PUE H315 Weighing Terminal

Selected language
PUE H315 Weighing Terminal
This image is for reference only.

PUE H315 Weighing Terminal

Product code: WX-008-0191
close
Change the model:
PUE H315 Weighing Terminal
Select all
View
Download
Overview
The terminal is intended to be a component of a vast range of industry scales – from small table-top scales, through platform, ramp, track and pallet scales, to livestock scales. It is equipped with a stainless steel housing of high ingress protection, IP 66/IP 67/IP 69. By standard the terminal features RS 232 and USB interfaces.
Operation Ergonomics and Durability
A brand new design of the housing makes the terminal a compact device, which positively influences the comfort of operation. Another useful facility is the multifunctionally, this feature allows to operate the device when placed on a table or mounted to a post. In either case, tilt regulation is available. The said tilt regulation is also a convenience offered by a wall-mounting bracket.
Besides, high ingress protection rate, which is the basic characteristic of the terminal, means failure free operation under harsh industrial conditions.
Working Modes and Functions
The terminal has been equipped with numerous working modes: Parts Counting, +/- Control, Percent weighing, Totalizing, Peak Hold and Animal Weighing.
Additionally, it enables defining of simple printouts in accordance with GLP procedures, and features weighing and ALIBI memory with export option, real time clock, and extensive tare functions.
Communication Interfaces and Exchange of Information with External Devices
Possibility to furnish the terminal with additional interfaces, makes its adaptation to customer requirements easy. This facilitates especially communication with stack lights and external buttons controlling scale functions (zeroing, taring and printout), and integration with unsophisticated automation systems.
The terminal allows for communication with external devices such as receipt printer, additional display, computer or USB flash drive.
Battery as an Optional Power Source
Use of the optional battery enables the PUE H315 terminal to operate even when there is either no or unstable power supply.
Datasheet
OIML Class

III

 

Maximum quantity of divisions from converter

838 860 ×10

 

Maximum quantity of verification units

6000 e

 

Minimum volatge per verification unit

0,4 µV

 

Maximum voltage per verification unit

3,25 µV

 

Minimum load cell impedance

50 Ω

 

Maximum load cell impedance

1200 Ω

 

Load cell excitation voltage

5V DC

 

Maximum increase of signal

39 mV

 

Connection of load cells

4 or 6 wires + shield

 

Display

LCD (backlit)

 

Device dimensions

208×145×80

 mm

Packaging dimensions

300×250×130

 mm

Net weight

1,9

 kg

Gross weight

2,2

 kg

Protection class

IP 66 / 67 / 69

 

Keypad

microswitch

 

Housing

Stainless steel

 

Communication interface

RS232, USB

 

Optional interfaces

RS232 or RS485 or 4IN/4OUT or Ethernet or analog output 4-20 mA

 

Power supply

100 – 240 V AC 50/60 Hz

 

Optional power supply

internal rechargeable battery

 

Operation time on batteries

max 7h

 

Operating temperature

-10 – +40

 °C

Storage temperature

-10 – +50

 °C

Relative humidity

10% – 80% RH no condensation

 

Number of buttons

5

 

Multiple range

1 or 2 ranges

 

Additional LCD display

WD-4/1 (option)

 

CE
2 years warranty
Videos
PUE H315 – Robust Weighing Terminal For the Toughest Industrial Applications
Complete Solutions for Mass Measurement in Pharma Industry
Functions
Plus/Minus Control

Plus/Minus Control

Control of sample's mass carried out with reference to specified MIN and MAX thresholds. The weight is considered to be correct if it is comprised within threshold values. A graphic visualisation of weighing result is displayed in a form of a bar graph.
Percent Weighing

Percent Weighing

Percent Weighing function is used for comparision of measured products with mass standard. Mass of a mass standard may be a numeric value taken from a database or it may be determined through a measurement process. Each measured product is compared to mass standard, mass of which is presumed as a model 100% ideal mass. For products weighing less than the mass standard, obtained results are lower than 100%, for products weighing more, the obtained results are greatly  exceeded.
Totalizing

Totalizing

Function adding new mass value to already obtained one. This allows to determine mass content of the mixture, being a composition of number of different consistence components. Totalizing is limited by maximum capacity parameter.
Parts counting

Parts counting

Function using mass measurement for determination of  measured items quantity. Mass of a single item is required for this process. It may be either estimated through weighment or taken from a database. For items counting the following algorithm is used: all items mass / single item mass = quantity. Function operation is supperted by a mechanism of Automatic Correction of Accuracy. This allows to update single item mass in course of the process. To a certain extend Automatic Correction of Accuracy eliminates error which may be a result of different mass values of seemingly alike single elements. For industry solutions items counting may be simultaneously carried out with checkweighing and dosing thus industry solutions feature audio signalling base informing that specified number of items has been weighed. It is possible to apply weighing systems using few platfroms of different MAX capacities and different accuracies.
Internal battery

Internal battery

Internal and rechargeable battery of SLA 6 V type (sealed lead acid) enables device operation without connecting the device to the mains (9h operation). The weighing instrument controls battery status and displays a respective pictogram on the screen.
Peak hold

Peak hold

Function registering the greatest temporary indication occurring in course of the weighing process. It is most often used in medical scales in order to hold the measurement indication.
GLP Procedures

GLP Procedures

Diagnostic function allowing to objectively document performed measurements. GLP procedures may be either presented in a short report form or extended one.
Animal weighing

Animal weighing

Process of mass determination for a product which may unwillingly reposition within the weighing pan. Mass determination in such cases requires much longer period of time when compared to typical weighing process. It is the user who defines period of time needed for control of measured product mass. The user can thus optimize the function depending on the measured product characteristics.
ALIBI Memory

ALIBI Memory

"ALIBI" memory enables saving and storing up to 100000 measurements.  Measurements are saved automatically upon each pressing of the key. There is no need for any additional operations or changing settings.
The following data related with the measurements is saved: measurement date; measurement time; result (mass); tare value; operator carrying out the measurement (logged in); product name.
The software saves the measurement in a so called loop, i.e. when the measurement no. 100001 is saved, the measurement 1 gets automatically deleted from the memory.
Measurements saved to balance memory cannot be deleted.
You can preview and print out the data saved to the ALIBI database.
Documentation
Data Sheet Data Sheet
Data Sheet

View
View
Download
Download

Choose more product:
View View DownloadDownload
User Manual - CBCP 01
User Manual - CBCP 01
View
View
Download
Download
(0.30 MB)
User Manual - PUE H315
User Manual - PUE H315
View
View
Download
Download
(1.40 MB)
Software Manual - PUE H315
Software Manual - PUE H315
View
View
Download
Download
(1.38 MB)
Conformity Declarations
Conformity Declarations
View
View
Download
Download
(0.04 MB)
Quick start
Quick start
View
View
Download
Download
(1.63 MB)
H315 Indicator
H315 Indicator
View
View
Download
Download
(1.10 MB)
Terminals and Platforms
Terminals and Platforms
View
View
Download
Download
(3.70 MB)
Accessories

Newsletter

Subscribe to the newsletter if you would like to receive RADWAG news.

View more
Radwag Balances and Scales
Torunska 5
26-600 Radom
Poland
tel.: +48 48 386 60 00
e-mail: export@radwag.com
TIN: PL7960000327
Vimeo Radwag YouTube Radwag Facebook Radwag LinkedIn Radwag
© 2024 RADWAG Balances and Scales. All rights reserved.

Select language

×
Change language AlbanianAlbanian
Change language DanishDanish
Change language NederlandseNederlandse
Change language EstonianEstonian
Change language FinnishFinnish
Change language HungarianHungarian
Change language IcelandicIcelandic
Change language KazakhKazakh
Change language LatvianLatvian
Change language LithuanianLithuanian
Change language MacedonianMacedonian
Change language NorwegianNorwegian
Change language PortuguesePortuguese
Change language RomanianRomanian
Change language RussianRussian
Change language SlovakSlovak
Change language SlovenianSlovenian
Change language SwedishSwedish
Change language UkrainianUkrainian
Change language SerbianSerbian
Change language MontenegrinMontenegrin
Change language page on Deutsch Deutsch
Change language page on English English
Change language page on Español Español
Change language page on Français Français
Change language page on Italiano Italiano
Change language page on Polski Polski
Change language page on Türkiye Türkiye
Česky
Português (Brasil)
Change website to USA USA
Change language page on 中文 中文
Presentations Presentations Presentations
Subscribe Subscribe Subscribe
Radwag in Facebook Radwag in Facebook Facebook
Radwag in YouTube Radwag in YouTube Youtube
Radwag in Vimeo Radwag in Vimeo Vimeo
Radwag in LinkedIn Radwag in LinkedIn LinkedIn
Webinars Radwag Webinars Radwag Webinars
close
E-mail:
Company name:
Name:
I consent to the processing of my personal data for marketing purposes by Radwag Wagi Elektroniczne Witold Lewandowski.
I consent to receive marketing and product-related messages by electronic means from Radwag Wagi Elektroniczne Witold Lewandowski.
I have read the Privacy Policy of RADWAG Wagi Elektroniczne Witold Lewandowski.
lock_openI want to access the files
close
Slide to go back ↩