Scales for EX Areas - Radwag Balances And Scales
Radwag Balances and Scales - Advanced Weighing Technologies
Selected language English
HX5.EX-1 C 1 Load Cell Platform ScalesHX5.EX-1 H Waterproof Platform ScalesHX5.EX-1.4 C Platform ScalesHX5.EX-1.4 H/Z Stainless Steel Platform Scales, Pit VersionHX5.EX-1.4P C Pallet ScalesHX5.EX-1.4P2 C Beam ScalesHRP EX Platforms High CapacityHX5.EX-1 HR Waterproof Platform ScalesHX5.EX-1.4 H Stainless Steel Platform ScalesHX5.EX-1.4N Stainless Steel Ramp ScalesHX5.EX-1.4P H Stainless Steel Pallet ScalesHX5.EX-1.4P2 H Stainless Steel Beam ScalesStainless Steel HRP EX.H PlatformsPUE HX5.EX IndicatorIntrinsically Safe Power Supply Intended for EX ScaleCommunication Modules
Hazardous Area Endangered with Gas Explosion Readability [d]: 0,1g - 2000g
Maximum capacity [Max]: 1.5kg - 6000kg
Load Cell Platform Scales
HX5.EX-1 C 1

Readability [d]: 0,5g - 100g
Maximum capacity [Max]: 1.5kg - 300kg
View Ask a question
Waterproof Platform Scales
HX5.EX-1 H

Readability [d]: 0,5g - 100g
Maximum capacity [Max]: 1.5kg - 300kg
View Ask a question
Platform Scales
HX5.EX-1.4 C

Readability [d]: 20g - 2000g
Maximum capacity [Max]: 60kg - 6000kg
View Ask a question
Stainless Steel Platform Scales, Pit Version
HX5.EX-1.4 H/Z

Readability [d]: 20g - 2000g
Maximum capacity [Max]: 60kg - 6000kg
View Ask a question
Pallet Scales
HX5.EX-1.4P C

Readability [d]: 200g - 1000g
Maximum capacity [Max]: 600kg - 3000kg
View Ask a question
Beam Scales
HX5.EX-1.4P2 C

Readability [d]: 200g - 2000g
Maximum capacity [Max]: 600kg - 6000kg
View Ask a question
Platforms High Capacity
HRP EX

Readability [d]: 0,1g - 20g
Maximum capacity [Max]: 16kg - 2000kg
View Ask a question
Hazardous Area Endangered with Gas and Dust Explosion Readability [d]: 0,1g - 2000g
Maximum capacity [Max]: 3kg - 6000kg
Waterproof Platform Scales
HX5.EX-1 HR

Readability [d]: 1g - 50g
Maximum capacity [Max]: 3kg - 150kg
View Ask a question
Stainless Steel Platform Scales
HX5.EX-1.4 H

Readability [d]: 20g - 2000g
Maximum capacity [Max]: 60kg - 6000kg
View Ask a question
Stainless Steel Ramp Scales
HX5.EX-1.4N

Readability [d]: 20g - 500g
Maximum capacity [Max]: 60kg - 1500kg
View Ask a question
Stainless Steel Pallet Scales
HX5.EX-1.4P H

Readability [d]: 200g - 1000g
Maximum capacity [Max]: 600kg - 3000kg
View Ask a question
Stainless Steel Beam Scales
HX5.EX-1.4P2 H

Readability [d]: 200g - 2000g
Maximum capacity [Max]: 600kg - 6000kg
View Ask a question
Stainless Steel
HRP EX.H Platforms

Readability [d]: 0,1g - 20g
Maximum capacity [Max]: 16kg - 2000kg
View Ask a question
PUE HX5.EX Indicator See all models
Intrinsically Safe Power Supply Intended for EX Scale See all models
Communication Modules See all models
More information » keyboard_arrow_down
Measurement of mass in areas endangered with explosion requires use of a professional device ensuring weighing accuracy and precision but most of all operation safety. RADWAG manufactures reliable instruments to-be-operated in hazardous areas where there is a risk of explosion of gases,, and in hazardous areas endangered with explosion of gases and dusts. Each of these two groups comprises widely applied 1-load-cell scales, and 4-load-cell scales with large-size platforms.

RADWAG EX scales are controlled via a modern weighing terminal, the PUE HX5.EX, certified with ATEX approval. The device is intended to be a component of industrial load-cell scales that can be operated in production areas endangered with explosion, classified as zones 1, 21, 2, 22.

The PUE HX5.EX terminal must be powered using a certified intrinsically safe PM01 power supply manufactured by RADWAG. Depending on the needs, the PM01.EX can be connected to the voltage source placed either in hazardous or safe area. RADWAG product range includes a communication module, the IM01.EX, with use of which it is possible to expand the quantity of terminal’s communication interfaces. The module is installed outside the hazardous area, and connected to the indicator using an intrinsically safe interface.
Classification of hazardous areas and explosion probability » keyboard_arrow_down
RADWAG product range offers weighing instruments intended for operation in hazardous areas classified as zones 1, 2, 21 and 22. The equipment meets the highest safety standards. Its mechanical design prevents initiation of explosive mixtures ignition. The user may choose from various weighing platforms offered in wide range of dimensions and maximum capacities. This combined with excellent metrological parameters enables easy selection of an instrument that meets the most demanding requirements.

The classification of hazardous areas is included in Annex I of the Directive 1999/92/EC ATEX137 of 16 December 1999, ‘On minimum requirements for improving the safety and health protection of workers potentially at risk from explosive atmospheres’.

The table presents classification of hazardous areas and explosion probability.

Explosive atmosphere caused by mixture of air and: Hazardous areas classification Explosion probability
gas, liquid and vapours (Zone G) 0 constant explosion risk lasting for a long period of time
1 occasional explosion risk
2 no explosion risk during regular work, shall any occur it lasts for a short period of time
flammable dust (Zone D) 20 constant explosion risk lasting for a long period of time
21 occasional explosion risk
22 no explosion risk during regular work, shall any occur it lasts for a short period of time
Radwag Balances and Scales
Torunska 5
26-600 Radom
Poland
tel.: +48 48 386 60 00
e-mail: export@radwag.com
TIN: PL7960000327
Vimeo Radwag YouTube Radwag Facebook Radwag LinkedIn Radwag
© 2021 RADWAG Balances and Scales. All rights reserved.

Select language

×
Change language AlbanianAlbanian
Change language DanishDanish
Change language NederlandseNederlandse
Change language EstonianEstonian
Change language FinnishFinnish
Change language HungarianHungarian
Change language IcelandicIcelandic
Change language KazakhKazakh
Change language LatvianLatvian
Change language LithuanianLithuanian
Change language MacedonianMacedonian
Change language NorwegianNorwegian
Change language PortuguesePortuguese
Change language RomanianRomanian
Change language RussianRussian
Change language SlovakSlovak
Change language SlovenianSlovenian
Change language SwedishSwedish
Change language UkrainianUkrainian
Change language SerbianSerbian
Change language MontenegrinMontenegrin
Change language page on Deutsch Deutsch
Change language page on Español Español
Change language page on Français Français
Change language page on Italiano Italiano
Change language page on Polski Polski
Change language page on Türkiye Türkiye
Česky
Change website to USA USA
Change language page on 中文 中文
Subscribe
Facebook
Youtube
Vimeo
LinkedIn
Webinars
close