Balanza de precisión PM 10.4Y en Balanzas de laboratorio - Radwag Balanzas Electrónicas

Balanza de precisión PM 10.4Y

Radwag Balances and Scales - Advanced Weighing Technologies
Selected language Español
Balanza de precisión PM 10.4Y en Balanzas de laboratorio
This image is for reference only.
Balanza de precisión PM 10.4Y
Código de producto: WL-223-0002
Select model (6)
done
Max: 10kgd: 0,01g

 200×185mm
expand_more
Max: 15kgd: 0,01g

 200×185mm
Max: 35kgd: 0,1g

 350×260mm
Max: 50kgd: 0,1g

 350×260mm
Max: 60kgd: 1g

 400×500mm
Max: 60kgd: 0,5g

 400×500mm
Descripción
Las balanzas de la serie PM están equipadas con un innovador sistema de medición basado en la tecnología RADWAG MonoBLOCK®. Esto permite un funcionamiento con una capacidad de... más ››
Maxima capacidad: 10kg
Legibilidad [d]: 0,01g

close
Select model:
Balanza de precisión PM 10.4Y
Balanza de precisión PM 15.4Y
Balanza de precisión PM 35.4Y
Balanza de precisión PM 50.4Y
Balanza de precisión PM 60.1.4Y
Balanza de precisión PM 60.05.4Y
Select all
ver
Guardar
Solicitar una oferta
Descripción
Las balanzas de la serie PM están equipadas con un innovador sistema de medición basado en la tecnología RADWAG MonoBLOCK®. Esto permite un funcionamiento con una capacidad de lectura de 0,01 g a una capacidad de 15 kg y una capacidad de lectura de 0,1 g a una capacidad de 50 kg.
El uso del nuevo sistema de medición, objeto de la patente RADWAG, garantiza la estabilidad de la repetibilidad en el tiempo a un intervalo sd <1d. La única solución del sistema de medición se caracteriza por su gran resistencia al cambio de las condiciones ambientales.
Un sistema de protección de 4 puntos incorporado evita la sobrecarga de balanza, lo que garantiza la seguridad en caso de carga demasiado pesada se aplica sobre el platillo de pesaje.

Principales características:
  • Nuevo sensor RADWAG MonoBLOCK®;
  • Repetibilidad sin igual de las indicaciones;
  • Pesaje de cargas pesadas con la máxima precisión;
  • Operación intuitiva garantizada por una pantalla táctil de color;
  • Cumplimiento con CFR21;
  • Mediciones de masa rápidas;
  • Diseño mecánico robusto - nueva plataforma de pesaje inferior;
  • Ergonomía mejorada - dos tipos de terminal de pesaje para la selección. 
La balanza ofrece la posibilidad de pesar cargas fuera de la plataforma de pesaje (llamado pesaje por debajo de la balanza). Esta es una alternativa para pesar cargas con dimensiones y formas no estándar o aquellas que generan campo magnético.
Stainless Steel in RADWAG products
Learn about the use and maintenance of stainless steel products:
Stainless Steel in RADWAG products. Standard and special applications
Datos tecnicos
Maxima capacidad

10

 kg

Minima cacacidad

0,5

 g

Precarga

1

 kg

Legibilidad [d]

0,01

 g

Rango de tara

-10

 kg

División de legalización [e]

0,1

 g

Pesada mínima usp

8,2

 g

Pesada mínima

0,82

 g

Repetibilidad (Max)

0,01

 g

Repetibilidad (5% Max)

0,004

 g

Linealidad

±0,03

 g

Tiempo de estabilización

3

 s

Calibración

interna (automatica)

 

Clase OIML

II

 

Sistema de nivelación

semiautomático - LevelSENSING

 

Pantalla

5,7” resistivo color touchscreen

 

Dimensión de platillo

200×185

 mm

Dimensiones de embalaje

520×520×280

 mm

Masa neto

10

 kg

Masa bruto

12,2

 kg

Grado de protección

IP 43

 

Conectividad

2×RS232, 2×USB-A, Ethernet, 4 IN / 4 OUT (digitales), Wi-Fi®

 

Alimentacion

100 — 240 V AC 50 / 60 Hz

 

Consumo máximo de potencia

0,5 A

 

Temperatura de trabajo

+10 — +40

 °C

La repetibilidad se expresa como una desviación estándar de 10 posiciones de carga.
El tiempo de estabilización depende de las condiciones externas y la dinámica de colocar los pesos en el platillo; especificado para el perfil FAST.
Características
Nivel electrónico

Nivel electrónico

Capacidades funcionale:
- funcion ALARMAS
- indicador de nivel gráfico
- tolerancias programables
Intercambio de datos
(puerto USB)

Intercambio de datos (puerto USB)

actualización de software
exportacion de base de datos de pesaje
exportación / importación de la base de datos
exportacion /importacion de ajustes de balanza
intercambio de los datos entre balanzas
Sensores
infrarrojo

Sensores infrarrojo

Capacidades funcionales:
- funcion PRINT
- funcion TARA
- ajuste de la sensibilidad de sensores
Vídeos
RADWAG Remote Desktop - Windows 10
RADWAG Remote Desktop
360°

Funciones
Autotest

Autotest

Diagnostic function aiming at metrological parameters determination (repeatability), the parameters are determined for the actual conditions of use. When speaking of repeatability it may be also used for weighing time optimization. Autotest is operated in an automatic mode thus operator’s time is saved.
Dosing

Dosing

Weighing process for which reference mass has been determined together with tolerance for its determination. Dosing tolerance is given in [%] and it is calculated in relation to the reference value thus being a permissible deviation of this process. This solution is used for weighing powders, liquids and loose materials. Dosing function performance is often supported with bargraph - load indicator. For industrial scales it is possible to use a control systems of dosing process.
Percent Weighing

Percent Weighing

Percent Weighing function is used for comparision of measured products with mass standard. Mass of a mass standard may be a numeric value taken from a database or it may be determined through a measurement process. Each measured product is compared to mass standard, mass of which is presumed as a model 100% ideal mass. For products weighing less than the mass standard, obtained results are lower than 100%, for products weighing more, the obtained results are greatly  exceeded.
Parts counting

Parts counting

Function using mass measurement for determination of  measured items quantity. Mass of a single item is required for this process. It may be either estimated through weighment or taken from a database. For items counting the following algorithm is used: all items mass / single item mass = quantity. Function operation is supperted by a mechanism of Automatic Correction of Accuracy. This allows to update single item mass in course of the process. To a certain extend Automatic Correction of Accuracy eliminates error which may be a result of different mass values of seemingly alike single elements. For industry solutions items counting may be simultaneously carried out with checkweighing and dosing thus industry solutions feature audio signalling base informing that specified number of items has been weighed. It is possible to apply weighing systems using few platfroms of different MAX capacities and different accuracies.
Formulation

Formulation

Function supporting the mixture making process, wherein the mixture contains various components. Formulation function usually uses the balance/scale database of components. Formulation serves for monitored checkweighing of every single component with a given tolerance. It is enriched with a set of individual settings.
Statistics

Statistics

Statistiscs function registers and analyses performed measurements. This supplies the user withthe following information: Max and Min standard deviation, average value, variance, range et.
Checkweighing

Checkweighing

Checkweighing function is used for checking whether the measured sample mass is within the predefined threshold values, Low [LO] and Hgh [HI]. The thresholds are given in [g] and [kg] units. Current state of a sample being measured is signalled by means of pictorgams located on a display for laboratory balances, for industrial scales Stackligt System is used. This visual +/- inspection is in operation during segregation, control or packing process of products for which mass has bees determined with a specifaied tolerance, eg. 12860 g 961
IR sensors

IR sensors

Programmable function supporting the weighing process through control of the following options: sliding weighing chamber doors, printout, zeroing, tarring etc. Especially appreciated wherever preventing the balance from soiling is important.
GLP Procedures

GLP Procedures

Diagnostic function allowing to objectively document performed measurements. GLP procedures may be either presented in a short report form or extended one.
Animal weighing

Animal weighing

Process of mass determination for a product which may unwillingly reposition within the weighing pan. Mass determination in such cases requires much longer period of time when compared to typical weighing process. It is the user who defines period of time needed for control of measured product mass. The user can thus optimize the function depending on the measured product characteristics.
Air density correction

Air density correction

Function performing correction of mass measurement indication, wherein the air density is taken into account. It is used in balances with reading unit < 0,01 mg.
Differential weighing

Differential weighing

Differential weighing informs about mass variation a particular sample, wherein the said variation is a result of manufacturing processes.

Differential weighing is often applied in product control process, for which reference product parameters have been specified in order to be used as a source of comparison for the whole series.
Insuchcasestandard deviation is the information which tells about quality and completeness of a final product. For systems based on a feed-back technique such information may be used by control units.
Ambient conditions monitoring

Ambient conditions monitoring

The possibility of cooperation with the THBR 2.0 system
Replaceable unit

Replaceable unit

Replaceable units.
Statistical Quality Control

Statistical Quality Control

Statistical control for determination of basic statistical criteria: maximum, minimum, standard deviation, mean values for each batch, etc.
Wi-Fi®

Wi-Fi®

Wi-Fi® offers possibility to send data from balance to a mobile iOS or Android device, via special data management apps. Wireless communication between the indicator and the weighing instrument enables operating the balance that is placed inside a laminar flow hood or a fume cupboard.
Documentación
Tarjetas de productos
Data Sheet

This product:

ver

Guardar

For the group:
ver Guardar
Manual de usuario
Manual de instrucciones - PM 4Y

ver

Guardar
(3.66 MB)
Manual de instrucciones - Radwag-Mass -Node-RED

ver

Guardar
(0.58 MB)
Start up Guide

ver

Guardar
(3.57 MB)
Declaraciones de conformidad
Conformity Declaration

ver

Guardar
(0.04 MB)
Publicaciones y folletos
Sistema THBR 2.0

ver

Guardar
(5.24 MB)
PM - Balanzas de Precision Para Altas Capacidades

ver

Guardar
(0.48 MB)
Stainless Steel in RADWAG products. Standard and special applications

ver

Guardar
(2.44 MB)
Perfiles Definidos

ver

Guardar
(1.65 MB)
Accesorios
Mesas antivibratil para balanzas de laboratorio
Audit Trail Reader
E2R System
Editor de Etiquetas R02
R.Barcode

Accesorios

R-LAB

Accesorios

RAD KEY

Accesorios

RADWAG Connect

Accesorios

RADWAG Development Studio
RADWAG Remote Desktop
Controlador LabVIEW “Radwag Balances & Scales”
Impresoras de recibos
Impresoras de etiquetas
Protecciones de seguridad
Concentradores USB

Accesorios

Convertidor RS 232 a USB
Salidas del bucle de corriente AP2-1
Cables RS 232 (Bascula a Impresora EPSON)

Accesorios

Cables RS 232, RS 485
Escáner de códigos de barra
Pantallas
Adaptadores de corriente
Módulos
Módulo de cumplimiento con 21 CFR parte 113
RADWAG Balanzas Electrónicas
Torunska 5
26-600 Radom
Poland
tel.: +48 48 386 60 00
e-mail: export@radwag.com
TIN: PL7960000327
Vimeo Radwag YouTube Radwag Facebook Radwag LinkedIn Radwag
© 2021 RADWAG Balances and Scales. All rights reserved.

Selecionar idioma

×
Change language AlbanianAlbanian
Change language DanishDanish
Change language NederlandseNederlandse
Change language EstonianEstonian
Change language FinnishFinnish
Change language HungarianHungarian
Change language IcelandicIcelandic
Change language KazakhKazakh
Change language LatvianLatvian
Change language LithuanianLithuanian
Change language MacedonianMacedonian
Change language NorwegianNorwegian
Change language PortuguesePortuguese
Change language RomanianRomanian
Change language RussianRussian
Change language SlovakSlovak
Change language SlovenianSlovenian
Change language SwedishSwedish
Change language UkrainianUkrainian
Change language SerbianSerbian
Change language MontenegrinMontenegrin
Change language page on Deutsch Deutsch
Change language page on English English
Change language page on Français Français
Change language page on Italiano Italiano
Change language page on Polski Polski
Change language page on Türkiye Türkiye
Česky
Change website to USA USA
Change language page on 中文 中文
Subscribe
Facebook
Youtube
Vimeo
LinkedIn
Webinars
close