aggiungere a confrontare : Bilancia di precisione PM 15.C32

Selected language Italiano Italiano
Change language
Change language page on Deutsch DeutschChange language page on English EnglishChange language page on Español EspañolChange language page on Français FrançaisChange language page on Polski PolskiChange language page on Türkiye Türkiye ČeskyChange website to USA USAChange language page on 中文 中文

Bilancia di precisione PM 15.C32

Bilancia di precisione PM 15.C32 - The unique measuring system solution is characterized with great resistance to ambient conditions change. An in-built 4-point protection system prevents balance overloading, this ensures safety in case too heavy load is applied onto the weighing pan
This image is for reference only.

Codice prodotto: WL-223-0006
Richiesta di offerta

caratteristiche generali

Capacita massima  [Max]: 15kg
Divisione: 0,01g

PM series

balances

are equipped with an innovative measuring system based on RADWAG MonoBLOCK® technology.
Use of the new measuring system, which is a subject matter of RADWAG patent, guarantees stability of repeatability over time at a range sd<1d. The unique measuring system solution is characterized with great resistance to ambient conditions change.
An in-built 4-point protection system prevents

balance

overloading, this ensures safety in case too heavy load is applied onto the

weighing

pan.
 
Main features:
  • new RADWAG MonoBLOCK® sensor;
  • unrivalled repeatability of indications;
  • weighing

    of heavy loads with maximum accuracy;
  • intuitive operation guaranteed by a membrane keyboard;
  • fast

    mass

    measurements;
  • robust mechanical design – new lower weighing platform;
  • improved ergonomics – two types of weighing terminal for selection. 
Balance offers possibility of weighing loads outside the weighing platform (so called under-hook weighing). This is an alternative for weighing loads with non-standard dimensions and shapes or those generating magnetic field.

funzioni

Labelling

Labelling

Marking products with the right symbols contributes to quick and reliable identification. The balance/scale usually transfers product mass or product quantity to the label printer. The transferred value is printed with the following information: bar code, pictogram, content, address etc. In laboratory the labelling is performed in a semi-automatic mode, for industry in an automatic one (dynamic scales).
Plus/Minus Control

Plus/Minus Control

Control of sample's mass carried out with reference to specified MIN and MAX thresholds. The weight is considered to be correct if it is comprised within threshold values. A graphic visualisation of weighing result is displayed in a form of a bar graph.
Percent Weighing

Percent Weighing

Percent Weighing function is used for comparision of measured products with mass standard. Mass of a mass standard may be a numeric value taken from a database or it may be determined through a measurement process. Each measured product is compared to mass standard, mass of which is presumed as a model 100% ideal mass. For products weighing less than the mass standard, obtained results are lower than 100%, for products weighing more, the obtained results are greatly  exceeded.
Parts counting

Parts counting

Function using mass measurement for determination of  measured items quantity. Mass of a single item is required for this process. It may be either estimated through weighment or taken from a database. For items counting the following algorithm is used: all items mass / single item mass = quantity. Function operation is supperted by a mechanism of Automatic Correction of Accuracy. This allows to update single item mass in course of the process. To a certain extend Automatic Correction of Accuracy eliminates error which may be a result of different mass values of seemingly alike single elements. For industry solutions items counting may be simultaneously carried out with checkweighing and dosing thus industry solutions feature audio signalling base informing that specified number of items has been weighed. It is possible to apply weighing systems using few platfroms of different MAX capacities and different accuracies.
Statistics

Statistics

Statistiscs function registers and analyses performed measurements. This supplies the user withthe following information: Max and Min standard deviation, average value, variance, range et.
IR sensors

IR sensors

Programmable function supporting the weighing process through control of the following options: sliding weighing chamber doors, printout, zeroing, tarring etc. Especially appreciated wherever preventing the balance from soiling is important.
Under-pan weighing

Under-pan weighing

The solution enables weighing with use of a stand, which is advisable for loads of non-standard shapes and dimensions and those that generate magnetic field.
GLP Procedures

GLP Procedures

Diagnostic function allowing to objectively document performed measurements. GLP procedures may be either presented in a short report form or extended one.
Replaceable unit

Replaceable unit

Replaceable units.
ALIBI Memory

ALIBI Memory

"ALIBI" memory enables saving and storing up to 100000 measurements.  Measurements are saved automatically upon each pressing of the key. There is no need for any additional operations or changing settings.
The following data related with the measurements is saved: measurement date; measurement time; result (mass); tare value; operator carrying out the measurement (logged in); product name.
The software saves the measurement in a so called loop, i.e. when the measurement no. 100001 is saved, the measurement 1 gets automatically deleted from the memory.
Measurements saved to balance memory cannot be deleted.
You can preview and print out the data saved to the ALIBI database.

foglio di calcolo

Capacita massima  [Max]

15

 kg

pesata minima

0,5

 g

Intevallo di precarico

1,5

 kg

Divisione

0,01

 g

intervallo di tara

-15

 kg

Ripetibilita (Max)

0,015

 g

Ripetibilita (5% Max)

0,004

 g

linearita

±0,03

 g

pesata minima (U=1%,k=2)

0,82

 g

pesata minima (secondo USP)

8,2

 g

tempo di stabilizzazione

3

 s

Calibrazione

internal (automatic)

 

display

5" graphic colour

 

interfaccia

2×RS232, USB-A, USB-B, Ethernet, Wi-Fi®

 

Alimentatore

100 ÷ 240 V AC 50 / 60 Hz

 

Massimo assorbimento elettrico

0,5 A

 

temperatura di lavoro

+10 ÷ +40

 °C

Dimensioni del piatto di pesata

200×185

 mm

Packaging dimensions

520×520×280

 mm

Peso netto

10

 kg

Peso lordo

12,2

 kg

documentazione

specifiche tecniche
Publications and teaching materials
Manuals
(4.22 MB) EN
Save See the publication
Data Sheet
(1.25 MB) EN
Save See the publication
Conformity Declaration
(0.04 MB) EN
Save See the publication
PM - High Capacity Precision Balances
(3.36 MB) EN
Save See the publication

software

Drivers

RADWAG USB DRIVER 1.6.2 (1.25 MB)

Accessori

Tavoli antivibranti in marmo
tavoli antivibranti per bilance da laboratorio
tavoli antivibranti per bilance industriali
Sistema E2R
Codice a barre R
R-LAB
RAD-KEY
RADWAG Connect
Studio di sviluppo RADWAG
Driver LabVIEW
Stampanti di ricevuta
cavi IN/OUT
Cavo di alimentazione con spina per accendisigari
Cavo seriale RS 232 (connessione bilance - Stampanti EPSON)
Cavo seriale RS 232, RS 485
lettore di codici a barre
Supporto, set di montaggio a muro e braccetti di montaggio
uscita
Display
Alimentatore

Radwag bilance e sistemi di pesatura

Torunska 5
26-600 Radom
Poland
tel.: +48 48 386 60 00
e-mail: export@radwag.com
TIN: PL7960000327
Vimeo Radwag YouTube Radwag Facebook Radwag LinkedIn Radwag
© 2019 Radwag bilance e sistemi di pesatura. Diritti riservati

Watch more
RADWAG videos


movie
Radwag WEBINARS