done
Max: 750gd: 0,01g

 128×128mm
expand_more
Max: 2100gd: 0,1g

 195×195mm
Max: 4500gd: 0,1g

 195×195mm
Max: 6100gd: 0,1g

 195×195mm
Max: 8100gd: 0,1g

 195×195mm
Capacité maximale [Max]: 750 g
Précision de lecture: 0,01 g

close
Change the model:
Balance de précision PS 750.5Y.CPP
Balance de précision PS 2100.5Y.M.CPP
Balance de précision PS 4500.5Y.M.CPP
Balance de précision PS 6100.5Y.M.CPP
Balance de précision PS 8100.5Y.M.CPP
Select all
Voir
Download
Pour Comparer Recherche avancée
Description

Balance de précision PS 750.5Y.CPP pour contrôle statistique

 
Les balances de série PS 5Y.CPP possèdent le module intégré qui réalise le contrôle des produits emballés. La base de données du module contient la liste des produits et des opérateurs. Le contrôle commencé de niveau de balance est terminé automatiquement après le contrôle du nombre des colis déterminé par le logiciel de la balance selon la quantité des colis dans le lot. Les balances possèdent l’afficheur tactile 10’’ qui présente les informations concernant le contrôle courant et son résultat.
 
 
 

Les étapes du contrôle:

Il y a un rapport final après chaque contrôle qui a été réalisée. Le rapport final comporte toutes les informations indispensables pour le rapport concernant les contrôles des produits emballés. Le rapport final est enregistré automatiquement en mémoire interne de la balance.  Il peut être imprimé à l’aide de l’imprimante connectée à la balance.
  • choix de l’opérateur
  • choix du produit
  • sélection ou vérification de la TARE
  • téléchargement des pesages
  • fin automatique du contrôle après le pesage du nombre déterminé des colis
  • sauvegarder un rapport ou l'imprimer.

     
 
 
Cette balance est destinée au contrôle métrologique des péemballés donc elle doit être homologuée en Métrologie Légale.
Par conséquent, nous vous recommandons de choisir les balances avec une homologation respective.
 
 
 

Digital Weighing Auditor

s’assure que votre balance est prête à fonctionner. Il permettra une compensation en temps réel de la flottabilité de l’air. De plus, il informera de la nécessité d’effectuer un examen du solde ou un audit périodique de l’exactitude et de la sensibilité du solde.
 
 
 
 

Écran 10 pouces

L’écran plus grand – 10’’ – signifie plus d’informations en un seul endroit. Sur le nouveau terminal ELLIPSIS, vous pouvez même voir 3 écrans, des widgets, des graphiques, des statuts, des notes et un historique de mesure pratique. De plus, les balances de cette série sont équipées d’un certain nombre d’interfaces de communication: 2 x USB-A, USB-C, HDMI, Ethernet et Wi-Fi®.
 
 
 
 

Authentification des utilisateurs sans compromis

Pour la première fois dans l’histoire, la balance vérifiera l’utilisateur à l’aide d’un mot de passe, d’une carte RFID, d’un lecteur d’empreintes digitalesd’un moteur de reconnaissance faciale ou de toute combinaison de ceux-ci. Grâce à ces options avancées, notre balance offre non seulement le plus haut niveau de sécurité, mais également la commodité et l’adaptation aux exigences spécifiques de chaque utilisateur.
 
 
 

Ambient Light – un moyen de communication innovant entre la balance et l’utilisateur

La couleur de surbrillance vous informe sur l’état, les résultats du processus, les procédures ou les alertes.
 
 
 
 
 
 

Hotspot

Utilisez la balance sur n’importe quel dispositif connecté. Il peut s’agir d’un smartphone, d’une tablette ou d’un ordinateur. Hotspot permet le fonctionnement à distance de la balance lorsqu’il n’y a pas d’accès au terminal ou de la place dans la hotte de laboratoire, ainsi que dans d’autres situations qui rendent le travail difficile.
 
 
 

RFID

ELLIPSIS fonctionne avec des étiquettes RFID* qui peuvent être utilisées pour marquer vos produits ou ingrédients de recette dans la base de données. De plus, elles peuvent être utilisées pour identifier l’utilisateur. Il s’agit d’une solution qui combine des méthodes d’identification modernes avec des solutions pratiques pour un usage quotidien.
 
 
 

Live Note – notez vos conclusions

C’est la première fois que vous ajoutez une note vocale à une série de mesures ou à un rapport de procédure. Si vous préférez l’écrire, la balance vous permet d’ajouter une note textuelle. Live Note de la série 5Y est une solution qui élève le niveau de documentation des résultats de mesure, permettant une meilleure gestion des informations et augmentant le confort de travail.
 
 
 

Handy Library

C’est là que vous verrez une série de mesures récentes ou un rapport prêt pour la signature numérique conformément à 21 CFR Part 11.
 
 
 

Widget

Préparé pour afficher ce dont vous avez le plus besoin en ce moment.
 
 
 

Smart Min Weight

La balance affiche des informations indiquant si la valeur de masse que vous souhaitez peser est inférieure ou supérieure au seuil de pesée minimum.
 
 
 

21 CFR Partie 11

Vous travaillez dans l’industrie pharmaceutique ? Avez-vous besoin d’une signature numérique ?
 
Nous proposons une balance de laboratoire qui, en tant que dispositif autonome, répond aux exigences de 21 CFR Partie 11/ EU BPL Annex 11.
 
 Sécurité totale des données
 Signatures électroniques
 Validations
 Dossiers électroniques
 Pistes d’audit
 
 
 

Le Modbus TCP/IP

est un de protocoles plus populaires dans le domaine des systèmes de communication industrielle automatisée. Incorporé aux balances 5Y et CY10, en raison de sa capacité à mettre en réseau divers dispositifs, le protocole facilite le travail à des intégrateurs.
 
Le protocole Modbus échange des informations en utilisant un mécanisme de requête-réponse entre un automate programmable industriel API (PLC) qui est un maître et la balances qui est un esclave. Dans les balances 5Y et C10, le protocole Modbus TCP/IP permet, entre autres, les fonctions de lecture de masse, zérotage et tarage de la balance, ainsi que de configuration de la tare et des seuils MIN et MAX.

 
 
 
 

Réglage en deux points

Le réglage, qui s’effectue en deux points de mesure au lieu d’un, augmente la précision de la mesure sur toute la plage de pesée. Qu’est-ce que cela signifie pour vous? Mesure plus précise.
 
 
 
 
Pesage sous la balance
Les balances achetées après le 15 février 2023 permettront le pesage sous la balance à tout moment après l'achat du dispositif. Achetez simplement un crochet dédié.
 
 
* RFID ISO/IEC 14443 Type A, 13,56 MHz
 
 
Acier inoxydable in RADWAG products
Learn about the use and maintenance of stainless steel products:
Acier inoxydable dans les balances RADWAG

Wi-Fi® est une marque déposée de Wi-Fi Alliance®.
Paramètres Techniques
Capacité maximale [Max]

750

 g

Capacité minimale [Min]

0,5

 g

Précision de lecture

0,01

 g

Échelon de légalisation [e]

0,01

 g

Étendue de tare

-750

 g

Répétabilité standard [5% Max]

0,0005

 g

Répétabilité standard [Max]

0,0015

 g

Poids minimal d’echantillon standard (USP)

1

 g

Poids minimal d’echantillon standard (U=1%, k=2)

0,1

 g

Linéarité

±0,003

 g

Temps de stabilisation

2

 s

Ajustage

interne (automatique)

 

Classe de précision OIML

II

 

Système de nivellement

semi-automatique – LevelSENSING

 

Afficheur

10″ graphique couleurs écran tactile

 

Élément du kit

Balance, plateau, couvercle de plateau, vis de mise à la terre ×1, vis ×3, housse, adaptateur secteur

 

Dimension du plateau

128×128

 mm

Dimensions de colis

600×400×550

 mm

Masse nette

3,9

 kg

Masse brute

5

 kg

Degré de protection

IP 43

 

Bases de données

7

 

Desservice sans touche

2 senseurs infrarouge

 

Interface de Communication

2×USB-A, USB-C, HDMI, Ethernet, Wi-Fi®, Hotspot

 

Alimentation

Adapter: 100 – 240V AC 50/60Hz 1A; 15V DC 2,4A
Balance: 12 – 15V DC 1,6A max; 10–19W*

 

Température du travail

+10 – +40

 °C

Monitorage des conditions environnementales (option)

THBR 2.0 System, THBR BOX, THB P, THB W, THB S

 

Humidité relative d'air

40% – 80%

 

CE
Légalisation Extra payment
for verification
Répétabilité exprimée comme un écart standardisé de 10 placements de chargé.
Temps de stabilisation dépend de conditions externes et de la dynamique du placement d’un poids sur le plateau; déterminé pour le profil FAST
1 Les scanners de codes-barres disponibles en accessoire coopèrent avec la balance en utilisant uniquement l’interface USB.
Films
Precision and Working Comfort – Operating RADWAG Balances in Every Glove!
5Y Functions: Statistics
New Menu Language in 5Y Series Balances: Japanese
Fonctions
Autotest

Autotest

Diagnostic function aiming at metrological parameters determination (repeatability), the parameters are determined for the actual conditions of use. When speaking of repeatability it may be also used for weighing time optimization. Autotest is operated in an automatic mode thus operator’s time is saved.
Dosing

Dosing

Weighing process for which reference mass has been determined together with tolerance for its determination. Dosing tolerance is given in [%] and it is calculated in relation to the reference value thus being a permissible deviation of this process. This solution is used for weighing powders, liquids and loose materials. Dosing function performance is often supported with bargraph - load indicator. For industrial scales it is possible to use a control systems of dosing process.
Percent Weighing

Percent Weighing

Percent Weighing function is used for comparision of measured products with mass standard. Mass of a mass standard may be a numeric value taken from a database or it may be determined through a measurement process. Each measured product is compared to mass standard, mass of which is presumed as a model 100% ideal mass. For products weighing less than the mass standard, obtained results are lower than 100%, for products weighing more, the obtained results are greatly  exceeded.
Parts counting

Parts counting

Function using mass measurement for determination of  measured items quantity. Mass of a single item is required for this process. It may be either estimated through weighment or taken from a database. For items counting the following algorithm is used: all items mass / single item mass = quantity. Function operation is supperted by a mechanism of Automatic Correction of Accuracy. This allows to update single item mass in course of the process. To a certain extend Automatic Correction of Accuracy eliminates error which may be a result of different mass values of seemingly alike single elements. For industry solutions items counting may be simultaneously carried out with checkweighing and dosing thus industry solutions feature audio signalling base informing that specified number of items has been weighed. It is possible to apply weighing systems using few platfroms of different MAX capacities and different accuracies.
Peak hold

Peak hold

Function registering the greatest temporary indication occurring in course of the weighing process. It is most often used in medical scales in order to hold the measurement indication.
Formulation

Formulation

Function supporting the mixture making process, wherein the mixture contains various components. Formulation function usually uses the balance/scale database of components. Formulation serves for monitored checkweighing of every single component with a given tolerance. It is enriched with a set of individual settings.
Statistics

Statistics

Statistiscs function registers and analyses performed measurements. This supplies the user withthe following information: Max and Min standard deviation, average value, variance, range et.
Checkweighing

Checkweighing

Checkweighing function is used for checking whether the measured sample mass is within the predefined threshold values, Low [LO] and Hgh [HI]. The thresholds are given in [g] and [kg] units. Current state of a sample being measured is signalled by means of pictorgams located on a display for laboratory balances, for industrial scales Stackligt System is used. This visual +/- inspection is in operation during segregation, control or packing process of products for which mass has bees determined with a specifaied tolerance, eg. 12860 g 961
IR sensors

IR sensors

Programmable function supporting the weighing process through control of the following options: sliding weighing chamber doors, printout, zeroing, tarring etc. Especially appreciated wherever preventing the balance from soiling is important.
Under-pan weighing

Under-pan weighing

The solution enables weighing with use of a stand, which is advisable for loads of non-standard shapes and dimensions and those that generate magnetic field.
GLP Procedures

GLP Procedures

Diagnostic function allowing to objectively document performed measurements. GLP procedures may be either presented in a short report form or extended one.
Animal weighing

Animal weighing

Process of mass determination for a product which may unwillingly reposition within the weighing pan. Mass determination in such cases requires much longer period of time when compared to typical weighing process. It is the user who defines period of time needed for control of measured product mass. The user can thus optimize the function depending on the measured product characteristics.
Pipettes Calibration

Pipettes Calibration

Function verifying correctness of piston pipettes functioning, the verification is performed via gravimetric measurement of the excreted liquid. Pipettes calibration may be either a stand-alone module or it may be operated
Air density correction

Air density correction

Function performing correction of mass measurement indication, wherein the air density is taken into account. It is used in balances with reading unit < 0,01 mg.
Density determination

Density determination

Liquid or solid body density function uses the Archimedes principle and it requires a special kit to be applied. The kit when used, replaces a weighing pan. For solids mass of the sample must be determined first in the air, next in the liquid of specified density. For liquids the so called sinker, density of which has been determined, must be measured first in the air, next in the tested liquid. The density determination process is disturbed by air bubbles which may stick either to the measured sample or the sinker. In case of laboratory equipment very light solids may be measured. For industry, solid bodies density may be determined by means of  under-pan weighing. Tested load of significant size may be measured this way.
Differential weighing

Differential weighing

Differential weighing informs about mass variation a particular sample, wherein the said variation is a result of manufacturing processes.

Differential weighing is often applied in product control process, for which reference product parameters have been specified in order to be used as a source of comparison for the whole series.
Insuchcasestandard deviation is the information which tells about quality and completeness of a final product. For systems based on a feed-back technique such information may be used by control units.
Ambient conditions monitoring

Ambient conditions monitoring

The possibility of cooperation with the THBR 2.0 system
Statistical Quality Control

Statistical Quality Control

Statistical control for determination of basic statistical criteria: maximum, minimum, standard deviation, mean values for each batch, etc.
Packaged Goods Control

Packaged Goods Control

Pre-packaged Goods Control mode enables to collect weighings from RADWAG-designed weighing instruments, carry out control and generate PGC reports. Different types of weighing instruments can be combined into a network. The control can be started on a balance or via computer software. It is automatically finished after a respective quantity of packages is verified.
Collected data allows you to assess quality of produced pre-packaged goods and their conformity with:
- internal quality control system;
- 'Pre-Packaged Goods' regulation of 7th May 2009 (Journal of Laws No 91, item 740), on the requirements concerning quantity inspection of pre-packaged goods control, which inspection is to be carried out by means of random selection of the measurements results and sending those results to pre-packaged goods control procedure.
ALIBI Memory

ALIBI Memory

"ALIBI" memory enables saving and storing up to 100000 measurements.  Measurements are saved automatically upon each pressing of the key. There is no need for any additional operations or changing settings.
The following data related with the measurements is saved: measurement date; measurement time; result (mass); tare value; operator carrying out the measurement (logged in); product name.
The software saves the measurement in a so called loop, i.e. when the measurement no. 100001 is saved, the measurement 1 gets automatically deleted from the memory.
Measurements saved to balance memory cannot be deleted.
You can preview and print out the data saved to the ALIBI database.
Wi-Fi®

Wi-Fi®

Thanks to wireless communication between the computer and a balance, it is possible to use a balance inside a laminar flow hood and a fume cupboard.

Documentation
Cartes de produits
Data Sheet Data Sheet
Data Sheet

Voir
Voir
Download
Download

Choose more product:
Voir Voir DownloadDownload
Modes d'emploi
User Manual
User Manual
Voir
Voir
Download
Download
(2.36 MB)
Software Manual
Software Manual
Voir
Voir
Download
Download
(1.23 MB)
User Manual
User Manual
Voir
Voir
Download
Download
(13.23 MB)
Start up Guide
Start up Guide
Voir
Voir
Download
Download
(2.94 MB)
Software Manual
Software Manual
Voir
Voir
Download
Download
(0.95 MB)
Déclarations de conformité
Conformity Declarations
Conformity Declarations
Voir
Voir
Download
Download
(0.12 MB)
Publications et brochures
Laboratory balance cleaning
Laboratory balance cleaning
Voir
Voir
Download
Download
(2.52 MB)
RTP Thermal Receipt Printer
RTP Thermal Receipt Printer
Voir
Voir
Download
Download
(1.64 MB)
Cimmunication Directe Balance Ordinateur Sans Application
Cimmunication Directe Balance Ordinateur Sans Application
Voir
Voir
Download
Download
(0.30 MB)
RFID
RFID
Voir
Voir
Download
Download
(0.68 MB)
Laboratory Balances
Laboratory Balances
Voir
Voir
Download
Download
(1.68 MB)
Acier inoxydable dans les balances RADWAG
Acier inoxydable dans les balances RADWAG
Voir
Voir
Download
Download
(2.27 MB)
Profils Definis de Pesage
Profils Definis de Pesage
Voir
Voir
Download
Download
(1.63 MB)
ELLIPSIS Balances de laboratoire série 5Y
ELLIPSIS Balances de laboratoire série 5Y
Voir
Voir
Download
Download
(29.83 MB)
Software
Drivers

RADWAG USB DRIVER 1.6.2 (1.25 MB)

Accessoires
R-LAB

Accessoires

Modules additionnels

RES Protocole de communication Radwag3
Module de conformité à 21 CFR partie 113

Newsletter

Inscrivez-vous à la Newsletter de RADWAG pour tout savoir sur nos nouveautés.

Voir plus
Radwag Balances Électroniques
Torunska 5
26-600 Radom
Poland
tel.: +48 48 386 60 00
e-mail: export@radwag.com
TIN: PL7960000327
Vimeo Radwag YouTube Radwag Facebook Radwag LinkedIn Radwag
© 2024 RADWAG Balances Électroniques. Tous les droits sont réservés.

Wybierz język

×
Change language AlbanianAlbanian
Change language DanishDanish
Change language NederlandseNederlandse
Change language EstonianEstonian
Change language FinnishFinnish
Change language HungarianHungarian
Change language IcelandicIcelandic
Change language KazakhKazakh
Change language LatvianLatvian
Change language LithuanianLithuanian
Change language MacedonianMacedonian
Change language NorwegianNorwegian
Change language PortuguesePortuguese
Change language RomanianRomanian
Change language RussianRussian
Change language SlovakSlovak
Change language SlovenianSlovenian
Change language SwedishSwedish
Change language UkrainianUkrainian
Change language SerbianSerbian
Change language MontenegrinMontenegrin
Change language page on Deutsch Deutsch
Change language page on English English
Change language page on Español Español
Change language page on Italiano Italiano
Change language page on Polski Polski
Change language page on Türkiye Türkiye
Česky
Português (Brasil)
Change website to USA USA
Change language page on 中文 中文
Presentations Presentations Presentations
Subscribe Subscribe Subscribe
Radwag in Facebook Radwag in Facebook Facebook
Radwag in YouTube Radwag in YouTube Youtube
Radwag in Vimeo Radwag in Vimeo Vimeo
Radwag in LinkedIn Radwag in LinkedIn LinkedIn
Webinars Radwag Webinars Radwag Webinars
close
E-mail:
Nom de l’entreprise :
Prénom:
I consent to the processing of my personal data for marketing purposes by Radwag Wagi Elektroniczne Witold Lewandowski.
I consent to receive marketing and product-related messages by electronic means from Radwag Wagi Elektroniczne Witold Lewandowski.
I have read the Privacy Policy of RADWAG Wagi Elektroniczne Witold Lewandowski.
lock_openI want to access the files
close
Slide to go back ↩
close