Báscula de plataforma C315.4.1500.C9

Radwag Balanzas Electrónicas
Selected language Español
Báscula de plataforma C315.4.1500.C9
This image is for reference only.

Báscula de plataforma C315.4.1500.C9

Código de producto: WP-230-0017
Change the model (21)
done
Max: 1500kgd: 0,5kg

 1500×1500mm
expand_more
Max: 60kgd: 0,02kg

 800×800mm
Max: 60kgd: 0,02kg

 1000×1000mm
Max: 150kgd: 0,05kg

 800×800mm
Max: 150kgd: 0,05kg

 1000×1000mm
Max: 300kgd: 0,1kg

 1000×1000mm
Max: 300kgd: 0,1kg

 1200×1200mm
Max: 300kgd: 0,1kg

 800×800mm
Max: 600kgd: 0,2kg

 1000×1000mm
Max: 600kgd: 0,2kg

 1200×1200mm
Max: 600kgd: 0,2kg

 1200×1500mm
Max: 600kgd: 0,2kg

 1500×1500mm
Max: 600kgd: 0,2kg

 800×800mm
Max: 1500kgd: 0,5kg

 800×800mm
Max: 1500kgd: 0,5kg

 1000×1000mm
Max: 1500kgd: 0,5kg

 1200×1200mm
Max: 1500kgd: 0,5kg

 1200×1500mm
Max: 3000kgd: 1kg

 1200×1200mm
Max: 3000kgd: 1kg

 1200×1500mm
Max: 3000kgd: 1kg

 1500×1500mm
Max: 6000kgd: 2kg

 1500×1500mm
Maxima capacidad [Max]: 1500 kg
Legibilidad [d]: 0,5 kg

close
Change the model:
Báscula de plataforma C315.4.60.C6
Báscula de plataforma C315.4.60.C7
Báscula de plataforma C315.4.150.C6
Báscula de plataforma C315.4.150.C7
Báscula de plataforma C315.4.300.C7
Báscula de plataforma C315.4.300.C8
Báscula de plataforma C315.4.300.C6
Báscula de plataforma C315.4.600.C7
Báscula de plataforma C315.4.600.C8
Báscula de plataforma C315.4.600.C8/9
Báscula de plataforma C315.4.600.C9
Báscula de plataforma C315.4.600.C6
Báscula de plataforma C315.4.1500.C6
Báscula de plataforma C315.4.1500.C7
Báscula de plataforma C315.4.1500.C8
Báscula de plataforma C315.4.1500.C8/9
Báscula de plataforma C315.4.1500.C9
Báscula de plataforma C315.4.3000.C8
Báscula de plataforma C315.4.3000.C8/9
Báscula de plataforma C315.4.3000.C9
Báscula de plataforma C315.4.6000.C9
Select all
Ver
Guardar
Para comparar Búsqueda avanzada
Descripción

Báscula de plataforma C315.4.1500.C9

 
Medida de masa con el uso del sistema de 4 sensores garantiza la exactitud de pesajes en toda la superficie de la plataforma.
 
 

La construcción

de balanza fue acabada en acero revestido en polvo. El equipo cuenta con el terminal PUE C315 con pantalla LCD retroiluminada conectada con la plataforma por cable de 3 m de longitud con la posibilidad colgar sobre una pared.
 
 
 
Stainless Steel in RADWAG products
Learn about the use and maintenance of stainless steel products:
Stainless Steel in RADWAG products. Standard and special applications
Datos tecnicos
Maxima capacidad [Max]

1500

 kg

Minima capacidad

10

 kg

Legibilidad [d]

0,5

 kg

Rango de tara

-1500

 kg

Legibilidad máxima para las balanzas no verificadas

100

 g

Clase OIML

III

 

Pantalla

LCD (con retroiluminación)

 

Longitud del cable

3

 m

Dimensión de platillo

1500×1500

 mm

Altura de plataforma de pesaje

120 ± 10

 mm

Dimensiones de embalaje

1600×1600×500

 mm

Masa de balanza con indicador

160

 kg

Grado de protección

IP 65 construcción, IP 43 medidor

 

Conectividad

RS232

 

Interfaces opcionales

RS232

 

Alimentacion

100 – 240 V AC 50/60 Hz + bateria

 

Consumo máximo de potencia

5 W

 

Horas de trabajo con baterias

max 8h

 

Temperatura de trabajo

-10 – +40

 °C

Humedad relativa de aire

10% – 85% RH sin condensación

 

2 año de garantía
Legalización Extra payment
for verification
CE
Vídeos
Complete Solutions for Mass Measurement in Pharma Industry
Funciones
Plus/Minus Control

Plus/Minus Control

Control of sample's mass carried out with reference to specified MIN and MAX thresholds. The weight is considered to be correct if it is comprised within threshold values. A graphic visualisation of weighing result is displayed in a form of a bar graph.
Percent Weighing

Percent Weighing

Percent Weighing function is used for comparision of measured products with mass standard. Mass of a mass standard may be a numeric value taken from a database or it may be determined through a measurement process. Each measured product is compared to mass standard, mass of which is presumed as a model 100% ideal mass. For products weighing less than the mass standard, obtained results are lower than 100%, for products weighing more, the obtained results are greatly  exceeded.
Totalizing

Totalizing

Function adding new mass value to already obtained one. This allows to determine mass content of the mixture, being a composition of number of different consistence components. Totalizing is limited by maximum capacity parameter.
Parts counting

Parts counting

Function using mass measurement for determination of  measured items quantity. Mass of a single item is required for this process. It may be either estimated through weighment or taken from a database. For items counting the following algorithm is used: all items mass / single item mass = quantity. Function operation is supperted by a mechanism of Automatic Correction of Accuracy. This allows to update single item mass in course of the process. To a certain extend Automatic Correction of Accuracy eliminates error which may be a result of different mass values of seemingly alike single elements. For industry solutions items counting may be simultaneously carried out with checkweighing and dosing thus industry solutions feature audio signalling base informing that specified number of items has been weighed. It is possible to apply weighing systems using few platfroms of different MAX capacities and different accuracies.
Internal battery

Internal battery

Internal and rechargeable battery of SLA 6 V type (sealed lead acid) enables device operation without connecting the device to the mains (9h operation). The weighing instrument controls battery status and displays a respective pictogram on the screen.
Peak hold

Peak hold

Function registering the greatest temporary indication occurring in course of the weighing process. It is most often used in medical scales in order to hold the measurement indication.
GLP Procedures

GLP Procedures

Diagnostic function allowing to objectively document performed measurements. GLP procedures may be either presented in a short report form or extended one.
Animal weighing

Animal weighing

Process of mass determination for a product which may unwillingly reposition within the weighing pan. Mass determination in such cases requires much longer period of time when compared to typical weighing process. It is the user who defines period of time needed for control of measured product mass. The user can thus optimize the function depending on the measured product characteristics.
ALIBI Memory

ALIBI Memory

"ALIBI" memory enables saving and storing up to 100000 measurements.  Measurements are saved automatically upon each pressing of the key. There is no need for any additional operations or changing settings.
The following data related with the measurements is saved: measurement date; measurement time; result (mass); tare value; operator carrying out the measurement (logged in); product name.
The software saves the measurement in a so called loop, i.e. when the measurement no. 100001 is saved, the measurement 1 gets automatically deleted from the memory.
Measurements saved to balance memory cannot be deleted.
You can preview and print out the data saved to the ALIBI database.
Documentación
Tarjetas de productos
Data Sheet Data Sheet
Data Sheet

Ver
Ver
Guardar
Guardar

Choose more product:
Ver Ver GuardarGuardar
Manual de usuario
Manual de instrucciones - CBCP 01
Manual de instrucciones - CBCP 01
Ver
Ver
Guardar
Guardar
(0.29 MB)
Start up Guide
Start up Guide
Ver
Ver
Guardar
Guardar
(0.71 MB)
Quick start
Quick start
Ver
Ver
Guardar
Guardar
(2.47 MB)
Manual de instrucciones - Instrucciones de software PUE C315
Manual de instrucciones - Instrucciones de software PUE C315
Ver
Ver
Guardar
Guardar
(0.63 MB)
Publicaciones y folletos
C315 Platform Scales
C315 Platform Scales
Ver
Ver
Guardar
Guardar
(2.13 MB)
Stainless Steel in RADWAG products. Standard and special applications
Stainless Steel in RADWAG products. Standard and special applications
Ver
Ver
Guardar
Guardar
(2.23 MB)
Documentación técnica
Pit installation frame
Pit installation frame
Ver
Ver
Guardar
Guardar
(0.13 MB)
Accesorios
R-LAB

Accesorios

Newsletter

Suscríbete al newsletter si quieres recibir información sobre las novedades de RADWAG.

Ver más
RADWAG Balanzas Electrónicas
Torunska 5
26-600 Radom
Poland
tel.: +48 48 386 60 00
e-mail: export@radwag.com
TIN: PL7960000327
Vimeo Radwag YouTube Radwag Facebook Radwag LinkedIn Radwag
© 2024 RADWAG Balances and Scales. All rights reserved.

Selecionar idioma

×
Change language AlbanianAlbanian
Change language DanishDanish
Change language NederlandseNederlandse
Change language EstonianEstonian
Change language FinnishFinnish
Change language HungarianHungarian
Change language IcelandicIcelandic
Change language KazakhKazakh
Change language LatvianLatvian
Change language LithuanianLithuanian
Change language MacedonianMacedonian
Change language NorwegianNorwegian
Change language PortuguesePortuguese
Change language RomanianRomanian
Change language RussianRussian
Change language SlovakSlovak
Change language SlovenianSlovenian
Change language SwedishSwedish
Change language UkrainianUkrainian
Change language SerbianSerbian
Change language MontenegrinMontenegrin
Change language page on Deutsch Deutsch
Change language page on English English
Change language page on Français Français
Change language page on Italiano Italiano
Change language page on Polski Polski
Change language page on Türkiye Türkiye
Česky
Português (Brasil)
Change website to USA USA
Change language page on 中文 中文
Presentations Presentations Presentations
Subscribe Subscribe Subscribe
Radwag in Facebook Radwag in Facebook Facebook
Radwag in YouTube Radwag in YouTube Youtube
Radwag in Vimeo Radwag in Vimeo Vimeo
Radwag in LinkedIn Radwag in LinkedIn LinkedIn
Webinars Radwag Webinars Radwag Webinars
close
E-mail:
Nombre de empresa
Nombre:
I consent to the processing of my personal data for marketing purposes by Radwag Wagi Elektroniczne Witold Lewandowski.
I consent to receive marketing and product-related messages by electronic means from Radwag Wagi Elektroniczne Witold Lewandowski.
I have read the Privacy Policy of RADWAG Wagi Elektroniczne Witold Lewandowski.
lock_openI want to access the files
close
Slide to go back ↩