Beschreibung

Wägebereich [Max]: 300kg
Ziffernschritt [d]: 0,1kg

Die Messung der Masse mit Hilfe eines 4-Sensor-Systems garantiert die Zuverlässigkeit des Wägens bei einer belieben Platzierung des Wägeguts auf der Plattform.

Die Plattformwaage mit vier Sensoren wird aus pulverbeschichteten Stahl und die Oberfläche der Plattform aus Riffelblech hergestellt. Die

Waage

ist mit dem PUE C315-Wägeterminal mit einem 3 Meter langem Kabel und einem hinterleuchteten LCD-Display ausgestattet. Die

Waage

ist für die Grubeninstallation vorbereitet. Eine solche Installationsart ermöglicht das Durchfahren des Wägeguts über die Plattform ohne Auffahren.

Das Verbindungskabel zwischen dem Wägeterminal und der Plattform hat eine Länge von 3 m.

Funktionen

Plus/Minus Control

Plus/Minus Control

Control of sample's mass carried out with reference to specified MIN and MAX thresholds. The weight is considered to be correct if it is comprised within threshold values. A graphic visualisation of weighing result is displayed in a form of a bar graph.
Percent Weighing

Percent Weighing

Percent Weighing function is used for comparision of measured products with mass standard. Mass of a mass standard may be a numeric value taken from a database or it may be determined through a measurement process. Each measured product is compared to mass standard, mass of which is presumed as a model 100% ideal mass. For products weighing less than the mass standard, obtained results are lower than 100%, for products weighing more, the obtained results are greatly  exceeded.
Totalizing

Totalizing

Function adding new mass value to already obtained one. This allows to determine mass content of the mixture, being a composition of number of different consistence components. Totalizing is limited by maximum capacity parameter.
Parts counting

Parts counting

Function using mass measurement for determination of  measured items quantity. Mass of a single item is required for this process. It may be either estimated through weighment or taken from a database. For items counting the following algorithm is used: all items mass / single item mass = quantity. Function operation is supperted by a mechanism of Automatic Correction of Accuracy. This allows to update single item mass in course of the process. To a certain extend Automatic Correction of Accuracy eliminates error which may be a result of different mass values of seemingly alike single elements. For industry solutions items counting may be simultaneously carried out with checkweighing and dosing thus industry solutions feature audio signalling base informing that specified number of items has been weighed. It is possible to apply weighing systems using few platfroms of different MAX capacities and different accuracies.
Internal battery

Internal battery

Internal and rechargeable battery of SLA 6 V type (sealed lead acid) enables device operation without connecting the device to the mains (9h operation). The weighing instrument controls battery status and displays a respective pictogram on the screen.
Peak hold

Peak hold

Function registering the greatest temporary indication occurring in course of the weighing process. It is most often used in medical scales in order to hold the measurement indication.
GLP Procedures

GLP Procedures

Diagnostic function allowing to objectively document performed measurements. GLP procedures may be either presented in a short report form or extended one.
Animal weighing

Animal weighing

Process of mass determination for a product which may unwillingly reposition within the weighing pan. Mass determination in such cases requires much longer period of time when compared to typical weighing process. It is the user who defines period of time needed for control of measured product mass. The user can thus optimize the function depending on the measured product characteristics.
ALIBI Memory

ALIBI Memory

"ALIBI" memory enables saving and storing up to 100000 measurements.  Measurements are saved automatically upon each pressing of the key. There is no need for any additional operations or changing settings.
The following data related with the measurements is saved: measurement date; measurement time; result (mass); tare value; operator carrying out the measurement (logged in); product name.
The software saves the measurement in a so called loop, i.e. when the measurement no. 100001 is saved, the measurement 1 gets automatically deleted from the memory.
Measurements saved to balance memory cannot be deleted.
You can preview and print out the data saved to the ALIBI database.

Technische Daten

Wägebereich [Max]

300

 kg

Min. Belastung

2

 kg

Ziffernschritt [d]

0,1

 kg

Tarierbereich

-300

 kg

OIML-Klasse

III

 

Display

LCD (hinterleuchtet)

 

Schutzart

IP 65 Konstruktion, IP 43 Messgerät

 

RS-232-Schnittstelle

1× standard, 1× optional

 

Wi-Fi® Schnittstelle

1× standard

 

Stromversorgung

100 ÷ 240 V AC 50 / 60 Hz und Akkus

 

Akku-Betriebszeit

max 8h

 

Umgebungstemperatur

-10 ÷ +40

 °C

Relative Luftfeuchtigkeit

10% ÷ 85% RH ohne Kondensation

 

Waagschale

1200×1200

 mm

Höhe Wägeplattform

120 ±10

 mm

Gewicht der Waage mit Messgerät

110

 kg

Dokumentation

Technische Dokumentation
Publikationen und Lerninhalte
User Manual
(0.98 MB) EN
Save See the publication
Manuals
(0.30 MB) EN
Save See the publication
Data Sheet
(1.08 MB) EN
Save See the publication
Conformity Declaration
(0.04 MB) EN
Save See the publication
C315 Platform Scales
(2.13 MB) EN
Save See the publication
Measuring_instruments_in_industry
(0.05 MB) EN
Save See the publication

Zubehör

Waagen-Editor 2.0
RW Tool
R-LAB
RAD KEY
LabVIEW Driver
Thermische Drucker
Auffahrten
Anschlusskabel für Zigarettenanzünder
Kabel RS 232 (Waage – Drucker EPSON)
Kabel RS 232RS 485
Stative, Ausleger
Ausgänge der Stromschnittstelle
Konverter RS232 – Ethernet
Konverter RS232 – RS485
Displays

RADWAG Elektronische Waagen

Torunska 5
26-600 Radom
Polen
Tel.: +48 48 386 60 00
E-mail: export@radwag.com
VAT Nr.: 796-000-03-27
Vimeo Radwag YouTube Radwag Facebook Radwag LinkedIn Radwag
© 2019 RADWAG Elektronische Waagen. Alle Rechte vorbehalten.

Watch more
RADWAG videos


movie
Radwag WEBINARS