SDKP Workstation for Pipettes Calibration

Radwag – Laboratory and Industrial Weighing Solutions
Selected language English
SDKP Workstation for Pipettes Calibration
This image is for reference only.

SDKP Workstation for Pipettes Calibration

Product code: WL-101-0181
close
Change the model:
SDKP Workstation for Pipettes Calibration
SDKP DUAL Workstation for Pipettes Calibration
Select all
Show me
Download
Overview

SDKP Workstation for Pipettes Calibration

 
 
In order to ensure measurement traceability, meet all the requirements resulting from supervision over measuring equipment and to facilitate  the process of pipettes calibration RADWAG recommends effective and ergonomic solution for calibrating automatic pipettes conducted by a user - complete workstation for pipettes calibration.

Application:
Calibration of automatic pipettes:
  • with fixed volume
  • with adjustable volume.
Unit contents:
  • table for calibration
  • anti-vibration table
  • probe for temperature, humidity and pressure measurement
  • probe for water temperature measurement
  • sink for used water
  • armrests
  • LCD monitor
  • PC with pre-installed software PIPETTES RADWAG
  • power supply
  • keyboard and mouse
  • container for used water

Adapters for pipettes calibration

Pipette calibration adapters are intended for calibration and verification of piston pipettes using gravimetric method. Use of the pipette calibration adapter reduces maximum capacity of the balance by the mass of the weighing vessel. The table presents the minimum reguirements in accordance with ISO 8655 standard. It also enables to select suitable adapter for pipette calibration and respective balance version.
Selected volume1 of apparatus under test
V
Resolution
mg
Repeatability and linearity
mg
Recommended balance
1 µl ≤ V ≤ 10 µl 0.001 0.002 MYA 21.4Y PLUS
MYA 21.4Y
XA 6/21.4Y.M.A PLUS
XA 6/21.4Y.M.A
XA 6/21.4Y.M
 
10 µl < V ≤ 100 µl 0.01 0.02 XA 82/220.4Y.A PLUS
XA 82/220.4Y.A
XA 82/220.4Y
XA 120/250.4Y.A PLUS
XA 120/250.4Y.A
XA 120/250.4Y
100 µl < V ≤ 1000 µl 0.1 0.2
1 ml < V ≤ 10 ml 0.1 0.2
Adapter for pipette calibration MY 11 XA 11 XA 17 XA 100 XA 17 XA 100
Maximum vessel capacity 11 ml 11 ml 17 ml 100 ml 17 ml 100 ml
Weighing vessel mass ~10 g ~10 g ~11 g ~65 g ~11 g ~65 g

1 For practical purposes, the nominal volume may be used to choose the balance. [Reference: ISO8655-6:2002, pg. 2]
If the standard uncertainty of measurement of the balance is known (e.g. from the balance calibration certificate), it may be used instead of the repeatability and linearity. The standard uncertainty of measurement shall not be more than two to three times the resolution. [Reference: ISO8655-6:2002, pg. 2]
 
 
Datasheet
Delivery components

table for calibration,
anti-vibration table,
probe for temperature,
humidity and pressure measurement,
probe for water temperature measurement,
sink for used water,
armrests,
LCD monitor,
PC with pre-installed software PIPETTES RADWAG,
power supply,
keyboard and mouse,
container for used water

 

Packaging dimensions

820×1160×890

 mm

Length

1100

 mm

Width

750

 mm

Height

1100

 mm

Number of workstations

1

 

Documentation
Datasheet
Data Sheet Data Sheet
Data Sheet

Show me
Show me
Download
Download

Choose more product:
Show me Show me DownloadDownload
User Manuals
User Manual - PSW
User Manual - PSW
Show me
Show me
Download
Download
(1.73 MB)
Publications and Brochures
Pipettes Calibration Workstation
Pipettes Calibration Workstation
Show me
Show me
Download
Download
(1.36 MB)
Pipettes
Pipettes
Show me
Show me
Download
Download
(2.47 MB)
Tables and weighing workstations
Tables and weighing workstations
Show me
Show me
Download
Download
(1.28 MB)
Checking and calibrating fixed volume and adjustable volume piston pipettes using a gravimetric method
Checking and calibrating fixed volume and adjustable volume piston pipettes using a gravimetric method
Show me
Show me
Download
Download
(5.49 MB)
Weighing systems for calibration  and verification of piston pipettes
Weighing systems for calibration and verification of piston pipettes
Show me
Show me
Download
Download
(5.27 MB)
Compatible with
Radwag Balances and Scales
Torunska 5
26-600 Radom
Poland
tel.: +48 48 386 60 00
e-mail: export@radwag.com
TIN: PL7960000327
Vimeo Radwag YouTube Radwag Facebook Radwag LinkedIn Radwag
© 2024 RADWAG Balances and Scales. All rights reserved.

Select language

×
Change language AlbanianAlbanian
Change language DanishDanish
Change language NederlandseNederlandse
Change language EstonianEstonian
Change language FinnishFinnish
Change language HungarianHungarian
Change language IcelandicIcelandic
Change language KazakhKazakh
Change language LatvianLatvian
Change language LithuanianLithuanian
Change language MacedonianMacedonian
Change language NorwegianNorwegian
Change language PortuguesePortuguese
Change language RomanianRomanian
Change language RussianRussian
Change language SlovakSlovak
Change language SlovenianSlovenian
Change language SwedishSwedish
Change language UkrainianUkrainian
Change language SerbianSerbian
Change language MontenegrinMontenegrin
Change language page on Deutsch Deutsch
Change language page on Español Español
Change language page on Français Français
Change language page on Italiano Italiano
Change language page on Polski Polski
Change language page on Türkiye Türkiye
Česky
Change website to USA USA
Change language page on 中文 中文
Subscribe Subscribe Subscribe
Radwag in Facebook Radwag in Facebook Facebook
Radwag in YouTube Radwag in YouTube Youtube
Radwag in Vimeo Radwag in Vimeo Vimeo
Radwag in LinkedIn Radwag in LinkedIn LinkedIn
Webinars Radwag Webinars Radwag Webinars
close
E-mail:
Company name:
Name:
I consent to the processing of my personal data for marketing purposes by Radwag Wagi Elektroniczne Witold Lewandowski.
I consent to receive marketing and product-related messages by electronic means from Radwag Wagi Elektroniczne Witold Lewandowski.
I have read the Privacy Policy of RADWAG Wagi Elektroniczne Witold Lewandowski.
lock_openI want to access the files
close
Slide to go back ↩