Max: 21gd: 1µg

 ø26mm
expand_more
Max: 0,8 / 3gd: 1 / 10µg

 ø16 + ø60 (for filters)mm
Max: 2,1gd: 1µg

 ø16mm
Max: 5,1gd: 1µg

 ø26mm
Max: 6,1gd: 1µg

 ø26mm
Max: 11 / 52gd: 1 / 10µg

 ø26 / ø40mm
Max: 11gd: 1µg

 ø26mm
Max: 21 / 52gd: 1 / 10µg

 ø26 / ø40mm
Max: 31gd: 1µg

 ø26mm
Overview
Faster measurement with the new CPU 4Y balances feature Dual Core 2 x 1 GB processor which delivers noticeable performance improvements including faster operation and shorter stabilization time... More ››
Maximum capacity [Max]: 21g
Readability [d]: 1µg

close
Select model:
MYA 0,8/3.4Y Microbalance
MYA 2.4Y Microbalance
MYA 5.4Y Microbalance
MYA 6.4Y Microbalance
MYA 11/52.4Y Microbalance
MYA 11.4Y Microbalance
MYA 21/52.4Y Microbalance
MYA 21.4Y Microbalance
MYA 31.4Y Microbalance
Select all
View
Download
Request a Quote
Overview
Faster measurement with the new CPU
4Y balances feature Dual Core 2 x 1 GB processor which delivers noticeable performance improvements including faster operation and shorter stabilization time retaining high repeatability values.

16 GB RAM – more data management possibilities
16 GB RAM offers possibility of recording data in a form of complex reports. Time and statistic data diagrams on series of weighments are another useful option.

The best possible repeatability and USP regulations conformity
The best weighing accuracy and repeatability – with sd ≤ 1d combined with USP regulations conformity (Section 41 and 1251) make 4Y balances a new standard for mass measurement quality.

Ergonomics and safety
Wireless communication between balance terminal and a weighing unit make it possible to comfortably operate 4Y series balances in laminar air flow cabinets and fume cupboards.

Remote control operation
Wireless Connection module offers wireless transfer of data recorded by 4Y balance to any portable device powered by iOS or Android systems using special applications intended for data management.

Data safety
Every single 4Y balance features ALIBI memory designed to provide protection and automatic recording of your measurements. Options such as data preview, copying and archiving are also
available to users.

Filter weighing option
This innovative solution enables the user to easily swap the weighing chamber with the chamber for filter weighing, which considerably expands the MYA 4Y microbalance functionality. The filter weighing chamber is characterized by high ingress protection. Large open-work weighing pan allows precise weighing of filters of various dimensions (max ø100). It is made of stainless steel which makes the chamber resistant to chemicals, colour change and scratches. The additional chamber does not come standard with the MYA 4Y microbalance.
CAUTION:
In order to carry out the weighing process by means of microbalance and ultra-microbalances correctly, it is necessary to prepare the workstation and to operate the device as required.
Usage and installation guidelines are to found in the following document: Installation and usage conditions for ultra-microbalances and microbalances.
Stainless Steel in RADWAG products
Learn about the use and maintenance of stainless steel products:
Stainless Steel in RADWAG products. Standard and special applications
Datasheet
Maximum capacity [Max]

21

 g

Minimum load

100

 µg

Readability [d]

1

 µg

Tare range

-21

 g

Verification scale interval [e]

1

 mg

Standard repeatability [5% Max]

1

 µg

Standard repeatability [Max]

3

 µg

Permissible repeatability [5% Max]

1.6

 µg

Permissible repeatability [Max]

4

 µg

Linearity

±7

 µg

Eccentric load deviation

7

 µg

Stabilization time

max 10

 s

Adjustment

internal (automatic)

 

OIML Class

I

 

Standard minimum weight (USP)

2

 mg

Standard minimum weight (U=1%, k=2)

0.2

 mg

Protection class

IP 43

 

Levelling system

semi-automatic - LevelSENSING

 

Display

5.7” resistive colour touchscreen

 

Weighing chamber dimensions

ø90×90

 mm

Weighing pan dimensions

ø26

 mm

Packaging dimensions

660×660×455

 mm

Net weight

9.1

 kg

Gross weight

16.6

 kg

Communication interface

2×RS232, 2×USB-A, Ethernet, 4 IN / 4 OUT (digital), Wi-Fi®

 

Power supply

100 — 240 V AC 50 / 60 Hz

 

Power consumption max.

10 W

 

Operating temperature

+10 — +40

 °C

Operating temperature change rate

±0.3°C/1h (±1°C/8h)

 

Relative humidity

40% — 80%

 

Relative humidity change rate

±1%/h (±4%/8h)

 

Repeatability is expressed as a standard deviation from 10 cycles of mass standard weighing.
Stabilization time depends on the ambient conditions and the dynamics of weighing pan loading; specified for FAST profile.
Features
Electronic
level indicator

Electronic
level indicator

Functions:
  • ALARM function
  • graphic level indicator
  • programmable acceptable tilts
Data exchange through
USB storage devices

Data exchange through
USB storage devices

  • update balance software
  • export weighing data
  • export/import databases
  • export/import balance settings
  • exchange data between balances
Infrared
proximity sensors

Infrared
proximity sensors

Optional functions:
  • PRINT function
  • TARE function
  • sensor's sensitivity adjustment
Portability

Portability

Application:

Elimination of extra sources of vibration
Using wireless terminal facilitates elimination of additional vibrations resulting from daily operation on a balance. Owing to that, balances with highest resolutions might be used without the need of dedicated weighing workstations.

Convenience and comfort of weighing in fume cupboards and laminar flow cabins
Wireless communication between a terminal and a weighing module makes balance operation more comfortable and safer.

Balance isolation form influence of environmental conditions
Wireless communication allows to either place the weighing module inside a draft shield or to isolate it from the operator. This allows to weight toxic substances without putting operator's health or life at risk.
Interfaces

Interfaces

  • Ethernet
  • 2×USB
  • 2×RS 232
  • 4 in / 4 out
  • WiFi 2,4GHz b,g,n
Videos
New weighing chamber for MYA.4Y and UYA.4Y microbalances
4y series - Ultra-microbalances and microbalances
RADWAG Remote Desktop - Windows 10
RADWAG Remote Desktop
4Y Balances: Video-Guidance and an on-screen manuals
4Y Series RADWAG Balances
Functions
Autotest

Autotest

Diagnostic function aiming at metrological parameters determination (repeatability), the parameters are determined for the actual conditions of use. When speaking of repeatability it may be also used for weighing time optimization. Autotest is operated in an automatic mode thus operator’s time is saved.
Dosing

Dosing

Weighing process for which reference mass has been determined together with tolerance for its determination. Dosing tolerance is given in [%] and it is calculated in relation to the reference value thus being a permissible deviation of this process. This solution is used for weighing powders, liquids and loose materials. Dosing function performance is often supported with bargraph - load indicator. For industrial scales it is possible to use a control systems of dosing process.
Percent Weighing

Percent Weighing

Percent Weighing function is used for comparision of measured products with mass standard. Mass of a mass standard may be a numeric value taken from a database or it may be determined through a measurement process. Each measured product is compared to mass standard, mass of which is presumed as a model 100% ideal mass. For products weighing less than the mass standard, obtained results are lower than 100%, for products weighing more, the obtained results are greatly  exceeded.
Parts counting

Parts counting

Function using mass measurement for determination of  measured items quantity. Mass of a single item is required for this process. It may be either estimated through weighment or taken from a database. For items counting the following algorithm is used: all items mass / single item mass = quantity. Function operation is supperted by a mechanism of Automatic Correction of Accuracy. This allows to update single item mass in course of the process. To a certain extend Automatic Correction of Accuracy eliminates error which may be a result of different mass values of seemingly alike single elements. For industry solutions items counting may be simultaneously carried out with checkweighing and dosing thus industry solutions feature audio signalling base informing that specified number of items has been weighed. It is possible to apply weighing systems using few platfroms of different MAX capacities and different accuracies.
Formulation

Formulation

Function supporting the mixture making process, wherein the mixture contains various components. Formulation function usually uses the balance/scale database of components. Formulation serves for monitored checkweighing of every single component with a given tolerance. It is enriched with a set of individual settings.
Statistics

Statistics

Statistiscs function registers and analyses performed measurements. This supplies the user withthe following information: Max and Min standard deviation, average value, variance, range et.
Checkweighing

Checkweighing

Checkweighing function is used for checking whether the measured sample mass is within the predefined threshold values, Low [LO] and Hgh [HI]. The thresholds are given in [g] and [kg] units. Current state of a sample being measured is signalled by means of pictorgams located on a display for laboratory balances, for industrial scales Stackligt System is used. This visual +/- inspection is in operation during segregation, control or packing process of products for which mass has bees determined with a specifaied tolerance, eg. 12860 g 961
IR sensors

IR sensors

Programmable function supporting the weighing process through control of the following options: sliding weighing chamber doors, printout, zeroing, tarring etc. Especially appreciated wherever preventing the balance from soiling is important.
GLP Procedures

GLP Procedures

Diagnostic function allowing to objectively document performed measurements. GLP procedures may be either presented in a short report form or extended one.
Animal weighing

Animal weighing

Process of mass determination for a product which may unwillingly reposition within the weighing pan. Mass determination in such cases requires much longer period of time when compared to typical weighing process. It is the user who defines period of time needed for control of measured product mass. The user can thus optimize the function depending on the measured product characteristics.
Pipettes Calibration

Pipettes Calibration

Function verifying correctness of piston pipettes functioning, the verification is performed via gravimetric measurement of the excreted liquid. Pipettes calibration may be either a stand-alone module or it may be operated
Air density correction

Air density correction

Function performing correction of mass measurement indication, wherein the air density is taken into account. It is used in balances with reading unit < 0,01 mg.
Automatic sliding door

Automatic sliding door

Automatic side panes opened via touch-free IR sensors.
Differential weighing

Differential weighing

Differential weighing informs about mass variation a particular sample, wherein the said variation is a result of manufacturing processes.

Differential weighing is often applied in product control process, for which reference product parameters have been specified in order to be used as a source of comparison for the whole series.
Insuchcasestandard deviation is the information which tells about quality and completeness of a final product. For systems based on a feed-back technique such information may be used by control units.
Ambient conditions monitoring

Ambient conditions monitoring

The possibility of cooperation with the THBR 2.0 system
Replaceable unit

Replaceable unit

Replaceable units.
Statistical Quality Control

Statistical Quality Control

Statistical control for determination of basic statistical criteria: maximum, minimum, standard deviation, mean values for each batch, etc.
ALIBI Memory

ALIBI Memory

"ALIBI" memory enables saving and storing up to 100000 measurements.  Measurements are saved automatically upon each pressing of the key. There is no need for any additional operations or changing settings.
The following data related with the measurements is saved: measurement date; measurement time; result (mass); tare value; operator carrying out the measurement (logged in); product name.
The software saves the measurement in a so called loop, i.e. when the measurement no. 100001 is saved, the measurement 1 gets automatically deleted from the memory.
Measurements saved to balance memory cannot be deleted.
You can preview and print out the data saved to the ALIBI database.
Wi-Fi®

Wi-Fi®

Wi-Fi® offers possibility to send data from balance to a mobile iOS or Android device, via special data management apps. Wireless communication between the indicator and the weighing instrument enables operating the balance that is placed inside a laminar flow hood or a fume cupboard.
Documentation
Datasheet
Data Sheet

This product:

View

Download

For the group:
View Download
User Manuals
User Manual - 4Y series balances

View

Download
(6.52 MB)
Software Manual - Radwag-Mass -Node-RED

View

Download
(0.57 MB)
Start up Guide

View

Download
(3.51 MB)
Conformity Declarations
Conformity Declaration

View

Download
(0.04 MB)
Publications and Brochures
Principles of Metrology

View

Download
(0.10 MB)
Determination of Total And Respirable Air

View

Download
(0.21 MB)
Autotest

View

Download
(0.10 MB)
Guidelines for a weighing room for correct microbalance and mass comparator operation

View

Download
(0.82 MB)
Detection of vibrations at the electronic balances workstation

View

Download
(2.02 MB)
THBR System 2.0

View

Download
(5.17 MB)
4Y Series Balances

View

Download
(23.51 MB)
Micro Scale Measurement

View

Download
(2.74 MB)
Stainless Steel in RADWAG products. Standard and special applications

View

Download
(2.44 MB)
4Y Brand new series of laboratory balances

View

Download
(2.03 MB)
SQC in laboratory

View

Download
(2.31 MB)
Defined Weighing Profiles

View

Download
(1.36 MB)
Technical Documentation
Microbalances working conditions

View

Download
(2.25 MB)
Accessories
Workstation for Pipettes Calibration
Automatic Variable-Volume Pipettes
Antivibration Tables for Laboratory Balances
Professional weighing table
Audit Trail Reader
E2R System
Label Editor R02

Accessories

R-Pipettes

Accessories

R.Barcode

Accessories

R-LAB

Accessories

RAD-KEY

Accessories

RADWAG Connect

Accessories

RADWAG Development Studio
RADWAG Remote Desktop
LabVIEW Driver
Adapter for Pipette Calibration
Chamber for filter weighing
Receipt Printer
Label Printers
Antistatic ionizer
THBR 2.0 System - Ambient Conditions Monitoring
RS 232 cables (scale - EPSON printer)

Accessories

USB Hubs

Accessories

RS 232 – USB Converter
RS 232, RS 485 cables
Protective cover for balances
Barcode scanners
Anti-Draft Chamber for Microbalances
Displays
Power Adapters
Additional modules
21 CFR Part 11 Compliance Module3
Radwag Balances and Scales
Torunska 5
26-600 Radom
Poland
tel.: +48 48 386 60 00
e-mail: export@radwag.com
TIN: PL7960000327
Vimeo Radwag YouTube Radwag Facebook Radwag LinkedIn Radwag
© 2021 RADWAG Balances and Scales. All rights reserved.

Select language

×
Change language AlbanianAlbanian
Change language DanishDanish
Change language NederlandseNederlandse
Change language EstonianEstonian
Change language FinnishFinnish
Change language HungarianHungarian
Change language IcelandicIcelandic
Change language KazakhKazakh
Change language LatvianLatvian
Change language LithuanianLithuanian
Change language MacedonianMacedonian
Change language NorwegianNorwegian
Change language PortuguesePortuguese
Change language RomanianRomanian
Change language RussianRussian
Change language SlovakSlovak
Change language SlovenianSlovenian
Change language SwedishSwedish
Change language UkrainianUkrainian
Change language SerbianSerbian
Change language MontenegrinMontenegrin
Change language page on Deutsch Deutsch
Change language page on Español Español
Change language page on Français Français
Change language page on Italiano Italiano
Change language page on Polski Polski
Change language page on Türkiye Türkiye
Česky
Change website to USA USA
Change language page on 中文 中文
Subscribe
Facebook
Youtube
Vimeo
LinkedIn
Webinars
close