done
Max: 0,8 / 3gd: 1 / 10µg

 ø16 + ø60 (pour les filtres)mm
expand_more
Max: 2,1gd: 1µg

 ø16mm
Max: 5,1gd: 1µg

 ø26mm
Max: 6,1gd: 1µg

 ø26mm
Max: 11 / 52gd: 1 / 10µg

 ø26 / ø40mm
Max: 11gd: 1µg

 ø26mm
Max: 21 / 52gd: 1 / 10µg

 ø26 / ø40mm
Max: 21gd: 1µg

 ø26mm
Max: 31gd: 1µg

 ø26mm
Description
La plus grande vitesse de mesures grâce à nouveau CPU Les balances 4Y équipées de processeur Dual Core 2x 1GHz offrent de nouvelles possibilités de vitesses de... więcej ››
Capacité maximale [Max]: 0,8 / 3g
Précision de lecture: 1 / 10µg

close
Select model:
Microbalance MYA 0,8/3.4Y
Microbalance MYA 2.4Y
Microbalance MYA 5.4Y
Microbalance MYA 6.4Y
Microbalance MYA 11/52.4Y
Microbalance MYA 11.4Y
Microbalance MYA 21/52.4Y
Microbalance MYA 21.4Y
Microbalance MYA 31.4Y
Select all
Voir
Download
Demandez un devis
Description
La plus grande vitesse de mesures grâce à nouveau CPU Les balances 4Y équipées de processeur Dual Core 2x 1GHz offrent de nouvelles possibilités de vitesses de travail. Elles assurent une stabilité du résultat et sa répétabilité dans une courte période.

Mémoire 16 GB – nouvelles possibilitées de gestion de données L’augmentation de mémoire de la balance jusqu’à 16 GB donne la possibilité d’enregistrer de données en forme de rapports avancés et de visualisations de diagrammes temporaires et statistiques venant de série de pesages.

La plus grande répétabilité et conformité avec USP La plus grande précision de pesage, la répétabilié de sorte que : sd ≤ 1d et la conformité avec exigences USP (les chapitres 41 et 1251) font des balances 4Y le nouvel indicateur de qualité de mesures de masse.

Ergonomie et sécurité de travail La communication sans fil entre le terminal de balance et l’unité de pesage permet l’exploitation des balances 4Y dans les chambres à flux laminaire et les hottes fermées de laboratoire.

Desservice mobile Le Wireless Connection offre la possibilité du transfert de données des balances 4Y aux outils mobiles iOS ou Android, en profitant d’applications spéciales pour la gestion de données.

Sécurité de données Toutes les balances de série 4Y possèdent la mémoire ALIBI qui garantit la sécurité, l’enregistrement automatique de mesures et la possibilité de revoir, de copier et d’archiver de données.

Possibilité du pesage des filtres La solution innovante de construction rend possible l’échange de la chambre de pesage dans la microbalance MYA 4Y contre la chambre de pesage des filtres, c’est-à-dire l’extension de la fonctionnalité de l’appareil. La chambre de pesage des filtres se caractérise par une étanchéité élevée. Le grand plateau ajouré permet de peser avec précision des filtres de différentes tailles (ø100 max.). Il est fabriqué en acier inoxydable résistant aux produits chimiques, à la décoloration et aux rayures. La chambre pour peser les filtres n’ appartient pas à l’équipement standard de la microbalance MYA 4Y.
Profils définis
Quatre ensembles prédéfinis des paramètres de la balance adaptent automatiquement les paramètres de la balance aux besoins et aux préférences de l'utilisateur.
  • FAST – on obtient la mesure dans très peu de temps,
  • FAST DOSING – balance passera au mode de réaction très rapide au changement de masse, particulièrement utile lors du dosage ou de l'ajout d'une masse suivante à la portion mesurée,
  • PRECISION – réglages de la balance sont liés à l'écart type minimal,
  • USER – permet à l'utilisateur de définir individuellement les paramètres de balance.
Remarque:
Pour la réalisation correcte du processus du pesage à l'aide des ultra-microbalances et des microbalances, il faut les servir de façon convenable et préparer correctement le lieu du travail.
On peut trouver les exigences concernant l'installation et l'utilisation dans le document sous le lien: Conditions de l'installation et de l'utilisation des ultra-microbalances et des microbalances.
Stainless Steel in RADWAG products
Learn about the use and maintenance of stainless steel products:
Acier inoxydable dans les balances RADWAG
Paramètres Techniques
Capacité maximale [Max]

0,8 / 3

 g

Capacité minimale [Min]

100

 µg

Précision de lecture

1 / 10

 µg

Étendue de tare

-3

 g

Échelon de légalisation [e]

1

 mg

Répétabilité standard [5% Max]

0,6

 µg

Répétabilité standard [Max]

4,1

 µg

Répétabilité admissible [5% Max]

1,2

 µg

Répétabilité admissible [Max]

6

 µg

Linéarité

±3 / 10

 µg

Non-centricité

3 / 10

 µg

Temps de stabilisation

max 8

 s

Ajustage

interne (automatique)

 

Classe de précision OIML

I

 

Poids minimal d’echantillon standard (USP)

1,2

 mg

Poids minimal d’echantillon standard (U=1%, k=2)

0,12

 mg

Degré de protection

IP 43

 

Système de nivellement

semi-automatique - LevelSENSING

 

Afficheur

5,7” résistant couleurs tactile

 

Dimensions de la chambre de pesée

ø90×90

 mm

Dimension du plateau

ø16 + ø60 (pour les filtres)

 mm

Dimensions de colis

660×660×455

 mm

Masse nette

9,1

 kg

Masse brute

16,6

 kg

Communication interface

2×RS232, 2×USB-A, Ethernet, 4 IN / 4 OUT (digital), Wi-Fi®

 

Alimentation

100 — 240 V AC 50 / 60 Hz

 

Prise de courant maximale

10 W

 

Température du travail

+10 — +40

 °C

Vitesse de changements de température de travail

±0,3°C/1h (±1°C/8h)

 

Humidité relative d'air

40% — 80%

 

Vitesse de changements d'humidité relative d'air

±1%/h (±4%/8h)

 

Répétabilité exprimée comme un écart standardisé de 10 placements de chargé.
Temps de stabilisation dépend de conditions externes et de la dynamique du placement d’un poids sur le plateau; déterminé pour le profil FAST.
Caractéristiques
La courbe de niveau électronique

La courbe de niveau électronique

Les possibilités fonctionnelles :
- la fonction ALARM
- l’indicateur graphique de niveau
- les tolérances programmables
Data exchange through
USB storage devices

Data exchange through
USB storage devices

- update balance software
- export weighing data
- export/import databases
- export/import balance settings
- exchange data between balances
Senseurs d’infrarouge

Senseurs d’infrarouge

Les possibilités fonctionnelles :
- la fonction PRINT
- la fonction TARA
- le régalage de la sensibilité des senseurs
La communication sans fil

La communication sans fil

Application :
  1. Élimination des sources supplémentaires des vibrations
    Le placement du terminal hors de la table de balance : - élimine les vibrations et les tremblements étant les résultats de son utilisation - permet le travail stable des balances de hautes résolutions sans la nécessité d’application des postes de balance spéciaux.
  2. le confort de pesage dans les hottes fermées et dans les chambres laminaires
    La communication sans fil du terminal avec le module de pesage permet l’application plus confortable et en sécurité de la balance de laboratoire dans les hottes fermées.
  3. Isolement de la balance des conditions atmosphériques défavorables
    La communication sans fil rend possible la mise en place du module de balance dans les boîtes anti-courant d’air ou son isolement complet de l’opérateur. Grâce a cela, il peut peser les substances polluées ou toxiques sans l’exposition de sa vie ou de sa santé aux dangers.
Interface de communication

Interface de communication

- Ethernent
- 2× ; USB
- 2× ; RS 232
- 4 entrées / 4 sorties
- WiFi 2,4 GHz b,g,n
Films
New weighing chamber for MYA.4Y and UYA.4Y microbalances
4y series - Ultra-microbalances and microbalances
RADWAG Remote Desktop - Windows 10
RADWAG Remote Desktop
4Y Balances: Video-Guidance and an on-screen manuals
4Y Series RADWAG Balances
Fonctions
Autotest

Autotest

Diagnostic function aiming at metrological parameters determination (repeatability), the parameters are determined for the actual conditions of use. When speaking of repeatability it may be also used for weighing time optimization. Autotest is operated in an automatic mode thus operator’s time is saved.
Dosing

Dosing

Weighing process for which reference mass has been determined together with tolerance for its determination. Dosing tolerance is given in [%] and it is calculated in relation to the reference value thus being a permissible deviation of this process. This solution is used for weighing powders, liquids and loose materials. Dosing function performance is often supported with bargraph - load indicator. For industrial scales it is possible to use a control systems of dosing process.
Percent Weighing

Percent Weighing

Percent Weighing function is used for comparision of measured products with mass standard. Mass of a mass standard may be a numeric value taken from a database or it may be determined through a measurement process. Each measured product is compared to mass standard, mass of which is presumed as a model 100% ideal mass. For products weighing less than the mass standard, obtained results are lower than 100%, for products weighing more, the obtained results are greatly  exceeded.
Parts counting

Parts counting

Function using mass measurement for determination of  measured items quantity. Mass of a single item is required for this process. It may be either estimated through weighment or taken from a database. For items counting the following algorithm is used: all items mass / single item mass = quantity. Function operation is supperted by a mechanism of Automatic Correction of Accuracy. This allows to update single item mass in course of the process. To a certain extend Automatic Correction of Accuracy eliminates error which may be a result of different mass values of seemingly alike single elements. For industry solutions items counting may be simultaneously carried out with checkweighing and dosing thus industry solutions feature audio signalling base informing that specified number of items has been weighed. It is possible to apply weighing systems using few platfroms of different MAX capacities and different accuracies.
Formulation

Formulation

Function supporting the mixture making process, wherein the mixture contains various components. Formulation function usually uses the balance/scale database of components. Formulation serves for monitored checkweighing of every single component with a given tolerance. It is enriched with a set of individual settings.
Statistics

Statistics

Statistiscs function registers and analyses performed measurements. This supplies the user withthe following information: Max and Min standard deviation, average value, variance, range et.
Checkweighing

Checkweighing

Checkweighing function is used for checking whether the measured sample mass is within the predefined threshold values, Low [LO] and Hgh [HI]. The thresholds are given in [g] and [kg] units. Current state of a sample being measured is signalled by means of pictorgams located on a display for laboratory balances, for industrial scales Stackligt System is used. This visual +/- inspection is in operation during segregation, control or packing process of products for which mass has bees determined with a specifaied tolerance, eg. 12860 g 961
IR sensors

IR sensors

Programmable function supporting the weighing process through control of the following options: sliding weighing chamber doors, printout, zeroing, tarring etc. Especially appreciated wherever preventing the balance from soiling is important.
GLP Procedures

GLP Procedures

Diagnostic function allowing to objectively document performed measurements. GLP procedures may be either presented in a short report form or extended one.
Animal weighing

Animal weighing

Process of mass determination for a product which may unwillingly reposition within the weighing pan. Mass determination in such cases requires much longer period of time when compared to typical weighing process. It is the user who defines period of time needed for control of measured product mass. The user can thus optimize the function depending on the measured product characteristics.
Air density correction

Air density correction

Function performing correction of mass measurement indication, wherein the air density is taken into account. It is used in balances with reading unit < 0,01 mg.
Automatic sliding door

Automatic sliding door

Automatic side panes opened via touch-free IR sensors.
Moveable range

Moveable range

Dual range analytical balances can be equipped with much more precise measuring range but only in very limited part of max capacity and only from zero load. A new technology introduced by RADWAG allows for moving this limited range till max capacity of the balance is reached. Such solution has been named as: Moveable range.
Differential weighing

Differential weighing

Differential weighing informs about mass variation a particular sample, wherein the said variation is a result of manufacturing processes.

Differential weighing is often applied in product control process, for which reference product parameters have been specified in order to be used as a source of comparison for the whole series.
Insuchcasestandard deviation is the information which tells about quality and completeness of a final product. For systems based on a feed-back technique such information may be used by control units.
Ambient conditions monitoring

Ambient conditions monitoring

The possibility of cooperation with the THBR 2.0 system
Replaceable unit

Replaceable unit

Replaceable units.
Statistical Quality Control

Statistical Quality Control

Statistical control for determination of basic statistical criteria: maximum, minimum, standard deviation, mean values for each batch, etc.
ALIBI Memory

ALIBI Memory

"ALIBI" memory enables saving and storing up to 100000 measurements.  Measurements are saved automatically upon each pressing of the key. There is no need for any additional operations or changing settings.
The following data related with the measurements is saved: measurement date; measurement time; result (mass); tare value; operator carrying out the measurement (logged in); product name.
The software saves the measurement in a so called loop, i.e. when the measurement no. 100001 is saved, the measurement 1 gets automatically deleted from the memory.
Measurements saved to balance memory cannot be deleted.
You can preview and print out the data saved to the ALIBI database.
Wi-Fi®

Wi-Fi®

Wi-Fi® offers possibility to send data from balance to a mobile iOS or Android device, via special data management apps. Wireless communication between the indicator and the weighing instrument enables operating the balance that is placed inside a laminar flow hood or a fume cupboard.
Documentation
Cartes de produits
Data Sheet

This product:

Voir

Download

For the group:
Voir Download
Modes d'emploi
Mode d'emploi - Balances de la série 4Y

Voir

Download
(5.75 MB)
Software Manual - Radwag-Mass -Node-RED

Voir

Download
(0.57 MB)
Start up Guide

Voir

Download
(3.51 MB)
Déclarations de conformité
Conformity Declaration

Voir

Download
(0.04 MB)
Publications et brochures
Principles of Metrology

Voir

Download
(0.10 MB)
Determination of Total And Respirable Air

Voir

Download
(0.21 MB)
Autotest

Voir

Download
(0.10 MB)
Conditions environnementales pour Microbalance

Voir

Download
(0.83 MB)
Influence of seismic on measuring accuracy of electronic weighing instruments

Voir

Download
(0.55 MB)
Detection of vibrations at the electronic balances workstation

Voir

Download
(2.02 MB)
Systeme THBR 2.0

Voir

Download
(5.24 MB)
Balances de la serie 4Y

Voir

Download
(24.03 MB)
Micro Scale Measurement

Voir

Download
(2.74 MB)
Acier inoxydable dans les balances RADWAG

Voir

Download
(2.46 MB)
4Y Nouvelle série des balances de laboratoire

Voir

Download
(2.03 MB)
Profils Definis de Pesage

Voir

Download
(1.63 MB)
Documentation technique
Microbalances working conditions

Voir

Download
(2.25 MB)
Accessoires
Tables antivibratoires pour balances de laboratoire
Table professionnel de balance
Audit Trail Reader
E2R System

Accessoires

Éditeur D’étiquettes R02
R.Barcode

Accessoires

R-LAB

Accessoires

RAD KEY

Accessoires

RADWAG Connect

Accessoires

RADWAG Studio du Développement
RADWAG Remote Desktop
Pilote LabVIEW
Chambre pour peser les filtres
Imprimante de tickets de caisse
Imprimantes d étiquettes
Ioniseurs
THBR 2.0 - Monitorage des conditions environnementales
Câbles RS 232, RS 485
Concentrateurs USB

Accessoires

Convertisseur RS 232 – USB
Câbles RS 232 (balance – imprimante EPSON)

Accessoires

Écran de protection anti-poussière
Lecteurs de code-barres
Boîte pour microbalances
Afficheurs
Alimentateurs
Modules
Module de conformité à 21 CFR partie 113
Radwag Balances Électroniques
Torunska 5
26-600 Radom
Poland
tel.: +48 48 386 60 00
e-mail: export@radwag.com
TIN: PL7960000327
Vimeo Radwag YouTube Radwag Facebook Radwag LinkedIn Radwag
© 2021 RADWAG Balances Électroniques. Tous les droits sont réservés.

Wybierz język

×
Change language AlbanianAlbanian
Change language DanishDanish
Change language NederlandseNederlandse
Change language EstonianEstonian
Change language FinnishFinnish
Change language HungarianHungarian
Change language IcelandicIcelandic
Change language KazakhKazakh
Change language LatvianLatvian
Change language LithuanianLithuanian
Change language MacedonianMacedonian
Change language NorwegianNorwegian
Change language PortuguesePortuguese
Change language RomanianRomanian
Change language RussianRussian
Change language SlovakSlovak
Change language SlovenianSlovenian
Change language SwedishSwedish
Change language UkrainianUkrainian
Change language SerbianSerbian
Change language MontenegrinMontenegrin
Change language page on Deutsch Deutsch
Change language page on English English
Change language page on Español Español
Change language page on Italiano Italiano
Change language page on Polski Polski
Change language page on Türkiye Türkiye
Česky
Change website to USA USA
Change language page on 中文 中文
Subscribe
Facebook
Youtube
Vimeo
LinkedIn
Webinars
close