Overview

Maximum capacity [Max]: 300kg
Readability [d]: 100g

Ramp bed scale is designed to weigh a patient who lies on a bed. The construction of the bed scale enables its application for various types of beds and it is not depend on installed braking systems. Long beams of the WPT/8B series ensure measurement of bed’s

mass

independently on location. Adjustable distance between the beams (up to 2,5 meters) is appropriate for different types of beds.
The WPT/8B scale features an

indicator

PUE C/31 series with backlit LCD display and 5-button keyboard. The scale is powered by mains and by accumulators 6 × AA installed inside indicator's housing.

The bed

scales

utilizes the most recent technologies on load cell design, providing:
  • light construction (single beam

    mass

    is approximately 8 kg);
  • ease of transportation;
  • easy running onto the beams (beam height: approximately 18mm).

Functions

Plus/Minus Control

Plus/Minus Control

Control of sample's mass carried out with reference to specified MIN and MAX thresholds. The weight is considered to be correct if it is comprised within threshold values. A graphic visualisation of weighing result is displayed in a form of a bar graph.
Percent Weighing

Percent Weighing

Percent Weighing function is used for comparision of measured products with mass standard. Mass of a mass standard may be a numeric value taken from a database or it may be determined through a measurement process. Each measured product is compared to mass standard, mass of which is presumed as a model 100% ideal mass. For products weighing less than the mass standard, obtained results are lower than 100%, for products weighing more, the obtained results are greatly  exceeded.
Totalizing

Totalizing

Function adding new mass value to already obtained one. This allows to determine mass content of the mixture, being a composition of number of different consistence components. Totalizing is limited by maximum capacity parameter.
Parts counting

Parts counting

Function using mass measurement for determination of  measured items quantity. Mass of a single item is required for this process. It may be either estimated through weighment or taken from a database. For items counting the following algorithm is used: all items mass / single item mass = quantity. Function operation is supperted by a mechanism of Automatic Correction of Accuracy. This allows to update single item mass in course of the process. To a certain extend Automatic Correction of Accuracy eliminates error which may be a result of different mass values of seemingly alike single elements. For industry solutions items counting may be simultaneously carried out with checkweighing and dosing thus industry solutions feature audio signalling base informing that specified number of items has been weighed. It is possible to apply weighing systems using few platfroms of different MAX capacities and different accuracies.
Internal battery

Internal battery

Internal and rechargeable battery of SLA 6 V type (sealed lead acid) enables device operation without connecting the device to the mains (9h operation). The weighing instrument controls battery status and displays a respective pictogram on the screen.
Peak hold

Peak hold

Function registering the greatest temporary indication occurring in course of the weighing process. It is most often used in medical scales in order to hold the measurement indication.
Animal weighing

Animal weighing

Process of mass determination for a product which may unwillingly reposition within the weighing pan. Mass determination in such cases requires much longer period of time when compared to typical weighing process. It is the user who defines period of time needed for control of measured product mass. The user can thus optimize the function depending on the measured product characteristics.

Datasheet

Maximum capacity [Max]

300

 kg

Readability [d]

100

 g

Tare range

-300

 kg

Display

LCD (backlit)

 

Communication interface

RS232

 

Power supply

100 ÷ 240 V AC 50 / 60 Hz and battery

 

Operation time on batteries

35 h (average time)

 

Operating temperature

0 ÷ +40

 °C

Relative humidity

10% ÷ 85% RH no condensation

 

Documentation

Technical specification
Publications and teaching materials
User Manual
(1.20 MB)
Save See the publication
Data Sheet
(0.75 MB)
Save See the publication
Conformity Declaration
(0.04 MB)
Save See the publication

Accessories

R-LAB
RAD-KEY
LabVIEW Driver
Receipt printer
RS 232 cables (scale - EPSON printer)
RS 232, RS 485 cables
Cigarette lighter receptacle power supply cables
Displays
RS232 1345 Converter
RS232 1339 Converter
Power loop output

Radwag Balances and Scales

Torunska 5
26-600 Radom
Poland
tel.: +48 48 386 60 00
e-mail: export@radwag.com
TIN: PL7960000327
Vimeo Radwag YouTube Radwag Facebook Radwag LinkedIn Radwag
© 2019 RADWAG Balances and Scales. All rights reserved.

Watch more
RADWAG videos


movie
Radwag WEBINARS