Wasserdichte Plattformwaage WPT 15/H3/5

Wasserdichte Plattformwaage WPT 15/H3/5 - Die Konstruktion wird vollständig aus OH18N9-Edelstahl gefertigt. Die Waage wird mit Stromversorgung 100-240 V AC betrieben
This image is for reference only.

Produktcode: WP-105-0105
Kontaktformular

Beschreibung

Wägebereich [Max]: 30kg
Ziffernschritt [d]: 10g

Die wasserdichten Plattformwaagen wurden zum Einsatz unter schwierigen Bedingungen bei großer Feuchtigkeit oder direkten Kontakt mit Wasser entwickelt. Die

Waage

ist mit dem PUE C/31H-Wägeterminal mit einem hinterleuchteten LCD-Display ausgestattet. Die Konstruktion wird vollständig aus OH18N9-Edelstahl gefertigt. Die

Waage

wird mit Stromversorgung 100-240 V AC betrieben. Serienmäßig ist Waage mit einer RS-232-Schnittstelle ausgestattet.

Auf Anfrage können

Waagen

auch mit zwei Messbereichen geliefert werden.

Funktionen

Plus/Minus Control

Plus/Minus Control

Control of sample's mass carried out with reference to specified MIN and MAX thresholds. The weight is considered to be correct if it is comprised within threshold values. A graphic visualisation of weighing result is displayed in a form of a bar graph.
Percent Weighing

Percent Weighing

Percent Weighing function is used for comparision of measured products with mass standard. Mass of a mass standard may be a numeric value taken from a database or it may be determined through a measurement process. Each measured product is compared to mass standard, mass of which is presumed as a model 100% ideal mass. For products weighing less than the mass standard, obtained results are lower than 100%, for products weighing more, the obtained results are greatly  exceeded.
Totalizing

Totalizing

Function adding new mass value to already obtained one. This allows to determine mass content of the mixture, being a composition of number of different consistence components. Totalizing is limited by maximum capacity parameter.
Parts counting

Parts counting

Function using mass measurement for determination of  measured items quantity. Mass of a single item is required for this process. It may be either estimated through weighment or taken from a database. For items counting the following algorithm is used: all items mass / single item mass = quantity. Function operation is supperted by a mechanism of Automatic Correction of Accuracy. This allows to update single item mass in course of the process. To a certain extend Automatic Correction of Accuracy eliminates error which may be a result of different mass values of seemingly alike single elements. For industry solutions items counting may be simultaneously carried out with checkweighing and dosing thus industry solutions feature audio signalling base informing that specified number of items has been weighed. It is possible to apply weighing systems using few platfroms of different MAX capacities and different accuracies.
Internal battery

Internal battery

Internal and rechargeable battery of SLA 6 V type (sealed lead acid) enables device operation without connecting the device to the mains (9h operation). The weighing instrument controls battery status and displays a respective pictogram on the screen.
Peak hold

Peak hold

Function registering the greatest temporary indication occurring in course of the weighing process. It is most often used in medical scales in order to hold the measurement indication.
Animal weighing

Animal weighing

Process of mass determination for a product which may unwillingly reposition within the weighing pan. Mass determination in such cases requires much longer period of time when compared to typical weighing process. It is the user who defines period of time needed for control of measured product mass. The user can thus optimize the function depending on the measured product characteristics.

Technische Daten

Wägebereich [Max]

30

 kg

Min. Belastung

200

 g

Ziffernschritt [d]

10

 g

Tarierbereich

-30

 kg

OIML-Klasse

III

 

Display

LCD (hinterleuchtet)

 

Schutzart

IP 67 Konstruktion, IP 68 (1h max)/69 Messgerät

 

Schnittstelle

RS232

 

Stromversorgung

100 ÷ 240 V AC 50 / 60 Hz und Akkus

 

Akku-Betriebszeit

45 Stunden (mittlere Zeit)

 

Umgebungstemperatur

-10 ÷ +40

 °C

Relative Luftfeuchtigkeit

10% ÷ 85% RH ohne Kondensation

 

Waagschale

400×600

 mm

Verpackungsgröße

670×510×330

 mm

Nettogewicht

15,5

 kg

Bruttogewicht

17,3

 kg

Dokumentation

Technische Dokumentation
Publikationen und Lerninhalte
Bedienungsanleitungen
(2.14 MB)
Save See the publication
Data Sheet
(1.03 MB) EN
Save See the publication
Conformity Declaration
(0.03 MB) EN
Save See the publication
Wageterminals und Industriewaagen
(4.81 MB)
Save See the publication
Measuring_instruments_in_industry
(0.05 MB) EN
Save See the publication

Zubehör

Granit-Antivibrationstisch
Rahmen mit Rollenförderern
Waagen-Editor
R-LAB
RAD KEY
LabVIEW Driver
Thermische Drucker
Ausgang der Stromschnittstelle AP2-3
Anschlusskabel für Zigarettenanzünder
Kabel RS 232RS 485
Kabel RS 232 (Waage – Drucker EPSON)
Displays
Konverter RS232 – Ethernet

RADWAG Elektronische Waagen

Torunska 5
26-600 Radom
Polen
Tel.: +48 48 386 60 00
E-mail: export@radwag.com
VAT Nr.: 796-000-03-27
Vimeo Radwag YouTube Radwag Facebook Radwag
© 2019 RADWAG Elektronische Waagen. Alle Rechte vorbehalten.

Watch more
RADWAG videos

movie
Radwag WEBINARS