zum Vergleich : Roboterwaage zum Wiegen von Filtern RB 2.4Y.F

Selected language Deutsch Deutsch
Change language
Change language page on English EnglishChange language page on Español EspañolChange language page on Français FrançaisChange language page on Italiano ItalianoChange language page on Polski PolskiChange language page on Türkiye Türkiye ČeskyChange website to USA USAChange language page on 中文 中文

Roboterwaage zum Wiegen von Filtern RB 2.4Y.F

Roboterwaage zum Wiegen von Filtern RB 2.4Y.F - Die Roboterwaage zum Wiegen von Filtern RB 2.4Y
This image is for reference only.

Produktcode: WL-101-0198
Kontaktformular

Beschreibung

Wägebereich [Max]: 2,1g
Ziffernschritt [d]: 1µg

Die Roboterwaage zum Wiegen von Filtern RB 2.4Y.F bietet das professionelle Niveau des Wiegens an und ermöglicht die vollständige Automatisierung der Massenmessungen  von Filtern. Die

Waage

RB 2.4Y.F ist mit dem gleichen Wiegemechanismus wie die Mikrowaage MYA 4Y ausgestattet, der die unvergleichlichen Wiederholbarkeit und  Ziffernschritt d= 1 µg garantiert. Das Gerät erlaubt das Wiegen bis zu 1050 Filter mit dem Durchmesser von 47 mm.
Das Gerät befindet sich in der hermetischen Kammer, die vor Staub und anderen Verunreinigungen schützt.
Das Klima- und Befeuchtungssystem garantiert konstante klimatische Bedingungen in der Kammer, was eine ordnungsgemäße Filterkonditionierung gewährleistet.
Die Überwachung der Umgebungsbedingungen kontrolliert die aktuellen Bedingungen in der Kammer und ermöglicht diese Daten zu speichern und zu melden.
Hauptvorteile:
  • Vollautomatisches Wiegesystem von Filtern mit dem Durchmesser von Ø 47 mm
  • Konformität mit der Norm EN 12341:2014
  • Möglichkeit der Überprüfung zu 1050 Filter
  • Zusätzliches Referenzmagazin
  • Zeitersparnis im Vergleich zum manuellen Wiegen von Filtern
  • Eliminierung des menschlichen Faktors als Grund für das Auftreten von Messfehlern
  • Verwaltung des Processus dank der Software RMCS Filter
  • Automatische Datenaufzeichnung, die Möglichkeit Berichte und Statistiken zu erstellen
  • Kodierung und Identifikation von Filtern dank dem QR-Code-System
  • Eliminierung des Einflusses der Elektrostatik auf die Messung
  • Dichtheit der Roboterkammer und der Wiegekammer von Filtern
  • Klimaanlage, HEPA-Filter (Ausführung ohne Klimaanlage auf Anfrage)
  • Erhöhter Druck in der Kammer verhindert das Eindringen von Schmutz
Die Roboterwaage für das Wiegen von Filtern RB 2.4Y.F besteht aus:
  • zwei Magazine für Speicherung von Filtern vor und nach dem Wiegen. Einer von ihnen wird während des Filterwägens verwendet, der andere ist das Magazin zur Konditionierung. Jedes besteht aus 35 Scheiben mit 15 Filterpositionen.
  • Referenzmagazin mit sechs Positionen zur Aufbewahrung von Prüfgewichten und Referenzfiltern.
  • Roboter mit einem Greifer, der den Transport von Filtern zwischen dem Magazin und Mikrowaage ermöglicht. Es bewegt sich in drei Achsen X, Y, Z.
  • Mikrowaage mit einem Windschutz
  • Ionisationssystem
  • Klimaanlage reinigt zusammen mit dem HEPA-Filter die Luft, die aus der Umgebung in die Roboterkammer gelangt
  • Überwachung der Umgebungsbedingungen, vor allem der Temperatur, der Luftfeuchtigkeit und des Drucks
  • Messgerät verwaltet den Betrieb des Geräts
  • Barcode-Scanner QR im Gerät eingebaut
  • Drucker von QR-Coden
  • Computer PC mit der RMCS Filter-Software, der den Betrieb des gesamten Geräts verwaltet
  • Steuerungs- und Regelsysteme
  • Außen Aggregat des Klimaanlages

Videos

RB 4Y.F - Automation of Filter Weighing

Merkmale

Elektronische Libelle
Funktionalität:
  • ALARM
  • graphische Nivellierungsanzeige
  • programmierbare Toleranzen

Elektronische Libelle

Funktionalität:
  • ALARM
  • graphische Nivellierungsanzeige
  • programmierbare Toleranzen
Datenaustausch (USB)
  • Softwareupdates
  • Export von Wägedaten
  • Export/Import von Datenbanken
  • Export/Import von Waageneinstellungen
  • Datenaustausch zwischen Waagen

Datenaustausch (USB)

  • Softwareupdates
  • Export von Wägedaten
  • Export/Import von Datenbanken
  • Export/Import von Waageneinstellungen
  • Datenaustausch zwischen Waagen
Infrarotsensoren
Funktionalität:
  • PRINT-Funktion
  • TARA-Funktion

Infrarotsensoren

Funktionalität:
  • PRINT-Funktion
  • TARA-Funktion
Kabellose Kommunikation
Optionale Ausführung:
Kabellose Kommunikation der Wägekammer mit dem Terminal.

Kabellose Kommunikation

Anwendung:
1. Beseitigung von zusätzlichen Vibrationsquellen Ein Standort des Terminals außerhalb des Wägetisches beseitigt Vibrationen, die bei der Bedienung entstehen. Dies ermöglicht einen stabilen Betrieb bei höchsten Auflösungen ohne Anwendung von speziellen Wägearbeitsplätzen.
2. Bequemes und komfortables Wägen unter Abzügen und auf Sicherheitswerkbänken Die kabellose Kommunikation des Terminals mit dem Wägemodul ermöglicht den Betrieb der Laborwaage unter Abzügen, ein bequemes Arbeiten und mehr Sicherheit.
3. Isolation der Waage von ungünstigen Umgebungsbedingungen Die kabellose Kommunikation ermöglicht das Aufstellen des Wägemoduls in Windschutzschränken oder eine vollständige Isolation vom Bediener. Diese Lösung ermöglicht das Wägen von kontaminierten oder toxischen Substanzen ohne Gefahr für die Gesundheit des Bedieners.
Interfaces
  • Ethernet
  • 2×USB
  • 2×RS 232
  • 4 in / 4 out
  • WiFi 2,4GHz b,g,n

Interfaces

  • Ethernet
  • 2×USB
  • 2×RS 232
  • 4 in / 4 out
  • WiFi 2,4GHz b,g,n

Funktionen

Autotest

Autotest

Diagnostic function aiming at metrological parameters determination (repeatability), the parameters are determined for the actual conditions of use. When speaking of repeatability it may be also used for weighing time optimization. Autotest is operated in an automatic mode thus operator’s time is saved.
Dosing

Dosing

Weighing process for which reference mass has been determined together with tolerance for its determination. Dosing tolerance is given in [%] and it is calculated in relation to the reference value thus being a permissible deviation of this process. This solution is used for weighing powders, liquids and loose materials. Dosing function performance is often supported with bargraph - load indicator. For industrial scales it is possible to use a control systems of dosing process.
Percent Weighing

Percent Weighing

Percent Weighing function is used for comparision of measured products with mass standard. Mass of a mass standard may be a numeric value taken from a database or it may be determined through a measurement process. Each measured product is compared to mass standard, mass of which is presumed as a model 100% ideal mass. For products weighing less than the mass standard, obtained results are lower than 100%, for products weighing more, the obtained results are greatly  exceeded.
Parts counting

Parts counting

Function using mass measurement for determination of  measured items quantity. Mass of a single item is required for this process. It may be either estimated through weighment or taken from a database. For items counting the following algorithm is used: all items mass / single item mass = quantity. Function operation is supperted by a mechanism of Automatic Correction of Accuracy. This allows to update single item mass in course of the process. To a certain extend Automatic Correction of Accuracy eliminates error which may be a result of different mass values of seemingly alike single elements. For industry solutions items counting may be simultaneously carried out with checkweighing and dosing thus industry solutions feature audio signalling base informing that specified number of items has been weighed. It is possible to apply weighing systems using few platfroms of different MAX capacities and different accuracies.
Formulation

Formulation

Function supporting the mixture making process, wherein the mixture contains various components. Formulation function usually uses the balance/scale database of components. Formulation serves for monitored checkweighing of every single component with a given tolerance. It is enriched with a set of individual settings.
Statistics

Statistics

Statistiscs function registers and analyses performed measurements. This supplies the user withthe following information: Max and Min standard deviation, average value, variance, range et.
Checkweighing

Checkweighing

Checkweighing function is used for checking whether the measured sample mass is within the predefined threshold values, Low [LO] and Hgh [HI]. The thresholds are given in [g] and [kg] units. Current state of a sample being measured is signalled by means of pictorgams located on a display for laboratory balances, for industrial scales Stackligt System is used. This visual +/- inspection is in operation during segregation, control or packing process of products for which mass has bees determined with a specifaied tolerance, eg. 12860 g 961
IR sensors

IR sensors

Programmable function supporting the weighing process through control of the following options: sliding weighing chamber doors, printout, zeroing, tarring etc. Especially appreciated wherever preventing the balance from soiling is important.
GLP Procedures

GLP Procedures

Diagnostic function allowing to objectively document performed measurements. GLP procedures may be either presented in a short report form or extended one.
Animal weighing

Animal weighing

Process of mass determination for a product which may unwillingly reposition within the weighing pan. Mass determination in such cases requires much longer period of time when compared to typical weighing process. It is the user who defines period of time needed for control of measured product mass. The user can thus optimize the function depending on the measured product characteristics.
Air density correction

Air density correction

Function performing correction of mass measurement indication, wherein the air density is taken into account. It is used in balances with reading unit < 0,01 mg.
Differential weighing

Differential weighing

Differential weighing informs about mass variation a particular sample, wherein the said variation is a result of manufacturing processes.

Differential weighing is often applied in product control process, for which reference product parameters have been specified in order to be used as a source of comparison for the whole series.
Insuchcasestandard deviation is the information which tells about quality and completeness of a final product. For systems based on a feed-back technique such information may be used by control units.
Replaceable unit

Replaceable unit

Replaceable units.
Statistical Quality Control

Statistical Quality Control

Statistical control for determination of basic statistical criteria: maximum, minimum, standard deviation, mean values for each batch, etc.
ALIBI Memory

ALIBI Memory

"ALIBI" memory enables saving and storing up to 100000 measurements.  Measurements are saved automatically upon each pressing of the key. There is no need for any additional operations or changing settings.
The following data related with the measurements is saved: measurement date; measurement time; result (mass); tare value; operator carrying out the measurement (logged in); product name.
The software saves the measurement in a so called loop, i.e. when the measurement no. 100001 is saved, the measurement 1 gets automatically deleted from the memory.
Measurements saved to balance memory cannot be deleted.
You can preview and print out the data saved to the ALIBI database.

Technische Daten

Wägebereich [Max]

2,1

 g

Ziffernschritt [d]

1

 µg

Tarierbereich

-2,1

 g

Eichwert

1

 mg

Wiederholbarkeit (Max)

1 - 2

 µg

Wiederholbarkeit (5% Max)

0,25

 µg

Linearität

≤ 1,5

 µg

Stabilisierungszeit

10 - 20

 s

Justierung

extern

 

OIML-Klasse

I

 

Display

5,7” resistiv farbiger touchscreen

 

Berührungslose Bedienung

zwei IR-Sensoren

 

Schnittstelle

2×RS232, 2×USB, Ethernet, 4 IN / 4 OUT (digital)

 

Stromversorgung

100 ÷ 240 V AC 50 / 60 Hz

 

Maximaler Leistungsaufnahme

10 W

 

Umgebungstemperatur

+10 ÷ +40

 °C

Lagertemperatur

-20 ÷ +50

 °C

Änderungsgeschwindigkeit Temperatur

±0,3°C/1h (±1°C/8h)

 

Relative Luftfeuchtigkeit

40% ÷ 80%

 

Änderungsgeschwindigkeit relative Luftfeuchtigkeit

±1%/h (±4%/8h)

 

Tastatur

8 przycisków

 

Abmessungen Gerät

1590×2140×1410

 mm

Nettogewicht

700

 kg

Bruttogewicht

775

 kg

Wiederholbarkeit wird als Standardabweichung von 10 Wägezyklen ausgedrückt.
Die Stabilisierungszeit ist abhängig von den Umgebungsbedingungen und der Geschwindigkeit bei Auflegen der Last auf der Waagschale; für FAST-Profil definiert.

Dokumentation

Technische Dokumentation
Publikationen und Lerninhalte
Conformity Declaration
(0.04 MB) EN
Save See the publication
RB 2.4Y.F Filter Weighing Robot
(6.17 MB) EN
Save See the publication
Defined Weighing Profiles
(1.36 MB) EN
Save See the publication
THBR System 2.0
(5.17 MB) EN
Save See the publication
Detection of vibrations at the electronic balances workstation
(2.02 MB) EN
Save See the publication
4Y - Neue Serie Der Laborwaagen
(1.76 MB)
Save See the publication
Waagen der Serie 4Y
(2.35 MB)
Save See the publication
Ultra-Mikrowaagen und Mikrowaagen
(1.67 MB)
Save See the publication
Micro Scale Measurement
(2.74 MB) EN
Save See the publication
Principles_of_metrology
(0.10 MB) EN
Save See the publication
Guidelines for a weighing room for correct microbalance and mass comparator operation
(0.82 MB) EN
Save See the publication
SQC in laboratory
(2.31 MB) EN
Save See the publication
Microbalances working conditions
(2.25 MB) EN
Save See the publication

Zusätzliche Module

Modul der Konformität mit 21 CFR Teil 113

RADWAG Elektronische Waagen

Torunska 5
26-600 Radom
Polen
Tel.: +48 48 386 60 00
E-mail: export@radwag.com
VAT Nr.: 796-000-03-27
Vimeo Radwag YouTube Radwag Facebook Radwag
© 2019 RADWAG Elektronische Waagen. Alle Rechte vorbehalten.

Watch more
RADWAG videos

movie
Radwag WEBINARS