Max: 20kgd: 0,1g

 195×195mm
expand_more
Max: 1kgd: 0,01g

 195×195mm
Max: 2kgd: 0,01g

 195×195mm
Max: 6kgd: 0,1g

 195×195mm
Max: 6kgd: 0,1g

 300×300mm
Max: 6kgd: 0,1g

 300×300mm
Max: 10kgd: 0,1g

 195×195mm
Max: 12kgd: 0,2g

 300×300mm
Max: 12kgd: 0,2g

 300×300mm
Max: 30kgd: 0,5g

 300×300mm
Max: 30kgd: 0,5g

 300×300mm
Max: 60kgd: 1g

 400×500mm
Max: 60kgd: 1g

 400×500mm
Max: 120kgd: 2g

 400×500mm
Max: 120kgd: 2g

 400×500mm
Maximum capacity [Max]: 20 kg
Readability [d]: 0,1 g

close
Change the model:
WLY 1/D2 Precision Balance
WLY 2/D2 Precision Balance
WLY 6/D2 Precision Balance
WLY 6/F1/R Precision Balance
WLY 6/F1/K Precision Balance
WLY 10/D2 Precision Balance
WLY 12/F1/K Precision Balance
WLY 12/F1/R Precision Balance
WLY 20/D2 Precision Balance
WLY 30/F1/R Precision Balance
WLY 30/F1/K Precision Balance
WLY 60/C2/R Precision Balance
WLY 60/C2/K Precision Balance
WLY 120/C2/R Precision Balance
WLY 120/C2/K Precision Balance
Select all
View
Download
Add to compare Advanced Search
Overview

WLY 20/D2 Precision Balance

 
Fast and accurate weight determination thanks to the duo: the WLY multifunction balance and the PUE7 weighing terminal. Ease of operation and maximum automation of the weighing process.
 
 
 

Not just weighing

But also parts counting, checkweighing, percent weighing, animal weighing, formulations and differential weighing. The power of WLY’s working mods.
 
 
 

Use the potential

Barcode scanners, receipt printers, label printers, RFID readers, PC equipment or an additional weighing platform – thanks to multipurpose software, WLY balance can work with all of them. You can find all accessories in our regular offer. And if you have questions about compatibility, our experts will help you.
 
 
 

The Workflow Module

will improve work in your company. It enables developing a path of customized weighing process adapted to individual requirements of a particular production system, and next sending it to all weighing instruments cooperating with the E2R. The given process is started on the weighing instrument upon operator logging or after selecting a product, a formulation or an ingredient to which it is assigned. Modifications are made with use of convenient and intuitive interface.
 
 
 

DIY with WLY

With WLY you will Do It Yourself:
  • You will program on-screen keys and functional keys
  • You will program infrared proximity sensors
  • You will design printouts
  • You will design text data that is displayed in an indicator display.
 
This balance is the result of a combination of our experience and true precision.
 
 
 

Want to generate labels?

You can. With Label Editor software, you will generate:
  • Standard labels for single products
  • C labels for cumulative containers
  • CC labels for containers with cumulative containers.
 
 
THBR 2.0 System
Cooperation with THBR 2.0 System for ambient conditions monitoring.
 
 
Stainless Steel in RADWAG products
Learn about the use and maintenance of stainless steel products:
Stainless Steel in RADWAG products. Standard and special applications
Datasheet
Maximum capacity [Max]

20

 kg

Minimum load

-

 

Readability [d]

0,1

 g

Verification unit [e]

-

 

Tare range

-20

 kg

Repeatability

0,3

 g

Linearity

±0,3

 g

Stabilization time

3

 s

Adjustment

external

 

OIML Class

-

 

Leveling system

manual

 

Weighing pan dimensions

195×195

 mm

Packaging dimensions

530×310×150

 mm

Net weight

2,7

 kg

Gross weight

3,6

 kg

Protection class

IP 43

 

Communication interface

2×RS232, 2×USB-A, Ethernet, 4 IN / 4 OUT (digital), Wi-Fi®

 

Power supply

Adapter: 100 – 240V AC 50/60Hz 1A; 15V DC 2,4A
Balance: 10 – 28V DC 1A max

 

Operating temperature

+15 – +30

 °C

Storage temperature

-25 – +70

 °C

Relative humidity

10% – 85% RH no condensation

 

CE
Repeatability is expressed as a standard deviation from 10 weighing cycles.
Stabilization time depends on the ambient conditions and the dynamics of weighing pan loading; specified for FAST profile.
Videos
Easy Printing with Wi-Fi® Thermal Receipt Printer by RADWAG.
Complete Solutions for Mass Measurement in Pharma Industry
Functions
Dosing

Dosing

Weighing process for which reference mass has been determined together with tolerance for its determination. Dosing tolerance is given in [%] and it is calculated in relation to the reference value thus being a permissible deviation of this process. This solution is used for weighing powders, liquids and loose materials. Dosing function performance is often supported with bargraph - load indicator. For industrial scales it is possible to use a control systems of dosing process.
Labelling

Labelling

Marking products with the right symbols contributes to quick and reliable identification. The balance/scale usually transfers product mass or product quantity to the label printer. The transferred value is printed with the following information: bar code, pictogram, content, address etc. In laboratory the labelling is performed in a semi-automatic mode, for industry in an automatic one (dynamic scales).
Plus/Minus Control

Plus/Minus Control

Control of sample's mass carried out with reference to specified MIN and MAX thresholds. The weight is considered to be correct if it is comprised within threshold values. A graphic visualisation of weighing result is displayed in a form of a bar graph.
Percent Weighing

Percent Weighing

Percent Weighing function is used for comparision of measured products with mass standard. Mass of a mass standard may be a numeric value taken from a database or it may be determined through a measurement process. Each measured product is compared to mass standard, mass of which is presumed as a model 100% ideal mass. For products weighing less than the mass standard, obtained results are lower than 100%, for products weighing more, the obtained results are greatly  exceeded.
Totalizing

Totalizing

Function adding new mass value to already obtained one. This allows to determine mass content of the mixture, being a composition of number of different consistence components. Totalizing is limited by maximum capacity parameter.
Parts counting

Parts counting

Function using mass measurement for determination of  measured items quantity. Mass of a single item is required for this process. It may be either estimated through weighment or taken from a database. For items counting the following algorithm is used: all items mass / single item mass = quantity. Function operation is supperted by a mechanism of Automatic Correction of Accuracy. This allows to update single item mass in course of the process. To a certain extend Automatic Correction of Accuracy eliminates error which may be a result of different mass values of seemingly alike single elements. For industry solutions items counting may be simultaneously carried out with checkweighing and dosing thus industry solutions feature audio signalling base informing that specified number of items has been weighed. It is possible to apply weighing systems using few platfroms of different MAX capacities and different accuracies.
Peak hold

Peak hold

Function registering the greatest temporary indication occurring in course of the weighing process. It is most often used in medical scales in order to hold the measurement indication.
Formulation

Formulation

Function supporting the mixture making process, wherein the mixture contains various components. Formulation function usually uses the balance/scale database of components. Formulation serves for monitored checkweighing of every single component with a given tolerance. It is enriched with a set of individual settings.
Statistics

Statistics

Statistiscs function registers and analyses performed measurements. This supplies the user withthe following information: Max and Min standard deviation, average value, variance, range et.
Checkweighing

Checkweighing

Checkweighing function is used for checking whether the measured sample mass is within the predefined threshold values, Low [LO] and Hgh [HI]. The thresholds are given in [g] and [kg] units. Current state of a sample being measured is signalled by means of pictorgams located on a display for laboratory balances, for industrial scales Stackligt System is used. This visual +/- inspection is in operation during segregation, control or packing process of products for which mass has bees determined with a specifaied tolerance, eg. 12860 g 961
IR sensors

IR sensors

Programmable function supporting the weighing process through control of the following options: sliding weighing chamber doors, printout, zeroing, tarring etc. Especially appreciated wherever preventing the balance from soiling is important.
Animal weighing

Animal weighing

Process of mass determination for a product which may unwillingly reposition within the weighing pan. Mass determination in such cases requires much longer period of time when compared to typical weighing process. It is the user who defines period of time needed for control of measured product mass. The user can thus optimize the function depending on the measured product characteristics.
Differential weighing

Differential weighing

Differential weighing informs about mass variation a particular sample, wherein the said variation is a result of manufacturing processes.

Differential weighing is often applied in product control process, for which reference product parameters have been specified in order to be used as a source of comparison for the whole series.
Insuchcasestandard deviation is the information which tells about quality and completeness of a final product. For systems based on a feed-back technique such information may be used by control units.
ALIBI Memory

ALIBI Memory

"ALIBI" memory enables saving and storing up to 100000 measurements.  Measurements are saved automatically upon each pressing of the key. There is no need for any additional operations or changing settings.
The following data related with the measurements is saved: measurement date; measurement time; result (mass); tare value; operator carrying out the measurement (logged in); product name.
The software saves the measurement in a so called loop, i.e. when the measurement no. 100001 is saved, the measurement 1 gets automatically deleted from the memory.
Measurements saved to balance memory cannot be deleted.
You can preview and print out the data saved to the ALIBI database.
Documentation
Data Sheet Data Sheet
Data Sheet

View
View
Download
Download

Choose more product:
View View DownloadDownload
Software Manual - CBCP 03
Software Manual - CBCP 03
View
View
Download
Download
(0.23 MB)
User Manual - WLY Multifunctional Scale
User Manual - WLY Multifunctional Scale
View
View
Download
Download
(1.63 MB)
Software Manual - MODBUS communication protocol of PUE 7.1 / PUE HY10
Software Manual - MODBUS communication protocol of PUE 7.1 / PUE HY10
View
View
Download
Download
(0.82 MB)
Software Manual - Appendices 01
Software Manual - Appendices 01
View
View
Download
Download
(1.81 MB)
Start up Guide
Start up Guide
View
View
Download
Download
(1.92 MB)
Software Manual - PUE 7.1
Software Manual - PUE 7.1
View
View
Download
Download
(6.55 MB)
Conformity Declaration
Conformity Declaration
View
View
Download
Download
(0.04 MB)
Laboratory balance cleaning
Laboratory balance cleaning
View
View
Download
Download
(2.52 MB)
RTP Thermal Receipt Printer
RTP Thermal Receipt Printer
View
View
Download
Download
(1.64 MB)
THBR System 2.0
THBR System 2.0
View
View
Download
Download
(5.17 MB)
Lexicon of Basic Metrological Terms
Lexicon of Basic Metrological Terms
View
View
Download
Download
(6.31 MB)
Laboratory Balances
Laboratory Balances
View
View
Download
Download
(1.68 MB)
Stainless Steel in RADWAG products. Standard and special applications
Stainless Steel in RADWAG products. Standard and special applications
View
View
Download
Download
(2.23 MB)
PUE 7.1 Terminal
PUE 7.1 Terminal
View
View
Download
Download
(2.33 MB)
Download
Drivers

LabVIEW (3.05 MB)

Accessories

Newsletter

Subscribe to the newsletter if you would like to receive RADWAG news.

View more
Radwag Balances and Scales
Torunska 5
26-600 Radom
Poland
tel.: +48 48 386 60 00
e-mail: export@radwag.com
TIN: PL7960000327
Vimeo Radwag YouTube Radwag Facebook Radwag LinkedIn Radwag
© 2024 RADWAG Balances and Scales. All rights reserved.

Select language

×
Change language AlbanianAlbanian
Change language DanishDanish
Change language NederlandseNederlandse
Change language EstonianEstonian
Change language FinnishFinnish
Change language HungarianHungarian
Change language IcelandicIcelandic
Change language KazakhKazakh
Change language LatvianLatvian
Change language LithuanianLithuanian
Change language MacedonianMacedonian
Change language NorwegianNorwegian
Change language PortuguesePortuguese
Change language RomanianRomanian
Change language RussianRussian
Change language SlovakSlovak
Change language SlovenianSlovenian
Change language SwedishSwedish
Change language UkrainianUkrainian
Change language SerbianSerbian
Change language MontenegrinMontenegrin
Change language page on Deutsch Deutsch
Change language page on English English
Change language page on Español Español
Change language page on Français Français
Change language page on Italiano Italiano
Change language page on Polski Polski
Change language page on Türkiye Türkiye
Česky
Português (Brasil)
Change website to USA USA
Change language page on 中文 中文
Presentations Presentations Presentations
Subscribe Subscribe Subscribe
Radwag in Facebook Radwag in Facebook Facebook
Radwag in YouTube Radwag in YouTube Youtube
Radwag in Vimeo Radwag in Vimeo Vimeo
Radwag in LinkedIn Radwag in LinkedIn LinkedIn
Webinars Radwag Webinars Radwag Webinars
close
E-mail:
Company name:
Name:
I consent to the processing of my personal data for marketing purposes by Radwag Wagi Elektroniczne Witold Lewandowski.
I consent to receive marketing and product-related messages by electronic means from Radwag Wagi Elektroniczne Witold Lewandowski.
I have read the Privacy Policy of RADWAG Wagi Elektroniczne Witold Lewandowski.
lock_openI want to access the files
close
Slide to go back ↩