Balance de précision PM 10.4Y

Code produit: WL-223-0002
Change the model (10)
done
Max: 10kgd: 0,01g

 200×185mm
expand_more
Max: 15kgd: 0,01g

 200×185mm
Max: 20kgd: 0,01g

 200×185mm
Max: 25kgd: 0,1g

 350×260mm
Max: 35kgd: 0,1g

 350×260mm
Max: 50kgd: 0,1g

 350×260mm
Max: 60kgd: 1g

 400×500mm
Max: 60kgd: 0,5g

 400×500mm
Max: 60kgd: 0,1g

 400×500mm
Max: 120kgd: 0,2g

 400×500mm
Capacité maximale [Max]: 10 kg
Précision de lecture: 0,01 g

close
Change the model:
Balance de précision PM 10.4Y
Balance de précision PM 15.4Y
Balance de précision PM 20.4Y
Balance de précision PM 25.4Y
Balance de précision PM 35.4Y
Balance de précision PM 50.4Y
Balance de précision PM 60.1.4Y
Balance de précision PM 60.05.4Y
Balance de précision PM 60.4Y
Balance de précision PM 120.4Y
Select all
Voir
Download
Demandez un devis
Pour Comparer Advanced Search
Description
Balances RADWAG PM – précision de laboratoire dans des conditions industrielles
  • Possibilité de peser des charges jusqu’à 120 kg  sur un grand plateau avec une grande précision et une bonne répétabilité,
  • erreur d’excentricité minimale dans toute la gamme,
  • mesure rapide et stable (réalisable en 1 seconde),
  • stabilité des paramètres dans le temps et dans le transport,
  • dimensions du plateau de pesée ajustées à la précision de la balance
sont les caractéristiques des balances RADWAG PM. Tout cela est le résultat de l’application d’un système de mesure innovant basé sur la technologie améliorée RADWAG

MONO

BLOCK®
. Le changement de la structure monobloc a permis de travailler avec une précision de 0,01 g avec une capacité de charge de 20 kg et 0,2 g avec une capacité de charge de 120 kg, une répétabilité à partir de 0,01 g et une résistance aux changements de conditions environnementales.
Les balances PM comprennent également : 
  • construction solide basée sur un monobloc plus grand et plus haut, 
  • système intégré de protection contre les surcharges à 4 points, 
  • étalonnage interne, 
  • écran tactile, 
  • mise en service facile, utilisation intuitive et ergonomie de travail, 
  • conformité avec 21 CFR Part 11,
  • degré de protection IP 54.
Pesée sous la balance
Les balances achetées après le 15 février 2023 permettront le pesage sous la balance à tout moment après l'achat du dispositif. Achetez simplement un crochet dédié.
 
Application
Les balances PM garantissent non seulement une lecture précise et une mesure rapide, mais sont également universelles et peuvent donc être utilisées dans de nombreux secteurs industriels. Le dosage, la formulation et le comptage de pièces ne sont que quelques-unes des applications possibles de ces appareils polyvalents. Les balances PM trouveront des destinataires partout où des appareils de pesage avec une grande précision et une grande capacité de charge sont nécessaires.

 
Stainless Steel in RADWAG products
Learn about the use and maintenance of stainless steel products:
Acier inoxydable dans les balances RADWAG
Paramètres Techniques
Capacité maximale [Max]

10

 kg

Capacité minimale [Min]

0,5

 g

Capacité préliminaire

1

 kg

Précision de lecture

0,01

 g

Échelon de légalisation [e]

0,1

 g

Étendue de tare

-10

 kg

Pesée minimale USP

8,2

 g

Pesée minimale (U=1%, k=2)

0,82

 g

Répétabilité (Max)

0,01

 g

Répétabilité (5% Max)

0,004

 g

Linéarité

±0,03

 g

Temps de stabilisation

3

 s

Ajustage

interne (automatique)

 

Classe de précision OIML

II

 

Système de nivellement

semi-automatique - LevelSENSING

 

Afficheur

5,7” Resistiv-Farb-Touchscreen

 

Degré de protection

IP 43

 

Dimension du plateau

200×185

 mm

Dimensions de colis

520×520×280

 mm

Masse nette

10

 kg

Masse brute

12,2

 kg

Communication interface

2×RS232, 2×USB-A, Ethernet, 4 IN / 4 OUT (digital), Wi-Fi®

 

Alimentation

Adapter: 100 – 240V AC 50/60Hz 1A; 15V DC 2,4A
Balance: 12 – 15V DC 1,1A max

 

Température du travail

+10 — +40

 °C

CE
Légalisation Extra payment
for verification
Répétabilité exprimée comme un écart standardisé de 10 placements de chargé.
Temps de stabilisation dépend de conditions externes et de la dynamique du placement d’un poids sur le plateau; déterminé pour le profil FAST.
Caractéristiques
La courbe de niveau électronique

La courbe de niveau électronique

Les possibilités fonctionnelles :
- la fonction ALARM
- l’indicateur graphique de niveau
- les tolérances programmables
Data exchange through
USB storage devices

Data exchange through
USB storage devices

- update balance software
- export weighing data
- export/import databases
- export/import balance settings
- exchange data between balances
Senseurs d’infrarouge

Senseurs d’infrarouge

Les possibilités fonctionnelles :
- la fonction PRINT
- la fonction TARA
- le régalage de la sensibilité des senseurs
Films
RADWAG Remote Desktop - Windows 10
RADWAG Remote Desktop
360°

Fonctions
Autotest

Autotest

Diagnostic function aiming at metrological parameters determination (repeatability), the parameters are determined for the actual conditions of use. When speaking of repeatability it may be also used for weighing time optimization. Autotest is operated in an automatic mode thus operator’s time is saved.
Dosing

Dosing

Weighing process for which reference mass has been determined together with tolerance for its determination. Dosing tolerance is given in [%] and it is calculated in relation to the reference value thus being a permissible deviation of this process. This solution is used for weighing powders, liquids and loose materials. Dosing function performance is often supported with bargraph - load indicator. For industrial scales it is possible to use a control systems of dosing process.
Percent Weighing

Percent Weighing

Percent Weighing function is used for comparision of measured products with mass standard. Mass of a mass standard may be a numeric value taken from a database or it may be determined through a measurement process. Each measured product is compared to mass standard, mass of which is presumed as a model 100% ideal mass. For products weighing less than the mass standard, obtained results are lower than 100%, for products weighing more, the obtained results are greatly  exceeded.
Parts counting

Parts counting

Function using mass measurement for determination of  measured items quantity. Mass of a single item is required for this process. It may be either estimated through weighment or taken from a database. For items counting the following algorithm is used: all items mass / single item mass = quantity. Function operation is supperted by a mechanism of Automatic Correction of Accuracy. This allows to update single item mass in course of the process. To a certain extend Automatic Correction of Accuracy eliminates error which may be a result of different mass values of seemingly alike single elements. For industry solutions items counting may be simultaneously carried out with checkweighing and dosing thus industry solutions feature audio signalling base informing that specified number of items has been weighed. It is possible to apply weighing systems using few platfroms of different MAX capacities and different accuracies.
Formulation

Formulation

Function supporting the mixture making process, wherein the mixture contains various components. Formulation function usually uses the balance/scale database of components. Formulation serves for monitored checkweighing of every single component with a given tolerance. It is enriched with a set of individual settings.
Statistics

Statistics

Statistiscs function registers and analyses performed measurements. This supplies the user withthe following information: Max and Min standard deviation, average value, variance, range et.
Checkweighing

Checkweighing

Checkweighing function is used for checking whether the measured sample mass is within the predefined threshold values, Low [LO] and Hgh [HI]. The thresholds are given in [g] and [kg] units. Current state of a sample being measured is signalled by means of pictorgams located on a display for laboratory balances, for industrial scales Stackligt System is used. This visual +/- inspection is in operation during segregation, control or packing process of products for which mass has bees determined with a specifaied tolerance, eg. 12860 g 961
IR sensors

IR sensors

Programmable function supporting the weighing process through control of the following options: sliding weighing chamber doors, printout, zeroing, tarring etc. Especially appreciated wherever preventing the balance from soiling is important.
GLP Procedures

GLP Procedures

Diagnostic function allowing to objectively document performed measurements. GLP procedures may be either presented in a short report form or extended one.
Animal weighing

Animal weighing

Process of mass determination for a product which may unwillingly reposition within the weighing pan. Mass determination in such cases requires much longer period of time when compared to typical weighing process. It is the user who defines period of time needed for control of measured product mass. The user can thus optimize the function depending on the measured product characteristics.
Density determination

Density determination

Liquid or solid body density function uses the Archimedes principle and it requires a special kit to be applied. The kit when used, replaces a weighing pan. For solids mass of the sample must be determined first in the air, next in the liquid of specified density. For liquids the so called sinker, density of which has been determined, must be measured first in the air, next in the tested liquid. The density determination process is disturbed by air bubbles which may stick either to the measured sample or the sinker. In case of laboratory equipment very light solids may be measured. For industry, solid bodies density may be determined by means of  under-pan weighing. Tested load of significant size may be measured this way.
Differential weighing

Differential weighing

Differential weighing informs about mass variation a particular sample, wherein the said variation is a result of manufacturing processes.

Differential weighing is often applied in product control process, for which reference product parameters have been specified in order to be used as a source of comparison for the whole series.
Insuchcasestandard deviation is the information which tells about quality and completeness of a final product. For systems based on a feed-back technique such information may be used by control units.
Statistical Quality Control

Statistical Quality Control

Statistical control for determination of basic statistical criteria: maximum, minimum, standard deviation, mean values for each batch, etc.
Documentation
Cartes de produits
Data Sheet Data Sheet
Data Sheet

Voir
Voir
Download
Download

Choose more product:
Voir Voir DownloadDownload
Modes d'emploi
Mode d'emploi - PM 4Y
Mode d'emploi - PM 4Y
Voir
Voir
Download
Download
(3.74 MB)
Software Manual - Radwag-Mass -Node-RED
Software Manual - Radwag-Mass -Node-RED
Voir
Voir
Download
Download
(0.57 MB)
Start up Guide
Start up Guide
Voir
Voir
Download
Download
(1.92 MB)
Déclarations de conformité
Conformity Declaration
Conformity Declaration
Voir
Voir
Download
Download
(0.04 MB)
Publications et brochures
PM Precision Balances
PM Precision Balances
Voir
Voir
Download
Download
(5.49 MB)
Systeme THBR 2.0
Systeme THBR 2.0
Voir
Voir
Download
Download
(5.24 MB)
Acier inoxydable dans les balances RADWAG
Acier inoxydable dans les balances RADWAG
Voir
Voir
Download
Download
(2.46 MB)
Profils Definis de Pesage
Profils Definis de Pesage
Voir
Voir
Download
Download
(1.63 MB)
Accessoires
Imprimante de tickets de caisse
Afficheurs
Lecteurs de code-barres
Câbles RS 232 (balance – imprimante)

Accessoires

Câbles RS 232, RS 485
Convertisseur RS 232 – USB
Concentrateurs USB

Accessoires

Alimentateurs
Écran de protection anti-poussière
Pesage sous la balance
R-LAB

Accessoires

E2R System
Éditeur D’étiquettes R02
RADWAG Studio du Développement
Pilote LabVIEW
RADWAG Remote Desktop
RAD KEY

Accessoires

R.Barcode

Accessoires

Audit Trail Reader
Tables antivibratoires
Imprimantes d étiquettes
Modules
Module de conformité à 21 CFR partie 113
Radwag Balances Électroniques
Torunska 5
26-600 Radom
Poland
tel.: +48 48 386 60 00
e-mail: export@radwag.com
TIN: PL7960000327
Vimeo Radwag YouTube Radwag Facebook Radwag LinkedIn Radwag
© 2023 RADWAG Balances Électroniques. Tous les droits sont réservés.

Wybierz język

×
Change language AlbanianAlbanian
Change language DanishDanish
Change language NederlandseNederlandse
Change language EstonianEstonian
Change language FinnishFinnish
Change language HungarianHungarian
Change language IcelandicIcelandic
Change language KazakhKazakh
Change language LatvianLatvian
Change language LithuanianLithuanian
Change language MacedonianMacedonian
Change language NorwegianNorwegian
Change language PortuguesePortuguese
Change language RomanianRomanian
Change language RussianRussian
Change language SlovakSlovak
Change language SlovenianSlovenian
Change language SwedishSwedish
Change language UkrainianUkrainian
Change language SerbianSerbian
Change language MontenegrinMontenegrin
Change language page on Deutsch Deutsch
Change language page on English English
Change language page on Español Español
Change language page on Italiano Italiano
Change language page on Polski Polski
Change language page on Türkiye Türkiye
Česky
Change website to USA USA
Change language page on 中文 中文
SubscribeSubscribe
Radwag in FacebookFacebook
Radwag in YouTubeRadwag in YouTubeYoutube
Radwag in VimeoVimeo
Radwag in LinkedInLinkedIn
Webinars RadwagWebinars
close
E-mail:
Nom de l’entreprise :
Prénom:
I consent to the processing of my personal data for marketing purposes by Radwag Wagi Elektroniczne Witold Lewandowski.
I consent to receive marketing and product-related messages by electronic means from Radwag Wagi Elektroniczne Witold Lewandowski.
I have read the Privacy Policy of RADWAG Wagi Elektroniczne Witold Lewandowski.
lock_openI want to access the files
close
Slide to go back ↩