Basamento C315.4.3000.C8

Radwag Bilance e sistemi di pesatura
Selected language Italiano
Basamento C315.4.3000.C8
This image is for reference only.

Basamento C315.4.3000.C8

Codice prodotto: WP-230-0012
Modifica del modello (21)
done
Max: 3000kgd: 1kg

 1200×1200mm
expand_more
Max: 60kgd: 0,02kg

 800×800mm
Max: 60kgd: 0,02kg

 1000×1000mm
Max: 150kgd: 0,05kg

 800×800mm
Max: 150kgd: 0,05kg

 1000×1000mm
Max: 300kgd: 0,1kg

 800×800mm
Max: 300kgd: 0,1kg

 1000×1000mm
Max: 300kgd: 0,1kg

 1200×1200mm
Max: 600kgd: 0,2kg

 800×800mm
Max: 600kgd: 0,2kg

 1000×1000mm
Max: 600kgd: 0,2kg

 1200×1200mm
Max: 600kgd: 0,2kg

 1200×1500mm
Max: 600kgd: 0,2kg

 1500×1500mm
Max: 1500kgd: 0,5kg

 800×800mm
Max: 1500kgd: 0,5kg

 1000×1000mm
Max: 1500kgd: 0,5kg

 1200×1200mm
Max: 1500kgd: 0,5kg

 1200×1500mm
Max: 1500kgd: 0,5kg

 1500×1500mm
Max: 3000kgd: 1kg

 1200×1500mm
Max: 3000kgd: 1kg

 1500×1500mm
Max: 6000kgd: 2kg

 1500×1500mm
Portata massima [Max]: 3000 kg
Divisione [d]: 1 kg

close
Modifica del modello:
Basamento C315.4.60.C6
Basamento C315.4.60.C7
Basamento C315.4.150.C6
Basamento C315.4.150.C7
Basamento C315.4.300.C6
Basamento C315.4.300.C7
Basamento C315.4.300.C8
Basamento C315.4.600.C6
Basamento C315.4.600.C7
Basamento C315.4.600.C8
Basamento C315.4.600.C8/9
Basamento C315.4.600.C9
Basamento C315.4.1500.C6
Basamento C315.4.1500.C7
Basamento C315.4.1500.C8
Basamento C315.4.1500.C8/9
Basamento C315.4.1500.C9
Basamento C315.4.3000.C8
Basamento C315.4.3000.C8/9
Basamento C315.4.3000.C9
Basamento C315.4.6000.C9
Select all
Vista
Salva
Aggiungere a confrontare
Caratteristiche generali
 

Basamento C315.4.3000.C8

 
La pesata con l’appliazione a 4 celle di carico garantisce una misura precisa del peso a prescindere dal posizionamento
dello stesso sul piatto di pesata.
 

Serie C315.4

I basamenti serie C315.4 sono costruiti in acciaio verniciato a polvere. Il basamento comprende le 4 celle di carico connesse ad un terminalle serie PUE C315 caratterizzato dal display LCD retroilluminato e da 5 pulsanti funzione.

Il basamento e l’terminalle sono connessi via cavo permettendo il montaggio a muro dell’terminalle. I basamenti serie C315.4 sono disponibili anche in versione con apertura dellla base di pesata a compasso per consentire un semplice carico dei prodotti da pesare senza dover utilizzare rampe di accesso.

Questi basamenti sono disponibili anche in versione a doppia scala (con sovraprezzo). 
 
 
Stainless Steel in RADWAG products
Learn about the use and maintenance of stainless steel products:
Stainless Steel in RADWAG products. Standard and special applications
Specifiche
Portata massima [Max]

3000

 kg

Portata minima [Min]

20

 kg

Divisione [d]

1

 kg

Campo di tara

-3000

 kg

Massima leggibilità per bilance non verificate

200

 g

Classe OIML

III

 

Display

LCD (backlit)

 

Lunghezza del cavo

3

 m

Dimensione piatto

1200×1200

 mm

Altezza della piattaforma

120 ± 10

 mm

Dimensioni del pacco

1300×1300×500

 mm

Mass scala con indicatore

110

 kg

Punteggio IP

IP 65 construction, IP 43 terminal

 

Interfaccia

RS232

 

Interfacce opzionali

RS232

 

Alimentatore

100 – 240 V AC 50/60 Hz and battery

 

Massimo assorbimento elettrico

5 W

 

Tempo operativo delle batterie

max 8h

 

Ambiente di lavoro

-10 – +40

 °C

Umidità relativa

10% – 85% RH no condensation

 

Garanzia 2 anni
Verifica Additional fee
for verification
CE
Video
Complete Solutions for Mass Measurement in Pharma Industry
Funzioni
Plus/Minus Control

Plus/Minus Control

Control of sample's mass carried out with reference to specified MIN and MAX thresholds. The weight is considered to be correct if it is comprised within threshold values. A graphic visualisation of weighing result is displayed in a form of a bar graph.
Percent Weighing

Percent Weighing

Percent Weighing function is used for comparision of measured products with mass standard. Mass of a mass standard may be a numeric value taken from a database or it may be determined through a measurement process. Each measured product is compared to mass standard, mass of which is presumed as a model 100% ideal mass. For products weighing less than the mass standard, obtained results are lower than 100%, for products weighing more, the obtained results are greatly  exceeded.
Totalizing

Totalizing

Function adding new mass value to already obtained one. This allows to determine mass content of the mixture, being a composition of number of different consistence components. Totalizing is limited by maximum capacity parameter.
Parts counting

Parts counting

Function using mass measurement for determination of  measured items quantity. Mass of a single item is required for this process. It may be either estimated through weighment or taken from a database. For items counting the following algorithm is used: all items mass / single item mass = quantity. Function operation is supperted by a mechanism of Automatic Correction of Accuracy. This allows to update single item mass in course of the process. To a certain extend Automatic Correction of Accuracy eliminates error which may be a result of different mass values of seemingly alike single elements. For industry solutions items counting may be simultaneously carried out with checkweighing and dosing thus industry solutions feature audio signalling base informing that specified number of items has been weighed. It is possible to apply weighing systems using few platfroms of different MAX capacities and different accuracies.
Internal battery

Internal battery

Internal and rechargeable battery of SLA 6 V type (sealed lead acid) enables device operation without connecting the device to the mains (9h operation). The weighing instrument controls battery status and displays a respective pictogram on the screen.
Peak hold

Peak hold

Function registering the greatest temporary indication occurring in course of the weighing process. It is most often used in medical scales in order to hold the measurement indication.
GLP Procedures

GLP Procedures

Diagnostic function allowing to objectively document performed measurements. GLP procedures may be either presented in a short report form or extended one.
Animal weighing

Animal weighing

Process of mass determination for a product which may unwillingly reposition within the weighing pan. Mass determination in such cases requires much longer period of time when compared to typical weighing process. It is the user who defines period of time needed for control of measured product mass. The user can thus optimize the function depending on the measured product characteristics.
ALIBI Memory

ALIBI Memory

"ALIBI" memory enables saving and storing up to 100000 measurements.  Measurements are saved automatically upon each pressing of the key. There is no need for any additional operations or changing settings.
The following data related with the measurements is saved: measurement date; measurement time; result (mass); tare value; operator carrying out the measurement (logged in); product name.
The software saves the measurement in a so called loop, i.e. when the measurement no. 100001 is saved, the measurement 1 gets automatically deleted from the memory.
Measurements saved to balance memory cannot be deleted.
You can preview and print out the data saved to the ALIBI database.
Documentazione
Data Sheet Data Sheet
Data Sheet

Vista
Vista
Salva
Salva

Choose more product:
Vista Vista SalvaSalva
User Manual - CBCP 01
User Manual - CBCP 01
Vista
Vista
Salva
Salva
(0.30 MB)
Start up Guide
Start up Guide
Vista
Vista
Salva
Salva
(0.71 MB)
Quick start
Quick start
Vista
Vista
Salva
Salva
(2.47 MB)
Software Manual - PUE C315
Software Manual - PUE C315
Vista
Vista
Salva
Salva
(1.39 MB)
C315 Platform Scales
C315 Platform Scales
Vista
Vista
Salva
Salva
(2.13 MB)
Stainless Steel in RADWAG products. Standard and special applications
Stainless Steel in RADWAG products. Standard and special applications
Vista
Vista
Salva
Salva
(2.23 MB)
Pit installation frame
Pit installation frame
Vista
Vista
Salva
Salva
(0.13 MB)
Accessori

Newsletter

Subscribe to the newsletter if you would like to receive RADWAG news.

View more
Radwag bilance e sistemi di pesatura
Torunska 5
26-600 Radom
Poland
tel.: +48 48 386 60 00
e-mail: export@radwag.com
TIN: PL7960000327
Vimeo Radwag YouTube Radwag Facebook Radwag LinkedIn Radwag
© 2024 Radwag bilance e sistemi di pesatura. Diritti riservati

selezionare

×
Change language AlbanianAlbanian
Change language DanishDanish
Change language NederlandseNederlandse
Change language EstonianEstonian
Change language FinnishFinnish
Change language HungarianHungarian
Change language IcelandicIcelandic
Change language KazakhKazakh
Change language LatvianLatvian
Change language LithuanianLithuanian
Change language MacedonianMacedonian
Change language NorwegianNorwegian
Change language PortuguesePortuguese
Change language RomanianRomanian
Change language RussianRussian
Change language SlovakSlovak
Change language SlovenianSlovenian
Change language SwedishSwedish
Change language UkrainianUkrainian
Change language SerbianSerbian
Change language MontenegrinMontenegrin
Change language page on Deutsch Deutsch
Change language page on English English
Change language page on Español Español
Change language page on Français Français
Change language page on Polski Polski
Change language page on Türkiye Türkiye
Česky
Português (Brasil)
Change website to USA USA
Change language page on 中文 中文
Presentations Presentations Presentations
Subscribe Subscribe Subscribe
Radwag in Facebook Radwag in Facebook Facebook
Radwag in YouTube Radwag in YouTube Youtube
Radwag in Vimeo Radwag in Vimeo Vimeo
Radwag in LinkedIn Radwag in LinkedIn LinkedIn
Webinars Radwag Webinars Radwag Webinars
close
E-mail
nome azienda:
Nome:
I consent to the processing of my personal data for marketing purposes by Radwag Wagi Elektroniczne Witold Lewandowski.
I consent to receive marketing and product-related messages by electronic means from Radwag Wagi Elektroniczne Witold Lewandowski.
I have read the Privacy Policy of RADWAG Wagi Elektroniczne Witold Lewandowski.
lock_openI want to access the files
close
Slide to go back ↩