Selected language English English
Change language
Change language page on Deutsch DeutschChange language page on Español EspañolChange language page on Français FrançaisChange language page on Italiano ItalianoChange language page on Polski PolskiChange language page on Türkiye Türkiye ČeskyChange website to USA USAChange language page on 中文 中文

WPT/P 60 Postal Scale for Packages

WPT/P 60 Postal Scale for Packages
This image is for reference only.

Product code: WP-106-0006
Request for quotation

Overview

Maximum capacity [Max]: 60kg
Readability [d]: 20g

Postal

scales

is designed for

weighing

parcels with possibility of multiple tarring in whole measuring range.

The device comprises

indicator

PUE C/31 series, which features a backlit LCD display, assembled on a pillar attached to the back side of the

weighing

platform. Additionally, the scale is equipped with a second display indicating the measuring result to a customer.
In non-verified version the scale can have additional functions: peak hold and measuring in Newton.

The

scales

is powered by mains or batteries, optionally, the scales can be equipped with RS 232 output.
Measuring

indicator

PUE C/31 series is standard equipment of this scale.

Functions

Plus/Minus Control

Plus/Minus Control

Control of sample's mass carried out with reference to specified MIN and MAX thresholds. The weight is considered to be correct if it is comprised within threshold values. A graphic visualisation of weighing result is displayed in a form of a bar graph.
Percent Weighing

Percent Weighing

Percent Weighing function is used for comparision of measured products with mass standard. Mass of a mass standard may be a numeric value taken from a database or it may be determined through a measurement process. Each measured product is compared to mass standard, mass of which is presumed as a model 100% ideal mass. For products weighing less than the mass standard, obtained results are lower than 100%, for products weighing more, the obtained results are greatly  exceeded.
Totalizing

Totalizing

Function adding new mass value to already obtained one. This allows to determine mass content of the mixture, being a composition of number of different consistence components. Totalizing is limited by maximum capacity parameter.
Parts counting

Parts counting

Function using mass measurement for determination of  measured items quantity. Mass of a single item is required for this process. It may be either estimated through weighment or taken from a database. For items counting the following algorithm is used: all items mass / single item mass = quantity. Function operation is supperted by a mechanism of Automatic Correction of Accuracy. This allows to update single item mass in course of the process. To a certain extend Automatic Correction of Accuracy eliminates error which may be a result of different mass values of seemingly alike single elements. For industry solutions items counting may be simultaneously carried out with checkweighing and dosing thus industry solutions feature audio signalling base informing that specified number of items has been weighed. It is possible to apply weighing systems using few platfroms of different MAX capacities and different accuracies.
Internal battery

Internal battery

Internal and rechargeable battery of SLA 6 V type (sealed lead acid) enables device operation without connecting the device to the mains (9h operation). The weighing instrument controls battery status and displays a respective pictogram on the screen.
Peak hold

Peak hold

Function registering the greatest temporary indication occurring in course of the weighing process. It is most often used in medical scales in order to hold the measurement indication.
Newton unit measurement

Newton unit measurement

Function allowing to perform the measurement in Newton unit, it may be used for processes aiming to determine force resulting in the sample damage.
Animal weighing

Animal weighing

Process of mass determination for a product which may unwillingly reposition within the weighing pan. Mass determination in such cases requires much longer period of time when compared to typical weighing process. It is the user who defines period of time needed for control of measured product mass. The user can thus optimize the function depending on the measured product characteristics.

Datasheet

Maximum capacity [Max]

60

 kg

Minimum load

100

 g

Readability [d]

20

 g

Tare range

-60

 kg

Display

LCD (backlit)

 

Communication interface

RS232

 

Power supply

100 ÷ 240 V AC 50 / 60 Hz and battery

 

Operation time on batteries

35 h (average time)

 

Operating temperature

0 ÷ +40

 °C

Atmospheric humidity

10% ÷ 85% RH no condensation

 

Weighing pan dimensions

400×500

 mm

Packaging dimensions

720×580×220

 mm

Net weight

15.5

 kg

Gross weight

17.8

 kg

Documentation

Technical specification
Publications and teaching materials

User Manual
(0.96 MB)

Save
See the publication

Data Sheet
(0.66 MB)

Save
See the publication

Conformity Declaration
(0.04 MB)

Save
See the publication

Measuring_instruments_in_industry
(0.05 MB)

Save
See the publication

Accessories

R-LAB
RAD-KEY
LabVIEW Driver
Receipt printer
RS 232 cables (scale - EPSON printer)
RS 232, RS 485 cables
Cigarette lighter receptacle power supply cables
RS232 1345 Converter
RS232 1339 Converter
Power loop output

Radwag Balances and Scales

Torunska 5
26-600 Radom
Poland
tel.: +48 48 386 63 03
e-mail: export@radwag.com
TIN: PL7960000327
Vimeo Radwag YouTube Radwag Facebook Radwag
© 2019 RADWAG Balances and Scales. All rights reserved.

See our movies
RADWAG

Radwag WEBINARS