Caratteristiche generali
The Housing and the Display
The housing is made of durable ABS plastic. The terminal has been equipped with 5’’ colour display ensuring perfect readability, and 22-key membrane keypad featuring programmable function keys. The terminal offers customized menu, with this all your personal needs can be met which makes operation even more intuitive and simple.
 
Battery as an Optional Power Source
Use of the optional battery enables the PUE C32 terminal to operate even when there is either no or unstable power supply.
 
Communication Interfaces
Standard terminal has been equipped with RS 232, USB-A, USB-B, 4×IN, 4×OUT and Ethernet interfaces which facilitate both cooperation with peripherals such as printer or computer and data exchange using USB drives.
Learn that on your special request the PUE C32 can be equipped with wireless communication module allowing the terminal to connect with wireless networks.
 
Data Management
Information system of PUE C32 terminals has been based on ALIBI memory and the following databases: users, products, weighings, packagings, formulations, customers. Data exchange within the system is bidirectional and it is carried out via USB interface. The terminals enable import and export of databases which is done using USB flash drives.
 
ALIBI Memory
ALIBI memory provides data safety and allows saving up to 500 thousand weighing records.This guaranties continuous storing of data over a long period of time.
Specifiche
Display

5” graphic colour

 

Device dimensions

206×140×71

 mm

Dimensioni del pacco

300×250×130

 mm

Peso netto

0,7

 kg

Peso lordo

0,94

 kg

Punteggio IP

IP 43

 

Struttura

ABS plastic

 

Interfaccia

2×RS232, USB-A, USB-B, Ethernet, 4 IN / 4 OUT (digital), Wi-Fi®

 

Alimentatore

100 – 240 V AC 50/60 Hz

 

Alimentatore opzionale

internal rechargeable battery

 

Tempo operativo delle batterie

operation time up to 5 h

 

Quantita massima di unita verificate

6000 e

 

Minimum volatge per verification unit

0,4 µV

 

Maximum voltage per verification unit

3,25 µV

 

Impedenza della cella al carico minimo

50 Ω

 

Maximum load cell impedance

1200 Ω

 

Tensione di eccitazione della cella di carico

5V DC

 

Incremento massimo del segnale

39 mV

 

Connessione di celle di carico

4 or 6 wires + shield

 

Ambiente di lavoro

-10 – +40

 °C

Multi scala

YES

 

Numero massimo di piattaforme

1

 

CE
Garanzia 2 anni
* - esecuzione opzionale
Video
Complete Solutions for Mass Measurement in Pharma Industry
Funzioni
Labelling

Labelling

Marking products with the right symbols contributes to quick and reliable identification. The balance/scale usually transfers product mass or product quantity to the label printer. The transferred value is printed with the following information: bar code, pictogram, content, address etc. In laboratory the labelling is performed in a semi-automatic mode, for industry in an automatic one (dynamic scales).
Percent Weighing

Percent Weighing

Percent Weighing function is used for comparision of measured products with mass standard. Mass of a mass standard may be a numeric value taken from a database or it may be determined through a measurement process. Each measured product is compared to mass standard, mass of which is presumed as a model 100% ideal mass. For products weighing less than the mass standard, obtained results are lower than 100%, for products weighing more, the obtained results are greatly  exceeded.
Totalizing

Totalizing

Function adding new mass value to already obtained one. This allows to determine mass content of the mixture, being a composition of number of different consistence components. Totalizing is limited by maximum capacity parameter.
Parts counting

Parts counting

Function using mass measurement for determination of  measured items quantity. Mass of a single item is required for this process. It may be either estimated through weighment or taken from a database. For items counting the following algorithm is used: all items mass / single item mass = quantity. Function operation is supperted by a mechanism of Automatic Correction of Accuracy. This allows to update single item mass in course of the process. To a certain extend Automatic Correction of Accuracy eliminates error which may be a result of different mass values of seemingly alike single elements. For industry solutions items counting may be simultaneously carried out with checkweighing and dosing thus industry solutions feature audio signalling base informing that specified number of items has been weighed. It is possible to apply weighing systems using few platfroms of different MAX capacities and different accuracies.
Statistics

Statistics

Statistiscs function registers and analyses performed measurements. This supplies the user withthe following information: Max and Min standard deviation, average value, variance, range et.
Checkweighing

Checkweighing

Checkweighing function is used for checking whether the measured sample mass is within the predefined threshold values, Low [LO] and Hgh [HI]. The thresholds are given in [g] and [kg] units. Current state of a sample being measured is signalled by means of pictorgams located on a display for laboratory balances, for industrial scales Stackligt System is used. This visual +/- inspection is in operation during segregation, control or packing process of products for which mass has bees determined with a specifaied tolerance, eg. 12860 g 961
IR sensors

IR sensors

Programmable function supporting the weighing process through control of the following options: sliding weighing chamber doors, printout, zeroing, tarring etc. Especially appreciated wherever preventing the balance from soiling is important.
GLP Procedures

GLP Procedures

Diagnostic function allowing to objectively document performed measurements. GLP procedures may be either presented in a short report form or extended one.
Replaceable unit

Replaceable unit

Replaceable units.
ALIBI Memory

ALIBI Memory

"ALIBI" memory enables saving and storing up to 100000 measurements.  Measurements are saved automatically upon each pressing of the key. There is no need for any additional operations or changing settings.
The following data related with the measurements is saved: measurement date; measurement time; result (mass); tare value; operator carrying out the measurement (logged in); product name.
The software saves the measurement in a so called loop, i.e. when the measurement no. 100001 is saved, the measurement 1 gets automatically deleted from the memory.
Measurements saved to balance memory cannot be deleted.
You can preview and print out the data saved to the ALIBI database.
Documentazione
Data Sheet Data Sheet
Data Sheet

Vista
Vista
Salva
Salva

Choose more product:
Vista Vista SalvaSalva
Manuali - CBCP 02
Manuali - CBCP 02
Vista
Vista
Salva
Salva
(0.25 MB)
Software Manual
Software Manual
Vista
Vista
Salva
Salva
(3.45 MB)
Software Manual - Appendices 02
Software Manual - Appendices 02
Vista
Vista
Salva
Salva
(0.99 MB)
Start up Guide
Start up Guide
Vista
Vista
Salva
Salva
(3.15 MB)
User Manual - PUE C32
User Manual - PUE C32
Vista
Vista
Salva
Salva
(1.94 MB)
Software Manual
Software Manual
Vista
Vista
Salva
Salva
(0.93 MB)
Conformity-Declaration
Conformity-Declaration
Vista
Vista
Salva
Salva
(0.12 MB)
PUE C32 Terminal
PUE C32 Terminal
Vista
Vista
Salva
Salva
(3.16 MB)
Terminals and Platforms
Terminals and Platforms
Vista
Vista
Salva
Salva
(3.70 MB)
Software
Drivers

LabVIEW (3.05 MB)

RADWAG USB DRIVER 1.6.2 (1.25 MB)

Accessori

Newsletter

If you wish to receive the latest news about RADWAG products and services, sign up for the newsletter.

More
Radwag bilance e sistemi di pesatura
Torunska 5
26-600 Radom
Poland
tel.: +48 48 386 60 00
e-mail: export@radwag.com
TIN: PL7960000327
Vimeo Radwag YouTube Radwag Facebook Radwag LinkedIn Radwag
© 2024 Radwag bilance e sistemi di pesatura. Diritti riservati

selezionare

×
Change language AlbanianAlbanian
Change language DanishDanish
Change language NederlandseNederlandse
Change language EstonianEstonian
Change language FinnishFinnish
Change language HungarianHungarian
Change language IcelandicIcelandic
Change language KazakhKazakh
Change language LatvianLatvian
Change language LithuanianLithuanian
Change language MacedonianMacedonian
Change language NorwegianNorwegian
Change language PortuguesePortuguese
Change language RomanianRomanian
Change language RussianRussian
Change language SlovakSlovak
Change language SlovenianSlovenian
Change language SwedishSwedish
Change language UkrainianUkrainian
Change language SerbianSerbian
Change language MontenegrinMontenegrin
Change language page on Deutsch Deutsch
Change language page on English English
Change language page on Español Español
Change language page on Français Français
Change language page on Polski Polski
Change language page on Türkiye Türkiye
Česky
Português (Brasil)
Change website to USA USA
Change language page on 中文 中文
Presentations Presentations Presentations
Subscribe Subscribe Subscribe
Radwag in Facebook Radwag in Facebook Facebook
Radwag in YouTube Radwag in YouTube Youtube
Radwag in Vimeo Radwag in Vimeo Vimeo
Radwag in LinkedIn Radwag in LinkedIn LinkedIn
Webinars Radwag Webinars Radwag Webinars
close
E-mail
nome azienda:
Nome:
I consent to the processing of my personal data for marketing purposes by Radwag Wagi Elektroniczne Witold Lewandowski.
I consent to receive marketing and product-related messages by electronic means from Radwag Wagi Elektroniczne Witold Lewandowski.
I have read the Privacy Policy of RADWAG Wagi Elektroniczne Witold Lewandowski.
lock_openI want to access the files
close
Slide to go back ↩