Para comparar : Balanzas de paleta C315.4P.1500.C

Selected language Español Español
Change language
Change language page on Deutsch DeutschChange language page on English EnglishChange language page on Français FrançaisChange language page on Italiano ItalianoChange language page on Polski PolskiChange language page on Türkiye Türkiye ČeskyChange website to USA USAChange language page on 中文 中文

Balanzas de paleta C315.4P.1500.C

Balanzas de paleta C315.4P.1500.C - La báscula para paletas es una estructura de cuatro sensores estable y probada diseñada para pesar paletas. La carga se puede colocar en la báscula con una carretilla elevadora o grúa típica
This image is for reference only.

Código de producto: WP-230-0021
Preguntar sobre producto

Descripción

Maxima capacidad: 1500kg
Legibilidad [d]: 500g

La báscula para paletas es una estructura de cuatro sensores estable y probada diseñada para pesar paletas. La carga se puede colocar en la báscula con una carretilla elevadora o grúa típica.
La báscula de paletas está equipada con ruedas y asas, lo que facilita enormemente el transporte al lugar de uso.
La escala está hecha de acero con recubrimiento en polvo. Tiene un Indicador PUE C315 con pantalla LCD retroiluminada instalada en un cable, que está protegido por un conducto de protección.
La longitud del cable que conecta el indicador con la plataforma - 3m.

Es posible hacer una

balanza

de doble rango por una tarifa adicional.

Funciones

Plus/Minus Control

Plus/Minus Control

Control of sample's mass carried out with reference to specified MIN and MAX thresholds. The weight is considered to be correct if it is comprised within threshold values. A graphic visualisation of weighing result is displayed in a form of a bar graph.
Percent Weighing

Percent Weighing

Percent Weighing function is used for comparision of measured products with mass standard. Mass of a mass standard may be a numeric value taken from a database or it may be determined through a measurement process. Each measured product is compared to mass standard, mass of which is presumed as a model 100% ideal mass. For products weighing less than the mass standard, obtained results are lower than 100%, for products weighing more, the obtained results are greatly  exceeded.
Totalizing

Totalizing

Function adding new mass value to already obtained one. This allows to determine mass content of the mixture, being a composition of number of different consistence components. Totalizing is limited by maximum capacity parameter.
Parts counting

Parts counting

Function using mass measurement for determination of  measured items quantity. Mass of a single item is required for this process. It may be either estimated through weighment or taken from a database. For items counting the following algorithm is used: all items mass / single item mass = quantity. Function operation is supperted by a mechanism of Automatic Correction of Accuracy. This allows to update single item mass in course of the process. To a certain extend Automatic Correction of Accuracy eliminates error which may be a result of different mass values of seemingly alike single elements. For industry solutions items counting may be simultaneously carried out with checkweighing and dosing thus industry solutions feature audio signalling base informing that specified number of items has been weighed. It is possible to apply weighing systems using few platfroms of different MAX capacities and different accuracies.
Internal battery

Internal battery

Internal and rechargeable battery of SLA 6 V type (sealed lead acid) enables device operation without connecting the device to the mains (9h operation). The weighing instrument controls battery status and displays a respective pictogram on the screen.
Peak hold

Peak hold

Function registering the greatest temporary indication occurring in course of the weighing process. It is most often used in medical scales in order to hold the measurement indication.
GLP Procedures

GLP Procedures

Diagnostic function allowing to objectively document performed measurements. GLP procedures may be either presented in a short report form or extended one.
Animal weighing

Animal weighing

Process of mass determination for a product which may unwillingly reposition within the weighing pan. Mass determination in such cases requires much longer period of time when compared to typical weighing process. It is the user who defines period of time needed for control of measured product mass. The user can thus optimize the function depending on the measured product characteristics.
ALIBI Memory

ALIBI Memory

"ALIBI" memory enables saving and storing up to 100000 measurements.  Measurements are saved automatically upon each pressing of the key. There is no need for any additional operations or changing settings.
The following data related with the measurements is saved: measurement date; measurement time; result (mass); tare value; operator carrying out the measurement (logged in); product name.
The software saves the measurement in a so called loop, i.e. when the measurement no. 100001 is saved, the measurement 1 gets automatically deleted from the memory.
Measurements saved to balance memory cannot be deleted.
You can preview and print out the data saved to the ALIBI database.

Datos tecnicos

Maxima capacidad

1500

 kg

Minima cacacidad

10

 kg

Legibilidad [d]

500

 g

Rango de tara

-1500

 kg

Pantalla

LCD (con retroiluminación)

 

Grado de protección

IP 65 construcción, IP 67 extensómetro, IP 43 medidor

 

Interface RS232

1× standard, 1× opción

 

Interface Wi-Fi®

1× standard

 

Alimentacion

100 ÷ 240 V AC 50 / 60 Hz + bateria

 

Horas de trabajo con baterias

max 8h

 

Temperatura de trabajo

-10 ÷ +40

 °C

Humedad relativa de aire

10% ÷ 85% RH sin condensación

 

Dimensión de platillo

840×1200

 mm

Dimensiones de aparato

1322×840×85

 mm

Masa de balanza con indicador

43

 kg

Documentación

Documentación técnica
Publicaciones y materiales didácticos
Manual de instrucciones
(1.21 MB)
Save See the publication
Manual de instrucciones
(0.29 MB)
Save See the publication
Data Sheet
(0.71 MB) EN
Save See the publication
Conformity Declaration
(0.04 MB) EN
Save See the publication
C315 Platform Scales
(2.13 MB) EN
Save See the publication
Measuring_instruments_in_industry
(0.05 MB) EN
Save See the publication

Programas

Software

R-Lab (149.39 MB)
Descargar la versión del software con un límite de 1.000 pesajes

Accesorios

Editor de Balanzas 2.0
RW Tool
R-LAB
RAD KEY
Controlador LabVIEW “Radwag Balances & Scales”
Impresoras de recibos
Cables RS 232 (Bascula a Impresora EPSON)
Cables RS 232, RS 485
Cables de corriente desde mechero de automóvil
Soportes, brazos
Convertidor RS232 a RS485
Convertidor RS232 a Ethernet
Salidas del bucle de corriente
Pantallas

RADWAG Balanzas Electrónicas

Torunska 5
26-600 Radom
Poland
tel.: +48 48 386 60 00
e-mail: export@radwag.com
TIN: PL7960000327
Vimeo Radwag YouTube Radwag Facebook Radwag
© 2019 RADWAG Balances and Scales. All rights reserved.

Watch more
RADWAG videos

movie
Radwag WEBINARS