Balanza de precisión WLC 12/F1/K

Balanza de precisión WLC 12/F1/K - RADWAG Balanzas Electrónicas
This image is for reference only.

Código de producto: WL-206-0075
Preguntar sobre producto

Descripción

Maxima capacidad: 12kg
Legibilidad [d]: 0,2g

Las balanzas WLC  son dedicadas al pesaje muy rápido y exacto en el ambiente de laboratorio e industrial. Pueden funcionar en lugares alejados de una fuente de alimentación eléctrica ya que son equipadas de un acumulador interno (230V) y un interfaz RS 232 com estandár. Tiene el platillo de acero inoxidable y pantalla LCD retroiluminada que garantiza la mayor legibilidad del resultado de pesaje.
Las balanzas WLC permiten realizar mediciones fuera de la plataforma de pesaje (pesaje por debajo del plato) – la muestra puede ser colgada por debajo de la balanza. Ésta es una alternativa para las muestras de grandes tamaños y de formas irregulares también para el pesaje de objetos que emiten su campo magnético.

Funciones

Plus/Minus Control

Plus/Minus Control

Control of sample's mass carried out with reference to specified MIN and MAX thresholds. The weight is considered to be correct if it is comprised within threshold values. A graphic visualisation of weighing result is displayed in a form of a bar graph.
Percent Weighing

Percent Weighing

Percent Weighing function is used for comparision of measured products with mass standard. Mass of a mass standard may be a numeric value taken from a database or it may be determined through a measurement process. Each measured product is compared to mass standard, mass of which is presumed as a model 100% ideal mass. For products weighing less than the mass standard, obtained results are lower than 100%, for products weighing more, the obtained results are greatly  exceeded.
Totalizing

Totalizing

Function adding new mass value to already obtained one. This allows to determine mass content of the mixture, being a composition of number of different consistence components. Totalizing is limited by maximum capacity parameter.
Parts counting

Parts counting

Function using mass measurement for determination of  measured items quantity. Mass of a single item is required for this process. It may be either estimated through weighment or taken from a database. For items counting the following algorithm is used: all items mass / single item mass = quantity. Function operation is supperted by a mechanism of Automatic Correction of Accuracy. This allows to update single item mass in course of the process. To a certain extend Automatic Correction of Accuracy eliminates error which may be a result of different mass values of seemingly alike single elements. For industry solutions items counting may be simultaneously carried out with checkweighing and dosing thus industry solutions feature audio signalling base informing that specified number of items has been weighed. It is possible to apply weighing systems using few platfroms of different MAX capacities and different accuracies.
Internal battery

Internal battery

Internal and rechargeable battery of SLA 6 V type (sealed lead acid) enables device operation without connecting the device to the mains (9h operation). The weighing instrument controls battery status and displays a respective pictogram on the screen.
Peak hold

Peak hold

Function registering the greatest temporary indication occurring in course of the weighing process. It is most often used in medical scales in order to hold the measurement indication.
Newton unit measurement

Newton unit measurement

Function allowing to perform the measurement in Newton unit, it may be used for processes aiming to determine force resulting in the sample damage.

Datos tecnicos

Maxima capacidad

12

 kg

Legibilidad [d]

0,2

 g

Rango de tara

-12

 kg

Repetibilidad

0,2

 g

Linealidad

±0,6

 g

Tiempo de estabilización

3

 s

Calibración

externa

 

Pantalla

LCD (con retroiluminación)

 

Control de protección

IP 43

 

Communication interface

RS232

 

Alimentacion

100 ÷ 240 V AC 50 / 60 Hz + bateria

 

Horas de trabajo con baterias

10 horas (el tiempo promedio)

 

Temperatura de trabajo

+15 ÷ +30

 °C

Humedad relativa de aire

10% ÷ 85% RH sin condensación

 

Dimensión de platillo

300×300

 mm

Dimensiones de embalaje

570×390×170

 mm

Masa neto

5,2

 kg

Masa bruto

6

 kg

Documentación

Documentación técnica
Publicaciones y materiales didácticos

User Manual
(0.91 MB) EN

Save
See the publication

Folleto de producto
(0.93 MB)

Save
See the publication

Conformity Declaration
(0.04 MB) EN

Save
See the publication

Programas

Drivers

LabVIEW (3.05 MB)

Software

R-Lab (149.39 MB)
Descargar la versión del software con un límite de 1.000 pesajes

Accesorios

Mesas antivibratil de granito
R-LAB
RAD KEY
Controlador LabVIEW “Radwag Balances & Scales”
Impresoras de recibos
Cables RS 232 (Bascula a Impresora EPSON)
Cables RS 232, RS 485
Cables de corriente desde mechero de automóvil
Soportes, brazos
Salidas del bucle de corriente
Convertidor RS232 a Ethernet
Convertidor RS232 a RS485
Pantallas

RADWAG Balanzas Electrónicas

Torunska 5
26-600 Radom
Poland
tel.: +48 48 386 63 03
e-mail: export@radwag.com
TIN: PL7960000327
Vimeo Radwag YouTube Radwag Facebook Radwag
© 2019 RADWAG Balances and Scales. All rights reserved.

See our movies
RADWAG

Radwag WEBINARS