PUE C315 Weighing Terminal

Selected language
PUE C315 Weighing Terminal
This image is for reference only.

PUE C315 Weighing Terminal

Product code: WX-008-0150
close
Change the model:
PUE C315 Weighing Terminal
Select all
View
Download
Overview
 
 
Datasheet
OIML Class

III

 

Maximum quantity of divisions from converter

838 860 ×10

 

Maximum quantity of verification units

6000 e

 

Minimum volatge per verification unit

0,4 µV

 

Maximum voltage per verification unit

3,25 µV

 

Minimum load cell impedance

50 Ω

 

Maximum load cell impedance

1200 Ω

 

Load cell excitation voltage

5V DC

 

Maximum increase of signal

39 mV

 

Connection of load cells

4 or 6 wires + shield

 

Display

LCD (backlit)

 

Device dimensions

181×136×60

 mm

Packaging dimensions

220×190×90

 mm

Net weight

0,6

 kg

Gross weight

0,78

 kg

Protection class

IP 43

 

Keypad

microswitch

 

Housing

ABS plastic

 

Communication interface

RS232

 

Optional interfaces

RS232

 

Power supply

100 – 240 V AC 50/60 Hz

 

Power consumption max.

5 W

 

Optional power supply

12 V DC and battery

 

Operation time on batteries

max 7h

 

Power supply

detachable adapter, battery NiMH 6×AA

 

Number of buttons

5

 

Multiple range

1 or 2 ranges

 

Additional LCD display

WD-4/8 (option)

 

Operating temperature

-10 – +40

 °C

Storage temperature

-10 – +50

 °C

Relative humidity

10% – 80% RH no condensation

 

CE
2 years warranty
Videos
Complete Solutions for Mass Measurement in Pharma Industry
Functions
Plus/Minus Control

Plus/Minus Control

Control of sample's mass carried out with reference to specified MIN and MAX thresholds. The weight is considered to be correct if it is comprised within threshold values. A graphic visualisation of weighing result is displayed in a form of a bar graph.
Percent Weighing

Percent Weighing

Percent Weighing function is used for comparision of measured products with mass standard. Mass of a mass standard may be a numeric value taken from a database or it may be determined through a measurement process. Each measured product is compared to mass standard, mass of which is presumed as a model 100% ideal mass. For products weighing less than the mass standard, obtained results are lower than 100%, for products weighing more, the obtained results are greatly  exceeded.
Totalizing

Totalizing

Function adding new mass value to already obtained one. This allows to determine mass content of the mixture, being a composition of number of different consistence components. Totalizing is limited by maximum capacity parameter.
Parts counting

Parts counting

Function using mass measurement for determination of  measured items quantity. Mass of a single item is required for this process. It may be either estimated through weighment or taken from a database. For items counting the following algorithm is used: all items mass / single item mass = quantity. Function operation is supperted by a mechanism of Automatic Correction of Accuracy. This allows to update single item mass in course of the process. To a certain extend Automatic Correction of Accuracy eliminates error which may be a result of different mass values of seemingly alike single elements. For industry solutions items counting may be simultaneously carried out with checkweighing and dosing thus industry solutions feature audio signalling base informing that specified number of items has been weighed. It is possible to apply weighing systems using few platfroms of different MAX capacities and different accuracies.
Internal battery

Internal battery

Internal and rechargeable battery of SLA 6 V type (sealed lead acid) enables device operation without connecting the device to the mains (9h operation). The weighing instrument controls battery status and displays a respective pictogram on the screen.
Peak hold

Peak hold

Function registering the greatest temporary indication occurring in course of the weighing process. It is most often used in medical scales in order to hold the measurement indication.
GLP Procedures

GLP Procedures

Diagnostic function allowing to objectively document performed measurements. GLP procedures may be either presented in a short report form or extended one.
Animal weighing

Animal weighing

Process of mass determination for a product which may unwillingly reposition within the weighing pan. Mass determination in such cases requires much longer period of time when compared to typical weighing process. It is the user who defines period of time needed for control of measured product mass. The user can thus optimize the function depending on the measured product characteristics.
ALIBI Memory

ALIBI Memory

"ALIBI" memory enables saving and storing up to 100000 measurements.  Measurements are saved automatically upon each pressing of the key. There is no need for any additional operations or changing settings.
The following data related with the measurements is saved: measurement date; measurement time; result (mass); tare value; operator carrying out the measurement (logged in); product name.
The software saves the measurement in a so called loop, i.e. when the measurement no. 100001 is saved, the measurement 1 gets automatically deleted from the memory.
Measurements saved to balance memory cannot be deleted.
You can preview and print out the data saved to the ALIBI database.
Documentation
Data Sheet Data Sheet
Data Sheet

View
View
Download
Download

Choose more product:
View View DownloadDownload
User Manual - PUE C315
User Manual - PUE C315
View
View
Download
Download
(1.27 MB)
User Manual - CBCP 01
User Manual - CBCP 01
View
View
Download
Download
(0.30 MB)
Start up Guide
Start up Guide
View
View
Download
Download
(0.71 MB)
Software Manual - PUE C315
Software Manual - PUE C315
View
View
Download
Download
(1.39 MB)
Conformity Declaration
Conformity Declaration
View
View
Download
Download
(0.04 MB)
C315 Platform Scales
C315 Platform Scales
View
View
Download
Download
(2.13 MB)
Terminals and Platforms
Terminals and Platforms
View
View
Download
Download
(3.70 MB)
Accessories

Newsletter

If you wish to receive the latest news about RADWAG products and services, sign up for the newsletter.

More
Radwag Balances and Scales
Torunska 5
26-600 Radom
Poland
tel.: +48 48 386 60 00
e-mail: export@radwag.com
TIN: PL7960000327
Vimeo Radwag YouTube Radwag Facebook Radwag LinkedIn Radwag
© 2024 RADWAG Balances and Scales. All rights reserved.

Select language

×
Change language AlbanianAlbanian
Change language DanishDanish
Change language NederlandseNederlandse
Change language EstonianEstonian
Change language FinnishFinnish
Change language HungarianHungarian
Change language IcelandicIcelandic
Change language KazakhKazakh
Change language LatvianLatvian
Change language LithuanianLithuanian
Change language MacedonianMacedonian
Change language NorwegianNorwegian
Change language PortuguesePortuguese
Change language RomanianRomanian
Change language RussianRussian
Change language SlovakSlovak
Change language SlovenianSlovenian
Change language SwedishSwedish
Change language UkrainianUkrainian
Change language SerbianSerbian
Change language MontenegrinMontenegrin
Change language page on Deutsch Deutsch
Change language page on English English
Change language page on Español Español
Change language page on Français Français
Change language page on Italiano Italiano
Change language page on Polski Polski
Change language page on Türkiye Türkiye
Česky
Português (Brasil)
Change website to USA USA
Change language page on 中文 中文
Presentations Presentations Presentations
Subscribe Subscribe Subscribe
Radwag in Facebook Radwag in Facebook Facebook
Radwag in YouTube Radwag in YouTube Youtube
Radwag in Vimeo Radwag in Vimeo Vimeo
Radwag in LinkedIn Radwag in LinkedIn LinkedIn
Webinars Radwag Webinars Radwag Webinars
close
E-mail:
Company name:
Name:
I consent to the processing of my personal data for marketing purposes by Radwag Wagi Elektroniczne Witold Lewandowski.
I consent to receive marketing and product-related messages by electronic means from Radwag Wagi Elektroniczne Witold Lewandowski.
I have read the Privacy Policy of RADWAG Wagi Elektroniczne Witold Lewandowski.
lock_openI want to access the files
close
Slide to go back ↩