Para comparar : Indicador PUE C315

Selected language Español Español
Change language
Change language page on Deutsch DeutschChange language page on English EnglishChange language page on Français FrançaisChange language page on Italiano ItalianoChange language page on Polski PolskiChange language page on Türkiye Türkiye ČeskyChange website to USA USAChange language page on 中文 中文

Indicador PUE C315

Indicador PUE C315 - Funciones de terminal de pesaje PUE C315: Unidades de medida: [g], [kg], [N], [ct], [lb]; Taraje en todo rango de medición; Tara automática, memoria de tara; Contaje de piezas con la misma masa; +/- control de la masa con el estándar del sistema; Desviación de porcentaje con relación a la masa de referencia, Promediado de resultado de pesaje, filtro digital; Control de alimentación de baterías; Apagado del temporizador de balanza; Luz de fondo ajustable en la alimentación de las baterías; Velocidad de transmisión ajustable entre 200-38400bit/s, Transmisión continua de datos a través de RS 232; Modo manual o automático para RS 232; Pesaje de cargas con la función auto cero desactivada; Medida de la fuerza máxima o de la masa máxima colocada en el platillo de pesaje; Medida de la fuerza que influye en el platillo de pesaje (en Newtons); Control de la masa inicial; Posibilidad para conectar una pantalla LCD adicional; Resumiendo el pesaje. La posibilidad de diseñar impresiones de acuerdo a las necesidades individuales
This image is for reference only.

Código de producto: WX-008-0150
Preguntar sobre producto

Descripción

Funciones de terminal de pesaje PUE C315:
  • Unidades de medida: [g], [kg], [N], [ct], [lb];
  • Taraje en todo rango de medición;
  • Tara automática, memoria de tara;
  • Contaje de piezas con la misma masa;
  • +/- control de la masa con el estándar del sistema;
  • Desviación de porcentaje con relación a la masa de referencia,
  • Promediado de resultado de pesaje, filtro digital;
  • Control de alimentación de baterías;
  • Apagado del temporizador de balanza;
  • Luz de fondo ajustable en la alimentación de las baterías;
  • Velocidad de transmisión ajustable entre 200-38400bit/s,
  • Transmisión continua de datos a través de RS 232;
  • Modo manual o automático para RS 232;
  • Pesaje de cargas con la función auto cero desactivada;
  • Medida de la fuerza máxima o de la masa máxima colocada en el platillo de pesaje;
  • Medida de la fuerza que influye en el platillo de pesaje (en Newtons);
  • Control de la masa inicial;
  • Posibilidad para conectar una pantalla LCD adicional;
  • Resumiendo el pesaje.
La posibilidad de diseñar impresiones de acuerdo a las necesidades individuales.

Funciones

Plus/Minus Control

Plus/Minus Control

Control of sample's mass carried out with reference to specified MIN and MAX thresholds. The weight is considered to be correct if it is comprised within threshold values. A graphic visualisation of weighing result is displayed in a form of a bar graph.
Percent Weighing

Percent Weighing

Percent Weighing function is used for comparision of measured products with mass standard. Mass of a mass standard may be a numeric value taken from a database or it may be determined through a measurement process. Each measured product is compared to mass standard, mass of which is presumed as a model 100% ideal mass. For products weighing less than the mass standard, obtained results are lower than 100%, for products weighing more, the obtained results are greatly  exceeded.
Totalizing

Totalizing

Function adding new mass value to already obtained one. This allows to determine mass content of the mixture, being a composition of number of different consistence components. Totalizing is limited by maximum capacity parameter.
Parts counting

Parts counting

Function using mass measurement for determination of  measured items quantity. Mass of a single item is required for this process. It may be either estimated through weighment or taken from a database. For items counting the following algorithm is used: all items mass / single item mass = quantity. Function operation is supperted by a mechanism of Automatic Correction of Accuracy. This allows to update single item mass in course of the process. To a certain extend Automatic Correction of Accuracy eliminates error which may be a result of different mass values of seemingly alike single elements. For industry solutions items counting may be simultaneously carried out with checkweighing and dosing thus industry solutions feature audio signalling base informing that specified number of items has been weighed. It is possible to apply weighing systems using few platfroms of different MAX capacities and different accuracies.
Internal battery

Internal battery

Internal and rechargeable battery of SLA 6 V type (sealed lead acid) enables device operation without connecting the device to the mains (9h operation). The weighing instrument controls battery status and displays a respective pictogram on the screen.
Peak hold

Peak hold

Function registering the greatest temporary indication occurring in course of the weighing process. It is most often used in medical scales in order to hold the measurement indication.
GLP Procedures

GLP Procedures

Diagnostic function allowing to objectively document performed measurements. GLP procedures may be either presented in a short report form or extended one.
Animal weighing

Animal weighing

Process of mass determination for a product which may unwillingly reposition within the weighing pan. Mass determination in such cases requires much longer period of time when compared to typical weighing process. It is the user who defines period of time needed for control of measured product mass. The user can thus optimize the function depending on the measured product characteristics.
ALIBI Memory

ALIBI Memory

"ALIBI" memory enables saving and storing up to 100000 measurements.  Measurements are saved automatically upon each pressing of the key. There is no need for any additional operations or changing settings.
The following data related with the measurements is saved: measurement date; measurement time; result (mass); tare value; operator carrying out the measurement (logged in); product name.
The software saves the measurement in a so called loop, i.e. when the measurement no. 100001 is saved, the measurement 1 gets automatically deleted from the memory.
Measurements saved to balance memory cannot be deleted.
You can preview and print out the data saved to the ALIBI database.

Datos tecnicos

Numero máximo de divisiones legalizadas

6000 e

 

Clase OIML

III o IV

 

Pantalla

LCD (con retroiluminación)

 

Grado de protección

IP 43

 

Interface RS232

1× standard, 1× opción

 

Interface Wi-Fi®

1× standard

 

Alimentacion

100 ÷ 240 V AC 50 / 60 Hz

 

Modo de alimentación

adaptador de CA desmontable, akumulatory NiMH 6×AA

 

Corriente de alimentación adicional

12V DC + bateria

 

Horas de trabajo con baterias

max 7h

 

Numero máximo de divisiones de convertidor A/C

838 860 ×10

 

Crecimiento maximo de la señal

19,2 mV

 

Corriente mínima de 1 división legalizada

0,4 µV

 

Corriente maxima en una división legalizada

3,25 µV

 

Impedancia mínima de convertidor tensometrico

50 Ω

 

Impedancia máxima de convertidor tensométrico

1200 Ω

 

Corriente de alimentación en convertidor tensométrico

5V DC

 

Conexión de convertidores tensométricos

4 o 6 hilos + Blindaje de cable

 

Temperatura de trabajo

-10 ÷ +40

 °C

Temperatura de almacenamiento

-10 ÷ +50

 °C

Humedad relativa de aire

10% ÷ 80% RH sin condensación

 

Teclado

microswitch

 

Número de botones

5

 

Chasis

material ABS

 

Dimensiones de aparato

181×136×60

 mm

Dimensiones de embalaje

220×190×90

 mm

Masa neto

0,6

 kg

Masa bruto

1,2

 kg

Multirangos

1 o 2 rangos

 

Pantalla adicional

WD-4/1 (Opcional)

 

Documentación

Documentación técnica
Publicaciones y materiales didácticos
Manual de instrucciones
(0.58 MB)
Save See the publication
Manual de instrucciones
(0.29 MB)
Save See the publication
Data Sheet
(1.00 MB) EN
Save See the publication
Conformity Declaration
(0.04 MB) EN
Save See the publication
C315 Platform Scales
(2.13 MB) EN
Save See the publication

Programas

Drivers

LabVIEW (3.05 MB)

Software

R-Lab (149.39 MB)
Descargar la versión del software con un límite de 1.000 pesajes

Trabaja con

Plataforma de acero impermeable
Plataforma de acero pintada en polvo
Plataforma de acero pintada en polvo
Editor de Balanzas 2.0
RW Tool
R-LAB
RAD KEY
RADWAG Connect
RADWAG Development Studio
Controlador LabVIEW “Radwag Balances & Scales”
Impresoras de recibos
Cables RS 232 (Bascula a Impresora EPSON)
Cables RS 232, RS 485
Cables de corriente desde mechero de automóvil
Soportes, brazos
Convertidor RS232 a RS485
Convertidor RS232 a Ethernet
Salidas del bucle de corriente
Pantallas

RADWAG Balanzas Electrónicas

Torunska 5
26-600 Radom
Poland
tel.: +48 48 386 60 00
e-mail: export@radwag.com
TIN: PL7960000327
Vimeo Radwag YouTube Radwag Facebook Radwag
© 2019 RADWAG Balances and Scales. All rights reserved.

Watch more
RADWAG videos

movie
Radwag WEBINARS