Balance mono capteur C315.1,5.F1.K

Balance mono capteur C315.1,5.F1.K - RADWAG Balances Électroniques est l'un des principaux fabricants de balances électroniques, de comparateurs de masse et d'accessoires pour de nombreuses industries.
This image is for reference only.

Code produit: WP-123-0002
Poser des questions sur le produit

Description

Capacité maximale [Max]: 1,5kg
Précision de lecture: 0,5g

Platform

scales

C315 series is designed for direct trade. It is used wherever fast and precise determination of net

weight

is required.

The C315 series features an

indicator

PUE C315 series comprising backlit LCD display.

C315

scales

is manufactured using powder coated mild steel profiles, with stainless steel

weighing

platform.

Scales C315 series is available in dual range version on surcharge.

Fonctions

Plus/Minus Control

Plus/Minus Control

Control of sample's mass carried out with reference to specified MIN and MAX thresholds. The weight is considered to be correct if it is comprised within threshold values. A graphic visualisation of weighing result is displayed in a form of a bar graph.
Percent Weighing

Percent Weighing

Percent Weighing function is used for comparision of measured products with mass standard. Mass of a mass standard may be a numeric value taken from a database or it may be determined through a measurement process. Each measured product is compared to mass standard, mass of which is presumed as a model 100% ideal mass. For products weighing less than the mass standard, obtained results are lower than 100%, for products weighing more, the obtained results are greatly  exceeded.
Totalizing

Totalizing

Function adding new mass value to already obtained one. This allows to determine mass content of the mixture, being a composition of number of different consistence components. Totalizing is limited by maximum capacity parameter.
Parts counting

Parts counting

Function using mass measurement for determination of  measured items quantity. Mass of a single item is required for this process. It may be either estimated through weighment or taken from a database. For items counting the following algorithm is used: all items mass / single item mass = quantity. Function operation is supperted by a mechanism of Automatic Correction of Accuracy. This allows to update single item mass in course of the process. To a certain extend Automatic Correction of Accuracy eliminates error which may be a result of different mass values of seemingly alike single elements. For industry solutions items counting may be simultaneously carried out with checkweighing and dosing thus industry solutions feature audio signalling base informing that specified number of items has been weighed. It is possible to apply weighing systems using few platfroms of different MAX capacities and different accuracies.
Internal battery

Internal battery

Internal and rechargeable battery of SLA 6 V type (sealed lead acid) enables device operation without connecting the device to the mains (9h operation). The weighing instrument controls battery status and displays a respective pictogram on the screen.
Peak hold

Peak hold

Function registering the greatest temporary indication occurring in course of the weighing process. It is most often used in medical scales in order to hold the measurement indication.
GLP Procedures

GLP Procedures

Diagnostic function allowing to objectively document performed measurements. GLP procedures may be either presented in a short report form or extended one.
Animal weighing

Animal weighing

Process of mass determination for a product which may unwillingly reposition within the weighing pan. Mass determination in such cases requires much longer period of time when compared to typical weighing process. It is the user who defines period of time needed for control of measured product mass. The user can thus optimize the function depending on the measured product characteristics.
ALIBI Memory

ALIBI Memory

"ALIBI" memory enables saving and storing up to 100000 measurements.  Measurements are saved automatically upon each pressing of the key. There is no need for any additional operations or changing settings.
The following data related with the measurements is saved: measurement date; measurement time; result (mass); tare value; operator carrying out the measurement (logged in); product name.
The software saves the measurement in a so called loop, i.e. when the measurement no. 100001 is saved, the measurement 1 gets automatically deleted from the memory.
Measurements saved to balance memory cannot be deleted.
You can preview and print out the data saved to the ALIBI database.

Paramètres Techniques

Capacité maximale [Max]

1,5

 kg

Capacité minimale [Min]

10

 g

Précision de lecture

0,5

 g

Étendue de tare

-1,5

 kg

Échelon de légalisation [e]

0,5

 g

Précision de lecture maximale pour la balance vérifiée

0,2

 g

Classe de précision OIML

III

 

Afficheur

LCD (rétro-éclairé)

 

Degré de protection

IP 65 construction, IP 43 terminal

 

Interface RS232

1× standard, 1× en option

 

Interface Wi-Fi®

1× standard

 

Alimentation

100 ÷ 240 V AC 50 / 60 Hz + accumulateur

 

Prise de courant maximale

5 W

 

Temps de travail avec l'alimentation d'accumulateur

max 8h

 

Température du travail

-10 ÷ +40

 °C

Température de stockage

-10 ÷ +50

 °C

Humidité relative d'air

10% ÷ 85% RH sans condensation

 

Terminal

C315

 

Construction

Stal malowana proszkowo St3S

 

Matériel du plateau

acier inoxydable AISI304

 

Dimension du plateau

300×300

 mm

Dimensions de colis

570×390×170

 mm

Masse nette

5,3

 kg

Masse brute

6,1

 kg

Documentation

Documentation technique
Publications et Matériaux Pédagogiques
User Manual
(0.98 MB) EN
Save See the publication
Manuals
(0.30 MB) EN
Save See the publication
Data Sheet
(0.90 MB) EN
Save See the publication
Conformity Declaration
(0.04 MB) EN
Save See the publication
C315 Platform Scales
(2.13 MB) EN
Save See the publication
Measuring_instruments_in_industry
(0.05 MB) EN
Save See the publication

Accessoires

Tables antivibratoires en granite
Éditeur de Balances 2.0
RW Tool
R-LAB
RAD KEY
Pilote LabVIEW
Imprimante de tickets de caisse
Câbles RS 232 (balance – imprimante EPSON)
Câbles RS 232, RS 485
Câbles d'alimentation de cigare-allume
Supports, Statifs, bras-supports
Convertisseur RS232 – RS485
Convertisseur RS232 – Ethernet
Sorties de boucle de courant
Afficheurs

Radwag Balances Électroniques

Torunska 5
26-600 Radom
Poland
tel.: +48 48 386 60 00
e-mail: export@radwag.com
TIN: PL7960000327
Vimeo Radwag YouTube Radwag Facebook Radwag
© 2019 RADWAG Balances Électroniques. Tous les droits sont réservés.

Watch more
RADWAG videos

movie
Radwag WEBINARS