PS 450.3Y Precision Balance

PS 450.3Y Precision Balance view:1

Product code: WL-220-0030
Information about conformity of a product with European Union regulations that concern the product. Marking the product with CE sign makes the manufacturer responsible for the product to meet requirements of general safety regulations determined by CE marking directives.
CE
Information about conformity of a product with European Union regulations that concern the product. Marking the product with CE sign makes the manufacturer responsible for the product to meet requirements of general safety regulations determined by CE marking directives.
The procedure within the scope of Legal Metrology. It is performed by regional Offices of Measures or authorized entities before the new product is introduced to the market.  The procedure is performed on the basis of tests validating conformity of a product with the directives. For most measuring devices, including balances and scales, this procedure has been replaced with declaration of conformity.
CE
Information about conformity of a product with European Union regulations that concern the product. Marking the product with CE sign makes the manufacturer responsible for the product to meet requirements of general safety regulations determined by CE marking directives.
Verification
The procedure within the scope of Legal Metrology. It is performed by regional Offices of Measures or authorized entities before the new product is introduced to the market. The procedure is performed on the basis of tests validating conformity of a product with the directives. For most measuring devices, including balances and scales, this procedure has been replaced with declaration of conformity.
CE
Information about conformity of a product with European Union regulations that concern the product. Marking the product with CE sign makes the manufacturer responsible for the product to meet requirements of general safety regulations determined by CE marking directives.
Verification
The procedure within the scope of Legal Metrology. It is performed by regional Offices of Measures or authorized entities before the new product is introduced to the market. The procedure is performed on the basis of tests validating conformity of a product with the directives. For most measuring devices, including balances and scales, this procedure has been replaced with declaration of conformity.
2 years warranty
Request for quotation

Overview

Maximum capacity [Max]: 450g

Readability [d]: 1mg


Precision balance PS 3Y series features a 5,7” TFT colourful touch screen display providing new approach to balance operation and presentation of measurement result. The balance enables highly developed customization of its settings through user profiles.

The 3Y series comprises automatic internal adjustment system using an internal mass standard. The balance level is monitored by a LevelSENSING system, a RADWAG patented solution including an electronic level. A new feature of the 3Y series is on-line monitoring of ambient conditions by means of either internal sensors or external ambient conditions module THB.

A newly implemented differential weighing mode enables controlling mass of a tested load subjected to different processes over time.

Extended databases of the 3Y series balance allow to keep records of all acquired measurements, additionally they make data print and export possible. Standard printouts or user defined, fully editable templates allow for creating documentation required by GLP/GMP practically in any organization. 
The 3Y series features an independent mass control mode organized in cooperation with an automatic feeder PA-04/H series.

Balance protective cover offered in standard.

Media

Features

Electronic
level indicator
Functions:
- ALARM function
- graphic level indicator
- programmable acceptable tilts

Electronic
level indicator

Functions:
- ALARM function
- graphic level indicator
- programmable acceptable tilts
Data exchange through
USB storage devices
- update balance software
- export weighing data
- export/import databases
- export/import balance settings
- exchange data between balances

Data exchange through
USB storage devices

- update balance software
- export weighing data
- export/import databases
- export/import balance settings
- exchange data between balances
Infrared
proximity sensors
Optional functions:
- PRINT function
- TARE function
- sensor's sensitivity adjustment

Infrared
proximity sensors

Optional functions:
- PRINT function
- TARE function
- sensor's sensitivity adjustment
Portability
Extra option:
Balances with
a wireless terminal

Portability

Application:

Elimination of extra sources of vibration
Using wireless terminal facilitates elimination of additional vibrations resulting from daily operation on a balance. Owing to that, balances with highest resolutions might be used without the need of dedicated weighing workstations.

Convenience and comfort of weighing in fume cupboards and laminar flow cabins
Wireless communication between a terminal and a weighing module makes balance operation more comfortable and safer.

Balance isolation form influence of environmental conditions
Wireless communication allows to either place the weighing module inside a draft shield or to isolate it from the operator. This allows to weight toxic substances without putting operator's health or life at risk.
Interfaces
- Ethernet
- 2×USB
- 2×RS 232
- 4 in / 4 out
- WiFi 2,4GHz b,g,n

Interfaces

- Ethernet
- 2×USB
- 2×RS 232
- 4 in / 4 out
- WiFi 2,4GHz b,g,n

Functions

Autotest

Autotest

Radwag Autotest
Diagnostic function aiming at metrological parameters determination (repeatability), the parameters are determined for the actual conditions of use. When speaking of repeatability it may be also used for weighing time optimization. Autotest is operated in an automatic mode thus operator’s time is saved.
Dosing

Dosing

Radwag Dosing
Weighing process for which reference mass has been determined together with tolerance for its determination. Dosing tolerance is given in [%] and it is calculated in relation to the reference value thus being a permissible deviation of this process. This solution is used for weighing powders, liquids and loose materials. Dosing function performance is often supported with bargraph - load indicator. For industrial scales it is possible to use a control systems of dosing process.
Percent Weighing

Percent Weighing

Radwag Percent Weighing
Percent Weighing function is used for comparision of measured products with mass standard. Mass of a mass standard may be a numeric value taken from a database or it may be determined through a measurement process. Each measured product is compared to mass standard, mass of which is presumed as a model 100% ideal mass. For products weighing less than the mass standard, obtained results are lower than 100%, for products weighing more, the obtained results are greatly  exceeded.
Parts counting

Parts counting

Radwag Parts counting
Function using mass measurement for determination of  measured items quantity. Mass of a single item is required for this process. It may be either estimated through weighment or taken from a database. For items counting the following algorithm is used: all items mass / single item mass = quantity. Function operation is supperted by a mechanism of Automatic Correction of Accuracy. This allows to update single item mass in course of the process. To a certain extend Automatic Correction of Accuracy eliminates error which may be a result of different mass values of seemingly alike single elements. For industry solutions items counting may be simultaneously carried out with checkweighing and dosing thus industry solutions feature audio signalling base informing that specified number of items has been weighed. It is possible to apply weighing systems using few platfroms of different MAX capacities and different accuracies.
Formulation

Formulation

Radwag Formulation
Function supporting the mixture making process, wherein the mixture contains various components. Formulation function usually uses the balance/scale database of components. Formulation serves for monitored checkweighing of every single component with a given tolerance. It is enriched with a set of individual settings.
Newton unit measurement

Newton unit measurement

Radwag Newton unit measurement
Function allowing to perform the measurement in Newton unit, it may be used for processes aiming to determine force resulting in the sample damage.
Statistics

Statistics

Radwag Statistics
Statistiscs function registers and analyses performed measurements. This supplies the user withthe following information: Max and Min standard deviation, average value, variance, range et.
Checkweighing

Checkweighing

Radwag Checkweighing
Checkweighing function is used for checking whether the measured sample mass is within the predefined threshold values, Low [LO] and Hgh [HI]. The thresholds are given in [g] and [kg] units. Current state of a sample being measured is signalled by means of pictorgams located on a display for laboratory balances, for industrial scales Stackligt System is used. This visual +/- inspection is in operation during segregation, control or packing process of products for which mass has bees determined with a specifaied tolerance, eg. 12860 g 961
IR sensors

IR sensors

Radwag IR sensors
Programmable function supporting the weighing process through control of the following options: sliding weighing chamber doors, printout, zeroing, tarring etc. Especially appreciated wherever preventing the balance from soiling is important.
Under-pan weighing

Under-pan weighing

Radwag Under-pan weighing
GLP Procedures

GLP Procedures

Radwag GLP Procedures
Diagnostic function allowing to objectively document performed measurements. GLP procedures may be either presented in a short report form or extended one.
Animal weighing

Animal weighing

Radwag Animal weighing
Process of mass determination for a product which may unwillingly reposition within the weighing pan. Mass determination in such cases requires much longer period of time when compared to typical weighing process. It is the user who defines period of time needed for control of measured product mass. The user can thus optimize the function depending on the measured product characteristics.
Density determination

Density determination

Radwag Density determination
Liquid or solid body density function uses the Archimedes principle and it requires a special kit to be applied. The kit when used, replaces a weighing pan. For solids mass of the sample must be determined first in the air, next in the liquid of specified density. For liquids the so called sinker, density of which has been determined, must be measured first in the air, next in the tested liquid. The density determination process is disturbed by air bubbles which may stick either to the measured sample or the sinker. In case of laboratory equipment very light solids may be measured. For industry, solid bodies density may be determined by means of  under-pan weighing. Tested load of significant size may be measured this way.
Differential weighing

Differential weighing

Radwag Differential weighing
Differential weighing informs about mass variation a particular sample, wherein the said variation is a result of manufacturing processes.<br />
Differential weighing is often applied in product control process, for which reference product parameters have been specified in order to be used as a source of comparison for the whole series.
Insuchcasestandard deviation is the information which tells about quality and completeness of a final product. For systems based on a feed-back technique such information may be used by control units.
Statistical Quality Control

Statistical Quality Control

Radwag Statistical Quality Control

Datasheet

Maximum capacity [Max] 450 g
Minimum load 20 mg
Readability [d] 1 mg
Weighing pan dimensions 128×128 mm
Tare range -450 g
Repeatability 0,001 g
Linearity ±0,002 g
Minimum weight (USP) 1 g
Minimum weight (U=1%,k=2) 0,1 g
Stabilization time 2 s
Sensitivity drift 2ppm/°C in temperature +15 ÷ +35 °C
Operating temperature +10 ÷ +40 °C
Power supply 13,5 ÷ 16 V DC 
Display 5,7'' (panel touchscreen) 
Communication interface 2×USB, 2×RS 232, Ethernet, 4Inputs/4Outputs (digital), Wireless Connection 
Packaging dimensions 716×360×260 mm
Adjustment internal (automatic) 
Net weight 5,4 kg
Gross weight 7,9 kg
Power consumption 500mA (wireless terminal - 1A) 

Documentation

Technical Documentation

User Manual
4.17 MB EN

see the publication

Data Sheet PS 3Y
1.32 MB EN

see the publication

Conformity Declaration
0.03 MB EN

see the publication

ISO 9001:2015 Certificate
0.63 MB EN

see the publication

Certificate of Health Quality
0.43 MB EN

see the publication
Publications and teaching materials

Accessories

Granite Antivibration tables
Antivibration tables for laboratory balances
Professional weighing table
R-LAB
E2R SYSTEM
Label Editor R02
Audit Trail Reader
RAD-KEY
3Y Database Editor
R.Barcode
Parameter Editor
RADWAG Development Studio
LabVIEW Driver
RADWAG Connect
RADWAG Remote Desktop
Under-hook weighing rack
Density determination kit
Receipt printer
Label Printers
Ambient Conditions Monitoring
Cigarette lighter receptacle power supply cables
RS 232 cables (scale - computer)
RS 232 cables (scale - EPSON printer)
Automatic feeders
Barcode scanners

Accessories

Product name

Overview

DS2208 Barcode Scanner

DS2208 Barcode Scanner

DS2208 barcode scanner, as a new generation of LS2208 series, is a response to the tills and retail outlets need to read barcodes directly from mobile phones' s ...

LS2208 Barcode Scanner

LS2208 Barcode Scanner

Barcode scanner model Symbol LS2208 is a manual device designed for operation in adverse industrial conditions. Symbol LS2208 is ready to cooperate with ...

PD9330 Barcode Scanner

PD9330 Barcode Scanner

The Datalogic product range is now extended by series of PowerScan™ 9300 laser scanners. The device combines excellent functionality of PowerScan series with ne ...

PD9530 Barcode Scanner

PD9530 Barcode Scanner

Datalogic PowerScan PD9530 is a quick and reliable scanner intended for area imager barcodes. The scanner ensures omnidirectional readout of barcodes, even from ...

PM9300 Barcode Scanner

PM9300 Barcode Scanner

PowerScan™ PM9300 is a wireless version of PD9300 scanner. There are three types of the device: PM9300 – wireless model, PM9300-D – intermediate model with d ...

PM9500 Barcode Scanner

PM9500 Barcode Scanner

PM 9500 is a robust barcode scanner intended for industry. The scanner is equipped with 'Datalogic STAR Cordless' system which ensures excellent quality of wire ...

PM9300-D Barcode Scanner

PM9300-D Barcode Scanner

PowerScan™ PM9300 is a wireless version of PD9300 scanner. There are three types of the device: PM9300 – wireless model, PM9300-D – intermediate model with d ...

PD9330-AR Barcode Scanner

PD9330-AR Barcode Scanner

The Datalogic product range is now extended by series of PowerScan™ 9300 laser scanners. The device combines excellent functionality of PowerScan series with ne ...

PM9300-DK Barcode Scanner

PM9300-DK Barcode Scanner

PowerScan™ PM9300 is a wireless version of PD9300 scanner. There are three types of the device: PM9300 – wireless model, PM9300-D – intermediate model with d ...

Anti-draft Chamber for balances with a weighing pan 128x128mm
Balance Storage Case
Displays
Power Adapters
Radwag Balances and Scales
Torunska 5
26-600 Radom
Poland
tel.: +48 48 386 63 03
e-mail: export@radwag.com
TIN: PL7960000327
Vimeo Radwag YouTube Radwag Facebook Radwag Google Plus Radwag
® 2018 RADWAG Balances and Scales. All rights reserved.

See our movies
RADWAG