Multi funzione in acciaio inox con rampa di carico HX7.4N.300.H1

Radwag Bilance e sistemi di pesatura
Selected language Italiano
Multi funzione in acciaio inox con rampa di carico HX7.4N.300.H1
This image is for reference only.

Multi funzione in acciaio inox con rampa di carico HX7.4N.300.H1

Codice prodotto: WP-227-0002
Modifica del modello (20)
doneexpand_more
Max: 150kgd: 50g

 840×860mm
Max: 150kgd: 50g

 1100×1200mm
Max: 300kgd: 100g

 1100×1200mm
Max: 300kgd: 100g

 1200×1500mm
Max: 300kgd: 100g

 1500×1500mm
Max: 300 / 600kgd: 100 / 200g

 840×860mm
Max: 300 / 600kgd: 100 / 200g

 1100×1200mm
Max: 300 / 600kgd: 100 / 200g

 1200×1500mm
Max: 300 / 600kgd: 100 / 200g

 1500×1500mm
Max: 600kgd: 200g

 1100×1200mm
Max: 600kgd: 200g

 1200×1500mm
Max: 600kgd: 200g

 1500×1500mm
Max: 600 / 1500kgd: 200 / 500g

 1100×1200mm
Max: 600 / 1500kgd: 200 / 500g

 1200×1500mm
Max: 600 / 1500kgd: 200 / 500g

 1500×1500mm
Max: 600kgd: 200g

 840×860mm
Max: 1500kgd: 500g

 1100×1200mm
Max: 1500kgd: 500g

 1200×1500mm
Max: 1500kgd: 500g

 1500×1500mm
Portata massima [Max]: 300 kg
Divisione [d]: 100 g

close
Modifica del modello:
Multi funzione in acciaio inox con rampa di carico HX7.4N.150.H1
Multi funzione in acciaio inox con rampa di carico HX7.4N.150.H2
Multi funzione in acciaio inox con rampa di carico HX7.4N.300.H2
Multi funzione in acciaio inox con rampa di carico HX7.4N.300.H3
Multi funzione in acciaio inox con rampa di carico HX7.4N.300.H4
Multi funzione in acciaio inox con rampa di carico HX7.4N.300/600.H1
Multi funzione in acciaio inox con rampa di carico HX7.4N.300/600.H2
Multi funzione in acciaio inox con rampa di carico HX7.4N.300/600.H3
Multi funzione in acciaio inox con rampa di carico HX7.4N.300/600.H4
Multi funzione in acciaio inox con rampa di carico HX7.4N.300.H1
Multi funzione in acciaio inox con rampa di carico HX7.4N.600.H2
Multi funzione in acciaio inox con rampa di carico HX7.4N.600.H3
Multi funzione in acciaio inox con rampa di carico HX7.4N.600.H4
Multi funzione in acciaio inox con rampa di carico HX7.4N.600/1500.H2
Multi funzione in acciaio inox con rampa di carico HX7.4N.600/1500.H3
Multi funzione in acciaio inox con rampa di carico HX7.4N.600/1500.H4
Multi funzione in acciaio inox con rampa di carico HX7.4N.600.H1
Multi funzione in acciaio inox con rampa di carico HX7.4N.1500.H2
Multi funzione in acciaio inox con rampa di carico HX7.4N.1500.H3
Multi funzione in acciaio inox con rampa di carico HX7.4N.1500.H4
Select all
Vista
Salva
Aggiungere a confrontare
Caratteristiche generali
The HX7.4N H scale is a device controlled by means of the PUE HX7 indicator, and it has been equipped with a 4-load-cell ramp platform made of stainless steel, AISI 304. This robust design facilitates weighing of heavy loads in humid environment. The ramps enable easy loading and unloading.

Indicator with a colour 7” graphic display and a diode bar graph allow to observe visualisation of a current load mass presented in relation to the scale range or declared minimum and maximum thresholds. This makes the operation significantly easier. At the back of the housing there are hermetic connectors of RS232, RS485, USB and Ethernet communication interfaces, plus digital inputs/outputs and analogue output. This enables cooperation with external devices such as barcode scanners, printers, external displays, control buttons, light signalling towers, other controlling/signalling devices, systems for automatic process control and superior IT systems.

With use of the bracket you can either place the indicator at any flat horizontal surface, or fix it to the wall adjusting the tilt respectively to suit your needs.
The terminal's software allows carrying out processes such as weighing, parts counting, dosing, labelling, formulations and percent weighing. Indicator’s system of information is based on databases (users, products, weighings, packaging, formulations, customers) and ALIBI memory which guarantees stored data safety.
Stainless Steel in RADWAG products
Learn about the use and maintenance of stainless steel products:
Stainless Steel in RADWAG products. Standard and special applications
Specifiche
Portata massima [Max]

300

 kg

Portata minima [Min]

2

 kg

Divisione [d]

100

 g

Intervallo di verifica della bilancia [e]

100

 g

Campo di tara

-300

 kg

Massima leggibilità per bilance non verificate

20

 g

Classe OIML

III

 

Display

7” graphic colour

 

Lunghezza del cavo

3

 m

Dimensione piatto

840×860

 mm

Dimensioni del pacco

1250×950×600

 mm

Peso netto

104,7

 kg

Peso lordo

136,3

 kg

Punteggio IP

IP 68 construction, IP 66 / 68 terminal

 

Tastiera

membrane

 

Costruzione

Stainless steel AISI304

 

Interfaccia

RS232, USB-A, 4IN, 4OUT, Ethernet, Modbus RTU

 

Interfacce opzionali

USB (M12 4P), Ethernet, module RS485, module RS232, module Profibus (Dp SLAVE), PROFINET (RRJ45), EtherNet/IP (RRJ45), 12 IN, 12 OUT, 4-20mA, 0-10V

 

Alimentatore

100 – 240 V AC 50/60 Hz

 

Massimo assorbimento elettrico

25 W

 

Alimentatore opzionale

12 – 24 V DC

 

Ambiente di lavoro

-10 – +40

 °C

Temperatura di stoccaggio

-10 – +50

 °C

Umidità relativa

10% – 80% RH no condensation

 

Indicatore

PUE HX7

 

Numero di pulsanti

22

 

Numero massimo di piattaforme

2

 

CE
Verifica Extra payment
for verification
Garanzia 2 anni
Funzioni
Dosing

Dosing

Weighing process for which reference mass has been determined together with tolerance for its determination. Dosing tolerance is given in [%] and it is calculated in relation to the reference value thus being a permissible deviation of this process. This solution is used for weighing powders, liquids and loose materials. Dosing function performance is often supported with bargraph - load indicator. For industrial scales it is possible to use a control systems of dosing process.
Percent Weighing

Percent Weighing

Percent Weighing function is used for comparision of measured products with mass standard. Mass of a mass standard may be a numeric value taken from a database or it may be determined through a measurement process. Each measured product is compared to mass standard, mass of which is presumed as a model 100% ideal mass. For products weighing less than the mass standard, obtained results are lower than 100%, for products weighing more, the obtained results are greatly  exceeded.
Parts counting

Parts counting

Function using mass measurement for determination of  measured items quantity. Mass of a single item is required for this process. It may be either estimated through weighment or taken from a database. For items counting the following algorithm is used: all items mass / single item mass = quantity. Function operation is supperted by a mechanism of Automatic Correction of Accuracy. This allows to update single item mass in course of the process. To a certain extend Automatic Correction of Accuracy eliminates error which may be a result of different mass values of seemingly alike single elements. For industry solutions items counting may be simultaneously carried out with checkweighing and dosing thus industry solutions feature audio signalling base informing that specified number of items has been weighed. It is possible to apply weighing systems using few platfroms of different MAX capacities and different accuracies.
Formulation

Formulation

Function supporting the mixture making process, wherein the mixture contains various components. Formulation function usually uses the balance/scale database of components. Formulation serves for monitored checkweighing of every single component with a given tolerance. It is enriched with a set of individual settings.
Replaceable unit

Replaceable unit

Replaceable units.
ALIBI Memory

ALIBI Memory

"ALIBI" memory enables saving and storing up to 100000 measurements.  Measurements are saved automatically upon each pressing of the key. There is no need for any additional operations or changing settings.
The following data related with the measurements is saved: measurement date; measurement time; result (mass); tare value; operator carrying out the measurement (logged in); product name.
The software saves the measurement in a so called loop, i.e. when the measurement no. 100001 is saved, the measurement 1 gets automatically deleted from the memory.
Measurements saved to balance memory cannot be deleted.
You can preview and print out the data saved to the ALIBI database.
Documentazione
Data Sheet Data Sheet
Data Sheet

Vista
Vista
Salva
Salva

Choose more product:
Vista Vista SalvaSalva
Manuali - CBCP 02
Manuali - CBCP 02
Vista
Vista
Salva
Salva
(0.25 MB)
User Manual - HX7
User Manual - HX7
Vista
Vista
Salva
Salva
(2.11 MB)
Start up Guide
Start up Guide
Vista
Vista
Salva
Salva
(1.81 MB)
Manuali - PROFINET communication protocol PUE HX7
Manuali - PROFINET communication protocol PUE HX7
Vista
Vista
Salva
Salva
(1.79 MB)
Software Manual - Appendices 02
Software Manual - Appendices 02
Vista
Vista
Salva
Salva
(0.99 MB)
Software Manual - EtherNet/IP communication protocol PUE HX7
Software Manual - EtherNet/IP communication protocol PUE HX7
Vista
Vista
Salva
Salva
(2.02 MB)
Software Manual - PROFIBUS communication protocol PUE HX7
Software Manual - PROFIBUS communication protocol PUE HX7
Vista
Vista
Salva
Salva
(1.22 MB)
Quick start
Quick start
Vista
Vista
Salva
Salva
(2.47 MB)
Software Manual
Software Manual
Vista
Vista
Salva
Salva
(0.93 MB)
Conformity Declaration
Conformity Declaration
Vista
Vista
Salva
Salva
(0.04 MB)
RTP Thermal Receipt Printer
RTP Thermal Receipt Printer
Vista
Vista
Salva
Salva
(1.64 MB)
PUE HX7 Weighing Terminal
PUE HX7 Weighing Terminal
Vista
Vista
Salva
Salva
(1.93 MB)
Stainless Steel in RADWAG products. Standard and special applications
Stainless Steel in RADWAG products. Standard and special applications
Vista
Vista
Salva
Salva
(2.23 MB)
HX7 Multifinctional Industrial Scales
HX7 Multifinctional Industrial Scales
Vista
Vista
Salva
Salva
(14.08 MB)
Software
Drivers

LabVIEW (3.05 MB)

GSD Profibus (5 KB)

EDS EtherNetIP (1.931 KB)

Accessori

Newsletter

Subscribe to the newsletter if you would like to receive RADWAG news.

View more
Radwag bilance e sistemi di pesatura
Torunska 5
26-600 Radom
Poland
tel.: +48 48 386 60 00
e-mail: export@radwag.com
TIN: PL7960000327
Vimeo Radwag YouTube Radwag Facebook Radwag LinkedIn Radwag
© 2024 Radwag bilance e sistemi di pesatura. Diritti riservati

selezionare

×
Change language AlbanianAlbanian
Change language DanishDanish
Change language NederlandseNederlandse
Change language EstonianEstonian
Change language FinnishFinnish
Change language HungarianHungarian
Change language IcelandicIcelandic
Change language KazakhKazakh
Change language LatvianLatvian
Change language LithuanianLithuanian
Change language MacedonianMacedonian
Change language NorwegianNorwegian
Change language PortuguesePortuguese
Change language RomanianRomanian
Change language RussianRussian
Change language SlovakSlovak
Change language SlovenianSlovenian
Change language SwedishSwedish
Change language UkrainianUkrainian
Change language SerbianSerbian
Change language MontenegrinMontenegrin
Change language page on Deutsch Deutsch
Change language page on English English
Change language page on Español Español
Change language page on Français Français
Change language page on Polski Polski
Change language page on Türkiye Türkiye
Česky
Português (Brasil)
Change website to USA USA
Change language page on 中文 中文
Presentations Presentations Presentations
Subscribe Subscribe Subscribe
Radwag in Facebook Radwag in Facebook Facebook
Radwag in YouTube Radwag in YouTube Youtube
Radwag in Vimeo Radwag in Vimeo Vimeo
Radwag in LinkedIn Radwag in LinkedIn LinkedIn
Webinars Radwag Webinars Radwag Webinars
close
E-mail
nome azienda:
Nome:
I consent to the processing of my personal data for marketing purposes by Radwag Wagi Elektroniczne Witold Lewandowski.
I consent to receive marketing and product-related messages by electronic means from Radwag Wagi Elektroniczne Witold Lewandowski.
I have read the Privacy Policy of RADWAG Wagi Elektroniczne Witold Lewandowski.
lock_openI want to access the files
close
Slide to go back ↩