Bilancia WPY 6/15.F1.R.PGC

Radwag Bilance e sistemi di pesatura
Selected language Italiano
Bilancia WPY 6/15.F1.R.PGC
This image is for reference only.

Bilancia WPY 6/15.F1.R.PGC

Codice prodotto: WK-308-1052
Change the model (13)
done
Max: 6 / 15kgd: 2 / 5g

 300×300mm
expand_more
Max: 0,6 / 1,5kgd: 0,2 / 0,5g

 195×195mm
Max: 1,5 / 3kgd: 0,5 / 1g

 195×195mm
Max: 3 / 6kgd: 1 / 2g

 300×300mm
Max: 3 / 6kgd: 1 / 2g

 300×300mm
Max: 3 / 6kgd: 1 / 2g

 195×195mm
Max: 6 / 15kgd: 2 / 5g

 300×300mm
Max: 15 / 30kgd: 5 / 10g

 400×500mm
Max: 15 / 30kgd: 5 / 10g

 400×500mm
Max: 15 / 30kgd: 5 / 10g

 300×300mm
Max: 15 / 30kgd: 5 / 10g

 300×300mm
Max: 30 / 60kgd: 10 / 20g

 400×500mm
Max: 30 / 60kgd: 10 / 20g

 400×500mm
Capacita massima  [Max]: 6 / 15 kg
Accuratezza: 2 / 5 g

close
Change the model:
Bilancia WPY 0.6/1.5.D2.CPG
Bilancia WPY 1,5/3.D2.PGC
Bilancia WPY 3/6.F1.K.PGC
Bilancia WPY 3/6.F1.R.PGC
Bilancia WPY 3/6.D2.PGC
Bilancia WPY 6/15.F1.K.PGC
Bilancia WPY 6/15.F1.R.PGC
Bilancia WPY 15/30.C2.K.PGC
Bilancia WPY 15/30.C2.R.PGC
Bilancia WPY 15/30.F1.K.PGC
Bilancia WPY 15/30.F1.R.PGC
Bilancia WPY 30/60.C2.K.PGC
Bilancia WPY 30/60.C2.R.PGC
Select all
Vista
Salva
Aggiungere a confrontare
Caratteristiche generali
 

Bilancia WPY per controllo statistico

 
Le bilance serie WPY/CPG sono equipaggiate con moduli che rendono pratico e semplice il controllo di prodotti preconfezionati. Il modulo e supportato da un database contenente le liste di operatori e prodotti. Una volta iniziata la procedura di controllo viene chiusa automaticamente dopo avere eseguito il numero di controlli predefinito. Il numero di pesate (controlli) da eseguire viene definito automaticamente dalla bilancia in funzione della numerosita del lotto. Le bilance sono equipaggiate con un display grafico touch screen a colori da 5,7" per la visualizzazione delle informazioni dei controlli eseguiti e dei loro risultati aggiornati in tempo reale.
 
 
 
 

La procedura di controllo segue lo schema seguente:

  • scelta dell’operatore,
  • scelta del prodotto,
  • inzio del controllo,
  • acquisizione dei valori delle pesate,
  • il controllo finisce quando sono stati pesati il numero di campioni predefinito,
  • stampa del rapporto di prova.
Ogni ciclo di controllo eseguito finisce con la redazione del rapporto di prova finale contenente tutte le informazioni necessarie secondo quanto richiesto dalla normativa. Il rappporto viene automaticamente salvato nella memoria della bilancia ed allo stesso tempo puo essere stampato connettendo la relativa stampante al sistema.
 
 
 
 

La bilancia unita al programma permette:

  • mantenere i campi relativi alle pesate nel database, 
  • stampa automatica del processo di controllo direttamente dal PC
  • inviare codici definiti dall’operatore dalla bilancia al PC; i codici corrispondono ai prodotti pesati (codici prodotto, codici operatore, numerosita del lotto, numero di lotto, controllo di INIZIO/FINE),
  • definire i codici realtivi ai prodotti e la loro descrizione direttamente da compute. In questo modo un operatore puo assegnare una specifica descrizione del prodotto utile relativa alla divisione aziendale di appartenenza.
 

 

Lo scopo della bilancia è quello di controllare le merci preconfezionate CPG), quindi è necessaria la legalizzazione.
Si consiglia di ordinare una bilancia con la legalizzazione appropriata.
 
 
 
Stainless Steel in RADWAG products
Learn about the use and maintenance of stainless steel products:
Stainless Steel in RADWAG products. Standard and special applications
Foglio di calcolo
Capacita massima  [Max]

6 / 15

 kg

Pesata minima

40 / 100

 g

Accuratezza

2 / 5

 g

Intervallo di tara

-15

 kg

Classe OIML

III

 

Display

5,7” Resistiv-Farb-Touchscreen

 

Dimensioni del piatto di pesata

300×300

 mm

Dimensioni del pacco

570×390×170

 mm

Interfaccia

2×RS232, 2×USB-A, Ethernet, 4 IN / 4 OUT (digital), Wi-Fi®

 

Alimentatore

100 – 240 V AC 50/60 Hz

 

Temperatura di lavoro

-10 — +40

 °C

Umidita atmosferica

10% — 85% RH no condensation

 

CE
Garanzia 2 anni
Verifica automatica della bilancia
controllo prodotti preconfezionati
Video
Complete Solutions for Mass Measurement in Pharma Industry
funzioni
Dosing

Dosing

Weighing process for which reference mass has been determined together with tolerance for its determination. Dosing tolerance is given in [%] and it is calculated in relation to the reference value thus being a permissible deviation of this process. This solution is used for weighing powders, liquids and loose materials. Dosing function performance is often supported with bargraph - load indicator. For industrial scales it is possible to use a control systems of dosing process.
Labelling

Labelling

Marking products with the right symbols contributes to quick and reliable identification. The balance/scale usually transfers product mass or product quantity to the label printer. The transferred value is printed with the following information: bar code, pictogram, content, address etc. In laboratory the labelling is performed in a semi-automatic mode, for industry in an automatic one (dynamic scales).
Plus/Minus Control

Plus/Minus Control

Control of sample's mass carried out with reference to specified MIN and MAX thresholds. The weight is considered to be correct if it is comprised within threshold values. A graphic visualisation of weighing result is displayed in a form of a bar graph.
Percent Weighing

Percent Weighing

Percent Weighing function is used for comparision of measured products with mass standard. Mass of a mass standard may be a numeric value taken from a database or it may be determined through a measurement process. Each measured product is compared to mass standard, mass of which is presumed as a model 100% ideal mass. For products weighing less than the mass standard, obtained results are lower than 100%, for products weighing more, the obtained results are greatly  exceeded.
Totalizing

Totalizing

Function adding new mass value to already obtained one. This allows to determine mass content of the mixture, being a composition of number of different consistence components. Totalizing is limited by maximum capacity parameter.
Parts counting

Parts counting

Function using mass measurement for determination of  measured items quantity. Mass of a single item is required for this process. It may be either estimated through weighment or taken from a database. For items counting the following algorithm is used: all items mass / single item mass = quantity. Function operation is supperted by a mechanism of Automatic Correction of Accuracy. This allows to update single item mass in course of the process. To a certain extend Automatic Correction of Accuracy eliminates error which may be a result of different mass values of seemingly alike single elements. For industry solutions items counting may be simultaneously carried out with checkweighing and dosing thus industry solutions feature audio signalling base informing that specified number of items has been weighed. It is possible to apply weighing systems using few platfroms of different MAX capacities and different accuracies.
Peak hold

Peak hold

Function registering the greatest temporary indication occurring in course of the weighing process. It is most often used in medical scales in order to hold the measurement indication.
Formulation

Formulation

Function supporting the mixture making process, wherein the mixture contains various components. Formulation function usually uses the balance/scale database of components. Formulation serves for monitored checkweighing of every single component with a given tolerance. It is enriched with a set of individual settings.
Statistics

Statistics

Statistiscs function registers and analyses performed measurements. This supplies the user withthe following information: Max and Min standard deviation, average value, variance, range et.
Checkweighing

Checkweighing

Checkweighing function is used for checking whether the measured sample mass is within the predefined threshold values, Low [LO] and Hgh [HI]. The thresholds are given in [g] and [kg] units. Current state of a sample being measured is signalled by means of pictorgams located on a display for laboratory balances, for industrial scales Stackligt System is used. This visual +/- inspection is in operation during segregation, control or packing process of products for which mass has bees determined with a specifaied tolerance, eg. 12860 g 961
IR sensors

IR sensors

Programmable function supporting the weighing process through control of the following options: sliding weighing chamber doors, printout, zeroing, tarring etc. Especially appreciated wherever preventing the balance from soiling is important.
Animal weighing

Animal weighing

Process of mass determination for a product which may unwillingly reposition within the weighing pan. Mass determination in such cases requires much longer period of time when compared to typical weighing process. It is the user who defines period of time needed for control of measured product mass. The user can thus optimize the function depending on the measured product characteristics.
Differential weighing

Differential weighing

Differential weighing informs about mass variation a particular sample, wherein the said variation is a result of manufacturing processes.

Differential weighing is often applied in product control process, for which reference product parameters have been specified in order to be used as a source of comparison for the whole series.
Insuchcasestandard deviation is the information which tells about quality and completeness of a final product. For systems based on a feed-back technique such information may be used by control units.
Packaged Goods Control

Packaged Goods Control

Pre-packaged Goods Control mode enables to collect weighings from RADWAG-designed weighing instruments, carry out control and generate PGC reports. Different types of weighing instruments can be combined into a network. The control can be started on a balance or via computer software. It is automatically finished after a respective quantity of packages is verified.
Collected data allows you to assess quality of produced pre-packaged goods and their conformity with:
- internal quality control system;
- 'Pre-Packaged Goods' regulation of 7th May 2009 (Journal of Laws No 91, item 740), on the requirements concerning quantity inspection of pre-packaged goods control, which inspection is to be carried out by means of random selection of the measurements results and sending those results to pre-packaged goods control procedure.
ALIBI Memory

ALIBI Memory

"ALIBI" memory enables saving and storing up to 100000 measurements.  Measurements are saved automatically upon each pressing of the key. There is no need for any additional operations or changing settings.
The following data related with the measurements is saved: measurement date; measurement time; result (mass); tare value; operator carrying out the measurement (logged in); product name.
The software saves the measurement in a so called loop, i.e. when the measurement no. 100001 is saved, the measurement 1 gets automatically deleted from the memory.
Measurements saved to balance memory cannot be deleted.
You can preview and print out the data saved to the ALIBI database.
Documentazione
Data Sheet Data Sheet
Data Sheet

Vista
Vista
Salva
Salva

Choose more product:
Vista Vista SalvaSalva
User Manual - WPY Multifunctional Scale
User Manual - WPY Multifunctional Scale
Vista
Vista
Salva
Salva
(1.68 MB)
Software Manual - CBCP 03
Software Manual - CBCP 03
Vista
Vista
Salva
Salva
(0.23 MB)
Start up Guide
Start up Guide
Vista
Vista
Salva
Salva
(1.26 MB)
Quick start
Quick start
Vista
Vista
Salva
Salva
(2.47 MB)
Software Manual - Appendices 01
Software Manual - Appendices 01
Vista
Vista
Salva
Salva
(1.81 MB)
Software Manual - PUE 7.1
Software Manual - PUE 7.1
Vista
Vista
Salva
Salva
(6.55 MB)
Conformity Declarations
Conformity Declarations
Vista
Vista
Salva
Salva
(0.04 MB)
THBR System 2.0
THBR System 2.0
Vista
Vista
Salva
Salva
(5.17 MB)
Stainless Steel in RADWAG products. Standard and special applications
Stainless Steel in RADWAG products. Standard and special applications
Vista
Vista
Salva
Salva
(2.23 MB)
PUE 7.1 Terminal
PUE 7.1 Terminal
Vista
Vista
Salva
Salva
(2.33 MB)
Accessori
Radwag bilance e sistemi di pesatura
Torunska 5
26-600 Radom
Poland
tel.: +48 48 386 60 00
e-mail: export@radwag.com
TIN: PL7960000327
Vimeo Radwag YouTube Radwag Facebook Radwag LinkedIn Radwag
© 2024 Radwag bilance e sistemi di pesatura. Diritti riservati

selezionare

×
Change language AlbanianAlbanian
Change language DanishDanish
Change language NederlandseNederlandse
Change language EstonianEstonian
Change language FinnishFinnish
Change language HungarianHungarian
Change language IcelandicIcelandic
Change language KazakhKazakh
Change language LatvianLatvian
Change language LithuanianLithuanian
Change language MacedonianMacedonian
Change language NorwegianNorwegian
Change language PortuguesePortuguese
Change language RomanianRomanian
Change language RussianRussian
Change language SlovakSlovak
Change language SlovenianSlovenian
Change language SwedishSwedish
Change language UkrainianUkrainian
Change language SerbianSerbian
Change language MontenegrinMontenegrin
Change language page on Deutsch Deutsch
Change language page on English English
Change language page on Español Español
Change language page on Français Français
Change language page on Polski Polski
Change language page on Türkiye Türkiye
Česky
Change website to USA USA
Change language page on 中文 中文
Subscribe Subscribe Subscribe
Radwag in Facebook Radwag in Facebook Facebook
Radwag in YouTube Radwag in YouTube Youtube
Radwag in Vimeo Radwag in Vimeo Vimeo
Radwag in LinkedIn Radwag in LinkedIn LinkedIn
Webinars Radwag Webinars Radwag Webinars
close
E-mail
nome azienda:
Nome:
I consent to the processing of my personal data for marketing purposes by Radwag Wagi Elektroniczne Witold Lewandowski.
I consent to receive marketing and product-related messages by electronic means from Radwag Wagi Elektroniczne Witold Lewandowski.
I have read the Privacy Policy of RADWAG Wagi Elektroniczne Witold Lewandowski.
lock_openI want to access the files
close
Slide to go back ↩