Codice prodotto: WL-101-1006
Richiesta di offerta

caratteristiche generali

Capacita massima  [Max]: 0,8 / 3g
Divisione: 1 / 10µg


Misure

piu veloci con la CPU di nuova generazione

Le

bilance

serie 4Y sono caratterizzate da un processore Dual Core 2 x 1 GB che garantisce un significativo potenziamento delle prestazioni inclusa un migliore velocita operativa e tempi di stabilizzazione piu contenuti garantendo una migliiore ripetibilita.

16 GB RAM – maggiore potenzialita di gestione dei dati
La RAM da 16 GB offre la possibilita di registrare i dati sotto forma di rapporti complessi. Orari e diagrammi statistici riferiti a serie di pesate sono una ulteriore utile opzione.

La miglior ripetibilita ottenibile e la conformita alle normative USP
La miglior accuratezza e ripetibilita – con deviazione standard ≤ 1d combinata alla conformita alla normativa USP (Sezioni 41 e 1251) rendono le

bilance

serie 4Y il nuovo standard di quallita nella misura del peso.

Ergonomia e sicurezza
La comunicazione tra l’unita di pesata ed il terminale rende possibile un utilizzo confortevole delle bilance serie 4Y anche quando installate all’interno di cappe a flusso laminare o cappe chimiche.

Controllo dell’operativita in remoto
Il modulo di connessione wireless offre il trasferimento dei dati registrati dalla

bilancia

seri 4Y in modo wireless ad ogni unita portatile equipaggiata con sistema operativo iOS o android utilizzando una speciale applicazione sviluppata per la gestione dei dati

Sicurezza dei dati
Ogni

bilancia

serie 4Y e equipaggiata con una memoria ALIBI sviluppata per garantire la protezione e la registrazione automatica delle

misure.

Sono inoltre disponibili per gli utilizzatori funzioni come la previsione dei dati, la copia e l’archiviazione degli stessi.

Opzione pesata filtri
Questa soluzione innovative permette agli utilizzatori di cambiare velocemente la camera di pesata standard con quella speciale per la pesatura filtri, che espande considerevolmente le funzionalità delle microbalance serie MYA 4Y.  Il piatto di pesata, forato, è di dimensioni elevate per garantire pesate accurate di filtri di varie dimensioni (fino a ø100 mm). La camera è realizzata in acciaio inox ed è resistente agli agenti chimici, a danni da abrasione e mantiene nel tempo le sue caratteristiche. La camera addizionale è un accessorio che và ordinato a parte.

Video

New weighing chamber for MYA.4Y and UYA.4Y microbalances
4y series - Ultra-microbalances and microbalances
4Y Balances: Video-Guidance and an on-screen manuals
4Y Series RADWAG Balances

Caratteristiche

Electronic
level indicator
Functions:
- ALARM function
- graphic level indicator
- programmable acceptable tilts

Electronic
level indicator

Functions:
- ALARM function
- graphic level indicator
- programmable acceptable tilts
Data exchange through
USB storage devices
- update balance software
- export weighing data
- export/import databases
- export/import balance settings
- exchange data between balances

Data exchange through
USB storage devices

- update balance software
- export weighing data
- export/import databases
- export/import balance settings
- exchange data between balances
Infrared
proximity sensors
Optional functions:
- PRINT function
- TARE function
- sensor's sensitivity adjustment

Infrared
proximity sensors

Optional functions:
- PRINT function
- TARE function
- sensor's sensitivity adjustment
Portability
Extra option:
Balances with
a wireless terminal

Portability

Application:

Elimination of extra sources of vibration
Using wireless terminal facilitates elimination of additional vibrations resulting from daily operation on a balance. Owing to that, balances with highest resolutions might be used without the need of dedicated weighing workstations.

Convenience and comfort of weighing in fume cupboards and laminar flow cabins
Wireless communication between a terminal and a weighing module makes balance operation more comfortable and safer.

Balance isolation form influence of environmental conditions
Wireless communication allows to either place the weighing module inside a draft shield or to isolate it from the operator. This allows to weight toxic substances without putting operator's health or life at risk.
Interfaces
- Ethernet
- 2×USB
- 2×RS 232
- 4 in / 4 out
- WiFi 2,4GHz b,g,n

Interfaces

- Ethernet
- 2×USB
- 2×RS 232
- 4 in / 4 out
- WiFi 2,4GHz b,g,n

funzioni

Autotest

Autotest

Diagnostic function aiming at metrological parameters determination (repeatability), the parameters are determined for the actual conditions of use. When speaking of repeatability it may be also used for weighing time optimization. Autotest is operated in an automatic mode thus operator’s time is saved.
Dosing

Dosing

Weighing process for which reference mass has been determined together with tolerance for its determination. Dosing tolerance is given in [%] and it is calculated in relation to the reference value thus being a permissible deviation of this process. This solution is used for weighing powders, liquids and loose materials. Dosing function performance is often supported with bargraph - load indicator. For industrial scales it is possible to use a control systems of dosing process.
Percent Weighing

Percent Weighing

Percent Weighing function is used for comparision of measured products with mass standard. Mass of a mass standard may be a numeric value taken from a database or it may be determined through a measurement process. Each measured product is compared to mass standard, mass of which is presumed as a model 100% ideal mass. For products weighing less than the mass standard, obtained results are lower than 100%, for products weighing more, the obtained results are greatly  exceeded.
Parts counting

Parts counting

Function using mass measurement for determination of  measured items quantity. Mass of a single item is required for this process. It may be either estimated through weighment or taken from a database. For items counting the following algorithm is used: all items mass / single item mass = quantity. Function operation is supperted by a mechanism of Automatic Correction of Accuracy. This allows to update single item mass in course of the process. To a certain extend Automatic Correction of Accuracy eliminates error which may be a result of different mass values of seemingly alike single elements. For industry solutions items counting may be simultaneously carried out with checkweighing and dosing thus industry solutions feature audio signalling base informing that specified number of items has been weighed. It is possible to apply weighing systems using few platfroms of different MAX capacities and different accuracies.
Formulation

Formulation

Function supporting the mixture making process, wherein the mixture contains various components. Formulation function usually uses the balance/scale database of components. Formulation serves for monitored checkweighing of every single component with a given tolerance. It is enriched with a set of individual settings.
Statistics

Statistics

Statistiscs function registers and analyses performed measurements. This supplies the user withthe following information: Max and Min standard deviation, average value, variance, range et.
Checkweighing

Checkweighing

Checkweighing function is used for checking whether the measured sample mass is within the predefined threshold values, Low [LO] and Hgh [HI]. The thresholds are given in [g] and [kg] units. Current state of a sample being measured is signalled by means of pictorgams located on a display for laboratory balances, for industrial scales Stackligt System is used. This visual +/- inspection is in operation during segregation, control or packing process of products for which mass has bees determined with a specifaied tolerance, eg. 12860 g 961
IR sensors

IR sensors

Programmable function supporting the weighing process through control of the following options: sliding weighing chamber doors, printout, zeroing, tarring etc. Especially appreciated wherever preventing the balance from soiling is important.
GLP Procedures

GLP Procedures

Diagnostic function allowing to objectively document performed measurements. GLP procedures may be either presented in a short report form or extended one.
Animal weighing

Animal weighing

Process of mass determination for a product which may unwillingly reposition within the weighing pan. Mass determination in such cases requires much longer period of time when compared to typical weighing process. It is the user who defines period of time needed for control of measured product mass. The user can thus optimize the function depending on the measured product characteristics.
Air density correction

Air density correction

Function performing correction of mass measurement indication, wherein the air density is taken into account. It is used in balances with reading unit < 0,01 mg.
Automatic sliding door

Automatic sliding door

Automatic side panes opened via touch-free IR sensors.
Moveable range

Moveable range

Dual range analytical balances can be equipped with much more precise measuring range but only in very limited part of max capacity and only from zero load. A new technology introduced by RADWAG allows for moving this limited range till max capacity of the balance is reached. Such solution has been named as: Moveable range.
Differential weighing

Differential weighing

Differential weighing informs about mass variation a particular sample, wherein the said variation is a result of manufacturing processes.

Differential weighing is often applied in product control process, for which reference product parameters have been specified in order to be used as a source of comparison for the whole series.
Insuchcasestandard deviation is the information which tells about quality and completeness of a final product. For systems based on a feed-back technique such information may be used by control units.
Replaceable unit

Replaceable unit

Replaceable units.
Statistical Quality Control

Statistical Quality Control

Statistical control for determination of basic statistical criteria: maximum, minimum, standard deviation, mean values for each batch, etc.
ALIBI Memory

ALIBI Memory

"ALIBI" memory enables saving and storing up to 100000 measurements.  Measurements are saved automatically upon each pressing of the key. There is no need for any additional operations or changing settings.
The following data related with the measurements is saved: measurement date; measurement time; result (mass); tare value; operator carrying out the measurement (logged in); product name.
The software saves the measurement in a so called loop, i.e. when the measurement no. 100001 is saved, the measurement 1 gets automatically deleted from the memory.
Measurements saved to balance memory cannot be deleted.
You can preview and print out the data saved to the ALIBI database.

foglio di calcolo

Capacita massima  [Max]

0,8 / 3

 g

pesata minima

100

 µg

Divisione

1 / 10

 µg

intervallo di tara

-3

 g

Ripetibilita (5% Max)

1

 µg

Ripetibilita (Max)

4,1

 µg

linearita

±3 / 10

 µg

carico decentrato

3 / 10

 µg

pesata minima (U=1%,k=2)

0,2

 mg

pesata minima (secondo USP)

2

 mg

tempo di stabilizzazione

max 8

 s

Calibrazione

internal (automatic)

 

Classe OIML

I

 

display

5,7” resistive colour touchscreen

 

interfaccia

2×RS232, 2×USB-A, Ethernet, 4 IN / 4 OUT (digital), Wi-Fi®

 

Alimentatore

100 ÷ 240 V AC 50 / 60 Hz

 

Massimo assorbimento elettrico

700 mA (wireless terminal - 1A)

 

temperatura di lavoro

+10 ÷ +40

 °C

Velocita di variazione della temperatura

±0,3°C/1h (±1°C/8h)

 

Umidita atmosferica

40% ÷ 80%

 

Velocita di variazione della umidita atmosferica

±1%/h (±4%/8h)

 

dimensioni della camera di pesata

ø90×90

 mm

Dimensioni del piatto di pesata

ø16 + ø60 (for filters)

 mm

Packaging dimensions

660×660×455

 mm

Peso netto

9,1

 kg

Peso lordo

16,6

 kg

documentazione

specifiche tecniche
Publications and teaching materials

Manuals
(6.07 MB) EN

Save
See the publication

Data Sheet
(0.18 MB) EN

Save
See the publication

Data Sheet
(1.55 MB) EN

Save
See the publication

Conformity Declaration
(0.04 MB) EN

Save
See the publication

Defined Weighing Profiles
(1.64 MB) EN

Save
See the publication

THBR System 2.0
(5.24 MB) EN

Save
See the publication

Detection of vibrations at the electronic balances workstation
(2.02 MB) EN

Save
See the publication

4Y - Brand New Series of Laboratory Balances
(1.78 MB) EN

Save
See the publication

4Y Series Balances
(15.04 MB) EN

Save
See the publication

Ultra-Microbalances and Microbalances
(14.61 MB) EN

Save
See the publication

Micro Scale Measurement
(2.74 MB) EN

Save
See the publication

Principles_of_metrology
(0.10 MB) EN

Save
See the publication

Determination_of_total_and_respirable_air
(0.21 MB) EN

Save
See the publication

Autotest
(0.10 MB) EN

Save
See the publication

Guidelines for a weighing room for correct microbalance and mass comparator operation
(0.82 MB) EN

Save
See the publication

Influence of seismic on measuring accuracy of electronic weighing instruments
(0.55 MB) EN

Save
See the publication

Microbalances working conditions
(2.25 MB) EN

Save
See the publication

Accessori

Tavoli antivibranti in marmo
tavoli antivibranti per bilance da laboratorio
tavolo di pesata professionale
Audit Trail Reader

Accessori

nome prodotto:

caratteristiche generali

Audit Trail Reader

Audit Trail Reader ...

Sistema E2R
Editore di etichette R02
Editore parametri
Codice a barre R
R-LAB
RAD-KEY
RADWAG Connect
Studio di sviluppo RADWAG
RADWAG Remote Desktop
Driver LabVIEW
Camera per pesata filtra MYF
Stampanti di ricevuta
stampanti per etichette
ionizzatore anti statico
THBR 2.0 - modulo misura parametri ambientali

Accessori

nome prodotto:

caratteristiche generali

Modulo THB P

...

Modulo THB S

...

Cavo seriale RS 232, RS 485
Cavo seriale RS 232 (connessione bilance - Stampanti EPSON)
lettore di codici a barre
Anti-Draft Chamber for Microbalances
Display
Alimentatore

Radwag bilance e sistemi di pesatura

Torunska 5
26-600 Radom
Poland
tel.: +48 48 386 60 00
e-mail: export@radwag.com
TIN: PL7960000327
Vimeo Radwag YouTube Radwag Facebook Radwag
© 2019 Radwag bilance e sistemi di pesatura. Diritti riservati

See our movies
RADWAG

Radwag WEBINARS