Balance WPY 15/30.C2.R.CPP

Radwag Les Balances Electroniques
Selected language Français
Balance WPY 15/30.C2.R.CPP
This image is for reference only.

Balance WPY 15/30.C2.R.CPP

Code produit: WK-308-1036
Change the model (13)
done
Max: 15 / 30kgd: 5 / 10g

 400×500mm
expand_more
Max: 0,6 / 1,5kgd: 0,2 / 0,5g

 195×195mm
Max: 1,5 / 3kgd: 0,5 / 1g

 195×195mm
Max: 3 / 6kgd: 1 / 2g

 300×300mm
Max: 3 / 6kgd: 1 / 2g

 300×300mm
Max: 3 / 6kgd: 1 / 2g

 195×195mm
Max: 6 / 15kgd: 2 / 5g

 300×300mm
Max: 6 / 15kgd: 2 / 5g

 300×300mm
Max: 15 / 30kgd: 5 / 10g

 400×500mm
Max: 15 / 30kgd: 5 / 10g

 300×300mm
Max: 15 / 30kgd: 5 / 10g

 300×300mm
Max: 30 / 60kgd: 10 / 20g

 400×500mm
Max: 30 / 60kgd: 10 / 20g

 400×500mm
Capacité maximale [Max]: 15 / 30 kg
Précision de lecture: 5 / 10 g

close
Change the model:
Balance WPY 0.6/1.5.D2.CPP
Balance WPY 1,5/3.D2.CPP
Balance WPY 3/6.F1.K.CPP
Balance WPY 3/6.F1.R.CPP
Balance WPY 3/6.D2.CPP
Balance WPY 6/15.F1.K.CPP
Balance WPY 6/15.F1.R.CPP
Balance WPY 15/30.C2.K.CPP
Balance WPY 15/30.C2.R.CPP
Balance WPY 15/30.F1.K.CPP
Balance WPY 15/30.F1.R.CPP
Balance WPY 30/60.C2.K.CPP
Balance WPY 30/60.C2.R.CPP
Select all
Voir
Download
Pour Comparer Recherche avancée
Description
 

Balance WPY pour contrôle statistique

 
Les balances de série WPY/CPP possèdent le module intégré qui réalise le contrôle des produits emballés.
La base de données du module contient la liste des produits et des opérateurs. Le contrôle commencé de niveau de balance est terminé automatiquement après le contrôle du nombre des colis déterminé par le logiciel de la balance selon la quantité des colis dans le lot. Les balances possèdent l’afficheur tactile 5,7’’ qui présente les informations concernant le contrôle courant et son résultat.
 
 
 
 

Les étapes du contrôle:

  • choix de l’opérateur
  • choix du produit
  • commencement du contrôle
  • téléchargement des pesages
  • fin automatique du contrôle après le pesage du nombre déterminé des colis
  • impression du rapport de contrôle
Il y a un rapport final après chaque contrôle qui a été réalisée. Le rapport final comporte toutes les informations indispensables pour le rapport concernant les contrôles des produits emballés. Le rapport final est enregistré automatiquement en mémoire interne de la balance.  Il peut être imprimé à l’aide de l’imprimante connectée à la balance.
 
 
 
 

 

Cette balance est destinée au contrôle métrologique des péemballés donc elle doit être homologuée en Métrologie Légale.
Par conséquent, nous vous recommandons de choisir les balances avec une homologation respective.
 
 
 
Acier inoxydable in RADWAG products
Learn about the use and maintenance of stainless steel products:
Acier inoxydable dans les balances RADWAG
Paramètres Techniques
Capacité maximale [Max]

15 / 30

 kg

Capacité minimale [Min]

100 / 200

 g

Précision de lecture

5 / 10

 g

Étendue de tare

-30

 kg

Classe de précision OIML

III

 

Afficheur

5,7” Écran tactile couleur résistif

 

Dimension du plateau

400×500

 mm

Dimensions de colis

720×620×210

 mm

Interface de Communication

2×RS232, 2×USB-A, Ethernet, 4 IN / 4 OUT (numériques), Wi-Fi®

 

Alimentation

100 – 240 V AC 50/60 Hz

 

Température du travail

-10 – +40

 °C

Humidité relative d'air

10% – 85% RH sans condensation

 

CE
2 ans de garantie
La Légalisation des Balances Automatiques
Le Contrôle des Marchandises Emballées
Films
Solution complète pour la mesure de la masse en pharma
Fonctions
Dosing

Dosing

Weighing process for which reference mass has been determined together with tolerance for its determination. Dosing tolerance is given in [%] and it is calculated in relation to the reference value thus being a permissible deviation of this process. This solution is used for weighing powders, liquids and loose materials. Dosing function performance is often supported with bargraph - load indicator. For industrial scales it is possible to use a control systems of dosing process.
Labelling

Labelling

Marking products with the right symbols contributes to quick and reliable identification. The balance/scale usually transfers product mass or product quantity to the label printer. The transferred value is printed with the following information: bar code, pictogram, content, address etc. In laboratory the labelling is performed in a semi-automatic mode, for industry in an automatic one (dynamic scales).
Plus/Minus Control

Plus/Minus Control

Control of sample's mass carried out with reference to specified MIN and MAX thresholds. The weight is considered to be correct if it is comprised within threshold values. A graphic visualisation of weighing result is displayed in a form of a bar graph.
Percent Weighing

Percent Weighing

Percent Weighing function is used for comparision of measured products with mass standard. Mass of a mass standard may be a numeric value taken from a database or it may be determined through a measurement process. Each measured product is compared to mass standard, mass of which is presumed as a model 100% ideal mass. For products weighing less than the mass standard, obtained results are lower than 100%, for products weighing more, the obtained results are greatly  exceeded.
Totalizing

Totalizing

Function adding new mass value to already obtained one. This allows to determine mass content of the mixture, being a composition of number of different consistence components. Totalizing is limited by maximum capacity parameter.
Parts counting

Parts counting

Function using mass measurement for determination of  measured items quantity. Mass of a single item is required for this process. It may be either estimated through weighment or taken from a database. For items counting the following algorithm is used: all items mass / single item mass = quantity. Function operation is supperted by a mechanism of Automatic Correction of Accuracy. This allows to update single item mass in course of the process. To a certain extend Automatic Correction of Accuracy eliminates error which may be a result of different mass values of seemingly alike single elements. For industry solutions items counting may be simultaneously carried out with checkweighing and dosing thus industry solutions feature audio signalling base informing that specified number of items has been weighed. It is possible to apply weighing systems using few platfroms of different MAX capacities and different accuracies.
Peak hold

Peak hold

Function registering the greatest temporary indication occurring in course of the weighing process. It is most often used in medical scales in order to hold the measurement indication.
Formulation

Formulation

Function supporting the mixture making process, wherein the mixture contains various components. Formulation function usually uses the balance/scale database of components. Formulation serves for monitored checkweighing of every single component with a given tolerance. It is enriched with a set of individual settings.
Statistics

Statistics

Statistiscs function registers and analyses performed measurements. This supplies the user withthe following information: Max and Min standard deviation, average value, variance, range et.
Checkweighing

Checkweighing

Checkweighing function is used for checking whether the measured sample mass is within the predefined threshold values, Low [LO] and Hgh [HI]. The thresholds are given in [g] and [kg] units. Current state of a sample being measured is signalled by means of pictorgams located on a display for laboratory balances, for industrial scales Stackligt System is used. This visual +/- inspection is in operation during segregation, control or packing process of products for which mass has bees determined with a specifaied tolerance, eg. 12860 g 961
IR sensors

IR sensors

Programmable function supporting the weighing process through control of the following options: sliding weighing chamber doors, printout, zeroing, tarring etc. Especially appreciated wherever preventing the balance from soiling is important.
Animal weighing

Animal weighing

Process of mass determination for a product which may unwillingly reposition within the weighing pan. Mass determination in such cases requires much longer period of time when compared to typical weighing process. It is the user who defines period of time needed for control of measured product mass. The user can thus optimize the function depending on the measured product characteristics.
Differential weighing

Differential weighing

Differential weighing informs about mass variation a particular sample, wherein the said variation is a result of manufacturing processes.

Differential weighing is often applied in product control process, for which reference product parameters have been specified in order to be used as a source of comparison for the whole series.
Insuchcasestandard deviation is the information which tells about quality and completeness of a final product. For systems based on a feed-back technique such information may be used by control units.
Packaged Goods Control

Packaged Goods Control

Pre-packaged Goods Control mode enables to collect weighings from RADWAG-designed weighing instruments, carry out control and generate PGC reports. Different types of weighing instruments can be combined into a network. The control can be started on a balance or via computer software. It is automatically finished after a respective quantity of packages is verified.
Collected data allows you to assess quality of produced pre-packaged goods and their conformity with:
- internal quality control system;
- 'Pre-Packaged Goods' regulation of 7th May 2009 (Journal of Laws No 91, item 740), on the requirements concerning quantity inspection of pre-packaged goods control, which inspection is to be carried out by means of random selection of the measurements results and sending those results to pre-packaged goods control procedure.
ALIBI Memory

ALIBI Memory

"ALIBI" memory enables saving and storing up to 100000 measurements.  Measurements are saved automatically upon each pressing of the key. There is no need for any additional operations or changing settings.
The following data related with the measurements is saved: measurement date; measurement time; result (mass); tare value; operator carrying out the measurement (logged in); product name.
The software saves the measurement in a so called loop, i.e. when the measurement no. 100001 is saved, the measurement 1 gets automatically deleted from the memory.
Measurements saved to balance memory cannot be deleted.
You can preview and print out the data saved to the ALIBI database.
Documentation
Cartes de produits
Data Sheet Data Sheet
Data Sheet

Voir
Voir
Download
Download

Choose more product:
Voir Voir DownloadDownload
Modes d'emploi
User Manual - WPY Multifunctional Scale
User Manual - WPY Multifunctional Scale
Voir
Voir
Download
Download
(1.68 MB)
Software Manual - CBCP 03
Software Manual - CBCP 03
Voir
Voir
Download
Download
(0.23 MB)
Start up Guide
Start up Guide
Voir
Voir
Download
Download
(1.26 MB)
Quick start
Quick start
Voir
Voir
Download
Download
(2.47 MB)
Software Manual - Appendices 01
Software Manual - Appendices 01
Voir
Voir
Download
Download
(1.81 MB)
Software Manual - PUE 7.1
Software Manual - PUE 7.1
Voir
Voir
Download
Download
(6.55 MB)
Déclarations de conformité
Conformity Declarations
Conformity Declarations
Voir
Voir
Download
Download
(0.04 MB)
Publications et brochures
RTP Thermal Receipt Printer
RTP Thermal Receipt Printer
Voir
Voir
Download
Download
(1.64 MB)
Systeme THBR 2.0
Systeme THBR 2.0
Voir
Voir
Download
Download
(5.24 MB)
Acier inoxydable dans les balances RADWAG
Acier inoxydable dans les balances RADWAG
Voir
Voir
Download
Download
(2.27 MB)
Terminal de Balance PUE 7.1
Terminal de Balance PUE 7.1
Voir
Voir
Download
Download
(0.31 MB)
Accessoires
R-LAB

Accessoires

Modules additionnels

Audit Trail3
RES Protocole de communication Radwag3
Workflow module3
RDA (RADWAG Data Access)3

Newsletter

Inscrivez-vous à la Newsletter de RADWAG pour tout savoir sur nos nouveautés.

Voir plus
Radwag Balances Électroniques
Torunska 5
26-600 Radom
Poland
tel.: +48 48 386 60 00
e-mail: export@radwag.com
TIN: PL7960000327
Vimeo Radwag YouTube Radwag Facebook Radwag LinkedIn Radwag
© 2024 RADWAG Balances Électroniques. Tous les droits sont réservés.

Wybierz język

×
Change language AlbanianAlbanian
Change language DanishDanish
Change language NederlandseNederlandse
Change language EstonianEstonian
Change language FinnishFinnish
Change language HungarianHungarian
Change language IcelandicIcelandic
Change language KazakhKazakh
Change language LatvianLatvian
Change language LithuanianLithuanian
Change language MacedonianMacedonian
Change language NorwegianNorwegian
Change language PortuguesePortuguese
Change language RomanianRomanian
Change language RussianRussian
Change language SlovakSlovak
Change language SlovenianSlovenian
Change language SwedishSwedish
Change language UkrainianUkrainian
Change language SerbianSerbian
Change language MontenegrinMontenegrin
Change language page on Deutsch Deutsch
Change language page on English English
Change language page on Español Español
Change language page on Italiano Italiano
Change language page on Polski Polski
Change language page on Türkiye Türkiye
Česky
Português (Brasil)
Change website to USA USA
Change language page on 中文 中文
Presentations Presentations Presentations
Subscribe Subscribe Subscribe
Radwag in Facebook Radwag in Facebook Facebook
Radwag in YouTube Radwag in YouTube Youtube
Radwag in Vimeo Radwag in Vimeo Vimeo
Radwag in LinkedIn Radwag in LinkedIn LinkedIn
Webinars Radwag Webinars Radwag Webinars
close
E-mail:
Nom de l’entreprise :
Prénom:
I consent to the processing of my personal data for marketing purposes by Radwag Wagi Elektroniczne Witold Lewandowski.
I consent to receive marketing and product-related messages by electronic means from Radwag Wagi Elektroniczne Witold Lewandowski.
I have read the Privacy Policy of RADWAG Wagi Elektroniczne Witold Lewandowski.
lock_openI want to access the files
close
Slide to go back ↩
close