations, customers) and ALIBI memory which guarantees stored data safety. The interfaces enable communication between the terminal and the accessories intended for operation in the hazardous and non-hazardous areas. Accessories: barcode scanners, printers, external displays, control buttons, light signalling towers and other controlling/signalling devices. The terminal can communicate with systems for automatic process control and superior IT systems.
Stainless Steel in RADWAG products
Learn about the use and maintenance of stainless steel products:
Stainless Steel in RADWAG products. Standard and special applications
Specifiche
Classe OIML

III

 

Quantita massima di divisioni gestite dal convertitore

100 000

 

Quantita massima di unita verificate

6000 e

 

Minimum volatge per verification unit

0,4 µV

 

Impedenza della cella al carico minimo

80 Ω

 

Maximum load cell impedance

1200 Ω

 

Incremento massimo del segnale

19,5 mV

 

Connessione di celle di carico

4 or 6 wires + shield

 

Display

5” graphic colour

 

Device dimensions

329×231×120

 mm

Dimensioni del pacco

640×310×220

 mm

Peso netto

7,8

 kg

Peso lordo

10,5

 kg

Punteggio IP

IP 66 / 68

 

Struttura

Stainless steel

 

Certificazione ATEX

II 2G Ex ib IIC T4 Gb (gases)
II 2D Ex ib IIIC T60ºC Db (dusts)

 

Lavorare in zone

1, 2 (gases); 21, 22 (dusts)

 

Interfaccia

2×RS232, RS485

 

Ambiente di lavoro

-10 – +40

 °C

CE
Garanzia 2 anni
bilance con certificazione ATEX
360°
Video
Complete Solutions for Mass Measurement in Pharma Industry
Funzioni
Labelling

Labelling

Marking products with the right symbols contributes to quick and reliable identification. The balance/scale usually transfers product mass or product quantity to the label printer. The transferred value is printed with the following information: bar code, pictogram, content, address etc. In laboratory the labelling is performed in a semi-automatic mode, for industry in an automatic one (dynamic scales).
Plus/Minus Control

Plus/Minus Control

Control of sample's mass carried out with reference to specified MIN and MAX thresholds. The weight is considered to be correct if it is comprised within threshold values. A graphic visualisation of weighing result is displayed in a form of a bar graph.
Percent Weighing

Percent Weighing

Percent Weighing function is used for comparision of measured products with mass standard. Mass of a mass standard may be a numeric value taken from a database or it may be determined through a measurement process. Each measured product is compared to mass standard, mass of which is presumed as a model 100% ideal mass. For products weighing less than the mass standard, obtained results are lower than 100%, for products weighing more, the obtained results are greatly  exceeded.
Parts counting

Parts counting

Function using mass measurement for determination of  measured items quantity. Mass of a single item is required for this process. It may be either estimated through weighment or taken from a database. For items counting the following algorithm is used: all items mass / single item mass = quantity. Function operation is supperted by a mechanism of Automatic Correction of Accuracy. This allows to update single item mass in course of the process. To a certain extend Automatic Correction of Accuracy eliminates error which may be a result of different mass values of seemingly alike single elements. For industry solutions items counting may be simultaneously carried out with checkweighing and dosing thus industry solutions feature audio signalling base informing that specified number of items has been weighed. It is possible to apply weighing systems using few platfroms of different MAX capacities and different accuracies.
Statistics

Statistics

Statistiscs function registers and analyses performed measurements. This supplies the user withthe following information: Max and Min standard deviation, average value, variance, range et.
GLP Procedures

GLP Procedures

Diagnostic function allowing to objectively document performed measurements. GLP procedures may be either presented in a short report form or extended one.
Replaceable unit

Replaceable unit

Replaceable units.
ALIBI Memory

ALIBI Memory

"ALIBI" memory enables saving and storing up to 100000 measurements.  Measurements are saved automatically upon each pressing of the key. There is no need for any additional operations or changing settings.
The following data related with the measurements is saved: measurement date; measurement time; result (mass); tare value; operator carrying out the measurement (logged in); product name.
The software saves the measurement in a so called loop, i.e. when the measurement no. 100001 is saved, the measurement 1 gets automatically deleted from the memory.
Measurements saved to balance memory cannot be deleted.
You can preview and print out the data saved to the ALIBI database.
Documentazione
Data Sheet Data Sheet
Data Sheet

Vista
Vista
Salva
Salva

Choose more product:
Vista Vista SalvaSalva
Manuali - CBCP 02
Manuali - CBCP 02
Vista
Vista
Salva
Salva
(0.25 MB)
Start up Guide
Start up Guide
Vista
Vista
Salva
Salva
(1.57 MB)
Software Manual - Appendices 02
Software Manual - Appendices 02
Vista
Vista
Salva
Salva
(0.99 MB)
User Manual - PUEHX5.EX
User Manual - PUEHX5.EX
Vista
Vista
Salva
Salva
(1.79 MB)
Software Manual - EtherNet/IP communication protocol of PUE HX5.EX
Software Manual - EtherNet/IP communication protocol of PUE HX5.EX
Vista
Vista
Salva
Salva
(2.00 MB)
Software Manual - PUEHX5.EX
Software Manual - PUEHX5.EX
Vista
Vista
Salva
Salva
(3.50 MB)
Software Manual
Software Manual
Vista
Vista
Salva
Salva
(0.93 MB)
User Manual - IM01.EX
User Manual - IM01.EX
Vista
Vista
Salva
Salva
(0.88 MB)
User Manual - PM01.EX
User Manual - PM01.EX
Vista
Vista
Salva
Salva
(0.65 MB)
User Manual - PROFINET communication protocol of PUE HX5.EX
User Manual - PROFINET communication protocol of PUE HX5.EX
Vista
Vista
Salva
Salva
(1.89 MB)
Software Manual - PROFIBUS communication protocol of PUE HX5.EX
Software Manual - PROFIBUS communication protocol of PUE HX5.EX
Vista
Vista
Salva
Salva
(0.88 MB)
Conformity Declaration
Conformity Declaration
Vista
Vista
Salva
Salva
(0.04 MB)
IECEx Quality Assessment
IECEx Quality Assessment
Vista
Vista
Salva
Salva
(0.25 MB)
Notyfication of Quality Assurance
Notyfication of Quality Assurance
Vista
Vista
Salva
Salva
(1.61 MB)
Weighing Solutions for Hazardous Areas
Weighing Solutions for Hazardous Areas
Vista
Vista
Salva
Salva
(13.16 MB)
PUE HX5.EX Weighing Terminal
PUE HX5.EX Weighing Terminal
Vista
Vista
Salva
Salva
(1.70 MB)
Stainless Steel in RADWAG products. Standard and special applications
Stainless Steel in RADWAG products. Standard and special applications
Vista
Vista
Salva
Salva
(2.23 MB)
Terminals and Platforms
Terminals and Platforms
Vista
Vista
Salva
Salva
(3.70 MB)
Software
Drivers

Plik GSD Profibus (1.321 KB)

GSD do Profinet (4.574 KB)

Accessori

Newsletter

Subscribe to the newsletter if you would like to receive RADWAG news.

View more
Radwag bilance e sistemi di pesatura
Torunska 5
26-600 Radom
Poland
tel.: +48 48 386 60 00
e-mail: export@radwag.com
TIN: PL7960000327
Vimeo Radwag YouTube Radwag Facebook Radwag LinkedIn Radwag
© 2024 Radwag bilance e sistemi di pesatura. Diritti riservati

selezionare

×
Change language AlbanianAlbanian
Change language DanishDanish
Change language NederlandseNederlandse
Change language EstonianEstonian
Change language FinnishFinnish
Change language HungarianHungarian
Change language IcelandicIcelandic
Change language KazakhKazakh
Change language LatvianLatvian
Change language LithuanianLithuanian
Change language MacedonianMacedonian
Change language NorwegianNorwegian
Change language PortuguesePortuguese
Change language RomanianRomanian
Change language RussianRussian
Change language SlovakSlovak
Change language SlovenianSlovenian
Change language SwedishSwedish
Change language UkrainianUkrainian
Change language SerbianSerbian
Change language MontenegrinMontenegrin
Change language page on Deutsch Deutsch
Change language page on English English
Change language page on Español Español
Change language page on Français Français
Change language page on Polski Polski
Change language page on Türkiye Türkiye
Česky
Português (Brasil)
Change website to USA USA
Change language page on 中文 中文
Presentations Presentations Presentations
Subscribe Subscribe Subscribe
Radwag in Facebook Radwag in Facebook Facebook
Radwag in YouTube Radwag in YouTube Youtube
Radwag in Vimeo Radwag in Vimeo Vimeo
Radwag in LinkedIn Radwag in LinkedIn LinkedIn
Webinars Radwag Webinars Radwag Webinars
close
E-mail
nome azienda:
Nome:
I consent to the processing of my personal data for marketing purposes by Radwag Wagi Elektroniczne Witold Lewandowski.
I consent to receive marketing and product-related messages by electronic means from Radwag Wagi Elektroniczne Witold Lewandowski.
I have read the Privacy Policy of RADWAG Wagi Elektroniczne Witold Lewandowski.
lock_openI want to access the files
close
Slide to go back ↩