HY10.60.H3.K Bilance multifunzione

HY10.60.H3.K Bilance multifunzione view:1

Codice prodotto: WP-116-0016
Informazione sulla conformita di un prodotto alle normative Europee riferite allo specifico prodotto. Marcare il prodotto con il marchio CE rende il produttore responsabile della rispondenza del prodotto alle direttive generali di sicurezza determinate dalle norme di marcatura CE
CE
Informazione sulla conformita di un prodotto alle normative Europee riferite allo specifico prodotto. Marcare il prodotto con il marchio CE rende il produttore responsabile della rispondenza del prodotto alle direttive generali di sicurezza determinate dalle norme di marcatura CE
The procedure within the scope of Legal Metrology. It is performed by regional Offices of Measures or authorized entities before the new product is introduced to the market.  The procedure is performed on the basis of tests validating conformity of a product with the directives. For most measuring devices, including balances and scales, this procedure has been replaced with declaration of conformity.
CE
Informazione sulla conformita di un prodotto alle normative Europee riferite allo specifico prodotto. Marcare il prodotto con il marchio CE rende il produttore responsabile della rispondenza del prodotto alle direttive generali di sicurezza determinate dalle norme di marcatura CE
verifica
The procedure within the scope of Legal Metrology. It is performed by regional Offices of Measures or authorized entities before the new product is introduced to the market. The procedure is performed on the basis of tests validating conformity of a product with the directives. For most measuring devices, including balances and scales, this procedure has been replaced with declaration of conformity.
CE
Informazione sulla conformita di un prodotto alle normative Europee riferite allo specifico prodotto. Marcare il prodotto con il marchio CE rende il produttore responsabile della rispondenza del prodotto alle direttive generali di sicurezza determinate dalle norme di marcatura CE
verifica
The procedure within the scope of Legal Metrology. It is performed by regional Offices of Measures or authorized entities before the new product is introduced to the market. The procedure is performed on the basis of tests validating conformity of a product with the directives. For most measuring devices, including balances and scales, this procedure has been replaced with declaration of conformity.
garanzia 2 anni
Richiesta di offerta

caratteristiche generali

Capacita massima  [Max]: 60kg

Divisione: 20g


Le bilance multifunzione serie HY10 sono progettate per eseguire determinazioni del peso veloci e precise in ambienti industriali.
Le bilance serie HY10 sono equipaggiate da un terminale PUE HY10 costruito con struttura in acciaio inox ed un basamento sempre in acciaio inox.
Per queste bilance viene utilizzato acciaio inox OH18N9 incluso il piatto di pesata e sono equipaggiate con da uno schermo a colori touch screen da 10,1” ed una tastiera numerica con pulsanti funzione.
La serie HY10 permette alla bilancia di essere connessa a piattoforme addizionali.
 
In piu queste bilance offrono tutte le funzionalita disponibili nei terminali PUE HY10:
Display programmabile con pulsanti funzione,
Grafiche ed impostazione personalizzabile dei rapporti,
Programmazione di linee di testo esplicative sul display
Le bilance multifunzione serie HY10 sono fornite con il terminale separato connesso via cavo alla piattaforma.

Le bilance serie HY10 sono disponibili anche in versione „dual range” (opzione).

media

funzioni

Dosing

Dosing

Radwag Dosing
Weighing process for which reference mass has been determined together with tolerance for its determination. Dosing tolerance is given in [%] and it is calculated in relation to the reference value thus being a permissible deviation of this process. This solution is used for weighing powders, liquids and loose materials. Dosing function performance is often supported with bargraph - load indicator. For industrial scales it is possible to use a control systems of dosing process.
Labelling

Labelling

Radwag Labelling
Marking products with the right symbols contributes to quick and reliable identification. The balance/scale usually transfers product mass or product quantity to the label printer. The transferred value is printed with the following information: bar code, pictogram, content, address etc. In laboratory the labelling is performed in a semi-automatic mode, for industry in an automatic one (dynamic scales).
Plus/Minus Control

Plus/Minus Control

Radwag Plus/Minus Control
Plus/Minus Control
Percent Weighing

Percent Weighing

Radwag Percent Weighing
Percent Weighing function is used for comparision of measured products with mass standard. Mass of a mass standard may be a numeric value taken from a database or it may be determined through a measurement process. Each measured product is compared to mass standard, mass of which is presumed as a model 100% ideal mass. For products weighing less than the mass standard, obtained results are lower than 100%, for products weighing more, the obtained results are greatly  exceeded.
Totalizing

Totalizing

Radwag Totalizing
Function adding new mass value to already obtained one. This allows to determine mass content of the mixture, being a composition of number of different consistence components. Totalizing is limited by maximum capacity parameter.
Parts counting

Parts counting

Radwag Parts counting
Function using mass measurement for determination of  measured items quantity. Mass of a single item is required for this process. It may be either estimated through weighment or taken from a database. For items counting the following algorithm is used: all items mass / single item mass = quantity. Function operation is supperted by a mechanism of Automatic Correction of Accuracy. This allows to update single item mass in course of the process. To a certain extend Automatic Correction of Accuracy eliminates error which may be a result of different mass values of seemingly alike single elements. For industry solutions items counting may be simultaneously carried out with checkweighing and dosing thus industry solutions feature audio signalling base informing that specified number of items has been weighed. It is possible to apply weighing systems using few platfroms of different MAX capacities and different accuracies.
Peak hold

Peak hold

Radwag Peak hold
Function registering the greatest temporary indication occurring in course of the weighing process. It is most often used in medical scales in order to hold the measurement indication.
Formulation

Formulation

Radwag Formulation
Function supporting the mixture making process, wherein the mixture contains various components. Formulation function usually uses the balance/scale database of components. Formulation serves for monitored checkweighing of every single component with a given tolerance. It is enriched with a set of individual settings.
Newton unit measurement

Newton unit measurement

Radwag Newton unit measurement
Function allowing to perform the measurement in Newton unit, it may be used for processes aiming to determine force resulting in the sample damage.
Statistics

Statistics

Radwag Statistics
Statistiscs function registers and analyses performed measurements. This supplies the user withthe following information: Max and Min standard deviation, average value, variance, range et.
Checkweighing

Checkweighing

Radwag Checkweighing
Checkweighing function is used for checking whether the measured sample mass is within the predefined threshold values, Low [LO] and Hgh [HI]. The thresholds are given in [g] and [kg] units. Current state of a sample being measured is signalled by means of pictorgams located on a display for laboratory balances, for industrial scales Stackligt System is used. This visual +/- inspection is in operation during segregation, control or packing process of products for which mass has bees determined with a specifaied tolerance, eg. 12860 g 961
GLP Procedures

GLP Procedures

Radwag GLP Procedures
Diagnostic function allowing to objectively document performed measurements. GLP procedures may be either presented in a short report form or extended one.
Animal weighing

Animal weighing

Radwag Animal weighing
Process of mass determination for a product which may unwillingly reposition within the weighing pan. Mass determination in such cases requires much longer period of time when compared to typical weighing process. It is the user who defines period of time needed for control of measured product mass. The user can thus optimize the function depending on the measured product characteristics.
Differential weighing

Differential weighing

Radwag Differential weighing
Differential weighing informs about mass variation a particular sample, wherein the said variation is a result of manufacturing processes.<br />
Differential weighing is often applied in product control process, for which reference product parameters have been specified in order to be used as a source of comparison for the whole series.
Insuchcasestandard deviation is the information which tells about quality and completeness of a final product. For systems based on a feed-back technique such information may be used by control units.
Replaceable unit

Replaceable unit

Radwag Replaceable unit
Statistical Quality Control

Statistical Quality Control

Radwag Statistical Quality Control
ALIBI Memory

ALIBI Memory

Radwag ALIBI Memory
The used ALIBI memory is a data secure area and allows to record up to 100 000 weighment records. It ensures security of constant data register in the long time period.
Transactions

Transactions

Radwag Transactions

foglio di calcolo

Capacita massima  [Max] 60 kg
Divisione 20 g
dimensioni del piatto di pesata 410×410 mm
intervallo di tara -60 kg
temperatura di lavoro -10 ÷ +40 °C
Alimentatore 100 ÷ 240 V AC 50 ÷ 60 Hz 
display 10,1" widescreen colour dispaly 1024x600 
interfaccia 2×RS 232, 2×USB, Ethernet, 4 IN / 4 OUT 
Packaging dimensions 670×510×330 mm
punteggio IP IP 68 construction, IP 68 (1h max)/69 indicator 
Umidita atmosferica 10÷85% RH no condensation 
Calibrazione external 
Intervallo di verifica della bilancia 20 g
Classe OIML III 
Peso netto/peso lordo 16/18 kg

documentazione

Technical Documentation

User Manual Terminal HY10
3.63 MB EN

see the publication

Data Sheet
1.24 MB EN

see the publication

Conformity Declaration
0.03 MB EN

see the publication

Certificate of Health Quality
0.43 MB EN

see the publication

ISO 9001:2015 Certificate
0.63 MB EN

see the publication
Publications and teaching materials

Accessori

Pesi standard F1 - cilindrico, set

Accessori

nome prodotto:

caratteristiche generali

Cilindrico, set (1 mg - 50 g), imballaggi in plastica

Cilindrico, set (1 mg - 50 g), imballaggi in plastica

...

banco a rulli
R-LAB
SISTEMA E2R
editore di etichette R02
Audit Trail Reader

Accessori

nome prodotto:

caratteristiche generali

Audit Trail Reader

Audit Trail Reader

Audit Trail Reader ...

RADWAG Connect
RADWAG Remote Desktop
Driver LabVIEW
Studio di sviluppo RADWAG
Codice a barre R
RAD-KEY
Editore parametri
Stampanti di ricevuta
stampanti per etichette
Camera di protezione anti polvere per stampanti
cavi IN/OUT
Cavo seriale RS 232 (connessione bilance - Ethernet)
cavo USB (connessione bilance - stampanti)
Cavo seriale RS 232 (connessione bilance - Computer)
Cavo seriale RS 232 (connessione bilance - Stampanti EPSON)
RS 232 cables (terminal - terminal)
Cavo seriale RS 232 (connessione bilance - Stampanti ZEBRA)
tastiera, interruttori esterni
lettore di codici a barre
Display
Radwag bilance
e sistemi di pesatura
Torunska 5
26-600 Radom
Poland
tel.: +48 48 386 63 03
e-mail: export@radwag.com
TIN: PL7960000327
Vimeo Radwag YouTube Radwag Facebook Radwag Google Plus Radwag
® 2018 Radwag bilance e sistemi di pesatura. Diritti riservati

See our movies
RADWAG