Terminal for Industry
The PUE C315 terminal is intended for fast and precise presentation of mass measurement result. Taring available for the whole weighing range allows to swiftly and precisely determine net mass of weighed loads. An ABS plastic housing ensures durability and lightness of the construction.

Uncomplicated Operation and Clear Presentation of Indications
A clear 6-digit LCD display with backlight and pictograms provides clearly visible measurement result. Easy operation enables fast and reliable measurements to be carried out even by an inexperienced operator.

Mobility due to an Internal Battery
In addition to power supply from the mains, PUE C315 terminal is equipped with internal battery that enables several hours long mobile operation.

Versatility of Use
Various possibilities of fastening of the PUE C315 terminal to the weighing platform enable selecting appropriate solution for different places of operation. The terminal can be mounted next to the platform, on a post or using cable.

ALIBI Memory
Internal ALIBI memory guarantees safety and automatic record of measurements copies, it also offers possibility to preview, copy and archive data.
 
Teknik Veriler
OIML sınıfı

III

 

Dönüştürücüden maksimum bölüm sayısı

838 860 ×10

 

Maximum quantity of verification units

6000 e

 

Doğrulama birimi başına minimum voltaj

0,4 µV

 

Doğrulama birimi başına maksimum voltaj

3,25 µV

 

Minimum load cell impedance

50 Ω

 

Yük hücresi maksimum empedansı

1200 Ω

 

Yük hücresi besleme gerilimi

5V DC

 

Maximum increase of signal

39 mV

 

Yük hücresi bağlantısı

4 veya 6 kablolar + kalkan

 

Display

LCD (aydınlatma ile)

 

Cihaz boyutları

181×136×60

 mm

Ambalaj boyutları

220×190×90

 mm

Net ağırlık

0,6

 kg

Brüt ağırlık

0,78

 kg

IP Sınıfı

IP 43

 

Klavye

Mikro şalter

 

Dava

ABS plastik

 

Haberleşme arayüzü

RS232

 

Opsiyonel arayüzler

RS232

 

Güç kaynağı

100 – 240 V AC 50/60 Hz

 

Maksimum güç tüketimi

5 W

 

Opsiyonel güç kaynağı

12 V DC + batarya

 

Batarya ile çalışma süresi

max 7h

 

Güç kaynağı

Çıkarılabilir güç adaptörü, batarya NiMH 6×AA

 

Düğme sayısı

5

 

Çok kademeli

1 veya 2 aralığı

 

İlave LCD display

WD-4/8 (opsiyon)

 

Çalıştırma sıcaklığı

-10 – +40

 °C

Depolama sıcaklığı

-10 – +50

 °C

Atmosferik nem

10% – 80% RH yoğunlaşma yok

 

CE
2 yıl garanti
Videolar
Complete Solutions for Mass Measurement in Pharma Industry
Fonksiyonlar
Plus/Minus Control

Plus/Minus Control

Control of sample's mass carried out with reference to specified MIN and MAX thresholds. The weight is considered to be correct if it is comprised within threshold values. A graphic visualisation of weighing result is displayed in a form of a bar graph.
Percent Weighing

Percent Weighing

Percent Weighing function is used for comparision of measured products with mass standard. Mass of a mass standard may be a numeric value taken from a database or it may be determined through a measurement process. Each measured product is compared to mass standard, mass of which is presumed as a model 100% ideal mass. For products weighing less than the mass standard, obtained results are lower than 100%, for products weighing more, the obtained results are greatly  exceeded.
Totalizing

Totalizing

Function adding new mass value to already obtained one. This allows to determine mass content of the mixture, being a composition of number of different consistence components. Totalizing is limited by maximum capacity parameter.
Parts counting

Parts counting

Function using mass measurement for determination of  measured items quantity. Mass of a single item is required for this process. It may be either estimated through weighment or taken from a database. For items counting the following algorithm is used: all items mass / single item mass = quantity. Function operation is supperted by a mechanism of Automatic Correction of Accuracy. This allows to update single item mass in course of the process. To a certain extend Automatic Correction of Accuracy eliminates error which may be a result of different mass values of seemingly alike single elements. For industry solutions items counting may be simultaneously carried out with checkweighing and dosing thus industry solutions feature audio signalling base informing that specified number of items has been weighed. It is possible to apply weighing systems using few platfroms of different MAX capacities and different accuracies.
Internal battery

Internal battery

Internal and rechargeable battery of SLA 6 V type (sealed lead acid) enables device operation without connecting the device to the mains (9h operation). The weighing instrument controls battery status and displays a respective pictogram on the screen.
Peak hold

Peak hold

Function registering the greatest temporary indication occurring in course of the weighing process. It is most often used in medical scales in order to hold the measurement indication.
GLP Procedures

GLP Procedures

Diagnostic function allowing to objectively document performed measurements. GLP procedures may be either presented in a short report form or extended one.
Animal weighing

Animal weighing

Process of mass determination for a product which may unwillingly reposition within the weighing pan. Mass determination in such cases requires much longer period of time when compared to typical weighing process. It is the user who defines period of time needed for control of measured product mass. The user can thus optimize the function depending on the measured product characteristics.
ALIBI Memory

ALIBI Memory

"ALIBI" memory enables saving and storing up to 100000 measurements.  Measurements are saved automatically upon each pressing of the key. There is no need for any additional operations or changing settings.
The following data related with the measurements is saved: measurement date; measurement time; result (mass); tare value; operator carrying out the measurement (logged in); product name.
The software saves the measurement in a so called loop, i.e. when the measurement no. 100001 is saved, the measurement 1 gets automatically deleted from the memory.
Measurements saved to balance memory cannot be deleted.
You can preview and print out the data saved to the ALIBI database.
Dokümantasyon
Data Sheet Data Sheet
Data Sheet

Bakış
Bakış
İndirme
İndirme

Choose more product:
Bakış Bakış İndirmeİndirme
User Manual - PUE C315
User Manual - PUE C315
Bakış
Bakış
İndirme
İndirme
(1.27 MB)
User Manual - CBCP 01
User Manual - CBCP 01
Bakış
Bakış
İndirme
İndirme
(0.30 MB)
Start up Guide
Start up Guide
Bakış
Bakış
İndirme
İndirme
(0.71 MB)
Software Manual - PUE C315
Software Manual - PUE C315
Bakış
Bakış
İndirme
İndirme
(1.39 MB)
Conformity Declaration
Conformity Declaration
Bakış
Bakış
İndirme
İndirme
(0.04 MB)
C315 Platform Scales
C315 Platform Scales
Bakış
Bakış
İndirme
İndirme
(2.13 MB)
Terminals and Platforms
Terminals and Platforms
Bakış
Bakış
İndirme
İndirme
(3.70 MB)
Aksesuarlar
R-LAB

Aksesuarlar

Radwag Terazileri İleri Tartım Teknolojileri
Torunska 5
26-600 Radom
Poland
tel.: +48 48 386 63 03
e-mail: export@radwag.com
TIN: PL7960000327
Vimeo Radwag YouTube Radwag Facebook Radwag LinkedIn Radwag
© 2024 RADWAG Balances and Scales. All rights reserved.

Bir dil seçin

×
Change language AlbanianAlbanian
Change language DanishDanish
Change language NederlandseNederlandse
Change language EstonianEstonian
Change language FinnishFinnish
Change language HungarianHungarian
Change language IcelandicIcelandic
Change language KazakhKazakh
Change language LatvianLatvian
Change language LithuanianLithuanian
Change language MacedonianMacedonian
Change language NorwegianNorwegian
Change language PortuguesePortuguese
Change language RomanianRomanian
Change language RussianRussian
Change language SlovakSlovak
Change language SlovenianSlovenian
Change language SwedishSwedish
Change language UkrainianUkrainian
Change language SerbianSerbian
Change language MontenegrinMontenegrin
Change language page on Deutsch Deutsch
Change language page on English English
Change language page on Español Español
Change language page on Français Français
Change language page on Italiano Italiano
Change language page on Polski Polski
Česky
Português (Brasil)
Change website to USA USA
Change language page on 中文 中文
Presentations Presentations Presentations
Subscribe Subscribe Subscribe
Radwag in Facebook Radwag in Facebook Facebook
Radwag in YouTube Radwag in YouTube Youtube
Radwag in Vimeo Radwag in Vimeo Vimeo
Radwag in LinkedIn Radwag in LinkedIn LinkedIn
Webinars Radwag Webinars Radwag Webinars
close
e-posta:
Firma ismi:
İsminiz:
I consent to the processing of my personal data for marketing purposes by Radwag Wagi Elektroniczne Witold Lewandowski.
I consent to receive marketing and product-related messages by electronic means from Radwag Wagi Elektroniczne Witold Lewandowski.
I have read the Privacy Policy of RADWAG Wagi Elektroniczne Witold Lewandowski.
lock_openI want to access the files
close
Slide to go back ↩