Pour Comparer : Balance pèse-personne WPT 100/200 OW

Selected language Français Français
Change language
Change language page on Deutsch DeutschChange language page on English EnglishChange language page on Español EspañolChange language page on Italiano ItalianoChange language page on Polski PolskiChange language page on Türkiye Türkiye ČeskyChange website to USA USAChange language page on 中文 中文

Balance pèse-personne WPT 100/200 OW

Balance pèse -   La balance pèse-personne est equipée de terminal PUE C/31 avec un afficheur rétroéclairé LCD. La balance médicale de série OW possède la possibilité d’une indication d’une masse d’un corps BMI (Body Mass Index) adapté pour les personnes adultes de taille au-dessus de 1 mètre
This image is for reference only.

Code produit: WM-004-1007
Poser des questions sur le produit

Description

Capacité maximale [Max]: 100 / 200kg
Précision de lecture: 50 / 100g

La

balance

pèse-personne est conçue pour le pesage de patients profitant de services de différentes institutions médicales. À l’aide d’un stadiomètre on peut mesurer un patient de taille jusqu’à 2 mètres. 

La

balance

pèse-personne est equipée de terminal PUE C/31 avec un afficheur rétroéclairé LCD.

La balance médicale de série OW possède la possibilité d’une indication d’une masse d’un corps BMI (Body Mass Index) adapté pour les personnes adultes de taille au-dessus de 1 mètre. L’indicateur BMI est indiqué après un enregistrement d’une mesure de taille dans le système informatique de balance. La taille est lu sur le stadiomètre.
 
 

Fonctions

Plus/Minus Control

Plus/Minus Control

Control of sample's mass carried out with reference to specified MIN and MAX thresholds. The weight is considered to be correct if it is comprised within threshold values. A graphic visualisation of weighing result is displayed in a form of a bar graph.
Percent Weighing

Percent Weighing

Percent Weighing function is used for comparision of measured products with mass standard. Mass of a mass standard may be a numeric value taken from a database or it may be determined through a measurement process. Each measured product is compared to mass standard, mass of which is presumed as a model 100% ideal mass. For products weighing less than the mass standard, obtained results are lower than 100%, for products weighing more, the obtained results are greatly  exceeded.
Totalizing

Totalizing

Function adding new mass value to already obtained one. This allows to determine mass content of the mixture, being a composition of number of different consistence components. Totalizing is limited by maximum capacity parameter.
Parts counting

Parts counting

Function using mass measurement for determination of  measured items quantity. Mass of a single item is required for this process. It may be either estimated through weighment or taken from a database. For items counting the following algorithm is used: all items mass / single item mass = quantity. Function operation is supperted by a mechanism of Automatic Correction of Accuracy. This allows to update single item mass in course of the process. To a certain extend Automatic Correction of Accuracy eliminates error which may be a result of different mass values of seemingly alike single elements. For industry solutions items counting may be simultaneously carried out with checkweighing and dosing thus industry solutions feature audio signalling base informing that specified number of items has been weighed. It is possible to apply weighing systems using few platfroms of different MAX capacities and different accuracies.
Internal battery

Internal battery

Internal and rechargeable battery of SLA 6 V type (sealed lead acid) enables device operation without connecting the device to the mains (9h operation). The weighing instrument controls battery status and displays a respective pictogram on the screen.
Peak hold

Peak hold

Function registering the greatest temporary indication occurring in course of the weighing process. It is most often used in medical scales in order to hold the measurement indication.
Animal weighing

Animal weighing

Process of mass determination for a product which may unwillingly reposition within the weighing pan. Mass determination in such cases requires much longer period of time when compared to typical weighing process. It is the user who defines period of time needed for control of measured product mass. The user can thus optimize the function depending on the measured product characteristics.

Paramètres Techniques

Capacité maximale [Max]

100 / 200

 kg

Précision de lecture

50 / 100

 g

Étendue de tare

-200

 kg

Afficheur

LCD (rétro-éclairé)

 

Communication interface

RS232

 

Alimentation

100 ÷ 240 V AC 50 / 60 Hz + accumulateur

 

Temps de travail avec l'alimentation d'accumulateur

35 heures (temps moyen)

 

Température du travail

0 ÷ +40

 °C

Humidité relative d'air

10% ÷ 85% RH sans condensation

 

Documentation

Documentation technique
Publications et Matériaux Pédagogiques
Mode d'emploi
(1.27 MB)
Save See the publication
Fiche technique
(0.34 MB)
Save See the publication
Conformity Declaration
(0.04 MB) EN
Save See the publication

Accessoires

R-LAB
RAD KEY
Pilote LabVIEW
Imprimante de tickets de caisse
Câbles RS 232 (balance – imprimante EPSON)
Câbles RS 232, RS 485
Câbles d'alimentation de cigare-allume
Afficheurs

Accessoires

Nom De Produit

Description

Afficheur supplémentaire WD-4/1

...

Convertisseur RS232 – RS485
Convertisseur RS232 – Ethernet
Sorties de boucle de courant

Radwag Balances Électroniques

Torunska 5
26-600 Radom
Poland
tel.: +48 48 386 60 00
e-mail: export@radwag.com
TIN: PL7960000327
Vimeo Radwag YouTube Radwag Facebook Radwag LinkedIn Radwag
© 2019 RADWAG Balances Électroniques. Tous les droits sont réservés.

Watch more
RADWAG videos


movie
Radwag WEBINARS